Temperature Sensor E52 A Wide Variety of High-precision Temperature Sensors * Ideal for the thermal input devices of Temperature Controllers. * Select from a wide variety of Temperature Sensors according to the temperature to be measured, location, and environment, and also according to the type and shape of the terminal. * General-purpose, low-cost, and exclusive models are available. Ordering Information List of Models Classification Generalpurpose Models Description TemperaElement ture range type (See note 3.) Sheathed E52-P@A platinum resistance E52-P@C thermometer 200qC to 450qC Standard E52-P@B platinum resistance E52-P@C thermometer 0qC to 450qC Sheathed thermocouple 0qC to 1,050qC Standard thermocouple Low-cost Models Model and appearance E52-CA@A E52-IC@A Pt100 K (CA) J (IC) Conductor type Class 3-conduc- B tor system Nongrounded type 2 (0.75) Protective tubing material SUS316 SUS316 Inconel Terminal type Page Exposed 4 lead wires Enclosed terminals 5 Exposed terminals 5 Enclosed terminals 6 Exposed 8 lead wires E52-CA@B E52-IC@B Exposed terminals 12 E52-CA@C E52-IC@C Enclosed terminals 12 Exposed terminals 13 Enclosed terminals 14 JIS ceramic Enclosed JIS special terminals ceramic 15 E52-CA@B E52-IC@B 0qC to 1,000qC SUS316 SUS310S E52-CA@C E52-IC@C E52-PR@C 0qC to 1,400qC R (PR) Low-cost E52-P10AE platinum E52-P6D resistance E52-P6F thermometer 50qC to 250qC Pt100 Low-cost thermocouple 0qC to 400qC K (CA) J (IC) E52-CA@AS E52-IC@AS 2 (0.25) 3-conduc- B tor system Nongrounded type SUS304 Exposed 17 lead wires 2 (0.75) 18 E52-CA1D E52-IC1D E52-CA6F E52-IC6F Grounded type 19 E52-CA10AE E52-IC10AE Nongrounded type 21 Note: 1. Exclusive models are provided on the following page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 3. The temperature range varies with the material, thickness, and construction of the protective tubing. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 1 E52 Classification Description Model and appearance Exclusive Models Bayonet spring for molding machines E52-CA2GV E52-IC2GV 0qC to 350qC K (CA) J (IC) Crimping terminals E52-CA1GT E52-IC1GT 0qC to 300qC Conductor type Class Grounded 2 (0.75) type Protective tubing material SUS304 Terminal type Page Exposed 21 lead wires 22 Used for E52-P2GS measuring surface temperatures 50qC to 250qC Used for E52-P10GR room temperature measurement 50qC to 60qC Double-el- E52-P20GW ement model 50qC to 250qC Two 3-conductor systems 23 WaterE52-P10GP proof model E52-P5A-40 0qC to 70qC 3-conductor system 23 Corrosion- E52-@@A-1 resistant model 80qC to 180qC Used for movable parts 0qC to 300qC K (CA) 100qC to 500qC E52-CA1D-40 Explosion- E52-@@C-6 proof model Thermistors TemperaElement ture range type (See note 3.) E52-THE5A E52-THE6F E52-THE6D Pt100 3-conduc- B tor system 22 22 50qC to 180qC Fluororesin molding 24 Fluororesin tubing 24 Grounded 2 (0.75) type --- 27 Pt100 3-conduc- B tor system SUS316 Enclosed terminals 100qC to 900qC K (CA) Nongrounded type 50qC to 300qC Thermistor Element- 1 interchangeable thermistor SUS304 Exposed 29 lead wires Pt100 3-conduc- B tor system K (CA) Nongrounded type 2 (0.75) 25 2 (0.75) Note: 1. General-purpose models and low-cost models are provided on the previous page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 3. The temperature range varies with the material, thickness, and construction of the protective tubing. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 2 E52 Accessories It is recommended that the following accessories be used for mounting Temperature Sensors. Accessory Temperature range Compression Fitting 600qC max. Mounting example Mounting with Compression Fitting Page 30 Terminal box Compression Fitting PT screw Welding Loose Flange 400qC max. Protective tubing Mounting with Loose Flange Terminal box Loose Flange Protective tubing Mounting screw Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. Note: 1. Use the Loose Flange in normal atmospheric pressure. The Loose Flange is not of airtight construction. 2. Use the Loose Flange at 400qC max. 3. Do not apply the Loose Flange to protective tubing diameters other than the applicable ones. Lead Wires Accessory For resistance thermometers For thermocouples (compensating conductor) Specification Temperature range 20qC to 70qC Standard Vinyl-covered with twelve 0.18-dia. conductors (0.3 mm thick) and 4.8 mm in outer dia. Heat resistive Glass-wool-covered with twenty 0.18-dia. conductors (0.5 mm thick) ex- 0qC to 180qC ternally shielded, 5.2 mm in outer dia. Sleeve: 0qC to 100qC Standard Vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and 3.2 x 5.0 mm in outer dia. 20qC to 70qC Heat resistive Vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) externally shielded, 2.9 x 4.6 mm in outer dia. 0qC to 150qC Sleeve: 0qC to 100qC Page --- 32 General-purpose Models Sheathed Platinum Resistance Thermometers Refer to Model Number Legend on page 7 for the Pt100. Specifications Element type Pt100 Class JIS class B Sheath material SUS316 Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia. Conductor type 3-conductor system Temperature range 200qC to 450qC (in dry air) http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 3 E52 Exposed-lead Models E52-P@A Dimensions Red (A) Unit (mm) Y-type crimp terminal for M4 Maker tube Lead wire SUS304 sleeve d White (B) D M Black (B) d l 3.2 dia. 8 60 4.8 dia. 8 60 6.4 dia. 8 60 D SUS316 sheath L Lead Wire * Standard (20qC to 70qC): Fully vinyl-covered with twelve 0.18-dia conductors (0.3 mm thick) and 4.8 mm in outer dia. The sleeve resists a temperature range between 0qC and 70qC. * Heat Resistive (0qC to 180qC): Fully glass-wool-covered with twenty 0.18-dia. conductors (0.5 mm thick) externally shielded, 5.2 mm in outer dia. The sleeve resists a temperature range between 0qC and 100qC. * Lead Wire Length (M): 1, 2, 4, or 8 m Model Information Custom-made models are available on request. Refer to page 7 for details. Terminal type Protective tubing diameter D (mm) Exposed-lead 3.2 dia. Models Protective tubing length L (cm) 15 35 1 2 4 8 20 Standard E52-P15A D=3.2 1M E52-P15A D=3.2 2M E52-P15A D=3.2 4M E52-P15A D=3.2 8M Heat resistive E52-P15A D=3.2 NETU 1M E52-P15A D=3.2 NETU 2M E52-P15A D=3.2 NETU 4M E52-P15A D=3.2 NETU 8M Standard E52-P20A D=3.2 1M E52-P20A D=3.2 2M E52-P20A D=3.2 4M E52-P20A D=3.2 8M Heat resistive E52-P20A D=3.2 NETU 1M E52-P20A D=3.2 NETU 2M E52-P20A D=3.2 NETU 4M E52-P20A D=3.2 NETU 8M Standard E52-P35A D=3.2 1M E52-P35A D=3.2 2M E52-P35A D=3.2 4M E52-P35A D=3.2 8M Heat resistive E52-P35A D=3.2 NETU 1M E52-P35A D=3.2 NETU 2M E52-P35A D=3.2 NETU 4M E52-P35A D=3.2 NETU 8M Standard E52-P20A D=4.8 1M E52-P20A D=4.8 NETU 1M E52-P20A D=4.8 2M E52-P20A D=4.8 NETU 2M E52-P20A D=4.8 4M E52-P20A D=4.8 NETU 4M E52-P20A D=4.8 8M E52-P20A D=4.8 NETU 8M Standard