Data sheet BMI160 Small, low power inertial measurement unit Bosch Sensortec BMI160 - Data sheet Document revision 0.9 Document release date October 16th, 2018 Document number BST-BMI160-DS0001-08 Technical reference code(s) 0 273 141 187 Notes Data and descriptions in this document are subject to change without notice. Product photos and pictures are for illustration purposes only and may differ from the real product appearance. BMI160 Data sheet Page 2 BMI160 Small, low-power Inertial Measurement Unit The BMI160 is a highly integrated, low power inertial measurement unit (IMU) that provides precise acceleration and angular rate (gyroscopic) measurement. The BMI160 integrates: 16 bit digital, triaxial accelerometer 16 bit digital, triaxial gyroscope Key features High performance accelerometer and gyroscope (hardware synchronized) Very low power consumption: typ. 925 A (accelerometer and gyroscope in full operation) Android Lollipop compatible: significant motion and step detector / step counter (5 A each) Very small 2.5 x 3.0 mm2 footprint, height 0.83 mm Built-in power management unit (PMU) for advanced power management Power saving with fast start-up mode of gyroscope Wide power supply range: 1.71V ... 3.6V Allocatable FIFO buffer of 1024 bytes (capable of handling external sensor data) Hardware sensor time-stamps for accurate sensor data fusion Integrated interrupts for enhanced autonomous motion detection Flexible digital primary interface to connect to host over I2C or SPI Extended I2C mode with clock frequencies up to 1 MHz Additional secondary high speed interface for OIS application Capable of handling external sensor data (e.g. geomagnetic or barometric pressure sensors by Bosch Sensortec) Typical applications Augmented Reality Indoor navigation 3D scanning / indoor mapping Advanced gesture recognition Immersive gaming 9-axis motion detection Air mouse applications and pointers Pedometer / step counting Advanced system power management for mobile applications Optical image stabilization of camera modules Free-fall detection and warranty logging Target Devices Smart phones, tablet and transformer PCs Game controllers, remote controls and pointing devices Head tracking devices Wearable devices, e.g. smart watches or augmented reality glasses Sport and fitness devices Cameras, camera modules Toys, e.g. toy helicopters BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 3 General Description The BMI160 is an inertial measurement unit (IMU) consisting of a state-of-the-art 3-axis, low-g accelerometer and a low power 3-axis gyroscope. It has been designed for low power, high precision 6-axis and 9-axis applications in mobile phones, tablets, wearable devices, remote controls, game controllers, head-mounted devices and toys. The BMI160 is available in a compact 14-pin 2.5 x 3.0 x 0.83 mm3 LGA package. When accelerometer and gyroscope are in full operation mode, power consumption is typically 925 A, enabling always-on applications in battery driven devices. The BMI160 offers a wide VDD voltage range from 1.71V to 3.6V and a VDDIO range from 1.2V to 3.6V, allowing the BMI160 to be powered at 1.8V for both VDD and VDDIO. Due to its built-in hardware synchronization of the inertial sensor data and its ability to synchronize data of external devices such as geomagnetic sensors, BMI160 is ideally suited for augmented reality, gaming and navigation applications, which require highly accurate sensor data fusion. The BMI160 provides high precision sensor data together with the accurate timing of the corresponding data. The timestamps have a resolution of only 39 s. Further Bosch Sensortec sensors, e.g. geomagnetic (BMM150) can be connected as slave via a secondary I2C interface. In this configuration, the BMI160 controls the data acquisition of the external sensor and the synchronized data of all sensors is stored the register data and can be additionally stored in the built-in FIFO. The integrated 1024 byte FIFO buffer supports low power applications and prevents data loss in non-real-time systems. The intelligent FIFO architecture allows dynamic reallocation of FIFO space for accelerometer, gyroscope and external sensors, respectively. For typical 6-DoF applications, this is sufficient for approx. 0.75 s of data capture. In a typical 9-DoF application - including the geomagnetic sensor - this is sufficient for approx. 0.5 s. Like its predecessors, the BMI160 features an on-chip interrupt engine enabling low-power motion-based gesture recognition and context awareness. Examples of interrupts that can be issued in a power efficient manner are: any- or no-motion detection, tap or double tap sensing, orientation detection, free-fall or shock events. The BMI160 is Android 5.0 (Lollipop) compatible, and in the implementation of the Significant Motion and Step Detector interrupts, each consumes less than 30A. The smart built-in power management unit (PMU) can be configured, for example, to further lower the power consumption by automatically sending the gyroscope temporarily into fast start-up mode and waking it up again by internally using the any-motion interrupt of the accelerometer. By allowing longer sleep times of the host, the PMU contributes to significant further power saving on system level. Besides the flexible primary interface (I2C or SPI) that is used to connect to the host, BMI160 provides an additional secondary interface. This secondary interface can be used in SPI mode for OIS (optical image stabilization) applications in conjunction with camera modules, or in advanced gaming use cases. When connected to a geomagnetic sensor, BMI160 will trigger autonomous read-out of the sensor data from magnetometer without the need for intervention by the host processor. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 4 Index of Contents 1. SPECIFICATION ........................................................................................................................ 7 1.1 ELECTRICAL SPECIFICATION ................................................................................................ 7 1.2 ELECTRICAL AND PHYSICAL CHARACTERISTICS, MEASUREMENT PERFORMANCE ...................... 8 1.3 ABSOLUTE MAXIMUM RATINGS ........................................................................................... 11 2. FUNCTIONAL DESCRIPTION ................................................................................................. 12 2.1 BLOCK DIAGRAM ............................................................................................................... 12 2.2 POWER MODES ................................................................................................................. 13 2.2.1 SUSPEND MODE (ACCELEROMETER AND GYROSCOPE) ................................................................... 13 2.2.2 FAST START-UP MODE (GYROSCOPE ONLY ) ................................................................................... 14 2.2.3 TRANSITIONS BETWEEN POWER MODES ......................................................................................... 14 2.2.4 LOW POWER MODE (ACCELEROMETER ONLY) ................................................................................. 15 2.2.5 PMU (POWER MANAGEMENT UNIT) .............................................................................................. 16 2.3 SENSOR TIMING AND DATA SYNCHRONIZATION ................................................................... 18 2.3.1 SENSOR TIME .............................................................................................................................. 18 2.3.2 DATA SYNCHRONIZATION .............................................................................................................. 18 2.4 DATA PROCESSING ........................................................................................................... 19 2.4.1 DATA PROCESSING ACCELEROMETER ........................................................................................... 19 2.4.2 DATA PROCESSING GYROSCOPE .................................................................................................. 20 2.5 FIFO................................................................................................................................ 21 2.5.1 FIFO FRAMES ............................................................................................................................. 22 2.5.2 FIFO CONDITIONS AND DETAILS .................................................................................................... 26 2.6 INTERRUPT CONTROLLER .................................................................................................. 27 2.6.1 ANY-MOTION DETECTION (ACCEL) ................................................................................................. 27 2.6.2 SIGNIFICANT MOTION (ACCEL) ...................................................................................................... 28 2.6.3 STEP DETECTOR (ACCEL) ............................................................................................................ 30 2.6.4 TAP SENSING (ACCEL) ................................................................................................................. 30 2.6.5 ORIENTATION RECOGNITION (ACCEL) ............................................................................................ 31 2.6.6 FLAT DETECTION (ACCEL) ............................................................................................................ 37 2.6.7 LOW-G / FREE-FALL DETECTION (ACCEL)....................................................................................... 38 2.6.8 HIGH-G DETECTION (ACCEL) ......................................................................................................... 38 2.6.9 SLOW-MOTION ALERT / NO-MOTION INTERRUPT (ACCEL) .............................................................. 39 2.6.10 DATA READY DETECTION (ACCEL, GYRO AND EXTERNAL SENSORS) ............................................. 42 2.6.11 PMU TRIGGER (GYRO) .............................................................................................................. 42 2.6.12 FIFO INTERRUPTS (ACCEL, GYRO, AND EXTERNAL SENSORS) ...................................................... 42 2.7 STEP COUNTER ................................................................................................................ 43 2.8 DEVICE SELF TEST ............................................................................................................ 43 2.8.1 SELF-TEST ACCELEROMETER ........................................................................................................ 43 2.8.2 SELF-TEST GYROSCOPE ............................................................................................................... 44 2.9 OFFSET COMPENSATION ................................................................................................... 44 2.9.1 FAST OFFSET COMPENSATION....................................................................................................... 44 2.9.2 MANUAL OFFSET COMPENSATION .................................................................................................. 45 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 5 2.9.3 INLINE CALIBRATION ..................................................................................................................... 45 2.10 NON-VOLATILE MEMORY ................................................................................................. 45 2.11 REGISTER MAP ............................................................................................................... 47 2.11.1 REGISTER (0X00) CHIPID ......................................................................................................... 49 2.11.2 REGISTER (0X02) ERR_REG .................................................................................................... 49 2.11.3 REGISTER (0X03) PMU_STATUS ............................................................................................. 50 2.11.4 REGISTER (0X04-0X17) DATA ................................................................................................... 51 2.11.5 REGISTER (0X18-0X1A) SENSORTIME .................................................................................... 52 2.11.6 REGISTER (0X1B) STATUS ....................................................................................................... 53 2.11.7 REGISTER (0X1C-0X1F) INT_STATUS ..................................................................................... 53 2.11.8 REGISTER (0X20-0X21) TEMPERATURE ................................................................................. 55 2.11.9 REGISTER (0X22-0X23) FIFO_LENGTH ................................................................................... 56 2.11.10 REGISTER (0X24) FIFO_DATA ................................................................................................ 57 2.11.11 REGISTER (0X40) ACC_CONF ................................................................................................ 57 2.11.12 REGISTER (0X41) ACC_RANGE ............................................................................................. 58 2.11.13 REGISTER (0X42) GYR_CONF................................................................................................ 59 2.11.14 REGISTER (0X43) GYR_RANGE ............................................................................................. 60 2.11.15 REGISTER (0X44) MAG_CONF ............................................................................................... 60 2.11.16 REGISTER (0X45) FIFO_DOWNS ........................................................................................... 61 2.11.17 REGISTER (0X46-0X47) FIFO_CONFIG .................................................................................. 62 2.11.18 REGISTER (0X4B-0X4F) MAG_IF ............................................................................................ 63 2.11.19 REGISTER (0X50-0X52) INT_EN.............................................................................................. 63 2.11.20 REGISTER (0X53) INT_OUT_CTRL ......................................................................................... 65 2.11.21 REGISTER (0X54) INT_LATCH ................................................................................................ 65 2.11.22 REGISTER (0X55-0X57) INT_MAP ........................................................................................... 66 2.11.23 REGISTER (0X58-0X59) INT_DATA ......................................................................................... 68 2.11.24 REGISTER (0X5A-0X5E) INT_LOWHIGH ................................................................................ 69 2.11.25 REGISTER (0X5F-0X62) INT_MOTION .................................................................................... 71 2.11.26 REGISTER (0X63-0X64) INT_TAP............................................................................................ 73 2.11.27 REGISTER (0X65-0X66) INT_ORIENT ..................................................................................... 74 2.11.28 REGISTER (0X67-0X68) INT_FLAT .......................................................................................... 75 2.11.29 REGISTER (0X69) FOC_CONF ................................................................................................ 76 2.11.30 REGISTER (0X6A) CONF ......................................................................................................... 77 2.11.31 REGISTER (0X6B) IF_CONF .................................................................................................... 77 2.11.32 REGISTER (0X6C) PMU_TRIGGER ........................................................................................ 78 2.11.33 REGISTER (0X6D) SELF_TEST ............................................................................................... 79 2.11.34 REGISTER (0X70) NV_CONF .................................................................................................. 80 2.11.35 REGISTER (0X71-0X77) OFFSET ............................................................................................ 80 2.11.36 REGISTER (0X78-0X79) STEP_CNT........................................................................................ 81 2.11.37 REGISTER (0X7A-0X7B) STEP_CONF .................................................................................... 82 2.11.38 REGISTER (0X7E) CMD ........................................................................................................... 83 3. DIGITAL INTERFACES ............................................................................................................ 86 3.1 INTERFACES ..................................................................................................................... 86 3.2 PRIMARY INTERFACE ......................................................................................................... 86 3.2.1 PRIMARY INTERFACE I2C/SPI PROTOCOL SELECTION ................................................................... 87 3.2.2 PRIMARY SPI INTERFACE ............................................................................................................. 88 3.2.3 PRIMARY I2C INTERFACE ............................................................................................................. 91 3.2.4 SPI AND IC ACCESS RESTRICTIONS ............................................................................................ 95 3.3 SECONDARY INTERFACE.................................................................................................... 96 3.3.1 MAGNETOMETER CONNECTED TO SECONDARY INTERFACE ............................................................. 96 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 6 3.3.2 CAMERA MODULE CONNECTED TO SECONDARY INTERFACE FOR OIS............................................... 98 4. PIN-OUT AND CONNECTION DIAGRAMS ............................................................................ 99 4.1 PIN-OUT ........................................................................................................................... 99 4.2 CONNECTION DIAGRAMS TO USE PRIMARY INTERFACE ONLY .............................................. 100 4.2.1 I2C AS PRIMARY INTERFACE ........................................................................................................ 100 4.2.2 SPI 3-WIRE AS PRIMARY INTERFACE............................................................................................ 100 4.2.3 SPI 4-WIRE AS PRIMARY INTERFACE............................................................................................ 101 4.3 CONNECTION DIAGRAMS TO USE ADDITIONAL SECONDARY INTERFACE ................................ 101 4.3.1 PRIMARY SPI 4-WIRE AND SECONDARY MAGNETOMETER INTERFACE (I2C) .................................... 101 4.3.2 PRIMARY SPI 3-WIRE AND SECONDARY MAGNETOMETER INTERFACE (I2C) .................................... 102 4.3.3 PRIMARY I2C AND SECONDARY MAGNETOMETER INTERFACE (I2C) ................................................ 102 4.3.4 PRIMARY I2C AND SECONDARY 4-WIRE SPI AS OIS INTERFACE .................................................... 103 4.3.5 PRIMARY I2C AND SECONDARY 3-WIRE SPI AS OIS INTERFACE .................................................... 103 5. PACKAGE .............................................................................................................................. 104 5.1 OUTLINE DIMENSIONS ..................................................................................................... 104 5.2 SENSING AXES ORIENTATION ........................................................................................... 105 5.3 LANDING PATTERN RECOMMENDATION ............................................................................. 106 5.4 MARKING........................................................................................................................ 107 5.4.1 MASS PRODUCTION MARKING...................................................................................................... 107 5.4.2 ENGINEERING SAMPLES .............................................................................................................. 107 5.5 SOLDERING GUIDELINES .................................................................................................. 108 5.6 HANDLING INSTRUCTIONS ................................................................................................ 109 5.7 TAPE AND REEL SPECIFICATION ....................................................................................... 109 5.7.1 ORIENTATION WITHIN THE REEL................................................................................................... 110 5.8 ENVIRONMENTAL SAFETY ................................................................................................ 110 5.8.1 HALOGEN CONTENT ................................................................................................................... 110 5.8.2 MULTIPLE SOURCING .................................................................................................................. 110 6. LEGAL DISCLAIMER............................................................................................................. 111 6.1 ENGINEERING SAMPLES .................................................................................................. 111 6.2 PRODUCT USE ................................................................................................................ 111 6.3 APPLICATION EXAMPLES AND HINTS ................................................................................. 111 7. DOCUMENT HISTORY AND MODIFICATIONS ................................................................... 112 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 7 1. Specification If not stated otherwise, the given values are over lifetime and full performance temperature and voltage ranges, minimum/maximum values are 3. The specifications are split into accelerometer and gyroscope sections of the BMI160. 