4/22
4
Part numbers
Zero voltage switching
Rating Range Output voltage Input voltage
4 A GA 1 24-280 V a3-32 V c84 064 131
GA 8 24-280 V a3-32 V c84 065 131
5 A GA 8 24-280 V a3-32 V c84 065 030
3 A GA 8 24-480 V a3-32 V c84 065 040
Instantaneous switching
Rating Range Output voltage Input voltage
5 A GA 8 24-280 V a3-32 V c 84 025 030
3 A GA 8 24-480 V a3-32 V c 84 025 040
Accessories
Quick-blow fuses (see page 4/32)
Equivalent circuits
Curves for temperature-dependent derating
Ambient temperature (°C)
Rating (Vpeak)
■PCB-mountable (flat pack = GA1, SIP = GA8)
■Rating: 4 A-5 A
■Peak voltage: 600 V
■Will withstand a 1-cycle 100 A surge
■TRIAC outputs
■
UL - cUL 3 A approval and CE marking
■Zero voltage or instantaneous switching
(5A only)
■Input to output insulation voltage: 4000 V
■Protection by RC filter
To order, specify:
Output specifications
Voltage range (Vrms) 24-280 24-280
Peak voltage (Vpeak) 600 850
Maximum current (Vpeak)
4 or 5 depending
3
on part no.
Minimum current (Vpeak) 0.05 0.05
Max. 1-cycle surge (Apeak) 100 100
Maximum off-state leakage (mArms) 6 6
On-state voltage drop at 1.6 1.65
Imax and T =25°C (V peak)
Static (off-state) dv/dt (Vµs) 200 200
Maximum response time 0.5 cycle 0.5 cycle
(close)
Supply frequency range 47 to 63 47 to 63
Input specifications
Input voltage (V) 3-32 cc
Drop-out voltage (V c)1
Maximum current at Vmax (mA) 25
Nominal input resistance (kΩ) regulated
Characteristics
Operating temperature (°C) -30 to +80
Storage temperature (°C) -40 to +100
Input to output insulation voltage (Vrms) 4000
Input/output capacitance (pF) 8
Weight (g) 15
Solid state relays - GA1 and GA8 range
Dimensions (General tolerances +/- 0.5)
GA 1 GA 8