E52-P35A D=4.8 1M E52-P35A D=4.8 2M E52-P35A D=4.8 4M E52-P35A D=4.8 8M Heat resistive E52-P35A D=4.8 NETU 1M E52-P35A D=4.8 NETU 2M E52-P35A D=4.8 NETU 4M E52-P35A D=4.8 NETU 8M Standard E52-P50A D=4.8 1M E52-P50A D=4.8 2M E52-P50A D=4.8 4M E52-P50A D=4.8 8M Heat resistive E52-P50A D=4.8 NETU 1M E52-P50A D=4.8 NETU 2M E52-P50A D=4.8 NETU 4M E52-P50A D=4.8 NETU 8M Standard E52-P20A D=6.4 1M E52-P20A D=6.4 2M E52-P20A D=6.4 4M E52-P20A D=6.4 8M Heat resistive E52-P20A D=6.4 NETU 1M E52-P20A D=6.4 NETU 2M E52-P20A D=6.4 NETU 4M E52-P20A D=6.4 NETU 8M Standard E52-P35A D=6.4 1M E52-P35A D=6.4 2M E52-P35A D=6.4 4M E52-P35A D=6.4 8M Heat resistive E52-P35A D=6.4 NETU 1M E52-P35A D=6.4 NETU 2M E52-P35A D=6.4 NETU 4M E52-P35A D=6.4 NETU 8M Standard E52-P50A D=6.4 1M E52-P50A D=6.4 2M E52-P50A D=6.4 4M E52-P50A D=6.4 8M Heat resistive E52-P50A D=6.4 NETU 1M E52-P50A D=6.4 NETU 2M E52-P50A D=6.4 NETU 4M E52-P50A D=6.4 NETU 8M Heat resistive 35 50 6.4 dia. Lead wire length M (m) Model 20 4.8 dia. Lead wire type 20 35 50 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 4 E52 Enclosed-terminal Models E52-P@C Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. 34 dia. Aluminum die-cast terminal box 57 SUS304 SUS316 sheath D 65 4 16 19 Cap 35 G3/8, 19 mm between facing sides, 10 inner dia. (with 7-inner-dia. rubber bushing built-in) L Use wiring terminals that fit M3 screws. Terminal box: The permissible temperature is 0qC to 80qC. Note: The terminals in the cap indicate polarity (A, B, b). Model Information Custom-made models are available on request. Refer to page 7 for details. Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 3.2 dia. 4.8 dia. 6.4 dia. Model Enclosed-terminal Models 20 E52-P20C D=3.2 E52-P20C D=4.8 E52-P20C D=6.4 35 E52-P35C D=3.2 E52-P35C D=4.8 E52-P35C D=6.4 50 E52-P50C D=3.2 E52-P50C D=4.8 E52-P50C D=6.4 75 --- E52-P75C D=4.8 E52-P75C D=6.4 Standard Platinum Resistance Thermometers Refer to Model Number Legend on page 7 for the Pt100. Specifications Element type Pt100 Class JIS class B (See note 2.) Protective tubing material SUS316 Conductor type 3-conductor system Temperature range 0qC to 450qC (in dry air) Note: 1. Use the sheathed platinum resistance thermometer if condensation is likely to result. 2. Be sure that the thermometer is free of vibration or shock if high temperatures are measured. Exposed-terminal Models E52-P@B Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Aluminum die-cast terminal box SUS316 protective tubing 10 A 50 B Custom-made models are available on request. Refer to page 7 for details D B 18 Model Information 14 dia. Three, M3 20 Terminal type 20 dia. 40 L Terminal box: The permissible temperature is 0qC to 100qC. http://www.ia.omron.com/ Exposedterminal Models Protective Protective tubing diameter D (mm) tubing length 8 dia. L (cm) Model 20 E52-P20B D=8 35 E52-P35B D=8 50 E52-P50B D=8 (c)Copyright OMRON Corporation 2007 All Rights Reserved. 5 E52 Enclosed-terminal Models E52-P@C Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. 98 34 dia. Aluminum die-cast terminal box 22 dia. SUS316 protective tubing 57 SUS316 protective tubing 10 8 dia. 65 10 dia. 90 14 dia. Cap 35 G3/8, 19 mm between facing sides, 10 inner dia. (with 7-inner-dia. rubber bushing built-in) 10 40 dia. Aluminum die-cast terminal box (See note 1.) L - 40 Cap 57 Use wiring terminals that fit M3 screws. G1/2, 15-A ground (with 11-inner-dia. rubber bushing built-in) (See note 2.) L - 50 Use wiring terminals that fit M4 screws. Note: 1. The length L is in centimeters, but "40" is 40 millimeters. Therefore, for the E52-P20C, L = 20 (cm), the protective tubing length L 40 = 200 40 = 160 mm. 2. The length L is in centimeters, but "50" is 50 millimeters. Therefore, for the E52-P75C: L = 75 (cm), the protective tubing length L 50 = 750 50 = 700 mm. 3. Terminal box: The permissible temperature is 0qC to 80qC. Model Information Custom-made models are available on request. Refer to page 7 for details. Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 8 dia. 10 dia. Model Enclosed-terminal Models 20 E52-P20C D=8 --- 35 E52-P35C D=8 E52-P35C D=10 50 E52-P50C D=8 E52-P50C D=10 75 --- E52-P75C D=10 100 --- E52-P100C D=10 Note: The terminals in the cap indicate polarity (A, B, b). http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 6 E52 Model Number Structure The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Model Number Legend Platinum Resistance Thermometers E52-@@@ D=@@@M 1 2 3 4 5 6 1. Element type P: Pt100 2. Protective tubing length (L) Specify the length in centimeters within the following range: Unit (cm) E52-@@A Diameter (D) Length (L) 3.2 7 to 100 4.8 10 to 600 6.4 13 to 1,300 4. Diameter 3.2: 3.2-mm dia. (Protective tubing construction: Sheathed) E52-@@A and E52-@@C only 4.8: 4.8-mm dia. (Protective tubing construction: Sheathed) E52-@@A and E52-@@C only 6.4: 6.4-mm dia. (Protective tubing construction: Sheathed) E52-@@A and E52-@@C only 8: 8-mm dia. (Protective tubing construction: Standard) E52-@@B and E52-@@C only 10: 10-mm dia. (Protective tubing construction: Standard) E52-@@C only 5. Heat resistance E52-@@B Diameter (D) 8 Code Length (L) Diameter (D) Length (L) 3.2 12 to 100 4.8 15 to 600 6.4 18 to 1,300 8 21 to 100 10 26 to 100 Lead type 20qC to 70qC Sleeve: 0qC to 70qC Vinyl-covered NETU 0qC to 180qC Sleeve: 0qC to 100qC Glass-wool-covered, externally shielded 20 to 100 E52-@@C Temperature range --- Specify for E52-@@A model only. 6. Lead length (M) Specify the length in meters within the following range for the E52@@A only: Range: 1 to 100 m 3. Terminal A: Exposed lead wires B: Exposed terminals C: Enclosed terminals Note: Lead wires without crimp terminals (Y) are also available. Examples Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-P42A D=4.8 NETU 10M http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 7 E52 Sheathed Thermocouples Specifications Permissible Temperature in Dry Air Element type D K (CA), J(IC) Class Element wire K (CA) SUS316 JIS class 2 (0.75) J (IC) SUS316 Thermal contact Non-grounded type 1 dia. 650qC 450qC Sheath material CA: SUS316 1.6 dia. 650qC 450qC IC: SUS316 3.2 dia. 750qC 650qC 4.8 dia. 800qC 750qC 6.4 dia. 800qC 750qC 8.0 dia. 900qC 750qC Note: For details on the permissible temperature, refer to page D-5 of Introduction of Temperature Controllers (Cat. No. H900). Exposed-lead Models E52-CA@A Dimensions SUS304 sleeve (See note 2.) Y-type crimp terminal for M4 Red (+) Lead wire (See note 1.) Unit (mm) SUS316 sheath d White (-) M d l 1 dia. 7 40 1.6 dia. 7 40 1 dia. 650qC 3.2 dia. 7 40 1.6 dia. 650qC 4.8 dia. 7 40 3.2 dia. 750qC 6.4 dia. 10 45 4.8 dia. 800qC 8 dia. 10 45 6.4 dia. 800qC 8.0 dia. 900qC D D L Note: 1. Lead Wire (Compensating Conductor) * Standard (20qC to 70qC): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 