1.1 Electrical specification VDD and VDDIO can be ramped in arbitrary order without causing the device to consume significant currents. The values of the voltage at VDD and the VDDIO pins can be chosen arbitrarily within their respective limits. The device only operates within specifications if the both voltages at VDD and VDDIO pins are within the specified range. The voltage levels at the digital input pins must not fall below GNDIO-0.3V or go above VDDIO+0.3V to prevent excessive current flowing into the respective input pin. BMI160 contains a brownout detector, which ensures integrity of data in the non-volatile memory under all operating conditions. Table 1: Electrical parameter specification Parameter Supply Voltage Internal Domains Supply Voltage I/O Domain Voltage Input Low Level Voltage Input High Level Max Unit 1.71 3.0 3.6 V VDDIO 1.2 2.4 3.6 V 0.3VDDIO - VIL,a SPI VIH,a SPI VOL,a Voltage Output High Level VOH,a Current consumption Typ VDD Voltage Output Low Level Operating Temperature NVM write-cycles OPERATING CONDITIONS BMI160 Condition Min Symbol IDD - VDDIO=1.62V, IOL=3mA, SPI 0.2VDDIO - VDDIO=1.2V, IOL=3mA, SPI 0.23VDDIO - VDDIO=1.62V, IOH=3mA, SPI 0.8VDDIO - VDDIO=1.2V, IOH=3mA, SPI 0.62VDDIO - TA nNVM 0.7VDDIO -40 Non-volatile memory Gyro in fast start-up, accel in suspend mode, TA=25C Gyro and accel full operation mode, TA=25C Gyro full operation mode, accel in suspend, TA=25C Accel full operation mode, gyro in suspend, TA=25C Gyro and accel in suspend mode, TA=25C Significant motion detector, gyro in suspend, accel in low power mode @50Hz, TA=25C Step detector, gyro in suspend, accel in low BST-BMI160-DS000-08 | Revision 0.9 | October 2018 +85 14 C Cycles 500 600 925 990 850 900 180 300 3 10 A 20 20 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 8 power mode @50Hz, TA=25C 1.2 Electrical and physical characteristics, measurement performance Table 2: Electrical characteristics accelerometer OPERATING CONDITIONS ACCELEROMETER Parameter Symbol Condition Min Typ gFS2g Acceleration Range gFS4g gFS8g Selectable via serial digital interface gFS16g Start-up time tA,su Suspend/low power mode to normal mode, ODR=1.6kHz Max Units 2 g 4 g 8 g 16 g 3.2 3.8 ms Typ Max Units OUTPUT SIGNAL ACCELEROMETER Parameter Symbol Condition Min Resolution Sensitivity 16 S2g gFS2g, TA=25C 15729 16384 17039 LSB/g S4g gFS4g, TA=25C 7864 8192 8520 LSB/g S8g gFS8g, TA=25C 3932 4096 4260 LSB/g S16g gFS16g, TA=25C 1966 2048 2130 LSB/g Sensitivity Temperature Drift TCSA Sensitivity change over supply voltage SA,VDD OffA, init OffA,board Zero-g Offset OffA,MSL OffA,life 1 2 bit Zero-g Offset Temperature Drift TCOA Nonlinearity NLA gFS8g, Nominal VDD supplies best fit straight line T =25C, A VDD,min VDD VDD,max best fit straight line gFS8g, TA=25C, nominal VDD supplies, component level gFS8g, TA=25C, nominal VDD supplies, soldered, board level gFS8g, TA=25C, nominal VDD supplies, after MSL1prec. 1 / soldered gFS8g, TA=25C, nominal VDD supplies, soldered, over life time2 gFS8g, Nominal VDD supplies best fit straight line Best fit straight line, gFS8g 0.03 %/K 0.01 %/V 25 mg 40 mg 70 mg 150 mg 1.0 mg/K 0.5 %FS Values taken from qualification, according to JEDEC J-STD-020D.1 Values taken from qualification, according to JEDEC J-STD-020D.1 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet nA,nd Output Noise nA,rms Page 9 gFS8g, TA=25C, nominal VDD, Normal mode Filter setting 80 Hz, ODR 200 Hz 180 300 g/Hz 1.8 mg-rms Cross Axis Sensitivity SA Relative contribution between any two of the three axes 1 % Alignment Error EA Relative to package outline 0.5 Output Data rate (set of x,y,z rate) Output Data rate accuracy (set of x,y,z rate) ODRA AODRA 12.5 Normal mode, over whole operating temperature range 1600 1 Hz % Table 3: Electrical characteristics gyroscope OPERATING CONDITIONS GYROSCOPE Parameter Symbol Condition Min RFS125 Max Unit 125 /s 250 /s 500 /s RFS1000 1,000 /s RFS2000 2,000 /s RFS250 Range Typ RFS500 Selectable via serial digital interface tG,su Suspend to normal mode ODRG=1600Hz 55 ms tG,FS Fast start-up to normal mode 10 ms Start-up time OUTPUT SIGNAL GYROSCOPE Sensitivity RFS2000 Ta=25C 15.9 16.4 16.9 LSB//s RFS1000 Ta=25C 31.8 32.8 33.8 LSB//s RFS500 Ta=25C 63.6 65.6 67.6 LSB//s RFS250 Ta=25C 127.2 131.2 135.2 LSB//s RFS125 Ta=25C 254.5 262.4 270.3 LSB//s Sensitivity change over temperature TCSG Sensitivity change over supply voltage SG,VDD Nonlinearity NLG g- Sensitivity BST-BMI160-DS000-08 | Revision 0.9 | October 2018 RFS2000, Nominal VDD supplies best fit straight line T =25C, A VDD,min VDD VDD,max best fit straight line Best fit straight line RFS1000, RFS2000 Sensitivity to acceleration stimuli in all three axis (frequency <20kHz) 0.02 %/K 0.01 %/V 0.1 %FS 0.1 /s/g Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Zero-rate offset Off x y and z Zero-Rate offset Over temperature Off x, oT y, oT and z,oT Zero-rate offset change over temperature TCOG Output Noise Output Data Rate (set of x,y,z rate) Output Data rate accuracy (set of x,y,z rate) Cross Axis Sensitivity Page 10 T =25C, A fast offset compensation off 3 /s -40C T +85C 3 /s 0.05 /s/K A -40C T +85C, A best fit straight line nG,nD @10 Hz 0.007 /s/Hz nG,rms Filter setting 74.6Hz, ODR 200 Hz 0.07 /s rms ODRG 25 AODRG Over whole operating temperature range XG,S Sensitivity to stimuli in non-sense-direction 3200 1 Hz % 2 % Table 4: Electrical characteristics temperature sensor OPERATING CONDITIONS AND OUTPUT SIGNAL OF TEMPERATURE SENSOR Parameter Symbol Temperature Sensor Measurement Range TS Condition Min Typ -40 Max Unit 85 C Temperature Sensor Slope dTS 0.002 K/LSB Temperature Sensor Offset OTS 2 K Output Data Rate ODRT Accelerometer on or gyro in fast start-up 0.8 Hz Gyro active 100 Hz Accelerometer on or gyro in fast start-up 8 bit Gyro active 16 bit Resolution nT BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 11 1.3 Absolute maximum ratings Table 5: Absolute maximum ratings Parameter Condition Min Max Units VDD Pin -0.3 4.25 V VDDIO Pin -0.3 4.25 V Voltage at any Logic Pin Non-Supply Pin -0.3 VDDIO+0.3 V Passive Storage Temp. Range 65% rel. H. -50 +150 C None-volatile memory (NVM) Data Retention T = 85C, after 15 cycles 10 Voltage at Supply Pin Mechanical Shock ESD y Duration 200 s, half sine 10,000 g Duration 1.0 ms, half sine 2,000 g Free fall onto hard surfaces 1.8 m HBM, at any Pin 2 kV CDM 500 V MM 200 V Note: Stresses above these listed maximum ratings may cause permanent damage to the device. Exposure beyond specified electrical characteristics as specified in Table 1 may affect device reliability or cause malfunction. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 12 2. Functional Description 2.1 Block diagram The figure below depicts the dataflow in BMI160 and the configuration parameters for data rates: SENSORTIME Accel ADC select Gyro SENSOR DATA AND SENSORTIME REGISTER SPI / I2C DIGITAL SIGNAL CONDITIONING ADC FIFO ENGINE EXTERNAL MAGNET DATA GYRO PREFILTERED DATA INTERRUPT ENGINE INT1, INT2 PRIMARY DIGITAL INTERFACE LEGACY INTERRUPTS RAW DATA STEP DETECTOR SIGNIFICANT MOTION INTERRUPTS SECONDARY DIGITAL INTERFACE CONFIGURABLE AS: GYRO OIS (SPI SLAVE) OR MAGNET (I2C MASTER) Step Counter OIS Controller (SPI) MAGNET (I2C) Magnet Figure 1: Block diagram of data flow The pre-filtered input data may be already temperature compensated or other low level correction operations may be applied to them. The data from the sensor are always sampled with a data rate of 6400 Hz for the gyroscope and 1600 Hz for the accelerometer. The data are filtered to an output data rate configured in the Register (0x40) ACC_CONF and Register (0x42) GYR_CONF for accelerometer and gyroscope, respectively. The data processing implements a low pass filter configured in the Register (0x40) ACC_CONF and Register (0x42) GYR_CONF for accelerometer and gyroscope, respectively. In addition further down sampling for the interrupt engines and the FIFO is possible and configured in the Register (0x45) FIFO_DOWNS. This down sampling discards data frames. The sensor time is synchronized with the update of the data register. Synchronization is a purely digital statement. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 13 2.2 Power modes By default BMI160 accel and gyro are in suspend mode after powering up the device. The device is powering up in less than 10ms. Three power modes are supported for accelerometer and gyroscope: Accelerometer Normal mode: full chip operation Low power mode: duty-cycling between suspend and normal mode. FIFO data readout are supported in lower power mode to a limited extent, see Register PMU_STATUS. Suspend mode: No sampling takes place, all data is retained, and delays between subsequent I2C operations are allowed. FIFO data readout is not supported in suspend mode. Gyroscope Normal mode: same as accelerometer Suspend mode: same as accelerometer Fast start-up mode: start-up delay time to normal mode 10 ms Table 6: Power modes of accelerometer and gyro in BMI160 Accelerometer Gyroscope external Magnetometer BMM150 full operation mode Normal mode Sleep modes Fast Start-up mode Suspend mode Low power mode Low power modes Suspend and fast start-up modes are sleep modes. Switching between normal and low power mode will not impact the output data from the sensor. This allows the system to switch from low power mode to normal mode to read out the sensor data in the FIFO with a data rate limited by the serial interface. 2.2.1 Suspend mode (accelerometer and gyroscope) In suspend mode, the MEMS sensors are powered off but the digital circuitry is still active. Note: When all sensors are in suspend or low power mode, burst writes are not supported, normal writes need wait times after the write command is issued (~400 s), and burst reads are not supported on Register (0x24) FIFO_DATA. If all sensors (accelerometer, gyroscope or magnetometer) are in either suspend or low power mode, the FIFO must not be read. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 14 2.2.2 Fast start-up mode (gyroscope only ) In fast start-up mode the sensing analog part is powered down, while the drive and the digital part remains largely operational. No data acquisition is performed. The latest rate data and the content of all configuration registers are kept. The fast start-up mode allows a fast transition (10 ms) into normal mode while keeping power consumption significantly lower than in normal mode. 2.2.3 Transitions between power modes The table below for the power modes of gyroscope and accelerometer shows which power mode combinations are supported by BMI160. With regard to the below diagram, transitions between power modes are only allowed in horizontal or vertical direction. Transitions in diagonal direction are not supported. Table 7: Typical total current consumption in A according to accel/gyro modes Current consumption in A Gyroscope Mode Accelerometer Mode Suspend Normal Low Power Suspend 3 180 See Table 8 Fast Start-up 500 580 n.a. Normal 850 925 n.a. The power mode setting can be configures independently from the output data rate set. The main difference between normal and low power mode is the power consumption as shown in the figure below. If the sleep time between two configured sampling intervals becomes too short to duty cycle between suspend and normal mode, the accelerometer stays automatically in normal mode. In order to make the transition between low power and normal mode as transparent as possible, an undersampling mode is defined in such a way that it mimics the behavior of the lower data rate in low power mode in normal mode. The low power mode then only switches clock sources. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 15 Figure 2: low power and normal mode operation 2.2.4 Low power mode (accelerometer only) In low power modes the accelerometer toggles between normal mode and suspend mode. The power consumption is given by the power consumption in normal mode times the fraction of time the sensor is in normal mode. The time in normal mode is defined by the startup time of the MEMS element, plus the analogue settling time. This results in a minimum time in normal mode of the settling time plus (averaged samples)/1600 Hz. Regarding register read and write operations, the note in chapter 2.2.1 applies. 2.2.4.1 Power Consumption in accelerometer low power mode When accelerometer and gyroscope are operated in normal mode, there is no significant dependence on the specific settings like ODR, undersampling and bandwidth. The same applies to the fast power up mode of the gyroscope. If the accelerometer, however, is operated in low power mode and undersampling is enabled, the power consumption of the accel depends on the two parameters ODR and number of averaging cycles. In low power mode (gyroscope in suspend), the actual power consumption depends on the selected setting in Register (0x40) ACC_CONF. Table 8: Typical total current consumption in A according to number of averaging cycles and accelerometer ODR settings (gyroscope in suspend mode and accelerometer in low power mode and undersampling) AVG - number of averaging cycles Typical current consumption in A 1 2 4 8 16 32 64 128 0.78125 3 3 4 4 5 6 9 14 1.5625 4 4 4 5 6 9 14 25 ODR of accelerometer BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 16 in low power mode [Hz] 3.125 4 5 5 7 9 15 25 46 6.25 6 6 8 10 16 26 47 90 (gyroscope in suspend mode) 12.5 8 10 12 18 28 49 92 25 14 17 22 32 54 50 25 30 41 62 104 100 46 57 78 121 200 90 111 154 400 172 172 n. m.* normal 96 mode* normal mode* normal mode* normal mode* normal mode* 800 normal mode* 1600 normal mode* * Note: Those combinations are not available in low-power mode. Cycling in suspend is not possible. Pls. switch to normal power mode for these combinations. 2.2.4.2 Noise of accelerometer in low power mode When acc_us=1, accelerometer is in undersampling mode. The noise is only depending on the number of averaging cycles Table 9: Accel noise in mg according to averaging with undersampling (range +/- 8g) AVG - number of averaging cycles 1 2 4 8 16 32 64 128 RMS-noise (typ.) [mg] 4.3 3.5 3.0 2.0 1.5 1.1 0.7 0.5 2.2.5 PMU (Power Management Unit) The integrated PMU (Power Management Unit) allows advanced power management features by combining power management features of all built-in sensors and externally available wake-up devices. See chapter 2.6.11, PMU Trigger (Gyro). 2.2.5.1 Automatic gyroscope power mode changes To further lower the power consumption, the gyroscope may be configured to be temporarily put into sleep mode, which is in BMI160 configurable as suspend or fast-start-up mode, when no motion is detected by the accelerometer. This mode benefits from the accelerometer any-motion and nomotion interrupt that is used to control the power state of the gyroscope. To configure this feature Register (0x6C) PMU_TRIGGER is used. 2.2.5.2 Power management with external geomagnetic sensor An external magnetometer can be connected via the secondary interface. The drivers support Bosch Sensortec devices. The PMU allows advanced power management with the external magnetometer. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 17 Table 10: Supported magnetometer and accelerometer power modes (only horizontal and vertical transitions are allowed) Accel Suspend Normal Low power Suspend Supported Supported Supported Normal Supported Supported Supported Magnetometer Note, for setting the magnetometer to suspend mode it is required to put the magnetometer itself into suspend mode through the magnetometer interface manual mode mag_man_en in Register (0x4B-0x4F) MAG_IF and to set the magnetometer interface after that to suspend using a mag_set_pmu_mode command in the Register (0x7E) CMD. Changing the magnetometer interface power mode to suspend does not imply any mode change in the magnetometer. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 18 2.3 Sensor Timing and Data synchronization 2.3.1 Sensor Time The Register (0x18-0x1A) SENSORTIME is a free running counter, which increments with a resolution of 39 s. All sensor events e.g. updates of data registers are synchronous to this register as defined in the table below. With every update of the data register or the FIFO, a bit m in the Register (0x18-0x1A) SENSORTIME toggles where m depends on the output data rate for the data register and the output data rate and the FIFO down sampling rate for the FIFO. The table below shows which bit toggles for which update rate of data register and FIFO. The time stamps in Register (0x18-0x1A) SENSORTIME are available independent of the power mode the device is in. Table 11: Sensor time Bit m in sensor_time 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Resolution [ms] 0.039 0.078 0.156 0.3125 0.625 1.25 2.5 5 10 20 40 80 160 320 640 1280 2560 5120 10240 20480 40960 81920 163840 327680 Update rate [Hz] 25641 12820 6400 3200 1600 800 400 200 100 50 25 12.5 6.25 3.125 1.56 0.78 0.39 0.20 0.10 0.049 0.024 0.012 0.0061 0.0031 2.3.2 Data synchronization The sensor data from accelerometer and gyroscope are strictly synchronized on hardware level, i.e. they run on exactly the same sampling rate. BMI160 supports various level of data synchronization: Internal hardware synchronization of accelerometer, gyroscope and external sensor data. High precision synchronization of external data with sensor data through hardware timestamps. The hardware timestamp resolution is 39 s. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 19 Hardware synchronization of the data of accelerometer, gyro and external sensor through a unique DRDY interrupt signal. FIFO entries of the accelerometer, gyro and external sensor are already synchronized by hardware. The according time stamp can be provided with each full FIFO read. Synchronization of external data (e.g. magnetometer data) with FIFO data at data sampling granularity through hardware signaling 2.4 Data Processing The accelerometer digital filter can be configured through the parameters: acc_bwp, acc_odr and acc_us. The gyroscope digital filter can be configured through the parameters: gyr_bwp and gyr_odr. There is no undersampling parameter for the gyroscope. Note: Illegal settings in configuration registers will result in an error code in the Register (0x02) ERR_REG. The content of the data register is undefined, and if the FIFO is used, it may contain no value. 2.4.1 Data Processing Accelerometer The accelerometer digital filter can be configured through the parameters: acc_bwp, acc_odr and acc_us in Register (0x40) ACC_CONF for the accelerometer. The accelerometer data can only be processed in normal power mode or in low power mode. 2.4.1.1 Accelerometer data processing for normal power mode When normal power mode is used, the undersampling mode should be disabled (acc_us=0b0). In this configuration mode, the accelerometer data is sampled at equidistant points in the time, defined by the accelerometer output data rate parameter (acc_odr). The output data rate can be configured in one of eight different valid ODR configurations going from 12.5Hz up to 1600Hz. Note: Lower ODR values than 12.5Hz are not allowed when undersampling mode is not enabled. If they are used they result in an error code in Register (0x02) ERR_REG. When acc_us=0b0, the acc_bwp parameter needs to be set to 0b010 (normal mode). The filter bandwidth shows a 3db cutoff frequency shown in the following table: Table 12: 3dB cutoff frequency of the accelerometer according to ODR with normal filter mode Accelerometer ODR [Hz] 3dB Cutoff frequency [Hz] 12,5 25 50 100 200 5.06 10.12 20.25 40.5 80 400 162 800 324 1600 684 (155 for Z axis) (262 for Z axis) (353 for Z axis) The noise is also depending on the filter settings and ODR, see table below. Table 13: Accelerometer noise in mg according to ODR with normal filter mode (range +/- 8g) ODR in Hz 25 50 100 200 400 800 1600 RMS-Noise (typ.) [mg] 0.6 0.9 1.3 1.8 2.4 3.3 4.9 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 20 When the filter mode is set to OSR2 (acc_bwp=0b001 and acc_us=0b0), both stages of the digital filter are used and the data is oversampled with an oversampling rate of 2. That means that for a certain filter configuration, the ODR has to be 2 times higher than in the normal filter mode. Conversely, for a certain filter configuration, the filter bandwidth will be the half of the bandwidth achieved for the same ODR in the normal filter mode. For example, for ODR=50Hz we will have a 3dB cutoff frequency of 10.12Hz. When the filter mode is set to OSR4 (acc_bwp=0b000 and acc_us=0b0), both stages of the digital filter are used and the data is oversampled with an oversampling rate of 4. That means that for a certain filter configuration, the ODR has to be 4 times higher than in the normal filter mode. Conversely, for a certain filter configuration, the filter bandwidth will be 4 times smaller than the bandwidth achieved for the same ODR in the normal filter mode. For example, for ODR=50Hz we will have a 3dB cutoff frequency of 5.06Hz. 2.4.1.2 Accelerometer data processing for low power mode When low power mode is used, the undersampling mode must be enabled (acc_us=0b1). In this configuration mode, the accelerometer regularly changes between a suspend power mode phase where no measurement is performed and a normal power mode phase, where data is acquired. The period of the duty cycle for changing between suspend and normal mode will be determined by the output data rate (acc_odr). The output data rate can be configured in one of 12 different valid ODR configurations going from 0.78Hz up to 1600Hz. The samples acquired during the normal mode phase will be averaged and the result will be the output data. The number of averaged samples can be determined by the parameter acc_bwp through the following formula: averaged samples = 2(Val(acc_bwp)) skipped samples = (1600/ODR)-averaged samples A higher number of averaged samples will result in a lower noise level of the signal, but since the normal power mode phase is increased, the power consumption will also rise. This relationship can be observed in chapter Power Consumption. Note: When undersampling (acc_us=0b1 in Register (0x40) ACC_CONF) and the use of prefiltered data for interrupts or FIFO is configured an error code is flagged in Register (0x02) ERR_REG. Pre-filtered data for interrupts are configured through int_motion_src=0b1 or int_tap_src=0b1 in Register (0x58-0x59) INT_DATA. Pre-filtered data for the FIFO are configured through acc_fifo_filt_data=0b0 in Register (0x45) FIFO_DOWNS. 2.4.2 Data Processing Gyroscope The gyroscope digital filter can be configured through the parameters: gyr_bwp and gyr_odr in GYR_CONF for the gyroscope. There is no undersampling option for the gyroscope data processing. The gyroscope data can only be processed in normal power mode. There are three data processing modes defined by gyr_bwp. Normal mode, OSR2, OSR4. For details see chapter 2.11.13. 2.4.2.1 Gyroscope data processing for normal power mode When the filter mode is set to normal (gyr_bwp=0b010), the gyroscope data is sampled at equidistant points in the time, defined by the gyroscope output data rate parameter (gyr_odr). The output data rate can be configured in one of eight different valid ODR configurations going from 25Hz up to 3200Hz. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 21 Note: Lower ODR values than 25Hz are not allowed. If they are used they result in an error code in Register (0x02) ERR_REG. The filter bandwidth as configured by gyr-odr shows a 3db cutoff frequency shown in the following table: Gyroscope ODR [Hz] 25 3dB Cutoff frequency [Hz] 10.7 50 20.8 100 39.9 200 74.6 400 136.6 800 254.6 1600 523.9 3200 890 When the filter mode is set to OSR2 (gyr_bwp=0b001), both stages of the digital filter are used and the data is oversampled with an oversampling rate of 2. That means that for a certain filter configuration, the ODR has to be 2 times higher than in the normal filter mode. Conversely, for a certain filter configuration, the filter bandwidth will be the approximately half of the bandwidth achieved for the same ODR in the normal filter mode. For example, for ODR=50Hz we will have a 3dB cutoff frequency of 10.12Hz. When the filter mode is set to OSR4 (gyr_bwp=0b000), both stages of the digital filter are used and the data is oversampled with an oversampling rate of 4. That means that for a certain filter configuration, the ODR has to be 4 times higher than in the normal filter mode. Conversely, for a certain filter configuration, the filter bandwidth will be approximately 4 times smaller than the bandwidth achieved for the same ODR in the normal filter mode. For example, for ODR=50Hz we will have a 3dB cutoff frequency of 5.06Hz. Note: the gyroscope doesn't feature a low power mode. Therefore, there is also no undersampling mode for the gyroscope data processing. 2.5 FIFO A FIFO is integrated in BMI160 to support low power applications and prevent data loss in nonreal-time systems. The FIFO has a size of 1024 bytes. The FIFO architecture supports to dynamically allocate FIFO space for accelerometer and gyroscope. For typical 6 DoF applications, this is sufficient for approx. 0.75 s of data capture. In typical 9DoF applications - including the magnetometer - this is sufficient for approx. 