RQ-65 65W Quad Output Switching Power Supply series Features : Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test High realibility SPECIFICATION MODEL OUTPUT INPUT RQ-65B RQ-65C RQ-65D DC VOLTAGE 5V 12V -5V -12V 5V 15V -5V -15V 5V 12V 24V -12V RATED CURRENT 6A 2A 0.5A 0.5A 5A 2A 0.5A 0.5A 4A 1.5A 1A 0.5A 0.2 ~ 3A 0 ~ 1A 0 ~ 1A 0.5 ~ 8A 0.2 ~ 3A 0 ~ 1A 0 ~ 1A 0.5 ~ 8A 0.2 ~ 3A 0.1 ~ 1.5A 0 ~ 1A CURRENT RANGE Note.6 0.5 ~ 8A RATED POWER Note.6 62.5W 65W 68W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 180mVp-p 80mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V 6.0% VOLTAGE TOLERANCE Note.3 2.0% 5.0% 5.0% CH1: 4.75 ~ 5.5V 2.0% +8,-4% 8.0% 5.0% Note.4 0.5% 1.5% 0.5% 0.5% 0.5% 1.5% 0.5% 0.5% 0.5% 1.5% 2.0% 0.5% LOAD REGULATION Note.5 0.5% 3.0% 1.0% 1.0% 0.5% 3.0% 1.0% 1.0% 0.5% 3.0% 4.0% 1.0% 500ms, 20ms, 50ms/230VAC VOLTAGE RANGE 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 76% AC CURRENT INRUSH CURRENT(max.) 2A/115VAC 1.2A/230VAC COLD START 40A/230VAC 5.0% CH1: 4.75 ~ 5.5V 2.0% 6.0% LINE REGULATION SETUP, RISE, HOLD TIME 5.0% 1200ms, 30ms, 10ms/115VAC at full load 125 ~ 373VDC (300VAC peak 5sec. No damage) 76% LEAKAGE CURRENT <2mA / 240VAC OVER LOAD 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 78% Protection type : Hiccup mode, recovers automatically after fault condition is removed -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B (Note 7) OTHERS NOTE HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A MTBF 245.5Khrs min. MIL-HDBK-217F (25 129*98*38mm (L*W*H) 0.44Kg; 30pcs/13.2Kg/0.72CUFT DIMENSION PACKING ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:RQ-65-SPEC 2004-03-12 RQ-65 65W Quad Output Switching Power Supply Mechanical Specification Case No. 903 series Unit:mm 31 3 .5 7 122.5 1 8.25 2 3 3 98 5 8 5 .5 33 2- M 4 7 6 7 8 3 .5 73.5 4.5 129 6.5 32 3 9 38 3 .5 3 .5 3 -M 18 1 8 .5 9 9 .5 120 77 Terminal Pin. No Assignment Assignment AC/L AC/N FG Pin No. 1 2 3 Pin No. 4 5 6 Assignment DC OUTPUT -V4 DC OUTPUT V3 DC OUTPUT +V2 Pin No. 7 8 Assignment DC OUTPUT COM DC OUTPUT +V1 Output Derating VS Input Voltage Derating Curve Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 -20 0 0 10 20 30 40 AMBIENT TEMPERATURE ( 50 ) 60 70 (VERTICAL) 60 50 40 88 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RQ-65-SPEC 2004-03-12