3.2 u 5.0. * Heat Resistive (0qC to 150qC): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield and external dimensions of 2.9 u 4.6 * Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between 20qC and 70qC for standard models and 0qC and 100qC for heat-resistive models. Permissible Temperature in Dry Air D Element wire K (CA) SUS316 K (CA) Model Information (E52-CA@A) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 16 for details. Terminal type Protective Protective tubing diameter tubing length L D (mm) (cm) Lead wire type Lead wire length M (m) 1 2 4 8 Model Exposed-lead Models 1 dia. 15 20 35 1.6 dia. 15 20 35 Standard E52-CA15A D=1 1M E52-CA15A D=1 2M E52-CA15A D=1 4M E52-CA15A D=1 8M Heat resistive E52-CA15A D=1 NETU 1M E52-CA15A D=1 NETU 2M E52-CA15A D=1 NETU 4M E52-CA15A D=1 NETU 8M Standard E52-CA20A D=1 1M E52-CA20A D=1 2M E52-CA20A D=1 4M E52-CA20A D=1 8M Heat resistive E52-CA20A D=1 NETU 1M E52-CA20A D=1 NETU 2M E52-CA20A D=1 NETU 4M E52-CA20A D=1 NETU 8M Standard E52-CA35A D=1 1M E52-CA35A D=1 2M E52-CA35A D=1 4M E52-CA35A D=1 8M Heat resistive E52-CA35A D=1 NETU 1M E52-CA35A D=1 NETU 2M E52-CA35A D=1 NETU 4M E52-CA35A D=1 NETU 8M Standard E52-CA15A D=1.6 1M E52-CA15A D=1.6 2M E52-CA15A D=1.6 4M E52-CA15A D=1.6 8M Heat resistive E52-CA15A D=1.6 NETU 1M E52-CA15A D=1.6 NETU 2M E52-CA15A D=1.6 NETU 4M E52-CA15A D=1.6 NETU 8M Standard E52-CA20A D=1.6 1M E52-CA20A D=1.6 2M E52-CA20A D=1.6 4M E52-CA20A D=1.6 8M Heat resistive E52-CA20A D=1.6 NETU 1M E52-CA20A D=1.6 NETU 2M E52-CA20A D=1.6 NETU 4M E52-CA20A D=1.6 NETU 8M Standard E52-CA35A D=1.6 1M E52-CA35A D=1.6 2M E52-CA35A D=1.6 4M E52-CA35A D=1.6 8M Heat resistive E52-CA35A D=1.6 NETU 1M E52-CA35A D=1.6 NETU 2M E52-CA35A D=1.6 NETU 4M E52-CA35A D=1.6 NETU 8M http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 8 E52 Terminal type Protective Protective tubing diameter tubing length L D (mm) (cm) Lead wire type Lead wire length M (m) 1 2 4 8 Model Exposed-lead Models 3.2 dia. 15 20 35 50 4.8 dia. 20 35 50 6.4 dia. 20 35 50 8 dia. 20 35 50 http://www.ia.omron.com/ Standard E52-CA15A D=3.2 1M E52-CA15A D=3.2 2M E52-CA15A D=3.2 4M E52-CA15A D=3.2 8M Heat resistive E52-CA15A D=3.2 NETU 1M E52-CA15A D=3.2 NETU 2M E52-CA15A D=3.2 NETU 4M E52-CA15A D=3.2 NETU 8M Standard E52-CA20A D=3.2 1M E52-CA20A D=3.2 2M E52-CA20A D=3.2 4M E52-CA20A D=3.2 8M Heat resistive E52-CA20A D=3.2 NETU 1M E52-CA20A D=3.2 NETU 2M E52-CA20A D=3.2 NETU 4M E52-CA20A D=3.2 NETU 8M Standard E52-CA35A D=3.2 1M E52-CA35A D=3.2 2M E52-CA35A D=3.2 4M E52-CA35A D=3.2 8M Heat resistive E52-CA35A D=3.2 NETU 1M E52-CA35A D=3.2 NETU 2M E52-CA35A D=3.2 NETU 4M E52-CA35A D=3.2 NETU 8M Standard E52-CA50A D=3.2 1M E52-CA50A D=3.2 2M E52-CA50A D=3.2 4M E52-CA50A D=3.2 8M Heat resistive E52-CA50A D=3.2 NETU 1M E52-CA50A D=3.2 NETU 2M E52-CA50A D=3.2 NETU 4M E52-CA50A D=3.2 NETU 8M Standard E52-CA20A D=4.8 1M E52-CA20A D=4.8 2M E52-CA20A D=4.8 4M E52-CA20A D=4.8 8M Heat resistive E52-CA20A D=4.8 NETU 1M E52-CA20A D=4.8 NETU 2M E52-CA20A D=4.8 NETU 4M E52-CA20A D=4.8 NETU 8M Standard E52-CA35A D=4.8 1M E52-CA35A D=4.8 2M E52-CA35A D=4.8 4M E52-CA35A D=4.8 8M Heat resistive E52-CA35A D=4.8 NETU 1M E52-CA35A D=4.8 NETU 2M E52-CA35A D=4.8 NETU 4M E52-CA35A D=4.8 NETU 8M Standard E52-CA50A D=4.8 1M E52-CA50A D=4.8 2M E52-CA50A D=4.8 4M E52-CA50A D=4.8 8M Heat resistive E52-CA50A D=4.8 NETU 1M E52-CA50A D=4.8 NETU 2M E52-CA50A D=4.8 NETU 4M E52-CA50A D=4.8 NETU 8M Standard E52-CA20A D=6.4 1M E52-CA20A D=6.4 2M E52-CA20A D=6.4 4M E52-CA20A D=6.4 8M Heat resistive E52-CA20A D=6.4 NETU 1M E52-CA20A D=6.4 NETU 2M E52-CA20A D=6.4 NETU 4M E52-CA20A D=6.4 NETU 8M Standard E52-CA35A D=6.4 1M E52-CA35A D=6.4 2M E52-CA35A D=6.4 4M E52-CA35A D=6.4 8M Heat resistive E52-CA35A D=6.4 NETU 1M E52-CA35A D=6.4 NETU 2M E52-CA35A D=6.4 NETU 4M E52-CA35A D=6.4 NETU 8M Standard E52-CA50A D=6.4 1M E52-CA50A D=6.4 2M E52-CA50A D=6.4 4M E52-CA50A D=6.4 8M Heat resistive E52-CA50A D=6.4 NETU 1M E52-CA50A D=6.4 NETU 2M E52-CA50A D=6.4 NETU 4M E52-CA50A D=6.4 NETU 8M Standard E52-CA20A D=8 1M E52-CA20A D=8 2M E52-CA20A D=8 4M E52-CA20A D=8 8M Heat resistive E52-CA20A D=8 NETU 1M E52-CA20A D=8 NETU 2M E52-CA20A D=8 NETU 4M E52-CA20A D=8 NETU 8M Standard E52-CA35A D=8 1M E52-CA35A D=8 2M E52-CA35A D=8 4M E52-CA35A D=8 8M Heat resistive E52-CA35A D=8 NETU 1M E52-CA35A D=8 NETU 2M E52-CA35A D=8 NETU 4M E52-CA35A D=8 NETU 8M Standard E52-CA50A D=8 1M E52-CA50A D=8 2M E52-CA50A D=8 4M E52-CA50A D=8 8M Heat resistive E52-CA50A D=8 NETU 1M E52-CA50A D=8 NETU 2M E52-CA50A D=8 NETU 4M E52-CA50A D=8 NETU 8M (c)Copyright OMRON Corporation 2007 All Rights Reserved. 9 E52 Exposed-lead Models E52-IC@A Dimensions Y-type crimp terminal for M4 Red (+) SUS304 sleeve (See note 2.) Lead wire (See note 1.) Unit (mm) SUS316 sheath d White (-) M d l 1 dia. 7 40 1.6 dia. 7 40 1 dia. 450qC 3.2 dia. 7 40 1.6 dia. 450qC D D L Note: 1. Lead Wire (Compensating Conductor) * Standard (20qC to 70qC): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 3.2 u 5.0. * Heat Resistive (0qC to 150qC): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield and external dimensions of 2.9 u 4.6 * Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between 20qC and 70qC for standard models and 0qC and 100qC for heat-resistive models. Permissible Temperature in Dry Air D Element wire J (IC) SUS316 4.8 dia. 7 40 3.2 dia. 650qC 6.4 dia. 10 45 4.8 dia. 750qC 8 dia. 10 45 6.4 dia. 750qC 8.0 dia. 750qC J (IC) Model Information (E52-IC@A) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 16 for details Terminal type Protective tubing diameter D (mm) Exposed-lead 1 dia. Models Protective tubing length L (cm) Lead wire type 2 4 8 Model 15 20 Standard E52-IC15A D=1 1M E52-IC15A D=1 2M E52-IC15A D=1 4M E52-IC15A D=1 8M Heat resistive E52-IC15A D=1 NETU 1M E52-IC15A D=1 NETU 2M E52-IC15A D=1 NETU 4M E52-IC15A D=1 NETU 8M Standard E52-IC20A D=1 1M E52-IC20A D=1 NETU 1M E52-IC20A D=1 2M E52-IC20A D=1 NETU 2M E52-IC20A D=1 4M E52-IC20A D=1 NETU 4M E52-IC20A D=1 8M E52-IC20A D=1 NETU 8M Standard E52-IC35A D=1 1M E52-IC35A D=1 2M E52-IC35A D=1 4M E52-IC35A D=1 8M Heat resistive E52-IC35A D=1 NETU 1M E52-IC35A D=1 NETU 2M E52-IC35A D=1 NETU 4M E52-IC35A D=1 NETU 8M Standard E52-IC15A D=1.6 1M E52-IC15A D=1.6 2M E52-IC15A D=1.6 4M E52-IC15A D=1.6 8M Heat resistive E52-IC15A D=1.6 NETU 1M E52-IC15A D=1.6 NETU 2M E52-IC15A D=1.6 NETU 4M E52-IC15A D=1.6 NETU 8M Standard E52-IC20A D=1.6 E52-IC20A D=1.6 1M 2M E52-IC20A D=1.6 4M E52-IC20A D=1.6 8M Heat resistive E52-IC20A D=1.6 NETU 1M E52-IC20A D=1.6 NETU 2M E52-IC20A D=1.6 NETU 4M E52-IC20A D=1.6 NETU 8M Standard E52-IC35A D=1.6 E52-IC35A D=1.6 1M 2M E52-IC35A D=1.6 4M E52-IC35A D=1.6 8M Heat resistive E52-IC35A D=1.6 NETU 1M E52-IC35A D=1.6 NETU 4M E52-IC35A D=1.6 NETU 8M Heat resistive 35 1.6 dia. Lead wire length M (m) 1 15 20 35 http://www.ia.omron.com/ E52-IC35A D=1.6 NETU 2M (c)Copyright OMRON Corporation 2007 All Rights Reserved. 