0.5 s. If not all sensors are enabled or lower ODR is used on one or more sensors, FIFO size will be sufficient for capturing data longer, increasing ODR of one or more sensors will reduce available capturing time. The FIFO features a FIFO full and watermark interrupt. Details can be found in chapter 2.6.12. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 22 A schematic of the data path when the FIFO is used is shown in the figure below. SENSORTIME Accel ADC Gyro ADC FIFO configuration select DIGITAL SIGNAL CONDITIONING FIFO frames (regular & control) from FIFO ENGINE FIFO_DATA register EXTERNAL MAGNET DATA GYRO PREFILTERED DATA PRIMARY DIGITAL INTERFACE ... RAW DATA SECONDARY DIGITAL INTERFACE CONFIGURABLE AS: GYRO OIS (SPI SLAVE) OR MAGNET (I2C MASTER) FIFO full INT watermark INT External INT signals MAGNET (I2C) Magnet Figure 3: Block diagram of FIFO data path 2.5.1 FIFO Frames When using the FIFO, the stored data can be read out by performing a burst read on the register (0x24) FIFO_DATA. The data is stored in units called frames. 2.5.1.1 Frame rates The frame rate for the FIFO is defined by the maximum output data rate of the sensors enabled for the FIFO via the Register (0x46-0x47) FIFO_CONFIG. If pre-filtered data are selected in Register (0x45) FIFO_DOWNS, a data rate of 6400 Hz for the gyroscope and 1600 Hz for the accelerometer is used. The frame rate can be reduced further via downsampling (Register (0x45) FIFO_DOWNS). This can be done independently for each sensor. Downsampling just drops sensor data; no data processing or filtering is performed. 2.5.1.2 Frame format When using the FIFO, the stored data can be read out by performing a burst read on the register (0x24) FIFO_DATA. The data will be stored in frames. The frame format is important for the software to appropriately interpret the information read out from the FIFO. The FIFO can be configured to store data in either header mode or in headerless mode (see figure below). The headerless mode is usually used when neither the structure of data nor the number of sensors change during data acquisition. In this case, the number of storable frames can be maximized. In contrast, the header mode is intended for situations where flexibility in the data structure is required, e.g. when sensors runs at different ODRs or when switching sensors on or off on the fly during operation. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Headerless mode (only data) Page 23 Regular frames (same ODR for different sensor ) FIFO Frame Format Configuration Regular frames (different ODR for different sensor) Header mode (header+data) Skip frame Control frames Sensortime frame FIFO Input Config frame Figure 4: FIFO frame configurations In headerless mode no header byte is used and the frames consist only of data bytes. The data bytes will always be sensor data. Only regular frames with the same ODR for all sensors are supported and no external interrupt flags are possible. This mode has the advantage of an easy frame format and an optimized usage of the 1024 bytes of FIFO storage. It can be selected by disabling fifo_header in Register (0x46-0x47) FIFO_CONFIG. In case of overreading the FIFO, non-valid frames always contain the fixed expression (magic number) 0x80 in the data frame. In header mode every frame consists of a header byte followed by one or more data bytes. The header defines the frame type and contains parameters for the frame. The data bytes may be sensor data or control data. Header mode supports different ODRs for the different sensor data and external interrupt flags. This mode therefore has the advantage of allowing maximum flexibility of the FIFO engine. It is activated by enabling fifo_header in Register (0x46-0x47) FIFO_CONFIG. 2.5.1.3 Header byte format The header format is shown below: Bit Content 7 fh_mode<1:0> 6 5 fh_parm<3:2> 4 Bit Read/Write 3 fh_parm<1:0> 2 1 fh_ext<1:0> 0 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 24 The fh_mode, fh_opt and fh_ext fields are defined as fh_mode<1:0> 0b10 Definition Regular fh_parm <3:0> Frame content 0b01 0b00 0b11 Control Reserved Reserved Control Opcode Na Na fh_ext<1:0> Tag of INT2 and INT1 f_parm=0b0000 is invalid for regular mode, a header of 0x80 indicates an uninitialized frame. 2.5.1.4 Data bytes Format When the FIFO is set to "headerless mode", only sensor data will be saved into the FIFO (in the same order as in the data register). Any combination of accelerometer, gyroscope and external sensor data can be stored. External interrupt tags are not supported in headerless mode. When the FIFO is set to "header mode", the data byte format is different depending on the type of frame. There are two basic frame types, control frames and regular data frames. Each different type of control frame has its own data byte format. It can contain skipped frames, sensortime data or FIFO configuration information as explained in the following chapters. If the frame type is a regular frame (sensor data), the data byte section of the frame depend on how the data is being transmitted in this frame (as specified in the header byte section). It can include data from only one sensor or any combination of accelerometer, gyroscope and external sensor data. 2.5.1.5 Frame types Regular frame (fh_mode=0b10) Regular frames are the standard FIFO frames and contain sensor data. Regular frames can be identified by fh_mode set to 0b10 in the header byte section. The fh_parm frame defines which sensors are included in the data byte of the frame. The format of the fh_param is defined in the following table: Name Bit Content 3 reserved fh_parm<2:0> 2 fifo_mag_data 1 fifo_gyr_data 0 fifo_acc_data When fifo__data is set to `1'(`0'), data for sensor x is included (not included) in the data part of the frame. The fh_ext<1:0> field is set when an external interrupt is triggered. External interrupt tags are configured using int_output_en in Register (0x53) INT_OUT_CTRL, int_input_en in Register (0x54) INT_LATCH and fifo_tag_int_en in Register (0x46-0x47) FIFO_CONFIG. For details, please refer to chapter 2.5.2.4. The data byte part for regular data frames is identical to the format defined for the Register (0x040x17) DATA. If a header indicates that not all sensors are included in the frame, these data are skipped and do not consume space in the FIFO. Control frame (fh_mode=0b01): BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 25 Control frames, which are only available in header mode, are used for special or exceptional information. All control frames contribute to the fifo_byte _counter in Register (0x22-0x23) FIFO_LENGTH. In detail, there are three types of control frame, which can be distinguished by the fh_parm field: Skip frame (fh_parm=0b000): In case of a FIFO overflow, a skip frame is prepended to the FIFO content when the next readout is performed. A skip frame indicates the number of skipped frames since the last readout. In the header byte of a FIFO_input_config frame, fh_mode equals 0b01 (since it is a control frame) and the fh_param equals 0b000 (indicating FIFO_input_config frame). The data byte part of a skip frame consists of one byte and contains the number of skipped frames. When more than 0xFF frames have been skipped, 0xFF is returned. Sensortime frame (fh_parm=0b001): If the sensortime frame functionality is activated (see description of Register (0x46-0x47) FIFO_CONFIG) and the FIFO is overread, the last data frame is followed by a sensortime frame. This frame contains the BMI160 timestamp content corresponding th the time at which the last data frame was read. In the header byte of a sensortime frame, fh_mode = 0b01 (since is a control frame) and fh_param = 0b001 (indicating sensortime frame). The data byte part of a sensortime frame consists of 3 bytes and contains the 24-bit sensortime. A sensortime frame does not consume memory in the FIFO. FIFO_input_config frame (fh_parm=0b010): Whenever the configuration of the FIFO input data sources changes, a FIFO input config frame is inserted into the FIFO in front of the data to which the configuration change is applied. In the header byte of a FIFO_input_config frame, fh_mode = 0b01 (since it is a control frame) and fh_param = 0b010 (indicating FIFO_input_config frame). The data byte part of a FIFO_input_config Frame consists of one byte and contains data corresponding to the following table: Bit Content 7 reserved 6 5 mag_if_ch 4 mag_conf_ch Bit Read/Write 3 gyr_range_ch 2 gyr_conf_ch 1 acc_range_ch 0 acc_conf_ch gyr_range_ch: gyr_conf_ch: acc_range_ch: acc_conf_ch: A change in Register (0x43) GYR_RANGE becomes active. A change in Register (0x42) GYR_CONF or gyr_fifo_filt_data or gyr_fifo_downsampling in Register (0x45) FIFO_DOWNS becomes active. A change in Register (0x41) ACC_RANGE becomes active. A change in Register (0x40) ACC_CONF or acc_fifo_filt_data or acc_fifo_downsampling in Register (0x45) FIFO_DOWNS becomes active. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet mag_if_ch: mag_conf_ch: Page 26 Will be set if there are changes on interface configuration (e.g. device address, read/write address). It can be used to switch to another device or different data-set within connected device. A change in Register (0x44) MAG_CONF becomes active. 2.5.2 FIFO conditions and details 2.5.2.1 Overflows In the case of overflows the FIFO will overwrite the oldest data. A skip frame will be prepended at the next FIFO readout if the available FIFO space falls below the maximum size frame. 2.5.2.2 Overreads If more data bytes are read from the FIFO than valid data bytes are available, `0x80' is returned. Since a header `0x80' indicates an invalid frame, the SW can recognize the end of valid data. After the invalid header the data is undefined. This is valid in both headerless and header mode. In addition, if header mode and the sensortime frame are enabled, the last data frame is followed by a sensortime frame. After this frame, a 0x80 header will be returned that indicates the end of valid data. 2.5.2.3 Partial frame reads When a frame is only partially read through, it will be repeated within the next reading operation (including the header). 2.5.2.4 FIFO synchronization with external events External events can be synchronized with the FIFO data by connecting the event source to one of the BMI160 interrupt pins (which needs to be configured as an input interrupt pin). External events can be generated e.g. by a camera module. Each frame contains the value of the interrupt input pin at the time of the external event. The fh_ext<1:0> field is set when an external interrupt is triggered. External interrupt tags are configured using int_output_en in Register (0x53) INT_OUT_CTRL, int_input_en in Register (0x54) INT_LATCH and fifo_tag_int_en in Register (0x46-0x47) FIFO_CONFIG. 2.5.2.5 FIFO Reset A reset of the BMI160 is triggered by writing the opcode 0xB0 "fifo_flush" to the Register (0x7E) CMD. This will clears all data in the FIFO while keeping the FIFO settings unchanged. Automatic resets are only done in two exceptional cases where the data would not be usable without a reset: a sensor is enabled or disabled in headerless mode, a transition between headerless and headermode occurred. 2.5.2.6 Error Handling In case of a configuration error in Register (0x46-0x47) FIFO_CONFIG, no data will be written into the FIFO and the error is reported in Register (0x02) ERR_REG. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 27 2.6 Interrupt Controller There are 2 interrupt output pins, to which thirteen different interrupt signals can be mapped independently via user programmable parameters. Available interrupts supported by accelerometer in normal mode are: Any-motion (slope) detection for motion detection Significant motion Step detector Tap sensing for detection of single or double tapping events Orientation detection Flat detection for detection of a situation when one defined plane of the sensor is oriented parallel to the earth's surface Low-g/high-g for detecting very small acceleration (e.g. free-fall) or very high acceleration (e.g. shock events) No/slow-motion detection for triggering an interrupt when no (or slow) motion occurs during a certain amount of time In addition to that the common interrupts for accelerometer and gyroscope are Data ready ("new-data") for synchronizing sensor data read-out with the MCU / host controller FIFO full / FIFO watermark allows FIFO fill level and overflow handling. All Interrupts are available only in normal (low-noise) and low-power modes, but not in suspend mode. In suspend mode only the status (like orientation or flat) can be read out, but no interrupt will be triggered (unless latching is used). If latching is used the interrupts (as well as the interrupt status) will be latched also in suspend mode, but no new interrupts will be generated. Input Interrupt Pins: For special applications (e.g. PMU Trigger, FIFO Tag) interrupt pins can be configured as input pins. For all other cases (standard interrupts), the pin must be configured as an output. Note: The direction of the interrupt pins is controlled with int_output_en and int_x_input_en in Register (0x53) INT_OUT_CTRL and Register (0x54) INT_LATCH. If both are enabled, the input (e.g. marking fifo) is driven by the interrupt output. 2.6.1 Any-motion detection (Accel) The any-motion detection uses the slope between two successive acceleration signals to detect changes in motion. The interrupt is configured in the Register (0x5F-0x62) INT_MOTION. It generates an interrupt when the absolute value of the acceleration exceeds a preset threshold int_anym_th for a certain number int_anym_dur of consecutive slope data points is above the slope threshold int_anym_th. If the same number of data points falls below the threshold, the interrupt is reset. In order to avoid acceleration data saturation, when data is at maximal value (e.g. `0x8000' or `0X7FFF' for a 16 bit sensor); it is considered that the slope is at maximal value, too. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 28 acceleration acc(t0+dt) acc(t0) time slope slope(t0+dt)= acc(t0+dt) - acc(t0) anym_th time anym_dur anym_dur latched INT unlatched time Figure 5: Any-motion (slope) interrupt detection The criteria for any-motion detection are fulfilled and the slope interrupt is generated if any of the axis exceeds the threshold int_anym_th for int_anym_dur consecutive times. As soon as all the channels fall or stay below this threshold for int_anym_dur consecutive times the interrupt is reset. If this interrupt is triggered in latch mode it remains blocked (disabled) until the latching is cleared. The any-motion interrupt logic sends out the signals of the axis that has triggered the interrupt (int_anym_first_x, int_anym_first_y, int_anym_first_z) and the signal of motion direction (int_anym_sign). 2.6.2 Significant Motion (Accel) The significant motion interrupt implements the interrupt required for motion detection in Android 4.3 and greater: https://source.android.com/devices/sensors/composite_sensors.html#Significant A significant motion is a motion due to a change in the user location. Examples of such significant motions are walking or biking, sitting in a moving car, coach or train, etc. Examples of situations that should not trigger significant motion include phone in pocket and person is not moving, phone is on a table and the table shakes a bit due to nearby traffic or washing machine. The algorithm uses acceleration and performs the following steps to detect a significant motion: 1. Look for movement. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 29 2. [Movement detected] Sleep for 3 seconds. 3. Look for movement. Either option a or option b will happen: a. [One second has passed without movement] Go back to 1. b. [Movement detected] Report that a significant movement has been found and wake up the application processor. The significant motion and the anymotion interrupt are exclusive. To select the interrupt, use int_sig_mot_sel in Register (0x5F-0x62) INT_MOTION. The following block diagram illustrates the algorithm: motion detected? no yes sleep for 3s (t_skip) motion detected within 1s no yes significant motion detected no Figure 6: Block diagram of significant motion interrupt algorithm Configurable parameters are: sig_th = 0x14; // ~ 70mg same as anym_th t_skip = 0x01; // 2.56s 0=1.28s, 1=2.56s, 2=5,12s 3=10.24s t_proof = 0x02; // 0.96s 0=0.24s, 1=0.48s, 2=0.96s 3=1.92s BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 30 2.6.3 Step Detector (Accel) A step detection is the detection of a single step event, while the user is walking or running. The step detector is triggered when a peak is detected in the acceleration magnitude (vector length of 3D acceleration). In order to achieve a robust step detection the peak needs to exceed a configurable threshold min_threshold and a minimum delay time min_steptime between two consecutive peaks needs to be observed. The step detector can be configured in three modes: Normal mode (default setting, recommended for most applications) Sensitive mode (can be used for light weighted, small persons) Robust mode (can be used, if many false positive detections are observed) More details can be found in Register (0x7A-0x7B) STEP_CONF and the according step counter application note. The step detector is the trigger for a step counter. The step counter is described in more detail in chapter 2.7. 2.6.4 Tap Sensing (Accel) Double-Tap implements same functionality as two single taps in a short well-defined period of time. If the period of time is too short or too long no interrupt is fired. The interrupt is configured in the Register (0x63-0x64) INT_TAP. When the preset threshold int_tap_th is exceeded, a tap is detected and a int_s_tap_int in Register (0x1C-0x1F) INT_STATUS is set and an interrupt is fired. The double-tap interrupt is generated only when a second tap is detected within a specified period of time. In this case, the int_d_tap_int in Register (0x1C-0x1F) INT_STATUS is set. The slope between two successive acceleration data is needed to detect a tap-shock and quietperiod. The time difference between the two successive acceleration values depends on data rate selected for the interrupt source, which depends on the configured downsampling rate in Register (0x58-0x59) INT_DATA and the configured output data rate in Register (0x40) ACC_CONF, when filtered data have been selected in the Register (0x58-0x59) INT_DATA. The time delay int_tap_dur between two taps is typically between 12.5ms and 500ms. The threshold is typically between 0.7g and 1.5g in 2g measurement range. Due to different coupling between sensor and device shell (housing) and different measurement ranges of the sensor these parameters are configurable. The criteria for a double-tap are fulfilled and an interrupt is generated if the second tap occurs after int_tap_quiet and within int_tap_dur. The tap direction is determined by the 1st tap. If during int_tap_quiet period (30/20ms) a tap occurs, it will be considered as a new tap. The slope detection interrupt logic stores the direction of the (first) tap-shock in a status register. This register needs to be locked for int_tap_shock 50/75ms in order to prevent other slopes to overwrite this information. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 31 slope Second Tap First Tap tap_thh time Int_tap_shock = 50/75ms tnt_tap_quiet = 30/20ms int_tap_dur = 50 / 700 ms int_tap_shock Int_tap_quiet =50/75ms = 30/20ms single_tap_det double_tap_det time time Figure 7: Tap detection interrupt The single-tap and double-tap interrupts are enabled through the int_s_tap_en and int_d_tap_en registers. When a tap or double-tap interrupt is triggered, the signals of the axis that has triggered the interrupt (int_tap_first_x, int_tap_first_y, int_tap_first_z) and the signal of motion direction (int_tap_sign) will set in Register (0x1C-0x1F) INT_STATUS. The axis on which the biggest slope occurs will trigger the tap. The second tap will be triggered by any axis (not necessarily same as the first tap). If this interrupt is triggered in latch mode it remains blocked (disabled) until the latching is reset. 2.6.5 Orientation recognition (Accel) The orientation recognition feature informs on an orientation change of the sensor with respect to the gravitational field vector g. There are the orientations face up/face down and orthogonal to that portrait upright, landscape left, portrait downside, and landscape right. The interrupt to face up/face down may be enabled separately through int_orient_ud_en in Register (0x65-0x66) INT_ORIENT. The sensor orientation is defined by the angles phi and Theta (phi is rotation around the stationary z axis, theta is rotation around the stationary y axis). BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 32 z x y g Figure 8: definition of coordinate system with respect to pin 1 marker The measured acceleration vector components look as follows: = 1 sin cos = -1 sin sin = 1 cos (2)/(1): (1) (2) (3) = - tan Figure 9: Angle-to-Orientation Mapping BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 33 Note that the sensor measures the direction of the force which needs to be applied to keep the sensor at rest (i.e. opposite direction than g itself). Looking at the phone from frontside / portrait upright corresponds to the following angles: = 90 , = 270 The orientation value is stored in the output register int_orient in Register (0x1C-0x1F) INT_STATUS. There are three orientation calculation modes: symmetrical, high-asymmetrical and low-asymmetrical. The mode is selected by the register int_orient_mode in Register (0x650x66) INT_ORIENT as follows: Table 14: Orientation mode orient_mode Orientation mode 00 Symmetrical 01 High asymmetrical 10 Low asymmetrical 11 Symmetrical The register int_orient has the following meanings depending on the switching mode: Table 15: Symmetrical mode orient x00 x01 x10 x11 Name landscape left landscape right portrait upside down portrait upright Angle 315 in Register (0x1C-0x1F) INT_STATUS has the definition Table 18: upside and downside mode 0 upside 1 downside MSB acc_z (270 < < 90) (90 < < 270) acc_z >= 0 acc_z < 0 int_orient<2> also is computed when flat interrupt is activated. Both portrait/landscape and upside/downside recognition use a hysteresis. The hysteresis for portrait/landscape detection is configurable and applies to all conditions as described in the tables below. Table 19: Symmetrical mode orient x00 x01 x10 x11 Name landscape left Angle 315+hy |acc_x|+hyst && acc_y<0 |acc_y|>|acc_x|+hyst && acc_y0 y h -h h x -h Figure 10: Hysteresis in symmetrical mode BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 35 Table 20: High asymmetrical mode orient x00 x01 x10 x11 Name landscape left landscape right portrait upside down portrait upright Angle 297+hy 2*|acc_x|+hyst && acc_y<0 |acc_y|>2*|acc_x|+hyst && acc_y0 y h -h h x -h Figure 11: Hysteresis in high asymmetrical mode Table 21: Low asymmetrical mode orient x00 x01 x10 x11 Name landscape left landscape right portrait upside down portrait upright Angle 333+hy |acc_x|/2+hyst && acc_y<0 |acc_y|>|acc_x|/2+hyst && acc_y0 y h -h h x -h Figure 12: Hysteresis in low asymmetrical mode BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 36 The hysteresis for upside/downside detection is fixed to 11.5 which is ~200 mg (205 LSB in 2g mode and is scalable with the g range). Table 22: Upside/downside hysteresis for all 3 modes orient 0xx Name upside Angle 281.5200mg (|acc_z|>200mg and acc_z0) acc_z<-200mg (|acc_z|>200mg and acc_z<0) 2.6.5.1 Blocking It is be possible to block the orientation detection (no orientation interrupt will be triggered). The orientation interrupt blocking feature is configurable via the int_orient_blocking in Register (0x650x66) INT_ORIENT bits in the following manner: "00" Interrupt blocking is disabled "01" Interrupt blocked if device close to the horizontal position or acceleration of any axis >1.5g "10" Interrupt blocked if device close to the horizontal position or acceleration of any axis >1.5g or slope>0.2g (for 3 consecutive data samples) "11" Interrupt blocked if device close to the horizontal position or slope>0.4g or acceleration of any axis>1.5g or another orientation change within 100ms (same orientation and acc <1.5g for 100ms) For all states where interrupt blocking through slope detection is used, the interrupt is re-enabled after the slope has been below the threshold for 3 times in a row. For all states where 100ms interrupt blocking is enabled, in order to trigger the interrupt, the orientation remains the same (stable) until the timer runs out (for ~100ms). The timer starts to count when orientation changes between two consecutive samples. If the orientation changes while timer is still counting, the timer is restarted. The theta blocking (phone close to the horizontal position) is defined by the following inequality: ((theta_blk)6 * ((acc_z)SAT * (acc_z)SAT)6 )10 > ((acc_x)SAT * (acc_x)SAT)10 + ((acc_y)SAT * (acc_y)SAT)10 where: ()6 means usage of 6-bit arithmetic (6 MSBs from a value is used); ()SAT means absolute value reduced to 6 bits saturated to 1g (MSB-1 is taken as MSB, saturation arithmetic for this conversion) If other than 2g range is selected, acceleration values shall be amplified before blocking computation to have the same scale as in 2g range. 