Product
Specification 108-2085
15Dec09 Rev A
Standard Range SIAMEZE* Insulation Displacement
Terminals
©2009 Tyco Electronics Corporation
Harrisburg, PA
All International Rights Reserved.
* Trademark
| Indicates change For latest revision, visit our website at www.tycoelectronics.com\documents.
For Regional Customer Service, visit our website at www.tycoelectronics.com 1 of 5
LOC B
1. SCOPE
1.1. Content
This specification covers performance, tests and quality requirements for Standard Range SIAMEZE*
Insulation Displacement Terminals designed for general use as a magnet wire to external interface
when inserted into a plastic pocket (cavity) designed to Tyco Electronics guidelines. The terminal is
compatible with Single and Double build copper magnet wire 18 through 34 AWG (1.02 through 0.16
mm). Unless otherwise specified on the Tyco Electronics Customer drawing, connection is to be made
to an individual magnet wire or solid bare copper wire.
1.2. Qualification
When tests are performed on the subject product line, procedures specified in Figure 1 shall be used.
All inspections shall be performed using the applicable inspection plan and product drawing.
1.3. Successful qualification testing on the subject product line was completed on 04Dec09. The
Qualification Test Report number for this testing is 501-723. This documentation is on file at and
available from Engineering Practices and Standards (EPS).
2. APPLICABLE DOCUMENTS
The following documents form a part of this specification to the extent specified herein. Unless
otherwise specified, the latest edition of the document applies. In the event of conflict between the
requirements of this specification and the product drawing, the product drawing shall take precedence.
In the event of conflict between the requirements of this specification and the referenced documents,
this specification shall take precedence.
2.1. Tyco Electronics Documents
!114-13166: Application Specification (SIAMEZE Standard and Fine Range Terminals)
!501-723: Qualification Test Report (Standard Range SIAMEZE* Insulation Displacement
Terminals)
2.2. Industry Standard
EIA-364: Electrical Connector/Socket Test Procedures Including Environmental Classifications
2.3. Reference Document
109-197: Test Specification (AMP Test Specifications vs EIA and IEC Test Methods)
3. REQUIREMENTS
3.1. Design and Construction
Product shall be of the design, construction and physical dimensions specified on the applicable product
drawing.
3.2. Materials
Materials used in the construction of this product shall be as specified on the applicable product
drawing.
108-2085
Rev A 2 of 5
3.3. Performance and Test Description
Product is designed to meet the electrical, mechanical and environmental performance requirements
specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental
conditions. All electrical and environmental tests shall be performed with the terminals inserted into a
Tyco Electronics bobbin with a connection configuration per Figure 3.
3.4. Test Requirements and Procedures Summary
Test Description Requirement Procedure
Initial examination of product. Meets requirements of product
drawing. EIA-364-18.
Visual and dimensional (C of C)
inspection per product drawing.
Final examination of product. Meets visual requirements. EIA-364-18.
Visual inspection.
ELECTRICAL
Low Level Contact Resistance
(LLCR). 20% maximum increase from initial
LLCR reading.
See Figure 3.
EIA-364-23.
Subject specimens to 100
milliamperes maximum and 20
millivolts maximum open circuit
voltage.
Current cycling. See Figure 4. EIA-364-55, Test Condition A, Test
Method 2.
Subject specimens to 100% of rated
current for wire size being tested for
250 cycles of 15 minutes ON and
15 minutes OFF.
MECHANICAL
Retention force. 45 N [10 lbf] minimum for single
barb.
90 N [20 lbf] minimum for multiple
barb.
See Note 1.
65 N [15 lbf] minimum for stranded
lead wire with Lead Lok.
See Note 2.
EIA-364-8.
Determine retention force at a
maximum rate of 25.4 mm [1 in] per
minute.
ENVIRONMENTAL
Thermal shock. See Note 3. EIA-364-32.
Subject specimens to 25 cycles
between -40 and 125EC.
Humidity/temperature cycling. See Note 3. EIA-364-31, Method III.
Subject specimens to 10 cycles (10
days) between 25 and 65EC at 80 to
100% RH.
Figure 1 (continued)
108-2085
Test Description Requirement Procedure
Rev A 3 of 5
Temperature life. See Note 3. EIA-364-17.Subject specimens to
118°C for 33 days.
(1) Vertical force required to extract the terminal from a pocket (cavity) molded to Tyco
NOTE Electronics guidelines in Nylon 6/6 30% GF.
(2) Vertical force required to extract a PVC insulated stranded lead wire secured with Lead Lok
from a pocket (cavity) molded in Nylon 6/6 30% GF that complies with Tyco Electronics
specifications.
(2) Shall meet visual requirements, show no physical damage, and meet the requirements of
additional tests as specified in the Product Qualification and Requalification Test Sequence
shown in Figure 2.
Figure 1 (end)
3.5. Product Qualification and Requalification Test Sequence
Test or Examination Test Group (a)
1234
Test Sequence (b)
Initial examination of product 1111
LLCR 2,5 2,4 2,4
Current cycling 3
Retention force 2
Thermal shock 4
Humidity/temperature cycling 3
Temperature life 3
Final examination of product 6535
(a) See paragraph 4.1.A.
NOTE (b) Numbers indicate sequence in which tests are performed.
Figure 2
108-2085
Rev A 4 of 5
4. QUALITY ASSURANCE PROVISIONS
4.1. Qualification Testing
A. Specimen Selection
Specimens shall be prepared in accordance with Application Specification 114-13166 and shall be
selected at random from current production. Each test group shall consist of 30 terminals (15
interconnected bobbin assemblies) with the smallest and largest magnet wire size.
B. Test Sequence
Qualification inspection shall be verified by testing specimens as specified in Figure 2.
4.2. Requalification Testing
If changes significantly affecting form, fit or function are made to the product or manufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determined by development/product, quality and reliability engineering.
4.3. Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to
confirm corrective action is required before resubmittal.
4.4. Quality Conformance Inspection
The applicable quality inspection plan shall specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
108-2085
Rev A 5 of 5
Figure 3
Test Configuration
Wire Size
(AWG [mm i]) Current Carrying
Capacity (amperes) Wire Size
(AWG [mm i]) Current Carrying
Capacity (amperes)
18 [1.02] 13 27 [0.36] 3.5
19 [0.91] 11 28 [0.32] 3
20 [0.81] 10 29 [0.29] 2.5
21 [0.72] 9 30 [0.25] 2
22 [0.65] 8 31 [0.23] 1.5
23 [0.57] 7 32 [0.20] 1
24 [0.51] 6 33 [0.18] 1
25 [0.46] 5 34 [0.16] .75
26 [0.40] 4
Figure 4