10 E52 Terminal type Protective tubing diameter D (mm) Exposed-lead 3.2 dia. Models Protective tubing length L (cm) 15 35 50 20 35 50 20 35 50 8 dia. 2 4 8 Standard E52-IC15A D=3.2 1M E52-IC15A D=3.2 2M E52-IC15A D=3.2 4M E52-IC15A D=3.2 8M Heat resistive E52-IC15A D=3.2 NETU 1M E52-IC15A D=3.2 NETU 2M E52-IC15A D=3.2 NETU 4M E52-IC15A D=3.2 NETU 8M Standard E52-IC20A D=3.2 1M E52-IC20A D=3.2 2M E52-IC20A D=3.2 4M E52-IC20A D=3.2 8M Heat resistive E52-IC20A D=3.2 E52-IC20A D=3.2 NETU 1M NETU 2M E52-IC20A D=3.2 NETU 4M E52-IC20A D=3.2 NETU 8M Standard E52-IC35A D=3.2 1M E52-IC35A D=3.2 2M E52-IC35A D=3.2 4M E52-IC35A D=3.2 8M Heat resistive E52-IC35A D=3.2 NETU 1M E52-IC35A D=3.2 NETU 2M E52-IC35A D=3.2 NETU 4M E52-IC35A D=3.2 NETU 8M Standard E52-IC50A D=3.2 1M E52-IC50A D=3.2 2M E52-IC50A D=3.2 4M E52-IC50A D=3.2 8M Heat resistive E52-IC50A D=3.2 E52-IC50A D=3.2 NETU 1M NETU 2M E52-IC50A D=3.2 NETU 4M E52-IC50A D=3.2 NETU 8M Standard E52-IC20A D=4.8 1M E52-IC20A D=4.8 2M E52-IC20A D=4.8 4M E52-IC20A D=4.8 8M Heat resistive E52-IC20A D=4.8 E52-IC20A D=4.8 NETU 1M NETU 2M E52-IC20A D=4.8 NETU 4M E52-IC20A D=4.8 NETU 8M Standard E52-IC35A D=4.8 1M E52-IC35A D=4.8 2M E52-IC35A D=4.8 4M E52-IC35A D=4.8 8M Heat resistive E52-IC35A D=4.8 NETU 1M E52-IC35A D=4.8 NETU 2M Standard E52-IC50A D=4.8 1M E52-IC50A D=4.8 NETU 1M E52-IC50A D=4.8 NETU 2M E52-IC50A D=4.8 NETU 4M E52-IC50A D=4.8 NETU 8M Standard E52-IC20A D=6.4 1M E52-IC20A D=6.4 2M E52-IC20A D=6.4 4M E52-IC20A D=6.4 8M Heat resistive E52-IC20A D=6.4 NETU 1M E52-IC20A D=6.4 NETU 2M E52-IC20A D=6.4 NETU 4M E52-IC20A D=6.4 NETU 8M Standard E52-IC35A D=6.4 1M E52-IC35A D=6.4 2M E52-IC35A D=6.4 4M E52-IC35A D=6.4 8M Heat resistive E52-IC35A D=6.4 NETU 1M E52-IC35A D=6.4 NETU 2M E52-IC35A D=6.4 NETU 4M E52-IC35A D=6.4 NETU 8M Standard E52-IC50A D=6.4 1M E52-IC50A D=6.4 2M E52-IC50A D=6.4 4M E52-IC50A D=6.4 8M Heat resistive E52-IC50A D=6.4 NETU 1M E52-IC50A D=6.4 NETU 2M E52-IC50A D=6.4 NETU 4M E52-IC50A D=6.4 NETU 8M Standard E52-IC20A D=8 1M E52-IC20A D=8 2M E52-IC20A D=8 4M E52-IC20A D=8 8M Heat resistive E52-IC20A D=8 NETU 1M E52-IC20A D=8 NETU 2M E52-IC20A D=8 NETU 4M E52-IC20A D=8 NETU 8M Standard E52-IC35A D=8 1M E52-IC35A D=8 2M E52-IC35A D=8 4M E52-IC35A D=8 8M Heat resistive E52-IC35A D=8 NETU 1M E52-IC35A D=8 NETU 2M E52-IC35A D=8 NETU 4M E52-IC35A D=8 NETU 8M Standard E52-IC50A D=8 1M E52-IC50A D=8 2M Heat resistive E52-IC50A D=8 NETU 1M E52-IC50A D=8 NETU 2M E52-IC50A D=8 4M E52-IC50A D=8 NETU 4M E52-IC50A D=8 8M E52-IC50A D=8 NETU 8M Heat resistive 6.4 dia. Lead wire length M (m) 1 Model 20 4.8 dia. Lead wire type 20 35 50 http://www.ia.omron.com/ E52-IC35A D=4.8 E52-IC35A D=4.8 NETU 4M NETU 8M E52-IC50A D=4.8 E52-IC50A D=4.8 E52-IC50A D=4.8 4M 8M 2M (c)Copyright OMRON Corporation 2007 All Rights Reserved. 11 E52 Exposed-terminal Models E52-CA@B E52-IC@B Dimensions Permissible Temperature in Dry Air Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Aluminum die-cast terminal box 22 dia SUS316 sheath + 45 D - D Element wire K (CA) SUS316 J (IC) SUS316 3.2 dia. 750qC 650qC 4.8 dia. 800qC 750qC 6.4 dia. 800qC 750qC 8.0 dia. 900qC 750qC Terminal box: The permissible temperature is 0qC to 100qC. 4 16 Two, M3 40 16 L Model Information Custom-made models are available on request. Refer to Model Number Legend on page 16 for details. Element type Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. Model K (CA) Exposed-terminal Models J (IC) Exposed-terminal Models 20 E52-CA20B D=3.2 E52-CA20B D=4.8 E52-CA20B D=6.4 --- 35 E52-CA35B D=3.2 E52-CA35B D=4.8 E52-CA35B D=6.4 E52-CA35B D=8 50 E52-CA50B D=3.2 E52-CA50B D=4.8 E52-CA50B D=6.4 E52-CA50B D=8 75 --- E52-CA75B D=4.8 E52-CA75B D=6.4 E52-CA75B D=8 20 E52-IC20B D=3.2 E52-IC20B D=4.8 E52-IC20B D=6.4 --- 35 E52-IC35B D=3.2 E52-IC35B D=4.8 E52-IC35B D=6.4 E52-IC35B D=8 50 E52-IC50B D=3.2 E52-IC50B D=4.8 E52-IC50B D=6.4 E52-IC50B D=8 75 --- E52-IC75B D=4.8 E52-IC75B D=6.4 E52-IC75B D=8 Enclosed-terminal Models E52-CA@C E52-IC@C Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Permissible Temperature in Dry Air D 34 dia. Element wire 57 K (CA) SUS316 14 dia. SUS316 sheath D 65 4 16 19 Aluminum die-cast terminal box 750qC 650qC 4.8 dia. 800qC 750qC 6.4 dia. 800qC 750qC 8.0 dia. 900qC 750qC Terminal box: The permissible temperature is 0qC to 80qC. Cap 35 G3/8, 19 mm between facing sides, 10 inner dia. (with 7-inner-dia. rubber bushing built-in) J (IC) SUS316 3.2 dia. Note: The terminals in the cap indicate polarity (+ or ). L-40 Use wiring terminals that fit M3 screws. Model Information Custom-made models are available on request. Refer to Model Number Legend on page 16 for details. Element type Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. Model K (CA) J (IC) Enclosed-terminal Models Enclosed-terminal Models 20 E52-CA20C D=3.2 E52-CA20C D=4.8 E52-CA20C D=6.4 --- 35 E52-CA35C D=3.2 E52-CA35C D=4.8 E52-CA35C D=6.4 E52-CA35C D=8 50 E52-CA50C D=3.2 E52-CA50C D=4.8 E52-CA50C D=6.4 E52-CA50C D=8 75 --- E52-CA75C D=4.8 E52-CA75C D=6.4 E52-CA75C D=8 20 E52-IC20C D=3.2 E52-IC20C D=4.8 E52-IC20C D=6.4 --- 35 E52-IC35C D=3.2 E52-IC35C D=4.8 E52-IC35C D=6.4 E52-IC35C D=8 50 E52-IC50C D=3.2 E52-IC50C D=4.8 E52-IC50C D=6.4 E52-IC50C D=8 75 --- E52-IC75C D=4.8 E52-IC75C D=6.4 E52-IC75C D=8 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 12 E52 Standard Thermocouples Specifications Permissible Temperature in Dry Air (See note.) D Element wire K (CA), J(IC), R Class K (CA), J (IC) JIS class 2 (0.75) Protective tubing material J (IC) SUS316 R, JIS class 2 (0.25) 10 dia. 750qC 450qC K (CA) SUS316 12 dia. 850qC 500qC J (IC) 15 dia. 850qC 550qC 22 dia. 900qC 600qC SUS316 R (See JIS ceramic cat. 1 (PT1) note.) JIS special ceramic (PT0) Thermal contact Element wire K (CA) SUS316 Non-grounded type Note: Specify PT1 or PT0 if the element is R. Note: For details on the permissible temperature, refer to Technical Guide for Temperature Sensors. D Element wire R 17 dia. 0qC to 1,400qC Exposed-terminal Models E52-CA@B E52-IC@B Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Aluminum die-cast terminal box 50 SUS316 protective tubing 10 + 70 D - 22 dia. Two, M3 26 L Terminal box: The permissible temperature is 0qC to 100qC. Permissible Temperature in Dry Air D Element wire K (CA) SUS316 J (IC) SUS316 10 dia. 750qC 450qC 12 dia. 850qC 500qC 15 dia. 850qC 550qC 22 dia. 900qC 600qC Model Information Custom-made models are available on request. Refer to Model Number Legend on page 16 for details Element type Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 10 dia. 12 dia. 15 dia. 22 dia. Model K (CA) J (IC) Exposed-terminal Models Exposed-terminal Models 35 E52-CA35B D=10 E52-CA35B D=12 E52-CA35B D=15 --- 50 E52-CA50B D=10 E52-CA50B D=12 E52-CA50B D=15 E52-CA50B D=22 75 E52-CA75B D=10 E52-CA75B D=12 E52-CA75B D=15 E52-CA75B D=22 100 E52-CA100B D=10 E52-CA100B D=12 E52-CA100B D=15 E52-CA100B D=22 35 E52-IC35B D=10 E52-IC35B D=12 E52-IC35B D=15 --- 50 E52-IC50B D=10 E52-IC50B D=12 E52-IC50B D=15 E52-IC50B D=22 75 E52-IC75B D=10 E52-IC75B D=12 E52-IC75B D=15 E52-IC75B D=22 100 E52-IC100B D=10 E52-IC100B D=12 E52-IC100B D=15 E52-IC100B D=22 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 13 E52 Enclosed-terminal Models E52-CA@C E52-IC@C Dimensions Permissible Temperature in Dry Air Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Aluminum die-cast terminal box 98 22 dia. SUS316 protective tubing D 90 D Element wire K (CA) SUS316 J (IC) SUS316 10 dia. 750qC 450qC 12 dia. 850qC 500qC 15 dia. 850qC 550qC 22 dia. 900qC 600qC Terminal box: The permissible temperature is 0qC to 80qC. 10 Note: The terminals in the cap indicate polarity (+ or ). 