2.6.5.2 Interrupt generation and latching The orientation interrupt is triggered at every change of the int_orient status register value. If register bit int_orient_ud_en in Register (0x65-0x66) INT_ORIENT is `1', then all bits in the int_orient register, those indicating the portrait/landscape orientation, as well as those indicating the upside/downside orientation are considered for the generation of the interrupt condition. If register bit int_orient_ud_en is `0', then only the bits in the int_orient register that indicate the BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 37 portrait/landscape orientation are considered for the generation of the interrupt condition, while those bits indicating the upside/downside orientation are ignored. The bit indicating upside/downside orientation is int_orient<2>, while the bit-field indicating the portrait/landscape orientation is int_orient<1:0>. If orient_ud_en is `0' then the int_orient<2> status bit is 0. In case the orientation interrupt condition has been satisfied the orientation relevant fields in Register (0x1C-0x1F) INT_STATUS are updated. 2.6.5.3 Rotation of the Reference Coordinate System The given specification is valid for an upright mounted PCB. In order to also enable horizontal mounting, x and z axis can be exchanged via the register int_axes_ex for the flat and orientation interrupt. For all other interrupts and in all other functions, e.g. data registers and FIFO, the x, y, and z axes will not be affected. The x-, y-, z-axis will keep right-hand principle after the exchange 2.6.6 Flat Detection (Accel) This interrupt detects flat orientation. This interrupt fires when the device gets into horizontal position (int_flat=1 e.g. it is being placed on a table) or when it goes out of it (int_flat=0 e.g. it is picked up). The interrupt is configured in the Register (0x67-0x68) INT_FLAT. The condition for activating the interrupt is: [((theta_flat)6 * ((acc_z)SAT*(acc_z)SAT )6 )10 - ("000000" & int_flat_hy) >= ((acc_x)SAT*(acc_x)SAT )10 + ((acc_y)SAT * (acc_y)SAT )10 AND (no_movement) The condition to deactivate the interrupt in non-latched mode is: [((theta_flat)6 * ((acc_z)SAT*(acc_z)SAT )6 )10 + ("000000" & int_flat_hy) < ((acc_x)SAT*(acc_x)SAT )10 + ((acc_y)SAT * (acc_y)SAT )10] OR NOT (no_movement) no_movement is "0" if slope > 0.2g for 3 consecutive samples when orient_blocking = "10" no_movement is "0" if slope > 0.4g for 3 consecutive samples when orient_blocking = "11" If no_movement is "1", then flat interrupt is reset. Theta Figure 13: Flat Orientation Angles BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 38 Before the interrupt is actually fired, the device must remain flat for a certain period (e.g. int_flat_hold_time = 1s). Note: Rotation of the Reference Coordinate System is possible for the Flat interrupt, see chapter 2.6.5.3. 2.6.7 Low-g / free-fall Detection (Accel) For freefall detection, the absolute values of the acceleration data of all axes are observed (global criteria). A sum of the absolute values of all accelerations |acc_x| + |acc_y| + |acc_z| is compared with the threshold int_low_th. The interrupt will be generated if the threshold is exceeded and the measured acceleration stays below the hysteresis level int_low_th+int_low_hy for some minimum number of samples (int_low_dur). acceleration low_th + low_hy low_th time counter value low_dur time INT latched non-latched time Figure 14: Free-fall detection 2.6.8 High-g detection (Accel) This interrupt is configured in the Register (0x5A-0x5E) INT_LOWHIGH. The interrupt is asserted if the absolute value of acceleration data of at least one enabled axis exceeds the programmed threshold int_high_th and the sign of the value does not change for a minimum duration of int_high_dur. The interrupt condition is cleared when the absolute value of acceleration data of all selected axes falls below the threshold int_high_th minus the hysteresis int_high_hy or if the sign of the acceleration value changes. The X, Y and Z axes are enabled with the int_high_en_x, int_high_en_y, and int_high_en_z, respectively. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 39 When the high-g interrupt is triggered, the signals of the axis that has triggered the interrupt (int_high_first_x, int_high_first_y, int_high_first_z) and the motion direction (int_high_sign) are set in the Register (0x1C-0x1F) INT_STATUS. If this interrupt is triggered in latch mode it stays blocked (disabled) until the latching is cleared. acceleration high_th time -high_th counter high_dur time INT high_dur latched time non-latched Figure 15: Free-fall detection 2.6.9 Slow-Motion Alert / No-Motion Interrupt (Accel) This interrupt engine monitors the slopes of each axis. The interrupt is configured in the Register (0x5F-0x62) INT_MOTION. It behaves similar to the any-motion interrupt, but with a different set of the parameters. As the only difference between the slow-motion interrupt and the any-motion interrupt, the slow-motion engine doesn't store the information which axis has triggered the interrupt and in which direction. The slow-motion/no-motion interrupt engine can be configured in two modes. It can act as an interrupt very similar to the any-motion interrupt, where the slope on the selected axis is monitored and an interrupt is generated when a slope threshold is exceeded for a programmable number of samples. The figure below illustrates the operation of the slow-motion interrupt engine in terms of relevant signals and timing. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 40 acceleration acc(t0+t) acc(t0) time slope slope(t0+t)= acc(t0+t) - acc(t0) slo_no_mot_t h time INT slo_no_mot_d ur slo_no_mot_d ur latched unlatche d time Figure 16: Slow motion, no motion The interrupt engine can also be configured as a no-motion interrupt, where an interrupt is generated when the slope on all selected axis remains smaller than a programmable threshold for a programmable time. In order to save register space, some configuration registers have different interpretations depending on the selected mode. The signals and timings relevant to the no-motion interrupt functionality are depicted in the figure below. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet acceleration Page 41 acc(t0+t) acc(t0) axis x, y, or z slope slope(t0+t)= acc(t0+t) - acc(t0) axis x, y, or z slo_no_mot_th -slo_no_mot_th slo_no_mot_dur timer INT time Figure 17: Signal timings no motion interrupt The figure below shows the differences in the logic operation between the slow-motion and nomotion interrupt functionality. Slow-Motion Interrupt Mode slo_no_mot_en_z slope_z Slow-Motion > Interrupt Mode slo_no_mot_en_y slope_y > slo_no_mot_en_z slope_z slope_x > slo_no_mot_en_x > slo_no_mot_en_y slope_y > slo_no_mot_th slo_no_mot_en_x slope_x > Counter slo_no_mot_dur Counter INT INT Figure 18: Slow motion interrupt mode slo_no_mot_dur No-Motion Interrupt Mode slo_no_mot_th slo_no_mot_en_z slope_z > No-Motion Interrupt Mode slo_no_mot_en_y slope_y > slo_no_mot_en_z slope_z > slo_no_mot_en_x slope_x > slo_no_mot_en_y slope_y > slo_no_mot_th slo_no_mot_en_x slope_x > slo_no_mot_th Timer INT Timer slo_no_mot_dur INT slo_no_mot_dur Figure 19: No motion interrupt mode BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 42 2.6.9.1 Register slo_no_mot_dur The meaning of register int_slo_no_mot_dur changes depending on the state of the no_mot_sel configuration bit. If int_no_mot_sel ='0', register int_slo_no_mot_dur defines the number of consecutive slope data points of the selected axis which must exceed the threshold value int_slo_no_mot_th for an interrupt to be asserted. The functionality is compliant to the original slow-motion interrupt and also the any-motion interrupt. Register (0x5F-0x62) INT_MOTION lists the relationship between the setting of int_slo_no_mot_dur and the number of slope data points filtered prior to asserting the interrupt. However, if no_mot_sel ='1', register int_slo_no_mot_dur defines the time no slope data point of any of the selected axis must exceed the threshold value int_slo_no_mot_th for an interrupt to be asserted. The tick times of 1.28s, 5.12s and 10.24s depend on the value programmed into int_slo_no_mot_dur<5:0>. By means of using variable tick times, a no-motion delay between 1s and 430s may be adjusted with a register with a width of six bits. 2.6.9.2 Register slo_no_mot_th The int_slo_no_mot_th register defines the threshold against which the calculated slope values of each axis are compared. The scaling is independent on the selected interrupt mode. The user must scale the int_slo_no_mot_th value according to the adjusted range. 2.6.10 Data Ready Detection (Accel, Gyro and external sensors) This interrupt fires whenever a new data sample from accel and gyro is complete. This allows a low latency data readout. The data update detection monitors the data_update signals for all axes and sensors. It generates an interrupt as soon as the values for all axes and sensors which are required for the configured output data rates have been updated. The interrupt is cleared automatically when the update for the next sample starts or the data is read out from the data register. 2.6.11 PMU Trigger (Gyro) Whenever a PMU (power management unit) trigger (either wakeup or sleep) is issued, wakeup_int in Register (0x6C) PMU_TRIGGER configures if an interrupt is send to the application processor. If the AP wants to trigger sleeps itself for the gyro, the gyr_wakeup_trigger is configured accordingly and no wakeup triggers are issued. The PMU trigger interrupt is from the system perspective used in a similar manner as the anymotion and nomotion interrupts. The PMU trigger interrupt follows the Register (0x54) INT_LATCH configuration for resetting the interrupt. 2.6.12 FIFO Interrupts (Accel, Gyro, and external sensors) The FIFO supports two interrupts, a FIFO full interrupt and a watermark interrupt. The FIFO full interrupt is issued when the FIFO is full and the next full data sample would cause a FIFO overflow, which may lead to samples being deleted. Technically, that means that a FIFO full interrupt is issued, whenever less space than two maximum size frames is left in the FIFO. The FIFO watermark interrupt is fired, when the FIFO fill level in fifo_byte_counter in Register (0x220x23) FIFO_LENGTH is above a pre-configured watermark, defined in fifo_watermark in Register (0x46-0x47) FIFO_CONFIG. Note: The unit of fifo_watermark is 4 bytes whereas the unit of fifo_byte_counter is single bytes. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 43 2.7 Step Counter The step counter implements the function required for step counting in Android 4.4 and greater: https://source.android.com/devices/sensors/sensor-types#step_counter The step counter accumulates the steps detected by the step detector interrupt. Based on more sophisticated algorithms, the step counter features a higher accuracy and reporting latency than the step detector interrupt described in Chapter 2.6.3. The step counter is configurable to the following modes through the step detector settings: Normal mode (default setting, recommended for most applications) Sensitive mode (can be used for light weighted, small persons) Robust mode (can be used, if many false positive detections are observed) In order to read out the step counter values it is recommended to switch to normal mode The step counter is enabled and reset with step_cnt_en in Register (0x7A-0x7B) STEP_CONF. It shares its configuration with the step detector interrupt in Register (0x7A-0x7B) STEP_CONF. The step counter can be used in low-power mode. In order to receive the most recent number of counted steps, it is recommended to switch to normal mode prior to reading out the Register (0x78-0x79) STEP_CNT. More details can be found in the step counter field test report. 2.8 Device self test This feature permits to check the sensor functionality via a built-in self-test (BIST). The accelerometer has a comprehensive self test function for the MEMS element, the gyroscope implements a simple self-test/life-test. 2.8.1 Self-test accelerometer By applying electrostatic forces to the sensor core instead of external accelerations, the entire signal path of the sensor can be tested. Activating the self-test results in a static offset of the acceleration data; any external acceleration or gravitational force applied to the sensor during active self-test will be observed in the output as a superposition of both acceleration and self-test signal. All three axes are activated at the same time. Before the self-test is enabled the g-range should be set to 8 g. The Register (0x40) ACC_CONF has to be set to value 0x2C (acc_odr=1600Hz; acc_bwp=2; acc_us=0). Otherwise the accelerometer self-test mode will not function correctly. The self-test is activated by writing the value 0b01 to the acc_self_test_enable bits in the Register (0x6D) SELF_TEST. It is possible to control the direction of the deflection of all 3 axes through the bit acc_self_test_sign. The excitations occurs in negative (positive) direction if self_test_sign = 0b0 (0b1). The amplitude of the deflection has to be set high by writing acc_self_test_amp=0b1. After the self-test is enabled, the user should wait 50 ms before interpreting the acceleration data BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 44 In order to ensure a proper interpretation of the self-test signal it is recommended to perform the self-test for both (positive and negative) directions and then to calculate the difference of the resulting acceleration values. The table below shows the minimum absolute differences for each axis. The actually measured absolute signal differences can be significantly larger. Table 23: Accelerometer self test minimum difference values Minimum difference signal x-axis signal y-axis signal z-axis signal 2g 2g 2g It is recommended to perform a reset of the device after a self-test has been performed. If the reset cannot be performed, the following sequence must be kept to prevent unwanted interrupt generation: disable interrupts, change parameters of interrupts, wait for at least 50ms, enable desired interrupts. 2.8.2 Self-test gyroscope The gyroscope BIST can be triggered during normal operation mode. It checks the sensors drive amplitude, its frequency and the stability of the drive control loop. Hence, disturbances of the movement by particles, mechanical damage or pressure loss can be detected. The self-test for the gyroscope will be started by writing a `1' to gyr_self_test_enable in Register (0x6D) SELF_TEST. The result will be in gyr_self_test_ok in Register (0x1B) STATUS. In addition, any particles or damages can be easily identified in a Manual Performance Check". Due to the outstanding offset and noise performance the measured values at zero-rate fit the specified performance. 2.9 Offset Compensation BMI160 offers fast and manual compensation as well as inline calibration. Fast offset compensation is performed with pre-filtered data, and the offset is then applied to both, pre-filtered and filtered data. If necessary the result of this computation is saturated to prevent any overflow errors (the smallest or biggest possible value is set, depending on the sign). The public offset compensation Register (0x71-0x77) OFFSET are images of the corresponding registers in the NVM. With each image update (see chapter 2.10 for details) the contents of the NVM registers are written to the public registers. The public registers can be overwritten by the user at any time. Offset compensation needs to be enabled through gyr_off_en and acc_off_en in Register (0x71-0x77) OFFSET. 2.9.1 Fast offset compensation Fast offset compensation (FOC) is a one-shot process that compensates offset errors of accelerometer and gyro by setting the offset compensation registers to the negated offset error. This is best suited for "end-of-line trimming" with the customers device positioned in a well-defined orientation. Before triggering, the FOC needs to be configured via the Register (0x69) FOC_CONF. Accelerometer and gyroscope FOC can be separately disabled or enabled. Gyroscope target BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 45 value is always 0 dps, for the accelerometer the target value has to be defined for each channel (-1g, 0g, +1g) depending on sensor position relative to the earth gravity field. FOC is triggered by issuing a start_foc command to Register (0x7E) CMD. Once triggered, the status of the fast correction process is reflected in the status bit foc_rdy in Register (0x1B) STATUS. Foc_rdy is `0' while the measurement is in progress. Accelerometer and gyroscope values are measured with preset filter settings. This will take a maximum time of 250 ms. The negated measured values are written to Register (0x71-0x77) OFFSET automatically (overwriting previous offset register values), cancelling out offset errors if "gyr_off_en" and "acc_off_en" in Register (0x71-0x77) OFFSET are activated. For the accelerometer offset, the accuracy is 3.9 mg. Fast compensation should not be used in combination with the low-power mode. In low-power mode the conditions (availability of necessary data) for proper function of fast compensation are not fulfilled. Fast offset compensation does not clear the data ready bit in Register (0x1B) STATUS. It is recommended to read the Register (0x04-0x17) DATA after FOC completes, to remove a stall data ready bit from before the FOC. 2.9.2 Manual offset compensation The contents of the public compensation Register (0x71-0x77) OFFSET may be set manually via the digital interface. After modifying the Register (0x71-0x77) OFFSET the next data sample is not valid. Writing to the offset compensation registers is not allowed while the fast compensation procedure is running. "gyr_off_en" and "acc_off_en" in Register (0x71-0x77) OFFSET need to be activated as well. 2.9.3 Inline calibration For certain applications, it is often desirable to calibrate the offset once and to store the compensation values permanently. This can be achieved by using fast or manual offset compensation to determine the proper compensation values and then storing these values permanently in the NVM. Each time the device is reset, the compensation values are loaded from the non-volatile memory into the image registers and used for offset compensation. 2.10 Non-Volatile Memory The entire memory of the BMI160 consists of volatile and non-volatile registers. Part of it can be both read and written by the user. Access to non-volatile memory is only possible through (volatile) image registers. We support a maximum number of write cycles equal or less than 14. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 46 The Register (0x70) NV_CONF and Register (0x71-0x77) OFFSET have an NVM backup which is accessible by the user. The content of the NVM is loaded to the image registers after a reset (either POR or softreset). As long as the image update is in progress, bit nvm_rdy in Register (0x1B) STATUS is 0, otherwise it is 1. The image registers can be read and written like any other register. Writing to the NVM is a three-step procedure: Write the new contents to the image registers. Write 1 to bit nvm_prog_en in the Register (0x6A) CONF register in order to unlock the NVM. Write prog_nvm (0xA0) to the Register (0x7E) CMD to trigger the write process. Writing to the NVM always renews the entire NVM contents. It is possible to check the write status by reading bit nvm_rdy. While nvm_rdy = 0, the write process is still in progress; if nvm_rdy = 1, then writing is completed. As long as the write process is ongoing, no change of power mode and image registers is allowed. An NVM write cycle can only be initiated, when the accelerometer is in normal mode. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 47 2.11 Register Map This chapter contains register definitions. REG[x] denotes bit y in byte x in register REG. Val(Name) is the value contained in the register interpreted as non-negative binary number. When writing to reserved bits, `0' should be written when not stated different. Read/write Register Name read only Register Address 0x7E 0x7D 0x7C 0x7B 0x7A 0x79 0x78 0x77 0x76 0x75 0x74 0x73 0x72 0x71 0x70 0x6F 0x6E 0x6D CMD STEP_CONF_1 STEP_CONF_0 STEP_CNT_1 STEP_CNT_0 OFFSET_6 OFFSET_5 OFFSET_4 OFFSET_3 OFFSET_2 OFFSET_1 OFFSET_0 NV_CONF SELF_TEST Default Value 0x00 0x03 0x15 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x6C 0x6B 0x6A 0x69 0x68 0x67 0x66 PMU_TRIGGER IF_CONF CONF FOC_CONF INT_FLAT_1 INT_FLAT_0 INT_ORIENT_1 0x00 0x00 0x00 0x00 0x11 0x08 0x48 0x65 0x64 0x63 0x62 INT_ORIENT_0 INT_TAP_1 INT_TAP_0 INT_MOTION_3 0x18 0x0A 0x04 0x24 0x61 0x60 0x5F 0x5E 0x5D 0x5C 0x5B 0x5A 0x59 0x58 INT_MOTION_2 INT_MOTION_1 INT_MOTION_0 INT_LOWHIGH_4 INT_LOWHIGH_3 INT_LOWHIGH_2 INT_LOWHIGH_1 INT_LOWHIGH_0 INT_DATA_1 INT_DATA_0 0x14 0x14 0x00 0xC0 0x0B 0x81 0x30 0x07 0x00 0x00 0x57 0x56 0x55 0x54 0x53 0x52 0x51 0x50 INT_MAP_2 INT_MAP_1 INT_MAP_0 INT_LATCH INT_OUT_CTRL INT_EN_2 INT_EN_1 INT_EN_0 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x4F 0x4E 0x4D 0x4C MAG_IF_4 MAG_IF_3 MAG_IF_2 MAG_IF_1 0x00 0x4C 0x42 0x80 0x4B 0x4A 0x48 0x47 0x46 0x45 MAG_IF_0 FIFO_CONFIG_1 FIFO_CONFIG_0 FIFO_DOWNS 0x20 0x10 0x80 0x88 0x44 0x43 0x42 0x41 MAG_CONF GYR_RANGE GYR_CONF ACC_RANGE 0x0B 0x00 0x28 0x03 bit7 bit6 write only bit5 bit4 reserved bit3 bit2 bit1 bit0 cmd reserved reserved reserved step_cnt_en step_conf_10_8 step_conf_7_0 step_cnt_15_8 step_cnt_7_0 gyr_off_en acc_off_en off_gyr_z_9_8 off_gyr_y_9_8 off_gyr_x_9_8 off_gyr_z_7_0 off_gyr_y_7_0 off_gyr_x_7_0 off_acc_z off_acc_y off_acc_x reserved u_spare_0 i2c_wdt_en i2c_wdt_sel spi_en reserved reserved reserved gyr_self_test_ acc_self_test_ acc_self_test_ acc_self_test_enable enable amp sign reserved wakeup_int gyr_sleep_state gyr_wakeup_trigger gyr_sleep_trigger reserved if_mode reserved spi3 reserved nvm_prog_en reserved reserved foc_gyr_en foc_acc_x foc_acc_y foc_acc_z reserved int_flat_hold reserved int_flat_hy reserved int_flat_theta int_orient_axes int_orient_ud_ int_orient_theta _ex en int_orient_hy int_orient_blocking int_orient_mode reserved int_tap_th int_tap_quiet int_tap_shock reserved int_tap_dur reserved int_sig_mot_proof int_sig_mot_skip int_sig_mot_ int_slo_nomo_ sel sel int_slo_nomo_th int_anymo_th int_slo_nomo_dur int_anym_dur int_high_th int_high_dur int_high_hy reserved int_low_hy int_low_th int_low_dur int_motion_src reserved int_low_high_sr reserved int_tap_src reserved c int2_flat int2_orient int2_s_tap int2_d_tap int2_nomotion int2_anymotion int2_highg int2_lowg_step int1_drdy int1_fwm int1_ffull int1_pmu_trig int2_drdy int2_fwm int2_ffull int2_pmu_trig int1_flat int1_orient int1_s_tap int1_d_tap int1_nomotion int1_anymotion int1_highg int1_lowg_step reserved int2_input_en int1_input_en int_latch int2_output_en int2_od int2_lvl int2_edge_ctrl int1_output_en int1_od int1_lvl int1_edge_ctrl reserved int_step_det_en int_nomoz_en int_nomoy_en int_nomox_en reserved int_fwm_en int_ffull_en int_drdy_en int_low_en int_highg_z_en int_highg_y_en int_highg_x_en int_flat_en int_orient_en int_s_tap_en int_d_tap_en reserved int_anymo_z_ int_anymo_y_ int_anymo_x_ en en en write_data write_addr read_addr mag_manual_ reserved mag_offset mag_rd_burst en i2c_device_addr reserved reserved reserved fifo_gyr_en fifo_acc_en fifo_mag_en fifo_header_en fifo_tag_int1_en fifo_tag_int2_en fifo_time_en reserved fifo_water_mark acc_fifo_filt_ acc_fifo_downs gyr_fifo_filt_ gyr_fifo_downs data data reserved mag_odr reserved gyr_range reserved gyr_bwp gyr_odr reserved acc_range BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet acc_us Page 48 0x40 0x3F 0x25 0x24 0x23 0x22 0x21 0x20 0x1F 0x1E 0x1D 0x1C 0x1B ACC_CONF FIFO_DATA FIFO_LENGTH_1 FIFO_LENGTH_0 TEMPERATURE_1 TEMPERATURE_0 INT_STATUS_3 INT_STATUS_2 INT_STATUS_1 INT_STATUS_0 STATUS 0x28 0x00 0x00 0x00 0x80 0x00 0x00 0x00 0x00 0x00 0x01 acc_bwp acc_odr 0x1A 0x19 0x18 0x17 SENSORTIME_2 SENSORTIME_1 SENSORTIME_0 DATA_19 0x00 0x00 0x00 0x00 0x16 DATA_18 0x00 acc_z_7_0 0x15 DATA_17 0x00 acc_y_15_8 0x14 DATA_16 0x00 acc_y_7_0 0x13 DATA_15 0x00 acc_x_15_8 0x12 DATA_14 0x00 acc_x_7_0 0x11 DATA_13 0x00 gyr_z_15_8 reserved reserved fifo_data reserved flat tap_sign nomo_int flat_int drdy_acc orient_2 tap_first_z fwm_int orient_int drdy_gyr fifo_byte_counter_10_8 fifo_byte_counter_7_0 temperature_15_8 temperature_7_0 orient_1_0 high_sign high_first_z high_first_y high_first_x tap_first_y tap_first_x anym_sign anym_first_z anym_first_y anym_first_x ffull_int drdy_int lowg_int highg_int reserved s_tap_int d_tap_int pmu_trigger_int anym_int sigmot_int step_int drdy_mag nvm_rdy foc_rdy mag_man_op gyr_self_test_ reserved ok sensor_time_23_16 sensor_time_15_8 sensor_time_7_0 acc_z_15_8 0x10 DATA_12 0x00 gyr_z_7_0 0x0F DATA_11 0x00 gyr_y_15_8 0x0E DATA_10 0x00 gyr_y_7_0 0x0D DATA_9 0x00 gyr_x_15_8 0x0C DATA_8 0x00 gyr_x_7_0 0x0B DATA_7 0x00 rhall_15_8 0x0A DATA_6 0x00 rhall_7_0 0x09 DATA_5 0x00 mag_z_15_8 0x08 DATA_4 0x00 mag_z_7_0 0x07 DATA_3 0x00 mag_y_15_8 0x06 DATA_2 0x00 mag_y_7_0 0x05 DATA_1 0x00 mag_x_15_8 0x04 DATA_0 0x00 0x03 PMU_STATUS 0x00 0x02 ERR_REG 0x00 0x01 - - reserved 0x00 CHIP_ID 0xD1 chip_id mag_x_7_0 reserved mag_drdy_err drop_cmd_err acc_pmu_status gyr_pmu_status i2c_fail_err err_code mag_pmu_status fatal_err Figure 20: BMI160 register map BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 49 2.11.1 Register (0x00) CHIPID ADDRESS 0x00 RESET na MODE R DESCRIPTION The register contains the chip identification code. DEFINITION Name Bit Read/Write Reset Value Content 7 R 1 chip_id<7:4> Bit Read/Write Reset Value Content 3 R 0 chip_id<3:0> Register (0x00) CHIPID 6 5 R R 1 0 4 R 1 2 R 0 0 R 1 1 R 0 2.11.2 Register (0x02) ERR_REG ADDRESS 0x02 RESET 0b00000000 MODE RW DESCRIPTION Reports sensor error flags. Flags are reset when read. DEFINITION Bit 7 6 5 4:1 0 Acronym Reserved drop_cmd_err Reserved error_code fatal_err BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Definition Dropped command to Register 0000: no error 0001: error 0010: error 0011: low-power mode and interrupt uses prefiltered data 0100: reserved 0101: reserved 0110: ODRs of enabled sensors in header-less mode do not match 0111: pre-filtered data are used in low power mode 1000-1111: reserved The first reported error will be shown in the error code. Chip not operable Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 50 The register is meant for debug purposes, not for regular verification if an operation completed successfully. Extensions under consideration: fatal_err: Error during bootup. Broken hardware (e.g. NVM error, see ASIC spec for details). This flag will not be cleared after reading the register. The only way to clear the flag is a POR. Acc_conf_err: Accelerometer ODR and BW not compatible gyr_conf_err: Gyroscope ODR and BW not compatible Error flags (bits 7:4) store error event until they are reset by reading the register. 2.11.3 Register (0x03) PMU_STATUS ADDRESS 0x03 RESET 0b0000-0000 MODE R DESCRIPTION Shows the current power mode of the sensor. DEFINITION Name Bit Read/Write Reset Value Content 7 R 1 reserved Bit 3 Read/Write R Reset Value 0 Content gyr_pmu_status Register (0x03) PMU_STATUS 6 5 R R 0 0 acc_pmu_status 4 R 0 2 R 0 0 R 0 1 R 0 mag_pmu_status acc_pmu_status 0b00 0b01 0b10 Accel Mode Suspend Normal Low Power gyr_pmu_status 0b00 0b01 0b10 0b11 Gyro Mode Suspend Normal Reserved Fast Start-Up mag_pmu_status 0b00 0b01 0b10 Magnet Mode Suspend Normal Low Power BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 51 The register reflects the current power modes of all sensor configured as soon as they are effective. If a sensor is enabled, the new sensor mode is reported as soon as the MEMS is up and before digital filters have settled. The settling time depends on filter settings. The power modes may be changed through the Register (0x7E) CMD. In addition, for the gyroscope through register events may be defined, which change the gyro power mode. In low power mode the FIFO is not accessible. For read outs of the FIFO the sensor has to be set to normal mode, after read-out the sensor can be set back to low power mode. 2.11.4 Register (0x04-0x17) DATA ADDRESS 0x04 (20 byte) RESET (BYTEWISE) 0b0000-0000 MODE R DESCRIPTION Register for accelerometer, gyroscope and magnetometer data. DATA[0-19] are treated as atomic update unit with respect to an I2C/SPI operation. A read operation on the Register (0x04-0x17) DATA resets the appropriate *_drdy bits in Register (0x1B) STATUS. E.g. when only [0] is read, only drdy_gyr is reset. DEFINITION DATA[0-19] contains the latest data for the x, y, and z axis of magnetometer MAG_[X-Z], gyroscope GYR_[X-Z], and accelerometer ACC_[X-Z]. The rationale for the ordering is the probability for these configurations is decreasing Readout of accel and sensortime Readout of gyro, accel, and sensortime Readout of magnetometer, gyro, accel, and sensortime Readout of magnetometer, accel, and sensortime If the secondary interface is in OIS mode, from the OIS interface the OIS data are accessible through Register (0x04-0x17) DATA [8-13]. REG (0x04 - 0x17) 0x04 0x05 0x06 0x07 0x08 0x09 0x0A 0x0B 0x0C 0x0D 0x0E 0x0F 0x10 0x11 0x12 0x13 0x14 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 DATA[X] X=0 X=1 X=2 X=3 X=4 X=5 X=6 X=7 X=8 X=9 X=10 X=11 X=12 X=13 X=14 X=15 X=16 Acronym MAG_X<7:0> (LSB) MAG_X<15:8> (MSB ) MAG_Y<7:0> (LSB) MAG_Y<15:8> (MSB) MAG_Z<7:0> (LSB) MAG_Z<15:8> (MSB) RHALL<7:0> (LSB) RHALL<15:8> (MSB) GYR_X<7:0> (LSB) GYR_X<15:8> (MSB) GYR_Y<7:0> (LSB) GYR_Y<15:8> (MSB) GYR_Z<7:0> (LSB) GYR_Z<15:8> (MSB) ACC_X<7:0> (LSB) ACC_X<15:8> (MSB) ACC_Y<7:0> (LSB) Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet 0x15 0x16 0x17 Page 52 X=17 X=18 X=19 ACC_Y<15:8> (MSB) ACC_Z<7:0> (LSB) ACC_Z<15:8> (MSB) 2.11.5 Register (0x18-0x1A) SENSORTIME ADDRESS 0x18 (3 byte) RESET 0x0000 MODE R DESCRIPTION Sensortime is a 24 bit counter available in suspend, low power, and normal mode. The value of the register is shadowed when it is read in a burst read with the data register at the beginning of the operation and the shadowed value is returned. When the FIFO is read the register is shadowed whenever a new frame is read. DEFINITION The sensortime increments with 39 s. The accuracy of the counter is the same as for the output data rate as described in section 2.3. The sensortime is unique for approx. 10 min and 54 seconds. I.e. the register value starts at 0x000000 and wraps after 0xFFFFFF has been reached. Name Bit Read/Write Reset Value Content 7 W 0 sensor_time<7:4> Bit Read/Write Reset Value Content 3 R/W 0 sensor_time<3:0> Name Bit Read/Write Reset Value Content Register (0x18-0x1A) SENSORTIME [1] 7 6 5 4 W R/W R/W R/W 0 0 0 0 sensor_time<15:11> Bit Read/Write Reset Value Content 3 2 R/W R/W 0 0 sensor_time<10:8> Name Bit Read/Write Reset Value Content Register (0x18-0x1A) SENSORTIME [2] 7 6 5 4 W R/W R/W R/W 0 0 0 0 sensor_time<23:19> BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Register (0x18-0x1A) SENSORTIME [0] 6 5 4 R/W R/W R/W 0 0 0 2 R/W 0 1 R/W 0 1 R/W 0 0 R/W 0 0 R/W 0 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Bit Read/Write Reset Value Content 3 2 R/W R/W 0 0 sensor_time<19:16> Page 53 1 R/W 0 0 R/W 0 2.11.6 Register (0x1B) STATUS ADDRESS 0x1B RESET 0b00000000 MODE R DESCRIPTION Reports sensor status flags. DEFINITION Bit 7 6 5 4 3 2 Acronym drdy_acc drdy_gyr drdy_mag nvm_rdy foc_rdy mag_man_op 1 gyr_self_test_ok Drdy_*: Nvm_rdy: foc_rdy: Definition Data ready (DRDY) for accelerometer in register Data ready (DRDY) for gyroscope in register Data ready (DRDY) for magnetometer in register NVM controller status FOC completed `0' indicates no manual magnetometer interface operation `1' indicates a manual magnetometer interface operation triggered via MAG_IF[2] or MAG_IF[3] `0' when gyroscope self-test is running or failed. `1' when gyroscope self-test completed successfully. gets reset when one byte of the register for sensor * is read. status of NVM controller: 0 NVM write operation is in progress; 1 NVM is ready to accept a new write trigger Fast offset compensation completed 2.11.7 Register (0x1C-0x1F) INT_STATUS ADDRESS 0x1C (4 byte) RESET MODE R DESCRIPTION The register contains interrupt status flags. DEFINITION Each flag is associated with a specific interrupt function. It is set when the associated interrupt triggers. The setting of Register (0x54) INT_LATCH <3:0> controls if the interrupt signal and hence the respective interrupt flag will be permanently latched, temporarily latched or not latched. The interrupt function associated with a specific status flag must be enabled. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Register (0x1C-0x1F) INT_STATUS [0] 7 6 5 4 3 2 1 0 `0' interrupt inactive, `1' interrupt active. Page 54 Acronym flat_int orient_int s_tap_int d_tap_int pmu_trigger_int anym_int sigmot_int definition Flat interrupt Orientation interrupt Single tap interrupt Double tap interrupt pmu trigger interrupt Anymotion Significant motion interrupt step_int Step detector interrupt Register (0x1C-0x1F) INT_STATUS [1] 7 6 5 4 3 2 1 0 nomo_int fwm_int ffull_int drdy_int lowg_int highg_z_int definition Nomotion Fifo watermark Fifo full Data ready Low g High g Reserved Reserved `0' interrupt inactive, `1' interrupt active. Register (0x1C-0x1F) INT_STATUS [2] 7 tap_sign 6 tap_first_z 5 tap_first_y 4 tap_first_x 3 anym_sign 2 anym_first_z 1 anym_first_y 0 anym_first_x BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Definition sign of single/double tap triggering signal was `0'positive / `1' negative single/double tap interrupt: `1' triggered by, or `0'not triggered by z-axis single/double tap interrupt: `1' triggered by, or `0'not triggered by y-axis single/double tap interrupt: `1' triggered by, or `0'not triggered by x-axis slope sign of slope tap triggering signal was `0'positive, or `1' negative Anymotion interrupt: `1' triggered by, or `0'not triggered by z-axis Anymotion interrupt: `1' triggered by, or `0'not triggered by y-axis Anymotion interrupt: `1' triggered by, or `0'not triggered by z-axis Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Register (0x1C-0x1F) acronym INT_STATUS [3] 7 flat 6 orient<2> <5:4> orient<1:0> 3 high_sign 2 high_first_z 1 high_first_y 0 high_first_x Page 55 definition device is in `1' flat, or `0' non flat position; only valid if (0x16) int_flat_en = `1' Orientation value of z-axis: 0 upward looking, or 1 downward looking. The flag always reflect the current orientation status, independent of the setting of <3:0>. The flag is not updated as long as an orientation blocking condition is active. orientation value of xx-y-plane: `00'portrait upright; `01'portrait upside down; `10'landscape left; `11'landscape right; The flags always reflect the current orientation status, independent of the setting of <3:0>. The flag is not updated as long as an orientation blocking condition is active. sign of acceleration signal that triggered high-g interrupt was `0'positive, `1' negative high-g interrupt: `1' triggered by, or `0'not triggered by z-axis high-g interrupt: `1' triggered by, or `0'not triggered by y-axis high-g interrupt: `1' triggered by, or `0'not triggered by x-axis The status bits in [2] and [3] are only meaningful if the corresponding interrupt in [0] or [1] is active. 2.11.8 Register (0x20-0x21) TEMPERATURE ADDRESS 0x20 (2 byte) RESET na MODE R DESCRIPTION Contains the temperature of the sensor DEFINITION The temperature is disabled when all sensors are in suspend mode. The output word of the 16bit temperature sensor is valid if the gyroscope is in normal mode, i.e. gyr_pmu_status=0b01. The resolution is typically 1/29 K/LSB. The absolute accuracy of the temperature is in the order of Value Temperature 0x7FFF 87 - 1/29 C ... ... 0x0000 23 C ... ... 0x8001 -41 + 1/29 C 0x8000 Invalid If the gyroscope is in normal mode (see Register (0x03) PMU_STATUS), the temperature is updated every 10 ms (+-12%). If the gyroscope is in suspend mode or fast-power up mode, the BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 56 temperature is updated every 1.28 s aligned with bit 15 of the Register (0x20-0x21) TEMPERATURE. 2.11.9 Register (0x22-0x23) FIFO_LENGTH ADDRESS 0x22 (2 byte) RESET see definition MODE see definition DESCRIPTION FIFO data readout register. DEFINITION The register contains FIFO status flags. Name Bit Read/Write Reset Value Content Register (0x22-0x23) FIFO_LENGTH [0] 7 6 5 4 R R R R n/a n/a n/a n/a fifo_byte_counter<7:4> Bit Read/Write Reset Value Content 3 2 R R n/a n/a fifo_byte_counter<3:0> Name Bit Read/Write Reset Value Content 7 R n/a Reserved Bit Read/Write Reset Value Content 3 R n/a reserved 1 R n/a 0 R n/a Register (0x22-0x23) FIFO_LENGTH [1] 6 5 4 R R R n/a n/a n/a 2 1 R R n/a n/a fifo_byte_counter<10:8> 0 R n/a fifo_byte_counter: Current fill level of FIFO buffer. This includes the skip frame for a full FIFO. An empty FIFO corresponds to 0x000. The byte counter may be reset by reading out all frames from the FIFO buffer or when the FIFO is reset through the Register (0x7E) CMD. The byte counter is updated, when a complete frame is read or written. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 57 2.11.10 Register (0x24) FIFO_DATA ADDRESS 0x24 RESET see definition MODE see definition DESCRIPTION FIFO data readout register. DEFINITION The FIFO data are organized in frames as described in chapter 2.5.1. The new data flag is preserved. Read burst access must be used, the address will not increment when the read burst reads at the address of FIFO_DATA. When a frame is only partially read out, it is retransmitted including the header at the next readout. Name Bit Read/Write Reset Value Content 7 R n/a fifo_data<7:4> Bit Read/Write Reset Value Content 3 R n/a fifo_data<3:0> Register (0x24) FIFO_DATA 6 5 R R n/a n/a 4 R n/a 2 R n/a 0 R n/a fifo_data<7:0>: FIFO data readout; Register (0x46-0x47) FIFO_CONFIG. 1 R n/a data format depends on the setting of 2.11.11 Register (0x40) ACC_CONF ADDRESS 0x40 RESET 0b00101000 MODE RW DESCRIPTION Sets the output data rate, the bandwidth, and the read mode of the acceleration sensor. DEFINITION Name Bit Read/Write Reset Value Content 7 R/W 0 acc_us Bit Read/Write Reset Value Content 3 R/W 1 acc_odr BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Register (0x40) ACC_CONF 6 5 R/W R/W 0 1 acc_bwp 4 R/W 0 2 R/W 0 0 R/W 0 1 R/W 0 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet acc_us: acc_bwp: acc_odr: Page 58 undersampling parameter. The undersampling parameter is typically used in low power mode bandwidth parameter determines filter configuration (acc_us=0) and averaging for undersampling mode (acc_us=1). For details see chapter 2.2.4. define the output data rate in Hz is given by 100/28-val(acc_odr). The output data rate is independent of the power mode setting for the sensor acc_odr 0b0000 0b0001 0b0010 ... 0b1000 ... 0b1011 0b1100 0b1101-0b1111 Output data rate in Hz Reserved 25/32 25/16 100 800 1600 Reserved When acc_us is set to `0' and the accelerometer is in low-power mode, it will change to normal mode. If the acc_us is set to `0' and an command to enter low-power mode is send to the Register (0x7E) CMD, this command is ignored. Configurations without a bandwidth number are illegal settings and will result in an error code in the Register (0x02) ERR_REG. 2.11.12 Register (0x41) ACC_RANGE ADDRESS 0x41 RESET see definition MODE see defintion DESCRIPTION The register allows the selection of the accelerometer g-range. DEFINITION Name Bit Read/Write Reset Value Content 7 R/W 0 Reserved Bit Read/Write Reset Value Content 3 R/W 0 acc_range<3:0> Register (0x41) ACC_RANGE 6 5 R/W R/W 0 0 4 R/W 0 2 R/W 0 0 R/W 1 0 1 R/W 1 acc_range<3:0>: Selection of accelerometer g-range: 0b0011 2g range; 0b0101 4g range; 0b1000 8g range; BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet reserved: Page 59 0b1100 16g range; all other settings 2g range write `0' Changing the range of the accelerometer does not clear the data ready bit in the Register (0x1B) STATUS. It is recommended to read the Register (0x04-0x17) DATA after the range change to remove a stall data ready bit from before the range change. 2.11.13 Register (0x42) GYR_CONF ADDRESS 0x42 RESET 0b00101000 MODE RW DESCRIPTION Sets the output data rate, the bandwidth, and the read mode of the gyroscope in the sensor. DEFINITION Name Bit Read/Write Reset Value Content 7 R/W 0 reserved Bit Read/Write Reset Value Content 3 R/W 1 gyr_odr Register (0x42) GYR_CONF 6 5 R/W R/W 0 1 gyr_bwp 4 R/W 0 2 R/W 0 0 R/W 0 1 R/W 0 gyr_odr: defines the output data rate of the gyro in the sensor. This is independent of the power mode setting for the sensor. The output data rate in Hz is given by 100/28-val(gyr_odr). gyr_odr 0b0110 ... 0b1000 ... 0b1100 0b1101 0b111x Output data rate in Hz 25 100 1600 3200 Reserved gyr_bwp: the gyroscope bandwidth coefficient defines the 3 dB cutoff frequency of the low pass filter for the sensor data. For details see Section 2.4.2. Configurations without a bandwidth number are illegal settings and will result in an error code in the Register (0x02) ERR_REG. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 60 2.11.14 Register (0x43) GYR_RANGE ADDRESS 0x43 RESET 0b00000000 MODE RW DESCRIPTION Defines the BMI160 angular rate measurement range DEFINITION A measurement range is selected by setting the range bits as follows: Name Bit Read/Write Reset Value Content 7 R/W 0 Reserved Bit Read/Write Reset Value Content 3 R/W 0 reserved range[2:0] `000' `001' `010' `011' `100' `101', 110, 111 Register (0x43) GYR_RANGE 6 5 R/W R/W 0 0 2 R/W 0 gyr_range<2:0> Full Scale 2000/s 1000/s 500/s 250/s 125/s reserved 1 R/W 0 4 R/W 0 0 R/W 0 Resolution 16.4 LSB//s 61.0 m/s / LSB 32.8 LSB//s 30.5 m/s / LSB 65.6 LSB//s 15.3 m/s / LSB 131.2 LSB//s 7.6 m/s / LSB 262.4 LSB//s 3.8m/s / LSB gyr_range<2:0>: Angular Rate Range and Resolution. reserved: write `0' Changing the range of the gyroscope does not clear the data ready bit in the Register (0x1B) STATUS. It is recommended to read the Register (0x04-0x17) DATA after the range change to remove a stall data ready bit from before the range change. 2.11.15 Register (0x44) MAG_CONF ADDRESS 0x44 RESET 0b1000-1000 MODE RW DESCRIPTION Sets the output data rate of the magnetometer interface in the sensor. Name Register (0x44) MAG_CONF Bit 7 6 5 4 Read/Write R/W R/W R/W R/W Reset Value 0 0 0 0 Content Reserved BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Bit Read/Write Reset Value Content 3 R/W 0 mag_odr <3:0> 2 R/W 0 Page 61 1 R/W 0 0 R/W 0 DEFINITION Bits <3:0> define the poll rate for the magnetometer attached to the magnetometer interface. This is independent of the power mode setting for the sensor. The output data rate in Hz is given by 50/27-val(ODR<3:0>). In addition to setting the poll rate, it is required to configure the magnetometer properly using the Register (0x4B-0x4F) MAG_IF. Bit<3:0> mag_odr 0b0000 0b0001 0b0010 ... 0b0110 ... 0b1000 ... 0b1011 0b1100 - 0b1111 Output data rate in Hz reserved 25/32 25/16 25 100 800 reserved Bit <7:4> reserved 2.11.16 Register (0x45) FIFO_DOWNS ADDRESS 0x45 (1 byte) RESET 0b0000-0000 MODE RW DESCRIPTION Used to configure the down sampling ratios of the accel and gyro data for FIFO. DEFINITION The downsampling ratio for the gyro data are given by 2 Val(gyr_fifo_downs), the downsampling ratio for accel data are given by 2 Val(acc_fifo_downs). [acc,gyr]_fifo_filt_data=0 (1) selects pre-filtered (filtered) data for the FIFO for accelerometer and gyroscope, respectively. Name Bit Read/Write Reset Value Content 7 R/W 1 acc_fifo_filt_data Register (0x45) FIFO_DOWNS 6 5 R/W R/W 0 0 acc_fifo_downs Bit Read/Write Reset Value Content 3 R/W 1 gyr_fifo_filt_data 2 R/W 0 gyr_fifo_downs BST-BMI160-DS000-08 | Revision 0.9 | October 2018 1 R/W 0 4 R/W 0 0 R/W 0 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 62 2.11.17 Register (0x46-0x47) FIFO_CONFIG ADDRESS 0x46 (2 bytes) RESET see definition MODE see definition DESCRIPTION The Register (0x46-0x47) FIFO_CONFIG is a read/write register and can be used for reading or setting the current FIFO watermark level. This register can also be used for setting the different modes of operation of the FIFO, e.g. which data is going to be stored in it and which format is going to be used (header or headerless mode). DEFINITION Name Bit 7 Read/Write R/W Reset Value 1 Register (0x46-0x47) FIFO_CONFIG [0] 6 5 4 R/W R/W R/W 0 0 0 Content fifo_water_mark <7:4> Bit Read/Write Reset Value Content 3 2 R/W R/W 0 0 fifo_water_mark <3:0> 1 R/W 0 0 R/W 0 fifo_water_mark <7:0>: fifo_water_mark defines the FIFO watermark level. An interrupt will be generated, when the number of entries in the FIFO exceeds fifo_water_mark. The unit of fifo_water_mark are 4 bytes. Name Bit Read/Write Reset Value Content 7 R/W 0 fifo_gyr_en Register (0x46-0x47) FIFO_CONFIG [1] 6 5 4 R/W R/W R/W 0 0 1 fifo_acc_en fifo_mag_en fifo_header_en Bit Read/Write Reset Value Content 3 R/W 0 fifo_tag_int1_en 2 R/W 0 fifo_tag_int2_en 1 R/W 0 fifo_time_en 0 R/W 0 reserved When all the sensors are disabled, the FIFO is disabled and no headers are written. The sensors can be disabled via fifo_gyr_en, fifo_acc_en and fifo_mag_en, respectively. fifo_gyr_en: `0' no gyro data are stored in FIFO, `1' gyro data are stored in FIFO (all 3 axes) fifo_acc_en: `0' no acc data are stored in FIFO, `1' acc data are stored in FIFO (all 3 axes) fifo_mag_en: `0' no mag data are stored in FIFO, `1' mag data are stored in FIFO (all 3 axes) fifo_header_en: If `1' each frame contains a header as defined in chapter 2.5. If `0' the frame format will be headerless. In this case, the output data rates of all enabled sensors for the FIFO need to be identical. fifo_tag_int1_en: 1' (`0') enables (disables) FIFO tag (interrupt) fifo_tag_int2_en: 1' (`0') enables (disables) FIFO tag (interrupt) fifo_time_en: `1'(`0') returns (does not return) a sensortime frame after the last valid frame when more data are read than valid frames are in the FIFO. