Solid state relays - GA1 and GA8 range PCB-mountable (flat pack = GA1, SIP = GA8) Rating: 4 A-5 A Peak voltage: 600 V Will withstand a 1-cycle 100 A surge TRIAC outputs UL - cUL 3 A approval and CE marking Zero voltage or instantaneous switching (5A only) Input to output insulation voltage: 4000 V Protection by RC filter GA1 Output specifications GA8 1 Part numbers Voltage range (Vrms) Peak voltage (Vpeak) Maximum current (Vpeak) Minimum current (Vpeak) Max. 1-cycle surge (Apeak) Maximum off-state leakage (mArms) On-state voltage drop at Imax and T =25C (V peak) Static (off-state) dv/dt (Vs) Maximum response time (close) Supply frequency range 24-280 600 4 or 5 depending on part no. 0.05 100 6 1.6 24-280 850 3 200 0.5 cycle 200 0.5 cycle 47 to 63 47 to 63 0.05 100 6 1.65 Input specifications Input voltage 3-32 V c 3-32 V c 3-32 V c 3-32 V c 84 064 131 84 065 131 84 065 030 84 065 040 Instantaneous switching Rating Range Output voltage 5A GA 8 24-280 V a 3A GA 8 24-480 V a Input voltage 3-32 V c 3-32 V c 84 025 030 84 025 040 2 Accessories 3-32 c 1 25 regulated Input voltage (V) Drop-out voltage (V c) Maximum current at Vmax (mA) Nominal input resistance (k) Zero voltage switching Rating Range Output voltage 4A GA 1 24-280 V a GA 8 24-280 V a 5A GA 8 24-280 V a 3A GA 8 24-480 V a Quick-blow fuses (see page 4/32) Equivalent circuits Characteristics Operating temperature (C) Storage temperature (C) Input to output insulation voltage (Vrms) Input/output capacitance (pF) Weight (g) 4 -30 to +80 -40 to +100 4000 8 15 + Curves for temperature-dependent derating Dimensions (General tolerances +/- 0.5) 27,9 3,8 3,8 30,5 2 1 0 O 1,0 10 20 30 40 50 60 70 80 Ambient temperature (C) 25,4 3+ 20,3 3 35,5 30,5 38,2 4 7,6 7,6 17,8 1 2 Rating (Vpeak) 9,5 4 43,2 2,5 6,4 GA 8 10,2 35,6 2 3 4 GA 1 1 Matching and trigger circuit (Zero voltage) 0,89 4 3 5,9 2 I 3 1 2 O 1,1 1 001738G2 0 20 40 To order, specify: Standard products 1 Standard products, non stocked Part number 001739G2 2 Accessory Example: Solid state relay - GA8 range - 84 065 131 - Fuse Z 084 363 4/22 60 80 C