40 dia. Cap 57 L-50 G1/2, 15-A ground (with 11-inner-dia. rubber bushing built-in) Use wiring terminals that fit M4 screws. Model Information Custom-made models are available on request. Refer to Model Number Legend on page 16 for details Element type Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 10 dia. 12 dia. 15 dia. 22 dia. Model K (CA) J (IC) Enclosed-terminal Models Enclosed-terminal Models 35 E52-CA35C D=10 E52-CA35C D=12 E52-CA35C D=15 --- 50 E52-CA50C D=10 E52-CA50C D=12 E52-CA50C D=15 E52-CA50C D=22 75 E52-CA75C D=10 E52-CA75C D=12 E52-CA75C D=15 E52-CA75C D=22 100 E52-CA100C D=10 E52-CA100C D=12 E52-CA100C D=15 E52-CA100C D=22 35 E52-IC35C D=10 E52-IC35C D=12 E52-IC35C D=15 --- 50 E52-IC50C D=10 E52-IC50C D=12 E52-IC50C D=15 E52-IC50C D=22 75 E52-IC75C D=10 E52-IC75C D=12 E52-IC75C D=15 E52-IC75C D=22 100 E52-IC100C D=10 E52-IC100C D=12 E52-IC100C D=15 E52-IC100C D=22 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 14 E52 Enclosed-terminal Models (High-temperature Use) E52-PR@C Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. 98 Permissible Temperature in Dry Air Aluminum die-cast terminal box SUS304 Ceramic protective tubing (t2.0) D Element wire R 17 dia. 90 Bending of protective tubing: 6 mm max. 21.7 dia. 40 dia. 17 dia. 0qC to 1,400qC Terminal box: The permissible temperature is 0qC to 80qC. Note: The terminals in the cap indicate polarity (+ or ). Cap 57 100 L-150 G1/2, 15-A ground (with 11-inner-dia. rubber bushing built-in) Use wiring terminals that fit M4 screws. Model Information Element type Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 17 dia. Model R (See note 1.) Enclosed-ter- 50 minal Models 75 100 R (See note 2.) Enclosed-ter- 50 minal Models 75 100 Standard E52-PR50C D=17 PT1 E52-PR75C D=17 PT1 E52-PR100C D=17 PT1 E52-PR50C D=17 PT0 E52-PR75C D=17 PT0 E52-PR100C D=17 PT0 Protective tubing material Permissible temperature in dry air Note 1: JIS ceramic Cat.1 (PT1) Mullite, high alumina, etc. 1,500qC (See note.) Note 2: JIS special ceramic (PT0) Recrystallized alumina, fused alumina, etc. 1,700qC (See note.) Note: The permissible temperature given for the protective tubing is higher than 1,400qC, but the permissible temperature of the thermocouple element wire is only 1,400qC. Therefore, the protective tubing of the E52-PR@C can withstand high temperatures momentarily to the levels given in the table as exceptions, but the element wire will deteriorate quickly if the thermocouple is used regularly at temperatures that exceed the permissible temperature for the element wire. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 15 E52 Model Number Legend The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Thermocouples E52-@@@ D=@@@M@ 1 2 3 4 5 6 7 1. Element type CA: K IC: J PR: R 2. Protective tubing length (L) Specify the length in centimeters in the following range: Unit (cm) 4. Diameter Specify the protective tubing material according to the table. Code Diameter Protective tubing (D) construction Protective tubing material 1 1 mm Sheathed SUS316 1.6 1.6 mm Sheathed SUS316 E52-@@A (Exposed-lead Model) 3.2 3.2 mm Sheathed SUS316 Diameter (D) 4.8 4.8 mm Sheathed SUS316 6.4 mm Sheathed SUS316, Inconel Length (L) 1 2 to 200 6.4 1.6 3 to 500 8 8 mm Sheathed SUS316, Inconel 3.2 5 to 2,000 10 10 mm Standard SUS316, SUS310S 4.8 8 to 2,300 12 12 mm Standard SUS316, SUS310S 10 to 1,200 15 15 mm Standard SUS316, SUS310S 12 to 1,000 22 22 mm Standard SUS316, SUS310S 17 17 mm Standard PT1, PT0 6.4 8 E52-@@B and E52-@@C (except E52-PR@C) Diameter (D) Length (L) 3.2 11 to 2,000 4.8 14 to 2,300 6.4 16 to 1,200 8.0 18 to 1,000 10 21 to 126 12 24 to 126 15 29 to 156 22 39 to 206 E52-PR@C Diameter (D) 17 5. Heat resistance Specify this item for the exposed-lead models only. Code Temperature range Lead type --- 20qC to 70qC Sleeve: 0qC to 70qC Vinyl-covered NETU 0qC to 150qC Sleeve: 0qC to 100qC Glass-wool-covered with external shield 6. Lead length (M) Specify the length in meters in the following range for the E52@@A only. Range: 1 to 100 m 7. Protective tubing material Length (L) Code 50, 75, 100 3. Terminal A: Exposed lead wires (element type: K, J) B: Exposed terminals (element type: K, J) C: Enclosed terminals (element type: K, J, R) Note: Lead wires without crimped terminals (Y) are also available. Protective tubing material Element type --- SUS316 K, J Inconel Inconel K, D = 6.4 to 8 SUS310S SUS310S K, D = 10 to 22 PT1 JIS ceramic Cat.1 R PT0 JIS special ceramic R Examples Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-CA42A D=4.8 NETU 10M Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2 E52-IC36C D=3.2 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 16 E52 Low-cost Models Low-cost Platinum Resistance Thermometers Exposed-lead Models with Screws Specifications E52-P6D Element type Pt100 Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 30 mm Dimensions 4 dia. Tapered pipe thread Argon arc welding SUS304 R1/8 Silicone tubing SUS304 (t0.25) Caulking Black (B) Max. detectable temperature 250qC Temperature range 50qC to 250qC Lead wire 50qC to 150qC Fluororesin-covered wire with 1.0 outer dia. each (PFA) 7/0.18 Red (A) 14 65 Y-type crimp terminal for M4 M 30 10 6 15 Black (B) Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6D 1M 2 E52-P6D 2M 4 E52-P6D 4M Exposed-lead Models with Flange Specifications E52-P6F Element wire Pt100 Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 30 mm Dimensions Flange 120 SUS304 Three, 3.5 dia. 120 Silicone tubing Caulking SUS304 (t0.25) 4 dia. 50qC to 250qC Lead wire 50qC to 150qC Red (A) Black (B) Max. detectable temperature 250qC Temperature range Fluororesin-covered wire with 1.0 outer dia. each 1 20 dia. 30 dia. 65 Silver soldering Y-type crimp 30 terminal for M4 M 15 Black (B) Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6F 1M 2 E52-P6F 2M 4 E52-P6F 4M Exposed-lead Models Specifications E52-P10AE Element type Pt100 Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 20 mm Dimensions 3.2 0.1 dia. SUS304 (t0.25) Silicone shrinkable tubing White (B) Max. detectable temperature 250qC Temperature range 50qC to 250qC Lead wire 50qC to 150qC 30 100 Y-type crimp terminal for M4 M White (B) Note: 1. The protective tubing is of pipe construction, which must not be bent. 2. A Compression Fitting (PT@) cannot be used for mounting. Lead wire length (m) http://www.ia.omron.com/ Fluororesin-covered wire with 1.0 outer dia. each Caulking (PFA) 7/0.18 Red (A) Model 1 E52-P10AE 1M 2 E52-P10AE 2M 4 E52-P10AE 4M (c)Copyright OMRON Corporation 2007 All Rights Reserved. 