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 63 2.11.18 Register (0x4B-0x4F) MAG_IF ADDRESS 0x4B (5 byte) RESET [0]: 0b0010-0000 [1]: 0b1000-0000 [2]: 0b0100-0010 [3]: 0b0100-1100 [4]: 0b0000-0000 MODE RW DESCRIPTION Register for indirect addressing of the magnetometer connected to the magnetometer interface. This register allows read and write operations on the magnetometer register map. In addition it is used to setup the read loop for the magnetometer data. Setup and read loop are exclusive to each other, i.e. during the read loop no registers in the magnetometer may be accessed. DEFINITION Register (0x4B-0x4F) MAG_IF [0] bit definition 7:1 I2C device address 0 reserved Register (0x4B0x4F) MAG_IF [1] bit definition 7 Acronym 6 <5:2> reserved mag_offset <1:0> mag_rd_burst Register MAG_IF[2] MAG_IF[3] MAG_IF[4] mag_manual_en Enable magnetometer register access on MAG_IF[2] (read operations) or MAG_IF[3] (write operations). This implies that the Register (0x040x17) DATA are not updated with magnetometer values. Accessing magnetometer requires the magnetometer in normal mode in Register (0x03) PMU_STATUS. Trigger-readout offset in units 2.5 ms. If set to zero, the offset is maximum, i.e. after readout a trigger is issued immediately. Data length of read burst operation, which reads out data from magnetometer (0b00=1,0b01=2,0b10=6,0b11=8 byte). Setup mode Address to read Address to write Data to write Trigger and Readout mode Address to read Address to write Data to write 2.11.19 Register (0x50-0x52) INT_EN ADDRESS 0x50 (3 byte) RESET BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 64 [0] 0b0000-0000 [1] 0b0000-0000 [2] 0b0000-0000 MODE RW DESCRIPTION Controls which interrupt engines are enabled. DEFINITION Register (0x50-0x52) INT_EN [0] 7 6 5 4 3 2 1 0 Acronym int_flat_en int_orient_en int_s_tap_en int_d_tap_en Definition Flat interrupt Orientation interrupt Single tap interrupt Double tap interrupt Reserved int_anymo_z_en Anymotion z int_anymo_y_en Anymotion y int_anymo_x_en Anymotion x `0' disables the interrupt, `1' enables it. Register (0x50-0x52) INT_EN [1] 7 6 5 4 3 2 1 0 acronym int_fwm_en int_ffull_en int_drdy_en int_low_en int_highz_en int_highy_en int_highx_en definition Reserved FIFO watermark FIFO full Data ready Low g High g z High g y High g x `0' disables the interrupt, `1' enables the interrupt. Register (0x50-0x52) INT_EN [2] acronym 7 6 5 4 3 int_step_det_en 2 int_nomoz_en 1 int_nomoy_en 0 int_nomox_en `0' disables the interrupt, `1' enables the interrupt. definition Reserved Reserved Reserved Reserved Step detector No/slow motion z No/slow motion y No/slow motion x Note: Step_cnt_en and step_cnt_clr enable and clear the step counter (which is not related to interrupts). BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 65 2.11.20 Register (0x53) INT_OUT_CTRL ADDRESS 0x53 RESET 0b0000-0000 MODE RW DESCRIPTION Contains the behavioral configuration (electrical definition of the interrupt pins. DEFINITION Register (0x53) INT_OUT_CTRL 7 Acronym definition int2_output_en 6 int2_od 5 int2_lvl 4 int2_edge_crtl 3 int1_output_en 2 int1_od 1 int1_lvl Output enable for INT2 pin, select `0'output disabled, or `1' output enabled select `0'push-pull, or `1' open drain behavior for INT2 pin. Only valid if int2_output_en=1. `0'active low, or `1'active high level for INT2 pin. If int2_output_en=1 this applies for interrupt outputs, if int2_output_en=0 this applies to trigger PMU configured in Register (0x6C) PMU_TRIGGER. For tagging a frame in FIFO through fifo_tag_int2_en in Register (0x46-0x47) FIFO_CONFIG the setting of int2_lvl is not relevant. `1' (`0') is edge (level) triggered for INT2 pin. This configuration is only meaningful when the pin is enabled as input. Output enable for INT1 pin, select `0'output disabled, or `1' output enabled select `0'push-pull, or `1' open drain behavior for INT1 pin. Only valid if int1_output_en=1 select `0'active low, or`1'active high level for INT1 pin. If int1_output_en=1 this applies for interrupt outputs, if int1_output_en=0 this applies to trigger PMU configured in Register (0x6C) PMU_TRIGGER. For tagging in FIFO through fifo_tag_int2_en in Register (0x46-0x47) FIFO_CONFIG the setting of int2_lvl is not relevant. For tagging a frame in FIFO through fifo_tag_int1_en in Register (0x46-0x47) FIFO_CONFIG the setting of int1_lvl is not relevant. 0 int1_edge_crtl `1' (`0') is edge (level) triggered for INT1 pin. This configuration is only meaningful when the pin is enabled as input. int_edge_crtl is only relevant for int_output_en ='1' 2.11.21 Register (0x54) INT_LATCH ADDRESS 0x54 RESET 0b0000-0000 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 66 MODE RW DESCRIPTION Contains the interrupt reset bit and the interrupt mode selection. DEFINITION Not applied to new data, orientation, and flat interrupt. Register (0x54) INT_LATCH <7:6> 5 MODE n/a RW 4 RW <3:0> RW <3:0> 0b0000 0b0001 0b0010 0b0011 0b0100 0b0101 0b0110 0b0111 0b1000 0b1001 0b1010 0b1011 0b1100 0b1101 0b1110 0b1111 Definition Reserved Input enable for INT2 pin, select `0'input disabled, or `1' input enabled Input enable for INT1 pin, select `0'input disabled, or `1' input enabled Latched/non-latched/temporary interrupt modes Interrupt mode non-latched temporary, 312.5s temporary, 625s temporary, 1.25ms temporary, 2.5 ms temporary, 5ms temporary, 10ms temporary 20ms temporary, 40ms temporary, 80ms temporary, 160ms temporary, 320ms temporary, 640ms temporary, 1.28s temporary, 2.56s latched The times for the temporary modes have been selected to be 50% of the pre-filtered data rate and then power of two increments. 2.11.22 Register (0x55-0x57) INT_MAP ADDRESS 0x55 (3 bytes) RESET [0] 0b0000-0000 [1] 0b0000-0000 [2] 0b0000-0000 MODE RW DESCRIPTION Controls which interrupt signals are mapped to the INT1 and INT2 pin. DEFINITION The tables show bit number of a register and meaning of the interrupt pin. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 67 The times for the temporary modes have been selected to be 50% of the pre-filtered data rate and then power of two increments. Register (0x55-0x57) INT_MAP [0] 7 6 5 4 3 2 1 0 Interrupt mapped to pin INT1 Flat Orientation Single tap Double tap No motion Anymotion / Significant motion High-g Low-g / Step detection Register (0x55-0x57) INT_MAP [1]<7:4> 7 6 5 4 Interrupt mapped to pin INT1 Data ready FIFO watermark FIFO full PMU trigger Register (0x55-0x57) INT_MAP [1]<3:0> 3 2 1 0 Interrupt mapped to pin INT2 Data ready FIFO watermark FIFO full PMU trigger Register (0x55-0x57) INT_MAP [2] 7 6 5 4 3 2 1 0 Interrupt mapped to pin INT2 Flat Orientation Single tap Double tap No motion Anymotion / Significant motion High-g Low-g / Step detection `1' means mapping is active, `0' means mapping is inactive. When the external interrupt is mapped to an interrupt pin, all other interrupt mappings are disabled for this interrupt. When an external interrupt is mapped to an interrupt pin, no other interrupts may be enabled. Application Note: There are two interrupt types defined in BMI160: Data driven interrupts (fifo_watermark, fifo_full, data ready) and physical interrupts (all others). If edge triggered interrupts are used and the user relies on a new edge if after servicing the interrupt the interrupt condition still holds, only one type of interrupt should be mapped to an interrupt pin, if edge triggered interrupts are needed. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 68 2.11.23 Register (0x58-0x59) INT_DATA ADDRESS 0x58 (2 byte) RESET [0] 0b0000-0000 [1] 0b0000-0000 MODE RW DESCRIPTION Contains the data source definition for the two interrupt groups. DEFINITION Name Bit Read/Write Reset Value Content 7 R/W 0 int_lowhigh_src Register (0x58-0x59) INT_DATA [0] 6 5 R/W R/W 0 0 Reserved Bit Read/Write Reset Value Content 3 R/W 0 int_tap_src 2 R/W 0 Reserved Name Bit Read/Write Reset Value Content 7 R/W 0 int_motion_src Register (0x58-0x59) INT_DATA [1] 6 5 R/W R/W 0 0 Reserved 4 R/W 0 Bit Read/Write Reset Value Content 3 R/W 0 Reserved 2 R/W 0 0 R/W 0 int_lowhighg_src: int_tap_src: int_motion_src: 1 R/W 0 1 R/W 0 4 R/W 0 0 R/W 0 `0' (`1') selects filtered (pre-filtered) data for the interrupt engine for the low and high g interrupts. Pre-filtered data are not supported in low-power mode. `0' (`1') selects filtered (pre-filtered) data for the interrupt engine for the single and double tap interrupts. Pre-filtered data are not supported in lowpower mode. `0' (`1') selects filtered (pre-filtered) data for the interrupt engine for the nomotion and anymotion interrupts. Pre-filtered data are not supported in low-power mode. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 69 2.11.24 Register (0x5A-0x5E) INT_LOWHIGH ADDRESS 0x5A (5 bytes) RESET see definition MODE see definition DESCRIPTION Contains the configuration for the low g interrupt DEFINITION Register (0x5A-0x5E) INT_LOWHIGH[0] contains the delay time definition for the low-g interrupt. Name Bit Read/Write Reset Value Content 7 W 0 int_low_dur<7:4> Bit Read/Write Reset Value Content 3 R/W 0 int_low_dur<3:0> Register (0x5A-0x5E) INT_LOWHIGH [0] 6 5 4 R/W R/W R/W 0 0 0 2 R/W 1 1 R/W 1 0 R/W 1 int_low_dur<7:0>: low-g interrupt trigger delay according to [int_low_dur<7:0> + 1] * 2.5 ms in a range from 2.5 ms to 640 ms; the default corresponds to a delay of 20 ms. If Register (0x58-0x59) INT_DATA configures that this interrupt uses pre-filtered data, the sensor must not be in low power mode. Register (0x5A-0x5E) INT_LOWHIGH[1] contains the threshold definition for the low-g interrupt. Name Bit Read/Write Reset Value Content 7 W 0 int_low_th<7:4> Bit Read/Write Reset Value Content 3 R/W 0 int_low_th<3:0> int_low_th<7:0>: Register (0x5A-0x5E) INT_LOWHIGH [1] 6 5 4 R/W R/W R/W 0 1 1 2 R/W 0 1 R/W 0 0 R/W 0 low-g interrupt trigger threshold according to Val(int_low_th<7:0>) * 7.81 mg for Val(int_low_th<7:0>)>0 and 3.91 mg for Val(int_low_th<7:0>)=0. The range of the threshold is from 3.91 mg to 2.000 g; the default value corresponds to an acceleration of 375 mg BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 70 Register (0x5A-0x5E) INT_LOWHIGH[2] contains the low-g interrupt mode selection, the low-g interrupt hysteresis setting, and the high-g interrupt hysteresis setting. Name Bit Read/Write Reset Value Content 7 R/W 1 int_high_hy<1:0> Bit Read/Write Reset Value Content 3 R/W 0 reserved Register (0x5A-0x5E) INT_LOWHIGH [2] 6 5 4 R/W R/W R/W 0 0 0 Reserved 2 R/W 0 1 R/W 0 int_low_hy<1:0> 0 R/W 1 int_high_hy<1:0>: hysteresis of high-g interrupt according to Val(int_high_hy<1:0>) * 125 mg (2g range), Val(int_high_hy<1:0>) * 250 mg (4-g range), Val(int_high_hy<1:0>) * 500 mg (8-g range), or Val(int_high_hy<1:0>) * 1000 mg (16-g range) int_low_hy<1:0>: hysteresis of low-g interrupt according to int_low_hy<1:0> * 125 mg independent of the selected accelerometer g-range Register (0x5A-0x5E) INT_LOWHIGH[3] contains the delay time definition for the high-g interrupt. Name Bit Read/Write Reset Value Content Register (0x5A-0x5E) INT_LOWHIGH [3] 6 5 4 R/W R/W R/W 0 0 0 7 R/W 0 int_high_dur<7:4> Bit Read/Write Reset Value Content 3 2 R/W R/W 1 0 int_high_dur<3:0> 1 R/W 1 0 R/W 1 int_high_dur<7:0>: high-g interrupt trigger delay according to [int_high_dur<7:0> + 1] * 2.5 ms in a range from 2.5 ms to 640 ms; the default corresponds to a delay of 30 ms. If Register (0x58-0x59) INT_DATA configures that this interrupt uses prefiltered data, the sensor is not entering low-power mode. Register (0x5A-0x5E) INT_LOWHIGH[4] contains the threshold definition for the high-g interrupt. Name Bit Read/Write Reset Value Content 7 R/W 1 high_th<7:4> BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Register (0x5A-0x5E) INT_LOWHIGH[4] 6 5 4 R/W R/W R/W 1 0 0 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Bit Read/Write Reset Value Content 3 R/W 0 high_th<3:0> 2 R/W 0 Page 71 1 R/W 0 0 R/W 0 int_high_th<7:0>: threshold of high-g interrupt according to Val(int_high_th<7:0>) * 7.81 mg (2g range), Val(int_high_th<7:0>) * 15.63 mg (4g range), Val(int_high_th<7:0>) * 31.25 mg (8g range), or Val(int_high_th<7:0>) * 62.5 mg (16g range). For Val(int_high_th<7:0>)=0, the thresholds are defined by 3.91 mg (2g range), 7.81 mg (4g range), 15.63 mg (8g range), 31.25 mg (16g range) 2.11.25 Register (0x5F-0x62) INT_MOTION ADDRESS 0x5F (4 byte) RESET [0] 0000-0000 [1] 0001-0100 [2] 0001-0100 [3] 0001-0100 MODE see definition DESCRIPTION Contains the configuration for the anymotion and nomotion interrupts DEFINITION Register (0x5F-0x62) INT_MOTION[0] contains the definition of the number of samples to be evaluated for the anymotion interrupt and the slow/no-motion interrupt trigger delay. Name Bit Read/Write Reset Value Content Register (0x5F-0x62) INT_MOTION [0] 7 6 5 4 R/W R/W R/W R/W 0 0 0 0 int_slo_no_mot_dur<5:2> Bit Read/Write Reset Value Content 3 2 R/W R/W 0 0 int_slo_no_mot_dur<1:0> 1 0 R/W R/W 0 0 int_anym_dur<1:0> int_slo_no_mot_dur<5:0>: Function depends on whether the slow-motion or no-motion interrupt function has been selected. If the slow-motion interrupt function has been enabled (int_no_mot_sel = `0') then [int_slo_no_mot_dur<1:0>+1] consecutive slope data points must be above the slow/no-motion threshold (int_slo_no_mot_th) for the slow-/no-motion interrupt to trigger. If the nomotion interrupt function has been enabled (int_no_mot_sel = `1') then int_slo_no_motion_dur<5:0> defines the time for which no slope data points must exceed the slow/no-motion threshold (int_slo_no_mot_th) for the slow/no-motion interrupt to trigger. The delay time in seconds may be calculated according with the following equation: BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 72 int_slo_no_mot_dur<5:4>='b00' [int_slo_no_mot_dur<3:0> + 1] * 1.28 s -> [1.28 - 20.48] s int_slo_no_mot_dur<5:4>='b01' [int_slo_no_mot_dur<3:0> + 5] 5.12 s-> [25.6 - 102.4] s int_slo_no_mot_dur<5>='1' [int_slo_no_mot_dur<4:0> + 11] * 10.24 s-> [112.64 - 430.08] s int_anym_dur<1:0>: slope interrupt triggers if [int_anym_dur<1:0>+1] consecutive slope data points are above the slope interrupt threshold int_anym_th<7:0> Register (0x5F-0x62) INT_MOTION[1] contains the threshold definition for the any-motion interrupt. Name Bit Read/Write Reset Value Content 7 R/W 0 int_anym_th<7:4> Bit Read/Write Reset Value Content 3 R/W 0 int_anym_th<3:0> Register (0x5F-0x62) INT_MOTION [1] 6 5 4 R/W R/W R/W 0 0 1 2 R/W 1 1 R/W 0 0 R/W 0 Int_anymo_th<7:0>: Threshold of the any-motion interrupt. It is range-dependent and defined as a sample-to-sample difference according to int_anym_th<7:0> * 3.91 mg (2-g range) / int_anym_th<7:0> * 7.81 mg (4-g range) / int_anym_th<7:0> * 15.63 mg (8-g range) / int_anym_th<7:0> * 31.25 mg (16-g range) For int_anym_th<7:0>=0x00 the threshold is 1.95 mg (2g range) / 3.91 mg (4g range) / 7.81 mg (8g range) / 15.63 mg (16g range) Register (0x5F-0x62) INT_MOTION[2] contains the threshold definition for the slow/no-motion interrupt. Name Bit Read/Write Reset Value Content Register (0x5F-0x62) INT_MOTION [2] 7 6 5 4 R/W R/W R/W R/W 0 0 0 1 int_slo_no_mot_th<7:4> Bit Read/Write Reset Value Content 3 2 R/W R/W 0 1 int_slo_no_mot_th<3:0> BST-BMI160-DS000-08 | Revision 0.9 | October 2018 1 R/W 0 0 R/W 0 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 73 int_slo_no_mot_th<7:0>: Threshold of slow/no-motion interrupt. It is range-dependent and defined as a sample-to-sample difference according to int_slo_no_mot_th<7:0> * 3.91 mg (2-g range), int_slo_no_mot_th<7:0> * 7.81 mg (4-g range), int_slo_no_mot_th<7:0> * 15.63 mg (8-g range), int_slo_no_mot_th<7:0> * 31.25 mg (16-g range) For int_slo_no_mot_th<7:0>=0x00 the threshold is 1.95 mg (2g range) / 3.91 mg (4g range) / 7.81 mg (8g range) / 15.63 mg (16g range) Register (0x5F-0x62) INT_MOTION[3] contains slow / no motion configuration Name Bit Read/Write Reset Value Content Register (0x5F-0x62) INT_MOTION [3] 6 5 4 R/W R/W R/W 0 0 1 int_sig_mot_proof<1:0> 7 R/W 0 reserved Bit Read/Write Reset Value Content 3 2 R/W R/W 0 1 int_sig_mot_skip <1:0> 1 R/W 0 int_sig_mot_sel 0 R/W 0 int_no_mot_sel int_no_mot_sel: `1' (`0') selects no-motion (slow-motion) interrupt function int_sig_mot_sel: `1' (`0') selects significant (anymotion) interrupt function int_sig_mot_skip: set the skip time of the significant motion interrupt: 0=1.5s, 1=3s, 2=6s, 3=12s int_sig_mot_proof: set the proof time of the significant motion interrupt: 0=0.25s, 1=0.5s, 2=1s, 3=2s 2.11.26 Register (0x63-0x64) INT_TAP ADDRESS 0x63 (2 byte) RESET see definition MODE see definition DESCRIPTION Contains the configuration for the tap interrupts DEFINITION Register (0x63-0x64) INT_TAP[0] contains the timing definitions for the single tap and double tap interrupts. Name Bit Read/Write Reset Value Content 7 R/W 0 int_tap_quiet Register (0x63-0x64) INT_TAP [0] 6 5 R/W R/W 0 0 int_tap_shock reserved Bit Read/Write Reset Value Content 3 R/W 0 reserved 2 R/W 1 int_tap_dur<2:0> int_tap_quiet: 1 R/W 0 4 R/W 0 reserved 0 R/W 0 selects a tap quiet duration of `0' 30 ms, `1' 20 ms BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 74 int_tap_shock: selects a tap shock duration of `0' 50 ms, `1'75 ms reserved: write `0' int_tap_dur<2:0>: selects the length of the time window for the second shock event for double tap detection according to 0b000 50 ms, 0b001 100 ms, 0b010 150 ms, 0b011 200 ms, 0b100 250 ms, 0b101 375 ms, 0b110 500 ms, 0b111 700 ms. If Register (0x58-0x59) INT_DATA configures that this interrupt uses pre-filtered data, the sensor is not entering low-power mode. Register (0x63-0x64) INT_TAP[1] defines the threshold definition for the single and double tap interrupts. Name Bit Read/Write Reset Value Content 7 R/W 0 reserved Bit Read/Write Reset Value Content 3 R/W 1 int_tap_th<3:0> reserved: int_tap_th<3:0>: Register (0x63-0x64) INT_TAP [1] 6 5 R/W R/W 0 0 2 R/W 0 1 R/W 1 4 R/W 0 int_tap_th<4> 0 R/W 0 write `0' threshold of the single/double-tap interrupt corresponding to an acceleration difference of val(int_tap_th<3:0>) * 62.5mg (2g-range), val(int_tap_th<3:0>) * 125mg (4g-range), val(int_tap_th<3:0>) * 250mg (8g-range), and val(int_tap_th<3:0>) * 500mg (16g-range). Int_tap_th<3:0>=0b0000, val(int_tap_th<3:0>)=0.5 is used in the above formulas, e.g. int_tap_th<3:0>=0b0000 means 31.25mg in 2g-range. 2.11.27 Register (0x65-0x66) INT_ORIENT ADDRESS 0x65 (2 byte) RESET see definition MODE see definition DESCRIPTION Contains the configuration for the orientation interrupt DEFINITION Register (0x65-0x66) INT_ORIENT[0] contains the definition of hysteresis, blocking, and mode for the orientation interrupt Name Bit Read/Write Reset Value Content Register (0x65-0x66) INT_ORIENT [0] 7 6 5 4 R/W R/W R/W R/W 0 0 0 1 int_orient_hyst<3:0> BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Bit Read/Write Reset Value Content 3 2 R/W R/W 1 0 int_orient_blocking<1:0> reserved: int_orient_hyst<3:0>: int_orient_blocking<1:0>: int_orient_mode<1:0>: Page 75 1 0 R/W R/W 0 0 int_orient_mode<1:0> write `0' sets the hysteresis of the orientation interrupt; 1 LSB corresponds to 62.5 mg irrespective of the selected g-range selects the blocking mode that is used for the generation of the orientation interrupt. The following blocking modes are available: 0b00 no blocking, 0b01 theta blocking or acceleration in any axis > 1.5g, 0b10 ,theta blocking or acceleration slope in any axis > 0.2 g or acceleration in any axis > 1.5g 0b11 theta blocking or acceleration slope in any axis > 0.4 g or acceleration in any axis > 1.5g and value of orient is not stable for at least 100ms sets the thresholds for switching between the different orientations. The settings: 0b00 symmetrical, 0b01 high-asymmetrical, 0b10 low-asymmetrical, 0b11 symmetrical. Register (0x65-0x66) INT_ORIENT[1] contains the definition of the axis orientation, up/down masking, and the theta blocking angle for the orientation interrupt. Name Bit Read/Write Reset Value Content Register (0x65-0x66) INT_ORIENT [1] 6 5 4 R/W R/W R/W 1 0 0 int_orient_ud_en int_orient_theta<5:4> 7 R/W n/a int_axes_ex Bit Read/Write Reset Value Content 3 2 R/W R/W 1 0 int_orient_theta<3:0> 1 R/W 0 0 R/W 0 int_axes_ex: axes remapping of x-, y- and z-axis value=0: xreg=xsensor, yreg=ysensor, zreg=zsensor value=1: xregysensor, yregzsensor, zregxsensor int_orient_ud_en: change of up/down-bit 1 generates an orientation interrupt, 0 is ignored and will not generate an orientation interrupt int_orient_theta<5:0>:defines a blocking angle between 0 and 44.8 2.11.28 Register (0x67-0x68) INT_FLAT ADDRESS 0x67 (2 byte) RESET see definition BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 76 MODE see definition DESCRIPTION Contains the configuration for the flat interrupt DEFINITION Register (0x67-0x68) INT_FLAT[0] contains the definition of the flat threshold angle for the flat interrupt. Name Bit Read/Write Reset Value Content 7 R/W n/a reserved Bit Read/Write Reset Value Content 3 2 R/W R/W 1 0 int_flat_theta<3:0> reserved: int_flat_theta<5:0>: Register (0x67-0x68) INT_FLAT[0] 6 5 4 R/W R/W R/W n/a 0 0 int_flat_theta<5:4> 1 R/W 0 0 R/W 0 write `0' defines threshold for detection of flat position in range from 0 to 44.8. Register (0x67-0x68) INT_FLAT[1] contains the definition of the flat interrupt hold time and flat interrupt hysteresis. Name Bit Read/Write Reset Value Content 7 R/W 0 reserved Register (0x67-0x68) INT_FLAT [1] 6 5 4 R/W R/W R/W 0 0 1 int_flat_hold_time<1:0> Bit Read/Write Reset Value Content 3 R/W 0 reserved 2 R/W 0 int_flat_hy<2:0> 1 R/W 0 0 R/W 1 reserved: write `0' int_flat_hold_time<1:0>: delay time for which the flat value must remain stable for the flat interrupt to be generated: 0b00 0 ms, 0b01 640 ms, 0b10 1280 ms, 0b11 2560 ms int_flat_hy<2:0>: defines flat interrupt hysteresis. 2.11.29 Register (0x69) FOC_CONF ADDRESS 0x69 RESET 0b00000000 MODE RW DESCRIPTION Contains configuration settings for the fast offset compensation for the accelerometer and the gyroscope DEFINITION Name Register (0x69) FOC_CONF Bit 7 6 5 4 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Read/Write Reset Value Content Bit Read/Write Reset Value Content Page 77 R/W R/W 0 0 Reserved foc_gyr_en 3 2 R/W R/W 0 0 foc_acc_y<1:0> reserved: foc_gyr_en: foc_acc_x: R/W 0 R/W 0 foc_acc_x<1:0> 1 R/W 0 0 R/W 0 foc_acc_z<1:0> write `0' enables fast offset compensation for all three axis of the gyro. offset compensation target value for x-axis is 0b00 disabled, 0b01 +1 g, 0b10 -1 g, or 0b11 0 g. offset compensation target value for y-axis is 0b00 disabled, 0b01 +1 g, 0b10 -1 g, or 0b11 0 g. offset compensation target value for z-axis is 0b00 disabled, 0b01 +1 g, 0b10 -1 g, or 0b11 0 g. foc_acc_y: foc_acc_z: 2.11.30 Register (0x6A) CONF ADDRESS 0x6A RESET 0b00000000 MODE RW DESCRIPTION Configuration of the sensor DEFINITION Register (0x6A) CONF Bit 7 6 5 4 3 2 1 0 nvm_prog_en: Acronym reserved reserved reserved reserved reserved reserved nvm_prog_en reserved Definition Enable NVM programming `1'(`0') enables (disables) that the NVM may be programmed 2.11.31 Register (0x6B) IF_CONF ADDRESS 0x6B RESET see definition MODE RW DESCRIPTION Contains settings for the digital interface. DEFINITION Name Bit 7 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Register (0x6B) IF_CONF 6 5 4 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Read/Write Reset Value Content Bit Read/Write Reset Value Content reserved: spi3: if_mode: R/W 0 reserved 3 R/W 0 reserved R/W 0 2 R/W 0 Page 78 R/W 0 if_mode<1:0> 1 R/W 0 R/W 0 0 R/W 0 spi3 write `0' select 0 4-wire SPI, or 1 3-wire SPI mode for primary 00: primary interface: autoconfig / secondary interface: off 01: Primary interface:I2C / secondary interface:OIS 02: Primary interface: autoconfig / secondary interface: Magnetometer 11: reserved 2.11.32 Register (0x6C) PMU_TRIGGER ADDRESS 0x6C RESET 0b0000-0000 MODE RW DESCRIPTION Used to set the trigger conditions to change the gyro power modes DEFINITION The pmu_gyr_mode in Register (0x03) PMU_STATUS is updated with each transition triggered. Name Bit Read/Write Reset Value Content Bit Read/Write Reset Value Content 7 RW 0 Reserved 3 RW 0 gyr_wakeup_trigg er<0> Register (0x6C) PMU_TRIGGER 6 5 RW RW 0 0 wakeup_int gyr_sleep_state 2 RW 0 1 RW 0 4 RW 0 gyr_wakeup_trigg er<1> 0 RW 0 gyr_sleep_trigger <2:0> gyr_wakeup_trigger: when both trigger conditions are enabled, both conditions must be active to trigger the transition. gyr_wakeup_trigger 0b00 0b01 0b10 0b11 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 anymotion no no yes yes INT1 pin no yes no yes Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 79 gyr_sleep_trigger: when more than one trigger condition is enabled, one is sufficient to trigger the transition. gyr_sleep_trigger 0b000 0b001 0b010 0b011 0b100 0b101 0b110 0b111 nomotion no no no no yes yes yes Yes Not INT1 pin no no yes Yes no no yes yes INT2 pin no yes no yes no yes no yes If gyr_sleep_trigger and gyr_wakeup_trigger are active at the same time, the gyr_wakeup_trigger wins. The INTx pin takes into account the edge/level triggered setting in the Register (0x53) INT_OUT_CTRL. gyr_sleep_state: `1'(`0') transitions to suspend (fast start-up) state wakeup_int: `1'(`0') triggers an interrupt, when a gyro wakeup is triggered 2.11.33 Register (0x6D) SELF_TEST ADDRESS 0x6D RESET 0b0000-0000 MODE RW DESCRIPTION Contains the settings for the sensor self-test configuration and trigger. DEFINITION Name Bit Read/Write Reset Value Content 7 R/W 0 reserved Bit Read/Write Reset Value Content 3 R/W 0 acc_self_test_amp Register (0x6D) SELF_TEST 6 5 R/W R/W 0 0 2 R/W 0 acc_self_test_sign 4 R/W 0 gyr_self_test_ enable 1 0 R/W R/W 0 0 acc_self_test-enable<1:0> reserved: write `0x0' gyr_self_test_enable: starts self-test of the gyroscope. The result can be obtained from Register (0x1B) STATUS. acc_self_test_amp; select amplitude of the selftest deflection 1 high, BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 80 default value is low (0), acc_self_test_sign: select sign of self-test excitation as 1 positive, or 0 negative acc_self_test_enable: starts self-test of the accel: 0b00 self-test disabled, 0b01 self-test enabled. After the self-test has been enabled a delay of a least 50 ms is necessary for the read-out value to settle The result can be obtained from Register (0x1B) STATUS. In addition, for the accel self test the Register (0x40) ACC_CONF has to be set to value 0x2C (acc_odr=1600Hz; acc_bwp=2; acc_us=0), otherwise the accelerometer selftest will not function correctly. It is enabled for all 3 axis at the same time. 2.11.34 Register (0x70) NV_CONF ADDRESS 0x70 RESET see definition MODE RW DESCRIPTION Contains settings for the digital interface. DEFINITION This register is backed by NVM and loaded from NVM during bootup. Name Bit Read/Write Reset Value Content 7 R/W 0 reserved Bit Read/Write Reset Value Content 3 R/W 0 reserved reserved: i2c_wdt_en: i2c_wdt_sel: spi_en: Register (0x70) NV_CONF 6 5 R/W R/W 0 0 4 R/W 0 2 R/W 0 i2c_wdt_en 0 R/W 0 spi_en 1 R/W 0 i2c_wdt_sel write `0' if IC interface mode is selected then `1 enable, or `0' disables the watchdog at the SDI pin (= SDA for IC) select an IC watchdog timer period of `0' 1 ms, or `1' 50 ms disable the I2C and only enable SPI for the primary interface, when it is in autoconfig if_mode. 2.11.35 Register (0x71-0x77) OFFSET ADDRESS 0x71 (7 byte) RESET Reads from NVM MODE RW DESCRIPTION Contains the offset compensation values for accelerometer and gyroscope DEFINITION Offset values, which are added to the internal filtered and pre-filtered data for gyroscope and accelerometer if the function is enabled with gyr_off_en and acc_off_en in the register; the offset values are represented with two's complement notation; the content of the register may be written to the NVM; it is automatically restored from the NVM after each power-on or soft reset; offset BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 81 values may be written directly by the user; it is generated automatically after triggering the fast offset compensation procedure. [0] [1] [2] [3] [4] [5] Name Bit Read/Write Reset Value Content 7 R/W 0 gyr_off_en Bit Read/Write Reset Value Content 3 R/W 0 off_gyr_y<9:8> acc_off_x<7:0> acc_off_y<7:0> acc_off_z<7:0> off_gyr_x<7:0> off_gyr_y<7:0> off_gyr_z<7:0> Register (0x71-0x77) OFFSET [6] 6 5 R/W R/W 0 0 acc_off_en off_gyr_z<9:8> 4 R/W 0 2 R/W 0 0 R/W 0 1 R/W 0 off_gyr_x<9:8> The offset of the accelerometer off_acc_[xyz] is a 8 bit two-complement number in units of 3.9 mg independent of the range selected for the accelerometer. The offset of the gyroscope off_gyr_[xyz] is a 10 bit two-complement number in units of 0.061 /s. Therefore a maximum range that can be compensated is -31.25 /s to +31.25 /s. The configuration is done in the Register (0x70) NV_CONF. The MSBs for the gyro offset setting are also contained in OFFSET[6]. Aside from this, the register also contains the two bits gyr_off_en and acc_off_en, which can be set to 1 in order to enable gyro and accel offset compensation, respectively. 2.11.36 Register (0x78-0x79) STEP_CNT ADDRESS 0x78 (2 byte) RESET [0] 0b0000-0000 [1] 0b0000-0000 MODE R DESCRIPTION Contains the number of steps. DEFINITION Name Bit Read/Write Reset Value Content 7 R 0 step_cnt<15:12> Bit 3 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Register (0x78-0x79) STEP_CNT [1] 6 5 R R 0 0 4 R 0 2 0 1 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Read/Write Reset Value Content Name Bit Read/Write Reset Value Content R 0 step_cnt<11:8> 7 R 0 step_cnt<7:4> R 0 Page 82 R 0 Register (0x78-0x79) STEP_CNT [0] 6 5 R R 0 0 Bit 3 2 1 Read/Write R R R Reset Value 0 0 0 Content step_cnt<3:0> step_cnt: number of steps counted since last POR or step counter reset R 0 4 R 0 0 R 0 2.11.37 Register (0x7A-0x7B) STEP_CONF ADDRESS 0x7A (2 byte) RESET na MODE R DESCRIPTION Contains configuration of the step detector DEFINITION Name Bit Read/Write Reset Value Content 7 W 0 step_conf<7:4> Bit Read/Write Reset Value Content 3 R/W 0 step_conf<3:0> Register (0x7A-0x7B) STEP_CONF [0] 6 5 4 R/W R/W R/W 0 0 0 2 R/W 0 1 R/W 0 0 R/W 0 Name Bit Read/Write Reset Value Content 7 W 0 Register (0x7A-0x7B) STEP_CONF [1] 6 5 4 R/W R/W R/W 0 0 0 reserved Bit Read/Write Reset Value Content 3 R/W 0 step_cnt_en 2 1 R/W R/W 0 0 step_conf<10:8> BST-BMI160-DS000-08 | Revision 0.9 | October 2018 0 R/W 0 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 83 There are three settings to balance between sensitivity (false negatives) and robustness (false positives): Normal mode: Recommended for most applications. Well balanced between false positives and false negatives. STEP_CONF[0]: 0x15 (0b0001 0101) STEP_CONF[1]: 0x03 (0b0000 0011) (the step_cnt_en bit is set to 0) Sensitive mode: Recommended for light weighted persons. Will give few false negatives but eventually more false positives. STEP_CONF[0]: 0x2D (0b0010 1101) STEP_CONF[1]: 0x00 (0b0000 0000) (the step_cnt_en bit is set to 0) Robust mode: Will give few false positives but eventually more false negatives. STEP_CONF[0]: 0x1D (0b0001 1101) STEP_CONF[1]: 0x07 (0b0000 0111) (the step_cnt_en bit is set to 0) The step counter register can be read out at Register (0x78-0x79) STEP_CNT. The step counter can be reset by sending the command 0xB2 to the Register (0x7E) CMD. 2.11.38 Register (0x7E) CMD Register (0x7E) CMD ADDRESS 0x7E RESET na MODE R DESCRIPTION Command register triggers operations like softreset, NVM programming, etc. DEFINITION Name Bit Read/Write Reset Value Content 7 W 0 cmd<7:4> Bit Read/Write Reset Value Content 3 W 0 cmd<3:0> Register (0x7E) CMD 6 5 W W 0 0 4 W 0 2 W 0 0 W 0 1 W 0 During the time a command is executed, it occupies the Register (0x7E) CMD. All new writes to this register are dropped during this time with the exception of the softreset command. If a write to the Register (0x7E) CMD is dropped, drop_cmd_err in Register (0x02) ERR_REG is set. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 84 Table 24: Typical and max. execution times for which the CMD register is occupied Command code Typ. time3 in ms Max. time4 in ms Set PMU mode of accelerometer to normal or low power 0x11-0x12 3.2 3.8 Set PMU mode of gyroscope to normal or fast start-up from suspend mode 0x15; 0x17 55 80 Set PMU mode of magnetometer interface to suspend, normal, or low-power 0x18-0x1B 0.35 0.5 Description The time it takes to perform a soft reset in conjunction with re-starting a sensor is essentially given by the corresponding PMU command execution time in Table 24 (to be more exact, a system start-up time of 300 s has to be added to the times given for PMU switching). cmd: start_foc: 0x03 Starts Fast Offset Calibration for the accel and gyro as configured in Register (0x69) FOC_CONF and stores the result into the Register (0x71-0x77) OFFSET register. acc_set_pmu_mode: 0b0001 00nn Sets the PMU mode for the accelerometer. The encoding for `nn' is identical to acc_pmu_status in Register (0x03) PMU_STATUS. gyr_set_pmu_mode: 0b0001 01nn Sets the PMU mode for the gyroscope. The encoding for `nn' is identical to gyr_pmu_status in Register (0x03) PMU_STATUS mag_set_pmu_mode: 0b0001 10nn Sets the PMU mode for the mag interface. The encoding for `nn' is identical to mag_pmu_status in Register (0x03) PMU_STATUS. prog_nvm: 0xA0 Writes the NVM backed registers into NVM. fifo_flush: 0xB0 clears all data in the FIFO, does not change the Register (0x46-0x47) FIFO_CONFIG and Register (0x45) FIFO_DOWNS registers. 3 When accelerometer, gyroscope, and magnetometer interface are all in suspend or low power mode, another 0.3 ms need to be added. 4 When accelerometer, gyroscope, and magnetometer interface are all in suspend or low power mode, another 0.3 ms need to be added. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 85 int_reset: 0xB1 resets the interrupt engine, the Register (0x1C-0x1F) INT_STATUS and the interrupt pin. softreset: 0xB6 triggers a reset including a reboot. Other values are ignored. Following a delay, all user configuration settings are overwritten with their default state or the setting stored in the NVM, wherever applicable. This register is functional in all operation modes. step_cnt_clr: 0xB2 triggers a reset of the step counter. This register is functional in all operation modes. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 86 3. Digital interfaces 3.1 Interfaces Beside the standard primary interface (I2C and SPI configurable), where sensor acts as a slave to the application processor, BMI160 supports a secondary interface. The secondary interface can be configured either as MAG-Interface (I2C) or as a OIS-Interface (SPI). See picture below. If the secondary interface is configured as MAG-Interface, the BMI160 can be connected to an external sensor (e.g. a magnetometer) in order to build a 9-DoF solution. Then the BMI160 will act as a master to the external sensor, reading the sensor data automatically and providing it to the application processor via the primary interface. Alternatively, the secondary interface can be used as an OIS-Interface to be connected to an external OIS-Control unit, where the OIS controller will act as a master and the BMI160 as a slave. 9 DoF IMU + OIS AP AP I2C / SPI primary interface BMI160 MAG Interface I2C BMM150 I2C BMI160 secondary interface SPI Camera module Figure 21: Examples for secondary interface usage 3.2 Primary Interface By default, the BMI160 operates in I2C mode. The BMI160 interface can also be configured to operate in a SPI 4-wire configuration. It can be re-configured by software to work in 3-wire mode instead of 4-wire mode. All 3 possible digital interfaces share partly the same pins (see Chapter 4). The mapping for the primary interface of the BMI160 is given in the following table: BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 87 Table 25: Mapping of the primary interface pins Pin# Name I/O Type Description 1 SDO Digital I/O Serial data output in SPI Address select in I2C mode 4 INT1 9 INT2 12 CSB Digital in 13 SCx Digital in 14 SDx Digital I/O Digital I/O Digital I/O Connect to (Primary IF) in in SPI3 in I2C SPI4W W SA0 DNC (GND for MISO (float) default addr.) Interrupt pin 1 *) INT1 INT1 INT1 Interrupt pin 2 *) INT2 INT2 INT2 CSB CSB VDDIO SCK SCK SCL MOSI SISO SDA Chip select for SPI mode / Protocol selection pin SCK for SPI serial clock SCL for IC serial clock SDA serial data I/O in I2C SDI serial data input in SPI 4W SDA serial data I/O in SPI 3W The following table shows the electrical specifications of the interface pins: Table 26: Electrical specification of the interface pins Parameter Symbol Condition Min Typ Max Units Pull-up Resistance, CSB pin Rup Internal Pull-up Resistance to VDDIO 75 100 150 k Input Capacitance Cin 5 pF IC Bus Load Capacitance (max. drive capability) CI2C_Load 400 pF 3.2.1 Primary Interface I2C/SPI Protocol Selection The protocol is automatically selected based on the chip select CSB pin behavior after power-up. At reset / power-up, BMI160 is in I2C mode. If CSB is connected to VDDIO during power-up and not changed the sensor interface works in I2C mode. For using I2C, it is recommended to hardwire the CSB line to VDDIO. Since power-on-reset is only executed when, both VDD and VDDIO are established, there is no risk of incorrect protocol detection due to power-up sequence. If CSB sees a rising edge after power-up, the BMI160 interface switches to SPI until a reset or the next power-up occurs. Therefore, a CSB rising edge is needed before starting the SPI BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 88 communication. Hence, it is recommended to perform a SPI single read access to the ADDRESS 0x7F before the actual communication in order to use the SPI interface. If toggling of the CSB bit is not possible without data communication, there is in addition the spi_en bit in Register (0x70) NV_CONF, which can be used to permanently set the primary interface to SPI without the need to toggle the CSB pin at every power-up or reset. 3.2.2 Primary SPI Interface The timing specification for SPI of the BMI160 is given in the following table: Table 27: SPI timing, valid at VDDIO 1.71V Parameter Symbol Condition Clock Frequency fSPI Max. Load on SDI or SDO = 25pF, VDDIO 1.71 V VDDIO < 1.71V SCK Low Pulse SCK High Pulse SDI Setup Time SDI Hold Time SDO Output Delay CSB Setup Time CSB Hold Time Idle time between write accesses, suspend mode, lowpower mode 1 tSCKL tSCKH tSDI_setup tSDI_hold tSDO_OD tCSB_setup tCSB_hold tIDLE_wacc_sum BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Min Max Units 10 MHz 7.5 MHz 30 ns ns ns ns ns 48 48 20 20 Load = 30pF, VDDIO 1.62V 20 40 450 ns ns s Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 89 The following figure shows the definition of the SPI timings: tCSB_setup tCSB_hold CSB SCK tSCKL tSCKH SDI SDO tSDI_setup tSDI_hold tSDO_OD Figure 22: SPI timing diagram The SPI interface of the BMI160 is compatible with two modes, 00 [CPOL = 0 and CPHA = 0] and 11 [CPOL = 1 and CPHA = 1]. The automatic selection between 00 and 11 is controlled based on the value of SCK after a falling edge of CSB. Two configurations of the SPI interface are supported by the BMI160: 4-wire and 3-wire. The same protocol is used by both configurations. The device operates in 4-wire configuration by default. It can be switched to 3-wire configuration by writing 1 to Register (0x6B) IF_CONF spi3. Pin SDI is used as the common data pin in 3-wire configuration. For single byte read as well as write operations, 16-bit protocols are used. The BMI160 also supports multiple-byte read and write operations. In SPI 4-wire configuration CSB (chip select low active), SCK (serial clock), SDI (serial data input), and SDO (serial data output) pins are used. The communication starts when the CSB is pulled low by the SPI master and stops when CSB is pulled high. SCK is also controlled by SPI master. SDI and SDO are driven at the falling edge of SCK and should be captured at the rising edge of SCK. The basic write operation waveform for 4-wire configuration is depicted in the following figure. During the entire write cycle SDO remains in high-impedance state. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 90 CSB SCK SDI R/W AD6 AD5 AD4 AD3 AD2 AD1 SDO AD0 DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0 Z tri-state Figure 23: 4-wire basic SPI write sequence (mode 11) The basic read operation waveform for 4-wire configuration is depicted in the figure below: CSB SCK SDI R/W AD6 AD5 AD4 AD3 AD2 AD1 AD0 SDO DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0 tri-state Figure 24: 4-wire basic SPI read sequence (mode 11) The data bits are used as follows: Bit0: Read/Write bit. When 0, the data SDI is written into the chip. When 1, the data SDO from the chip is read. Bit1-7: Address AD(6:0). BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 91 Bit8-15: when in write mode, these are the data SDI, which will be written into the address. When in read mode, these are the data SDO, which are read from the address. Multiple read operations are possible by keeping CSB low and continuing the data transfer. Only the first register address has to be written. Addresses are automatically incremented after each read access as long as CSB stays active low. The principle of multiple read is shown in figure below: Control byte Start RW CSB = 0 1 Register adress (02h) 0 0 0 0 0 1 0 X X Data byte Data byte Data byte Data register - adress 02h Data register - adress 03h Data register - adress 04h X X X X X X X X X X X X X X X X X X X X Stop X Figure 25: SPI multiple read In SPI 3-wire configuration CSB (chip select low active), SCK (serial clock), and SDI (serial data input and output) pins are used. While SCK is high, the communication starts when the CSB is pulled low by the SPI master and stops when CSB is pulled high. SCK is also controlled by SPI master. SDI is driven (when used as input of the device) at the falling edge of SCK and should be captured (when used as the output of the device) at the rising edge of SCK. The protocol as such is the same in 3-wire configuration as it is in 4-wire configuration. The basic operation wave-form (read or write access) for 3-wire configuration is depicted in the figure below: CSB SCK SDI RW AD6 AD5 AD4 AD3 AD2 AD1 AD0 DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0 Figure 26: 3-wire basic SPI read or write sequence (mode 11) 3.2.3 Primary I2C Interface The IC bus uses SCL (= SCx pin, serial clock) and SDA (= SDx pin, serial data input and output) signal lines. Both lines are connected to VDDIO externally via pull-up resistors so that they are pulled high when the bus is free. The IC addresses are identical to BMG160. The default IC address of the device is 0b1101000 (0x68). It is used if the SDO pin is pulled to GND. The alternative address 0b1101001 (0x69) is selected by pulling the SDO pin to VDDIO. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. X CSB = 1 BMI160 Data sheet Page 92 The IC interface of the BMI160 is compatible with the IC Specification UM10204 Rev. 03 (19 June 2007), available at http://www.nxp.com. The BMI160 supports IC standard mode and fast mode, only 7-bit address mode is supported. For VDDIO = 1.2V to 1.62 V the guaranteed voltage output levels are slightly relaxed as described in Table 1 of the electrical specification section. BMI160 also supports an extended IC mode that allows using clock frequencies up to 1 MHz. In this mode all timings of the fast mode apply and it additionally supports clock frequencies up to 1MHz. The timing specification for IC of the BMI160 is given in the following table: Table 28: Primary IC timings Parameter Symbol Clock Frequency SCL Low Period SCL High Period SDA Setup Time SDA Hold Time Setup Time for a repeated Start Condition Hold Time for a Start Condition Setup Time for a Stop Condition Time before a new Transmission can start Idle time between write accesses, normal mode, standby mode, low-power mode Idle time between write accesses, suspend mode, lowpower mode fSCL tLOW tHIGH Min tSUDAT tHDDAT 1.3 0.6 0.1 0.0 tSUSTA 0.6 tHDSTA 0.6 tSUSTO 0.6 tBUF tIDLE_wacc_n m tIDLE_wacc_s BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Condition um low power mode normal mode low power mode normal mode 400 Max Units 1000 kHz s 1.3 400 1.3 400 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 93 The figure below shows the definition of the IC timings given in Table 28: SDA tBUF tf tLOW SCL tHIGH tr tHDSTA tHDDAT tSUDAT SDA tSUSTA tSUSTO Figure 27: IC timing diagram The IC protocol works as follows: START: Data transmission on the bus begins with a high to low transition on the SDA line while SCL is held high (start condition (S) indicated by IC bus master). Once the START signal is transferred by the master, the bus is considered busy. STOP: Each data transfer should be terminated by a Stop signal (P) generated by master. The STOP condition is a low to HIGH transition on SDA line while SCL is held high. ACKS: Each byte of data transferred must be acknowledged. It is indicated by an acknowledge bit sent by the receiver. The transmitter must release the SDA line (no pull down) during the acknowledge pulse while the receiver must then pull the SDA line low so that it remains stable low during the high period of the acknowledge clock cycle. In the following diagrams these abbreviations are used: S P ACKS ACKM NACKM RW Start Stop Acknowledge by slave Acknowledge by master Not acknowledge by master Read / Write A START immediately followed by a STOP (without SCL toggling from VDDIO to GND) is not supported. If such a combination occurs, the STOP is not recognized by the device. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 94 IC write access: IC write access can be used to write a data byte in one sequence. The sequence begins with start condition generated by the master, followed by 7 bits slave address and a write bit (RW = 0). The slave sends an acknowledge bit (ACKS = 0) and releases the bus. Then the master sends the one byte register address. The slave again acknowledges the transmission and waits for the 8 bits of data which shall be written to the specified register address. After the slave acknowledges the data byte, the master generates a stop signal and terminates the writing protocol. Example of an IC write access: Control byte Slave Adress Start S 1 1 0 1 0 Register adress (0x10) RW ACKS 0 0 0 Data byte 0 1 1 1 0 0 Data (0x09) ACKS 0 0 1 1 0 1 0 ACKS Stop 1 0 1 P Figure 28: IC write IC read access: IC read access also can be used to read one or multiple data bytes in one sequence. A read sequence consists of a one-byte IC write phase followed by the IC read phase. The two parts of the transmission must be separated by a repeated start condition (S). The IC write phase addresses the slave and sends the register address to be read. After slave acknowledges the transmission, the master generates again a start condition and sends the slave address together with a read bit (RW = 1). Then the master releases the bus and waits for the data bytes to be read out from slave. After each data byte the master has to generate an acknowledge bit (ACKS = 0) to enable further data transfer. A NACKM (ACKS = 1) from the master stops the data being transferred from the slave. The slave releases the bus so that the master can generate a STOP condition and terminate the transmission. The register address is automatically incremented and, therefore, more than one byte can be sequentially read out. Once a new data read transmission starts, the start address will be set to the register address specified since the latest IC write command. By default the start address is set at 0x00. In this way repetitive multi-bytes reads from the same starting address are possible. In order to prevent the IC slave of the device to lock-up the IC bus, a watchdog timer (WDT) is implemented. The WDT observes internal IC signals and resets the IC interface if the bus is locked-up by the BMI160. The activity and the timer period of the WDT can be configured through the bits i2c_wdt_en and i2c_wdt_sel at Register (0x70) NV_CONF. Writing 1 (0) to Register (0x70) NV_CONF i2c_wdt_en activates (de-activates) the WDT. Writing 0 (1) to Register (0x70) NV_CONF i2c_wdt_en selects a timer period of 1 ms (50 ms). BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 95 Example of an IC read access (reading gyro data): Slave Adress Start S 1 1 0 1 0 RW ACKS 0 0 0 dummy Control byte X Register adress (0x02) 0 0 0 1 1 0 ACKS 0 Data byte Slave Adress Start Sr 1 1 0 1 0 Read Data (0x02) RW ACKS 0 0 1 Data byte X X X X X X Read Data (0x03) ACKM X X X X X Data byte X X X X X X X X X X X X X ... X X X X X X X ACKM X ... X Data byte Read Data (0x06) X X Read Data (0x05) ACKM Data byte ... X Data byte Read Data (0x04) ... X ACKM X Read Data (0x07) ACKM X X X X X X X X NACK X X Stop P Figure 29: IC multiple read 3.2.4 SPI and IC Access Restrictions In order to allow for the correct internal synchronization of data written to the BMI160, certain access restrictions apply for consecutive write accesses or a write/read sequence through the SPI as well as I2C interface. The required waiting period depends on whether the device is operating in normal mode or other modes. As illustrated in the figure below, an interface idle time of at least 2 s is required following a write operation when the device operates in normal mode. In suspend mode an interface idle time of least 450 s is required5. X-after-Write Write-Operation X-Operation Register Update Period (> 2us / 450us) Figure 30: Post-Write Access Timing Constraints 5 The times are preliminary and need to be verified. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 96 3.3 Secondary Interface The secondary interface can be used in two different classes of use cases: Magnetometer Interface (I2C) for connecting to a MAG-sensor In this case the secondary interface is used as a two-wire interface where an external sensor (MAG-sensor) would be connected as a slave to BMI160. The typical application is connecting a Bosch Sensortec geomagnetic sensor (BMM150). OIS Interface (SPI) for connecting to a OIS control unit In this case the secondary interface is used as a SPI interface where an external control unit is connected as a master to BMI160. External control unit can be e.g. OIS controllers. The mapping for the secondary interface of the BMI160 is given in the following table: Table 29: Mapping of the secondary interface pins Pin# Name I/O Type Description 2 3 10 11 ASDx ASCx OCSB OSDO Digital I/O Digital out Digital I/O Digital I/O Secondary Magnetometer interface Secondary Magnetometer interface Secondary OIS interface Secondary OIS interface Connect to (secondary IF) in SPI4W MOSI SCK CSB MISO in SPI3W SISO SCK CSB DNC in I2C SDA SCL DNC DNC 3.3.1 Magnetometer connected to secondary interface The BMI160 allows attaching an external sensor (MAG-sensor) to a BMI160 via the secondary interface (magnetometer interface), as shown in Figure 21. The connection diagrams for the magnetometer interface are depicted in the chapter 4. The timings of the secondary I2C interface are the same as for the primary I2C interface, see chapter 3.2.3. BMI160 acts as a master of the secondary interface, controls the data acquisition of the MAGsensor (slave of the secondary interface) and presents the data to the application processor (AP) in the user registers of the BMI160 through the primary interface. External pull-up resistors need to be connected and no additional I2C master or slave devices must be attached to the magnetometer interfaces. The BMI160 autonomously reads out the sensor data from BMM150 without intervention of the AP and stores the data in its data registers (per default) and FIFO (see Register (0x46-0x47) FIFO_CONFIG). The initial setup of the BMM150 after power-on is done through indirect addressing in the BMI160. From a system perspective the initialization for BMM150 when attached to BMI160 should be possible within 100ms. The main benefits of the magnetometer interface are: 1. to synchronize sensor data from the magnetometer and the IMU; this improves the quality of sensor data fusion 2. to use the IMU-FIFO for storing the magnetometer data; this can be important for monitoring applications. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 97 3.3.1.1 Configuration options of the secondary interface as magnetometer interface The secondary interface configured as a magnetometer interface is a I2C master interface supporting Fast-Mode IC communication. In this mode the ASCx pad is output only, since both master and slave don't support clock stretching and only master can drive the clock. ASCx is configured as push-pull output when magnetometer interface is enabled. The ASDx pad is used for data transfer between master and slave devices and is bidirectional. There are two basis configurations of the magnetometer interface that can be configured using the Register (0x4B-0x4F) MAG_IF: Setup mode and Data mode. 1. Setup mode (also manual mode): In this mode, the application processor can access every register of the sensor attached to the secondary interface through indirect addressing. This mode is usually used to configure the MAG-sensor and the way the secondary interface reads the data. The Setup mode has to be executed after each POR (power on reset) previous to the first data acquisition in Data mode (see below). The Setup mode is enabled by setting the MAG_IF[1]<7> = 1. The magnetometer may be accessed through the primary interface using indirect addressing. The data for the I2C write to magnetometer is stored in MAG_IF[4]. MAG_IF[2] defines the first address of the register to read (MAG_IF[3] define the address for write access) in the magnetometer register map and triggers the operation itself, when the magnetometer interface is in normal mode. For reads, the number of data bytes defined in mag_rd_burst in register MAG_IF[1]<0:1> are read from the magnetometer and written into the MAG_[X-Z] and RHALL fields of the register DATA. For write accesses, no burst write is supported, independent of the settings in mag_rd_burst in Register (0x4B-0x4F) MAG_IF. When a read or write operation is triggered by writing to MAG_IF[2] or MAG_IF[3], a bit indicator mag_man_op in Register (0x1B) STATUS is set and when the operation is completed it is automatically reset. In case a measurement trigger is necessary (i.e. BMM150), the MAG-sensor register address and data should be specified by writing the appropriate value (i.e. 0x06) in the required external sensor register address (i.e. 0x44) through the last indirect write access in setup mode before changing to Data mode. The time delay between triggering a magnetometer measurement and reading the measured data is specified in mag_offset in MAG_IF[1]. The data rate used for the autonomous reading of the MAG-sensor data in Data mode should be first specified by configuring the mag_odr in Register (0x44) MAG_CONF<0:3>. 2. Data mode: When collecting sensor data in Data mode, the BMI160 autonomously triggers the measurement of the magnetometer, reads the data from the magnetometer and copies it into the BMI160 user register. Once the data mode is running, the application processor can access the data of the secondary sensor simply by reading from the BMI160 user Register (0x04-0x17) DATA_0 Register (0x04-0x17) DATA_7 0x0b. In case of BMM150, the data read is the magnetometer data MAG_[X-Z] and Hall resistance RHALL. The data mode mode is enabled by setting the MAG_IF_1<7> = 0. MAG_IF[2] defines the lowest address of the register data bytes to read from the MAG-sensor and the data will be stored in the BMI160 register MAG-DATA. The data ready status is set via drdy_mag in BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 98 Register (0x1B) STATUS, but this operation never clears drdy_mag, it is typically cleared through reading the Register (0x04-0x17) DATA. If DRDY is not active the error bit mag_drdy_err in Register (0x02) ERR_REG is set. MAG_IF[3] defines the register address of the magnetometer to start a measurement in forced mode in the magnetometer register map. Reading of the data is done in a single I2C read operation with a burst length of 8 bytes. 3.3.2 Camera module connected to secondary interface for OIS BMI160 supports specific optical image stabilization (OIS) applications with a dedicated interface. This interface is used for direct access to pre-filtered gyroscope data with minimum latency. Prefiltered gyroscope data is available at output data rate (ODR) of 6.4 kHz and can be read out via OIS fast mode SPI interface at 10MHz maximum speed. The OIS SPI interface supports 3-wire SPI as well as 4-wire SPI. The timings of the secondary SPI interface are the same as for the primary SPI interface, see chapter 3.2.2. The connection diagrams are depicted in chapter 4.3. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 99 4. Pin-out and Connection diagrams 4.1 Pin-out Pin1 marker 2 (ASDx) 12 (CSB) 13 (SCX) Top View BMI160 11 (OSDO) 11 (OSDO) 10 (OSCB) 10 (OSCB) 7 (GND) 8 (VDD) 8 (VDD) Figure 31: Pin-out top view 3 (ASCX) 5 (VDDIO) 9 (INT2) 6 (GNDIO) 9 (INT2) 7 (GND) 6 (GNDIO) 2 (ASDX) (Pads visible!) 3 (ASCx) 5 (VDDIO) 1 (SDO) Bottom View BMI160 (Pads not visible!) 4 (INT1) 14 (SDX) 1 (SDO) 13 (SCX) 12 (CSB) 14 (SDX) Pin1 4 (INT1) Figure 32: Pin-out bottom view Table 30: BMI160 Pin-out and pin connections are described in the table below Pin# Name I/O Type Interface Description 1 SDO Digital I/O Primary Serial data output in SPI Address select in I2C mode 2 ASDx Secondary Magnetometer interface**) 3 ASCx Secondary Magnetometer interface**) 4 INT1 Digital I/O Primary Interrupt pin 1 *) 5 VDDIO Supply - 6 7 8 GNDIO GND VDD - 9 INT2 Ground Ground Supply Digital I/O Digital I/O supply voltage (1.2 ... 3.6V) Ground for I/O Ground for digital & analog Power supply analog & digital domain (1.71V - 3.6V) Primary Interrupt pin 2 *) 10 OCSB Secondary OIS interface**) 11 OSDO Secondary OIS interface**) 12 CSB Digital I/O Digital in Primary 13 SCx Digital in Primary Chip select for SPI mode / Protocol selection pin SCK for SPI serial clock SCL for IC serial clock 14 SDx Digital I/O Primary Digital I/O Digital out Digital I/O SDA serial data I/O in I2C MOSI serial data input in SPI 4W SISO serial data I/O in SPI 3W *) If INT1 and/or INT2 are not used, please do not connect them (DNC) *)) If pins ASDX, ASCX, OCSB, OSDO are not used, they will be high impedance status BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 100 4.2 Connection diagrams to use primary interface only 4.2.1 I2C as primary interface SA0 SDA CSB 12 13 14 Top View (Pads not visible!) 9 100nF VDDIO OSCB INT1 INT2 INT2 VDD 100nF R R 8 OSDO GND 4 7 10 VDDIO INT1 3 11 BMI160 6 ASCx 2 GNDIO ASDx 1 5 SDO SCX SDX SCL VDD Figure 33: Only I2C as primary interface 4.2.2 SPI 3-wire as primary interface SDA SCK 12 13 CSB 10 9 8 100nF 100nF VDDIO 7 4 6 Top View (Pads not visible!) 11 OSDO OSCB INT1 INT2 INT2 VDD GND 3 BMI160 VDDIO INT1 14 SDX ASCx 2 5 ASDx 1 GNDIO SDO SCX CSB VDD Figure 34: Only SPI 3-wire as primary interface BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 101 4.2.3 SPI 4-wire as primary interface MISO MOSI 2 CSB 12 9 VDDIO INT1 INT2 INT2 VDD 8 100nF VDDIO 5 4 OSCB 100nF INT1 10 Top View (Pads not visible!) 7 3 OSDO 11 BMI160 6 ASCx CSB GND ASDx 13 SDX 14 1 GNDIO SDO SCX SCK VDD Figure 35: Only SPI 4-wire as primary interface 4.3 Connection diagrams to use additional secondary interface 4.3.1 Primary SPI 4-wire and secondary magnetometer interface (I2C) MISO MOSI SDA R ASDx 2 CSB CSB 12 1 13 SDO R 14 VDDIO SCX SDX SCK 11 BMI160 10 Top View (Pads not visible!) 9 OSDO OSCB INT1 4 7 3 5 ASCx SCL 6 to BMM 8 INT2 INT2 VDD GNDIO GND 100nF VDDIO 100nF VDDIO INT1 VDD Figure 36: Using SPI 4-wire and the magnetometer interface BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 102 4.3.2 Primary SPI 3-wire and secondary magnetometer interface (I2C) SISO SCK ASDx SDA to BMM ASCx 1 2 3 CSB CSB 12 SDO 13 R 14 R SCX SDX VDDIO 11 BMI160 10 Top View (Pads not visible!) 9 OSDO OSCB INT2 INT2 4 6 5 INT1 7 SCL 8 VDD 100nF 100nF GND VDDIO GNDIO INT1 VDDIO VDD Figure 37: Using SPI 3-wire and the magnetometer interface 4.3.3 Primary I2C and secondary magnetometer interface (I2C) INT1 SA0 SDA SCL 4 R VDDIO CSB 12 9 VDDIO R Top View (Pads not visible!) 8 100nF INT1 10 7 3 BMI160 6 ASCx SCL 11 OSDO OSCB INT2 INT2 VDD GND 2 to BMM GNDIO ASDx SDA 1 13 SDX SDO 5 R 100nF R 14 VDDIO SCX VDDIO VDD Figure 38: Using I2C and the magnetometer interface BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 103 4.3.4 Primary I2C and secondary 4-wire SPI as OIS interface SA0 SDA CSB 12 1 13 14 SDO SCX SDX SCL 11 MISO OSDO OIS Interface MOSI ASDx OIS Interface ASCx 2 3 BMI160 10 Top View (Pads not visible!) 9 7 INT1 8 INT2 INT2 VDD 100nF VDDIO CSB GND 5 GNDIO R 100nF R 4 VDDIO INT1 6 SCK OSCB VDD Figure 39: Using I2C and 4-wire SPI as OIS interface 4.3.5 Primary I2C and secondary 3-wire SPI as OIS interface SA0 SDA SCX CSB 12 1 13 SDO 14 SDX SCL 11 OSDO OIS Interface ASDx 2 OIS Interface ASCx 3 BMI160 10 Top View (Pads not visible!) 9 VDDIO 7 CSB OSCB INT1 8 INT2 INT2 VDD GND R GNDIO 5 VDDIO R 4 100nF INT1 6 SCK 100nF SISO VDD Figure 40: Using I2C and 3-wire SPI as OIS interface BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 104 5. Package 5.1 Outline Dimensions The package dimension is LGA 2.5mm x 3.0mm x 0.83mm. Unit of the following drawing is mm. Note: Unless otherwise specified tolerance = decimal 0.05 mm. 0.83 0.05 0.70 0.05 Figure 41: Packaging outline dimensions Note: Pin1 marker is internally connected to Pin1. It must not be connected to a different signal than Pin1. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 105 5.2 Sensing axes orientation If the sensor is accelerated and/or rotated in the indicated directions, the corresponding channels of the device will deliver a positive acceleration and/or yaw rate signal (dynamic acceleration). If the sensor is at rest without any rotation and the force of gravity is acting contrary to the indicated directions, the output of the corresponding acceleration channel will be positive and the corresponding gyroscope channel will be "zero" (static acceleration). Example: If the sensor is at rest or at uniform motion in a gravity field according to the figure given below, the output signals are: * * * 0g for the X ACC channel 0g for the Y ACC channel + 1g for the Z ACC channel and 0/sec for the X GYR channel and 0/sec for the Y GYR channel and 0/sec for the Z GYR channel Z X Y Figure 42: definition of sensing axes orientation For reference the figure below shows the Android device orientation with an integrated BMI160. BMI160 Figure 43: Android axis definition with BMI160 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 106 5.3 Landing pattern recommendation The following landing pad recommendation is given for maximum stability of the solder connections. 0.475 PinPin 1 Marker 1 marker 14 13 12 2 10 3 9 4 8 2. 5 0.5 11 0.25 1 6 0.675 5 7 0.925 3.0 Figure 44: Landing pattern recommendation for BMI160 Note: Pin1 marker is internally connected to Pin1. It must not be connected to a different signal than Pin1. The size of the landing pads may be further reduced in order to minimize solder-stress induced effects if sufficient control over the soldering process is given. Please contact your sales representative for further details. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 107 5.4 Marking 5.4.1 Mass production marking Table 31: Marking of mass samples Labeling CCC VL Name Symbol Remark Counter ID CCC 3 alphanumeric digits, variable to generate trace-code T Product identifier V = "T" denoting BMI160 First letter second row of Second letter of L second row Pin 1 identifier * Internal use -- 5.4.2 Engineering samples Table 32: Marking of engineering samples Labeling VLE CC Name Symbol Remark Internal ID VLE Product identifier V = "T" denoting BMI160 and "E" denotes engineering status L - internal use Second row CC -C - internal revision ID Pin 1 identifier * -- BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 108 5.5 Soldering guidelines The moisture sensitivity level of the BMI160 sensors corresponds to JEDEC Level 1, see also IPC/JEDEC J-STD-020C "Joint Industry Standard: Moisture/Reflow Sensitivity Classification for non-hermetic Solid State Surface Mount Devices" IPC/JEDEC J-STD-033A "Joint Industry Standard: Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices" The sensor fulfils the lead-free soldering requirements of the above-mentioned IPC/JEDEC standard, i.e. reflow soldering with a peak temperature up to 260C. 260 C Figure 45: Soldering profile BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 109 5.6 Handling instructions Micromechanical sensors are designed to sense acceleration with high accuracy even at low amplitudes and contain highly sensitive structures inside the sensor element. The MEMS sensor can tolerate mechanical shocks up to several thousand g's. However, these limits might be exceeded in conditions with extreme shock loads such as e.g. hammer blow on or next to the sensor, dropping of the sensor onto hard surfaces etc. We recommend to avoid g-forces beyond the specified limits during transport, handling and mounting of the sensors in a defined and qualified installation process. This device has built-in protections against high electrostatic discharges or electric fields (e.g. 2kV HBM); however, anti-static precautions should be taken as for any other CMOS component. Unless otherwise specified, proper operation can only occur when all terminal voltages are kept within the supply voltage range. Unused inputs must always be tied to a defined logic voltage level. 5.7 Tape and reel specification The BMI160 is shipped in a standard cardboard box. The box dimension for 1 reel is: L x W x H = 35 cm x 35 cm x 6 cm. BMI160 quantity: 5,000pcs per reel, please handle with care. A0 = 3.30, B0 = 2.80, K0 = 1.10 Note: Tolerances unless noted: 0.1 Sprocket hole pitch cumulative tolerance 0.1 Camber in compliance with EIA481 Pocket position relative to sprocket hole measured as true position of pocket, not pocket hole A0 and B0 are calculated on a plane at a distance "R" above the bottom of the pocket Figure 46: Tape and reel dimensions in mm BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 110 5.7.1 Orientation within the reel Processing direction Figure 47: Orientation of the BMI160 devices relative to the tape 5.8 Environmental safety The BMI160 sensor meets the requirements of the EC restriction of hazardous substances (RoHS) directive, see also: Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 5.8.1 Halogen content The BMI160 is halogen-free. For more details on the analysis results please contact your Bosch Sensortec representative. 5.8.2 Multiple sourcing Within the scope of Bosch Sensortec's ambition to improve its products and secure the mass product supply, Bosch Sensortec employs multiple sources in the supply chain. While Bosch Sensortec takes care that all of technical parameters are described above are 100% identical for all sources, there can be differences in device marking and bar code labeling. However, as secured by the extensive product qualification process of Bosch Sensortec, this has no impact to the usage or to the quality of the product. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 111 6. Legal disclaimer 6.1 Engineering samples Engineering Samples are marked with an asterisk (*) or (e) or (E). Samples may vary from the valid technical specifications of the product series contained in this data sheet. They are therefore not intended or fit for resale to third parties or for use in end products. Their sole purpose is internal client testing. The testing of an engineering sample may in no way replace the testing of a product series. Bosch Sensortec assumes no liability for the use of engineering samples. The Purchaser shall indemnify Bosch Sensortec from all claims arising from the use of engineering samples. 6.2 Product use Bosch Sensortec products are developed for the consumer goods industry. They may only be used within the parameters of this product data sheet. They are not fit for use in life-sustaining or security sensitive systems. Security sensitive systems are those for which a malfunction is expected to lead to bodily harm or significant property damage. In addition, they are not fit for use in products which interact with motor vehicle systems. The resale and/or use of products are at the purchaser's own risk and his own responsibility. The examination of fitness for the intended use is the sole responsibility of the Purchaser. The purchaser shall indemnify Bosch Sensortec from all third party claims arising from any product use not covered by the parameters of this product data sheet or not approved by Bosch Sensortec and reimburse Bosch Sensortec for all costs in connection with such claims. The purchaser must monitor the market for the purchased products, particularly with regard to product safety, and inform Bosch Sensortec without delay of all security relevant incidents. 6.3 Application examples and hints With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Bosch Sensortec hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights or copyrights of any third party. The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. They are provided for illustrative purposes only and no evaluation regarding infringement of intellectual property rights or copyrights or regarding functionality, performance or error has been made. BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice. BMI160 Data sheet Page 112 7. Document history and modifications Rev. No Chapter 2.2.4 2.5.1.5 2.5.2.4 2.7 0.9 2.11 2.11.37 2.5.1.5 2.4.1 2.6.2 3.2.2 3.3.2 2.2.4 1.1 3.3.1 3.3.1.1 2.11.15 4.3.1 4.3.2 4.3.3 5.3 2.6.7 2.11.24 4.1 Description of modification/changes Table 8 updated Explanation updated how to configure external interrupt tags, Description of FIFO config frame updated Description of Step Counter updated Updated hyperlink Date Register description updated Description updated Table 13 updated Flow diagram updated SDO output delay time added Max. speed of OIS I/F updated Current consumption in Table 8 corrected Current consumption in Table 1 corrected Current consumption in General Description corrected External pull-up resistors need to be connected Updated content Updated ODR formula 16th Oct 2018 Updated pull-ups in the recommended connection diagrams Updated landing pattern Updated low-g feature description Updated register description Updated comments in Table 30 Bosch Sensortec GmbH Gerhard-Kindler-Strasse 8 72770 Reutlingen / Germany contact@bosch-sensortec.com www.bosch-sensortec.com Modifications reserved | Printed in Germany Subject to change without notice Document number: BST-BMI160-DS000-08 Revision_0.9_102018 BST-BMI160-DS000-08 | Revision 0.9 | October 2018 Bosch Sensortec (c) Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are preliminary and subject to change without notice.