17 E52 Low-cost Thermocouples Exposed-lead Models with Spring E52-CA@AS, E52-IC@AS Specifications Dimensions Element type K (CA), J (IC) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Non-grounded type Temperature range 0qC to 400qC: K (CA) 0qC to 350qC: J (IC) Lead wire 0qC to 180qC L SUS304 (t0.4) 4.8 dia. 32 12 dia. M 150 80 Red (+) Sleeve Brass-nickel Closely wound plating spring coil Fully glass-wool-covered compensating cable with four 0.65-dia. conductors and external dimensions of approx. 5.1 x 3.0 White (-) Y-type crimp terminal for M4 Color code (K: Blue, J: Yellow) L: Protective tubing length M: Lead wire length Note: The sleeve resists temperatures ranging between 0qC and 100qC. Note: The protective tubing is of pipe construction, which must not be bent. Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 65 100 150 200 1 E52-CA6AS 1M E52-IC6AS 1M 2 E52-CA6AS 2M E52-IC6AS 2M 4 E52-CA6AS 4M E52-IC6AS 4M 1 E52-CA10AS 1M E52-IC10AS 1M 2 E52-CA10AS 2M E52-IC10AS 2M 4 E52-CA10AS 4M E52-IC10AS 4M 1 E52-CA15AS 1M E52-IC15AS 1M 2 E52-CA15AS 2M E52-IC15AS 2M 4 E52-CA15AS 4M E52-IC15AS 4M 1 E52-CA20AS 1M E52-IC20AS 1M 2 E52-CA20AS 2M E52-IC20AS 2M 4 E52-CA20AS 4M E52-IC20AS 4M http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 18 E52 Exposed-lead Models with Screw E52-CA1D, E52-IC1D Specifications Dimensions Element type K (CA), J (IC) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Grounded type Temperature range 0qC to 400qC: K (CA) 0qC to 350qC: J (IC) Lead wire 0qC to 180qC 0.65-dia. 2.8 thermocouple element B 3.8 dia. Movable ring (brass) 1 10 A C M Color tubing Brass (K: Blue, J: Yellow) Cut a thread into the workpiece, and screw in the thermocouple while pushing in so that the tip makes complete contact. End Cut after silver soldering Red (+) Black (-) Color code 5 dia. (K: Blue, SUS304 Crimp terminal for M4 J: Yellow) screw Covered with black insulation tubing (W1/4) Enamel-bonded copper wire Fully glass-wool-covered cable with external shield and external dimensions of approx. 3.1 x 2.0 Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. Specify the type of screw (i.e., M6, M8, Internal Construction (E52-CA1D) 0.65-dia. or W1/4) when ordering. black wire Closely wound Movable ring 3. The thermocouple is not of airtight Brass enamel-bonded coil. construction. 4. OMRON recommends that the tip of the thermocouple is touching the sensing object. Installation Example 80 M6 Lead wire length (m) Screw M1/4 M6 M8 A (mm) 5 4 5.3 B (mm) 11.5 11 14 C (mm) 3 4 2.5 Brass pipe Screw Shielded glass-wool lead wire Workpiece Note: E52-CA1D with the same shape and multiple element wires are also available. Refer to page 27 for details. Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC) Model M6 screw M8 screw W1/4 screw 1 E52-CA1D M6 1M E52-IC1D M6 1M 2 E52-CA1D M6 2M E52-IC1D M6 2M 4 E52-CA1D M6 4M E52-IC1D M6 4M 1 E52-CA1D M8 1M E52-IC1D M8 1M 2 E52-CA1D M8 2M E52-IC1D M8 2M 4 E52-CA1D M8 4M E52-IC1D M8 4M 1 E52-CA1D W1/4 1M E52-IC1D W1/4 1M 2 E52-CA1D W1/4 2M E52-IC1D W1/4 2M 4 E52-CA1D W1/4 4M E52-IC1D W1/4 4M http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 19 E52 Exposed-lead Models with Flange Specifications E52-CA6F, E52-IC6F Element type K (CA), J (IC) Dimensions Element diameter 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Fully glass-wool-covered tubing with external dimensions of 3.6 x 2.2 Three, 3.5 dia. 120 120 SUS304 Silver soldering Silicone tubing Solder processed SUS304 K (CA) White/red stripe (+) White/blue stripe (-) Thermal contact Grounded type Temperature range 0qC to 350qC: K (CA) 0qC to 350qC: J (IC) Lead wire 0qC to 150qC Color code (K: Blue, J: Yellow) M 4 dia. 1 20 dia. 30 dia. 30 65 15 J (IC) White/red stripe (+) White/yellow stripe (-) 80 10 Lead wire length (M): 1, 2, or 4 m Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The tip is processed with solder, which ensures ease of welding. 3. The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA6F 1M E52-IC6F 1M 2 E52-CA6F 2M E52-IC6F 2M 4 E52-CA6F 4M E52-IC6F 4M Exposed-lead Models with Screws Specifications E52-CA6D, E52-IC6D Element type K (CA), J (IC) Dimensions Element diameter 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Tapered Fully glass-wool-covered pipe thread tubing with external Argon arc welding SUS304 dimensions of 3.6 x 2.2 Solder processed R1/8 SUS304 Silicone tubing K (CA) White/red stripe (+) White/blue stripe (-) Thermal contact Grounded type Temperature range Lead wire 0qC to 350qC: K (CA) 0qC to 350qC: J (IC) 0qC to 150qC 4 dia. 14 80 10 30 10 6 65 15 J (IC) White/red stripe (+) White/yellow stripe (-) M Color code (K: Blue, J: Yellow) Lead wire length (M): 1, 2, or 4 m Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The tip is processed with solder, which ensures ease of welding. 3. The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA6D 1M E52-IC6D 1M 2 E52-CA6D 2M E52-IC6D 2M 4 E52-CA6D 4M E52-IC6D 4M http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 20 E52 Exposed-lead Models Specifications E52-CA10AE, E52-IC10AE Element type K (CA), J (IC) Dimensions Element diameter 0.32 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 3.2 0.1 dia. SUS304 Caulking 2.8-max. outer-dia. fully glass-woolcovered tubing White/red stripe (+) White (-) 80 Thermal contact Non-grounded type Temperature range 0qC to 350qC: K (CA) 0qC to 200qC: J (IC) Lead wire 0qC to 180qC M 100 Color code (K: Blue, J: Yellow) Note: 1. 2. 3. 4. The thermocouple is a single wire from the tip to the terminal. Lead wire length M: 1, 2, or 4 m The protective tubing is of pipe construction, which must not be bent. The thermocouple cannot be mounted using a PT@ Compression Fitting. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA10AE 1M E52-IC10AE 1M 2 E52-CA10AE 2M E52-IC10AE 2M 4 E52-CA10AE 4M E52-IC10AE 4M Exclusive Models Thermocouples Thermocouples for Molding Machines Specifications E52-CA2GV, E52-IC2GV Element type K (CA), J (IC) Dimensions Element diameter 1.0 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 11-dia. spring metal fitting Closely wound spring coil Bayonet 4.8 dia. SUS304 6.8 dia. M3 screw Thermal contact Grounded type Temperature range 0qC to 350qC Lead wire 0qC to 180qC 25 15 22 105 Adapter (provided) 4.1-outer-dia. glass-wool-covered cable with external shield K (CA) White/red stripe (+) White/blue stripe (-) White stripe (-) Color code Y-type crimp (K: Blue, J: Yellow) terminal for M4 Element type: K (CA) 10 15 25 Element type: J (IC) Model 1 E52-CA2GV 1M E52-IC2GV 1M 2 E52-CA2GV 2M E52-IC2GV 2M http://www.ia.omron.com/ 12 dia. Brass-nickel plating M Lead wire length (M): 1 or 2 m Lead wire length (m) R1/8 J (IC) White/red stripe (+) (c)Copyright OMRON Corporation 2007 All Rights Reserved. 21 E52 Thermocouples with Crimp Terminals Specifications E52-CA1GT, E52-IC1GT Element type K (CA), J (IC) Dimensions Element diameter 0.65 mm (single wire) Class Class 2 (0.75) M4, round crimp terminal 6.5 Silicone tubing 4.2-max. outer-dia. glass-woolcovered cable with externally braided shield K (CA) J (IC) White/red stripe (+) White/red stripe (+) Thermal contact Grounded type Temperature range 0qC to 300qC Lead wire 0qC to 150qC Note: The E52-CA1GT is also available with double elements. Refer to page 23 for details. 4.4 dia. 15 White stripe (-) Color code (K: Blue, J: Yellow) 6 dia. max. Y-type crimp terminal for M4 M Lead wire length (M): 1 or 2 m Lead wire length (m) White/yellow stripe (-) 80 Element type: K (CA) Element type: J (IC) Model 1 E52-CA1GT 1M E52-IC1GT 1M 2 E52-CA1GT 2M E52-IC1GT 2M Platinum Resistance Thermometers Platinum Resistance Thermometers for Surface Temperature Measurement Specifications E52-P2GS Dimensions Element type Pt100 Class Class B Protective tubing material SUS304 With brass-nickel-plated bracket Conductor type 3-conductor system Temperature range 50qC to 250qC Lead wire 50qC to 150qC Silicone-covered 3-conductor cable Brass-nickel-plated bracket with twelve 0.18-dia. conductors (0.3-mm thick) Four, 3.2 dia. 6-dia. SUS304 and approx. 4.8 dia. sleeve Press Red (A) 20 14 5 White (B) 50 20 28 Silicone tubing M Approx. 32 Black (B) 80 Y-type crimp terminal for M4 Lead wire length (M): 1 or 2 m 6 1.5 Lead wire length (m) Model 1 E52-P2GS 1M 2 E52-P2GS 2M Platinum Resistance Thermometers for Room Temperature Measurement Specifications E52-P10GR Element type Pt100 Class Class B Protective tubing material SUS304 Conductor type 3-conductor system 15 Temperature range 50qC to 60qC Lead wire Dimensions 92 Aluminum alloy 6.7-outer-dia. vinylcovered 3-conductor cable 65 dia. (twenty 0.18-dia. conductors, 0.5 mm thick) SUS304 8 dia. Red (A) White (B) 78 20 dia. 20qC to 70qC Black (B) Y-type crimp terminal for M4 80 97 100 2,000 55 Brass-nickel-plated protective pipe Lead wire length (m) 2 http://www.ia.omron.com/ 7 dia. PF1/2 Model E52-P10GR 2M (c)Copyright OMRON Corporation 2007 All Rights Reserved. 22 E52 Double-element Platinum Resistance Thermometers Specifications E52-P20GW Element type Pt100 Class Class B Protective tubing material SUS304 Polyamide-insulated tubing with 0.5-dia. Ag lead wire Conductor type Double-element, 3conductor system Resistance thermometer element Temperature range 50qC to 250qC Lead wire 20qC to 70qC Dimensions Round press with hexagonal caulking Silicone shrinkable tubing M3.5, round crimp terminal Tubing with terminal number 8.2 dia. Red (A1) Black (B1) White (B1) 10 dia. 3.2 dia. Brown (A2) Filled with silicone Yellow (B2) Fluororesin tubing 200 Green (B2) M 70 Lead wire length (M): 1 or 2 m 80 Fully vinyl-covered lead cable with twenty 0.18-dia. conductors (0.5 mm thick) Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P20GW 1M 2 E52-P20GW 2M Waterproof Platinum Resistance Thermometers Specifications E52-P10GP Dimensions Element wire Pt100 Class Class B Protective tubing material SUS304 Conductor type 3-conductor system Temperature range 0qC to 70qC (underwater) 20qC to 70qC (in the air) Lead wire 0qC to 70qC Resistive pressure Y-type crimp 7.6-outer-dia. vinyl-covered 3-conductor cable (thirty 0.18-dia. terminal for M4 conductors, 0.75 mm thick) Red (A) 20 dia. 7 dia. White (B) Black (B) 100 2 10 kg/cm max. 62 5 M Lead wire length (M): 2 or 4 m Note: The lead wires are vinyl-covered, and cannot be used underwater. Use the E52-P5A-40 if waterproof lead wires are required for use underwater. Refer to page 24 for details. Lead wire length (m) http://www.ia.omron.com/ Model 2 E52-P10GP 2M 4 E52-P10GP 4M (c)Copyright OMRON Corporation 2007 All Rights Reserved. 23 E52 Corrosion-resistant Models with Fluororesin-covered Protective Tubing Thermocouples Exposed-lead Models Specifications E52-CA20A-1 Element type K (CA) Class Class 2 (0.75) Protective tubing material SUS316 with Fluororesin-covered (FEP) tube Thermal contact Non-grounded type Temperature range 0qC to 180qC Lead wire Vinyl-covered: 20qC to 70qC Dimensions Y-type crimp Araldite resin terminal for M4 Compensating conductor Red (+) Fixed with adhesive tape and silicone heat-shrinking tube d Sleeve Sheath D White (-) FEP-covered tubing 2,000 Model 200 40 Protective tubing diameter Sleeve diameter (mm) Covering thickness (mm) Lead wire length (m) E52-CA20A-1 D=4.6 2M D = 4.6 d=7 0.7 2 E52-CA20A-1 D=6 2M D = 6.0 d=7 0.6 2 E52-CA20A-1 D=8 2M D = 8.0 d = 10 0.8 2 Platinum Measurement Exposed-lead Models Specifications E52-P20A-1 Element type Pt100 Class Class B Protective tubing material SUS316 with Fluororesin-covered (FEP) tube Conductor type 3-conductor system Temperature range 80qC to 180qC Lead wire Vinyl-covered: 20qC to 70qC Dimensions Y-type crimp terminal for M4 Araldite resin Fixed with adhesive tape and silicone heat-shrinking tube d Sleeve Lead wires Red (A) Sheath D White (B) Black (B) FEP-covered tubing 2,000 Model 200 60 Protective tubing diameter Sleeve diameter (mm) Coating thickness (mm) Lead wire length (m) E52-P20A-1 D=4.6 2M D = 4.6 d=8 0.7 2 E52-P20A-1 D=6 2M D = 6.0 d=8 0.6 2 E52-P20A-1 D=8 2M D = 8.0 d=8 0.8 2 FEP-molded Models (Completely Waterproof) Specifications E52-P5A-40 Element type Pt100 Class Class B Protective tubing material Fluororesin-molded (FEP) covering Conductor type 3-conductor system Temperature range 50qC to 180qC Lead wire Fluororesin-covered (PFA): 50qC to 180qC Dimensions FEP mold 7 dia. Red (A) White (B) 10 7 3 White (B) 40 Y-type crimp terminal for M4 65 M Model http://www.ia.omron.com/ PFA-covered wire 7/0.18 Protective tubing diameter Lead wire length (m) E52-P5A-40 2M D = 10 (elliptical) 2 E52-P5A-40 4M D = 10 (elliptical) 4 E52-P5A-40 6M D = 10 (elliptical) 6 E52-P5A-40 8M D = 10 (elliptical) 8 (c)Copyright OMRON Corporation 2007 All Rights Reserved. 24 E52 Pressure-resistant Explosion-proof (d2G4) Models Thermocouples Enclosed-terminal Models Specifications E52-CA@@C-6 Element type K (CA) Class Class 2 (0.75) Protective tubing material L2 section: SUS316 L1 section: SUS304 Operating temperature range (in dry air) Sensor: 100qC to 900qC Terminal: 0qC to 70qC Dimensions L Metal conduit connected with screws to terminal box Conduit thread PF1/2 Installation method Conforms to Technical Recommendations of the Research Institute of Industrial Safety (Japan) Hexagonal slot, 22 between flats L1 SUS316 15 dia. 6.4 dia. 84 dia. Explosion- Construction Pressure-resistant proof explosion-proof structure specifica- Explosiond2G4 tions protected class and ignitability Lead wire wiring method 115 L2 SUS304 18 77 Model PF1/2 Protective tubing length L (cm) Protective tubing diameter L2 (mm) E52-CA20C-6 D=6.4 L2=150 20 D = 6.4 150 E52-CA35C-6 D=6.4 L2=300 35 D = 6.4 300 E52-CA50C-6 D=6.4 L2=450 50 D = 6.4 450 E52-CA75C-6 D=6.4 L2=700 75 D = 6.4 700 Platinum Resistance Thermometers for Surface Temperature Measurement Enclosed-terminal Models Specifications E52-P@@C-6 Element type Pt100 Class Class B Protective tubing material L2 section: SUS316 L1 section: SUS304 Operating temperature range (in dry air) Sensor: 100qC to 500qC Terminal: 0qC to 70qC Explosion- Construction Pressure-resistant proof explosion-proof structure specifica- Explosiond2G4 tions protected class and ignitability Lead wire wiring method Metal conduit connected with screws to terminal box Conduit thread PF1/2 Installation method Conforms to Technical Recommendations of the Research Institute of Industrial Safety (Japan) http://www.ia.omron.com/ Dimensions L 115 L2 Hexagonal slot, 22 between flats L1 SUS316 15 dia. 6.4 dia. 84 dia. SUS304 18 77 Model Protective tubing length L (cm) PF1/2 Protective tubing diameter L2 (mm) E52-P20C-6 D=6.4 L2=150 20 D = 6.4 150 E52-P35C-6 D=6.4 L2=300 35 D = 6.4 300 E52-P50C-6 D=6.4 L2=450 50 D = 6.4 450 E52-P75C-6 D=6.4 L2=700 75 D = 6.4 700 (c)Copyright OMRON Corporation 2007 All Rights Reserved. 25 E52 Double-element Models Thermocouple Exposed-lead Models Specifications E52-CA20A-7 Element type K (CA) Class Class 2 (0.75) Protective tubing material SUS316 (with sheath) Thermal contact Non-grounded type Temperature range 0qC to permissible temperature limit Lead wire Vinyl-covered: 20qC to 70qC Dimensions Compensating conductor Red (+) d Sleeve Protective tubing D White (-) Red (+) White (-) 80 2,000 200 45 Permissible Temperature in Dry Air D Element wire K (CA) SUS316 3.2 dia. 750qC 4.8 dia. 850qC 6.4 dia. 850qC 8.0 dia. 900qC Model Protective tubing diameter Sleeve diameter (mm) Permissible Lead wire Temperature length (m) (qC) E52-CA20A-7 D=3.2 2M D = 3.2 d = 10 750 2 E52-CA20A-7 D=4.8 2M D = 4.8 d = 10 800 2 E52-CA20A-7 D=6.4 2M D = 6.4 d = 10 800 2 E52-CA20A-7 D=8.0 2M D = 8.0 d = 10 900 2 Platinum Resistance Thermometers Exposed-lead Models Specifications E52-P20A-7 Element type Pt100 Class Class B Protective tubing material SUS316 (with sheath) Conductor type 3-conductor system Black (B1) Temperature range 200qC to 450qC White (B1) Lead wire Vinyl-covered: 20qC to 70qC Yellow (B2) Dimensions Y-type crimp terminal for M4 Red (A1) Lead wires Caulking Protective tubing (SUS316) D Brown (A2) Araldite resin Green (B2) 80 Model http://www.ia.omron.com/ Sleeve (SUS304) 2,000 70 200 Protective tubing diameter Lead wire length (m) E52-P20A-7 D=4.8 2M D = 4.8 2 E52-P20A-7 D=6.4 2M D = 6.4 2 (c)Copyright OMRON Corporation 2007 All Rights Reserved. 26 E52 Enclosed-terminal Models Specifications E52-P20C-7 Element type Pt100 Class Class B Protective tubing material SUS316 (with sheath) Conductor type 3-conductor system Temperature range 200qC to 450qC Dimensions 98 40 dia. 80 dia. Terminal box Protective tubing D 57 150 Model Protective tubing Protective length L (cm)) tubing diameter E52-P20C-7 D=4.8 20 D = 4.8 E52-P20C-7 D=6.4 20 D = 6.4 Models with Silicone-covered Lead Wires for Movable Parts Thermocouples Exposed-lead Models with Screws Specifications E52-CA1D-40 Element type K (CA) Class Class 2 (0.75) Screw material SUS304 Thermal contact Grounded type Temperature range 0qC to 300qC Lead wire Silicone-covered (0.1/30): 0qC to 150qC Dimensions 1 2.8 10 4.2 M 13 80 Silicone covering 80 Red (+) 11 3.8 dia. 8 dia. Caulking Thermocouple SUS304 screw element wire Movable ring Model White (-) SUS304 Silicone spring with covering Crimp terminal 6.5 outer dia. for M4 and 5.2 Silicone inside dia. shrinkable tubing Screw pitch Lead wire length (m) E52-CA1D-40 M6 1M M6 1 E52-CA1D-40 M6 2M M6 2 E52-CA1D-40 M6 4M M6 4 Thermocouples with Crimp Terminals Specifications E52-CA1GT-14 Element type K (CA) Dimensions Class Class 2 (0.75) Thermal contact Grounded type Temperature range 0qC to 350qC Silicone-covered M4, round, compensating cable with crimp terminal thirty 0.1-dia. conductors and external dimensions 6.5 of 3.5 x 4.9 Lead wire Silicone-covered (0.1/30): 0qC to 150qC Color tubing Blue CA (K) Red (+) White (-) 15 30 80 M Crimp terminal for M4 Lead wire length (M): 1 or 2 m Model http://www.ia.omron.com/ Lead wire length (m) E52-CA1GT-14 1M 1 E52-CA1GT-14 2M 2 (c)Copyright OMRON Corporation 2007 All Rights Reserved. 27 E52 Thermistors Element Interchangeable Thermistor for E5CS and E5C2 Temperature Ranges Temperature range Color code Nominal resistance Thermistor constant 50qC to 50qC Blue 6 k: (0qC) 3390K 0qC to 100qC Black 6 k: (0qC) 3390K 50qC to 150qC Red 30 k: (0qC) 3450K 100qC to 200qC Yellow 0.55 k: (200qC) 4300K 150qC to 300qC Green 4 k: (200qC) 5133K Lead wire A pair of 0.12 dia. 7 Fluororesin-insulated stranded wires with 0.86 outer dia. each Flat glass-wool-shielded lead cable with 0.12 dia. 10 conductors and external dimensions of 2.5 u 1.55 Specifications Item E52-THE@@ Coupling method Element interchangeable thermistor Class JIS class 1 Protective tubing material SUS304 Time constant 8 to 15 s in still water Dissipation factor 2.4 to 2.8 mW/qC in still air Lead wire heat resistive temperature 180qC Error Detectable temperature Error 50qC to 100qC r1qC max. 100qC to 350qC r1% max. of detectable temperature Permissible Temperature Detectable temperature Operating temperature 50qC to 50qC 100qC 0qC to 100qC 150qC 50qC to 150qC 200qC 100qC to 200qC 250qC 150qC to 300qC 350qC Note: Models with non-standard lead wire length and protective tubing length are available on request. This Thermistor is a dedicated Thermistor for the E5C2 and E5CS. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 28 E52 Exposed-lead Models E52-THE5A Temperature range Dimensions 50qC to 50qC SUS304 t0.25 Lead wires (See note.) Color code 4 dia. 15 50 50 10 Model E52-THE5A 50-50qC 1M 0qC to 100qC E52-THE5A 0-100qC 1M 50qC to 150qC E52-THE5A 50-150qC 1M 100qC to 200qC E52-THE5A 100-200qC 1M 150qC to 300qC E52-THE5A 150-300qC 1M 1,030 Note: The lead wires have no polarity Exposed-lead Models with Screws E52-THE6D Temperature range Dimensions Tapered pipe thread SUS304 Lead wires R1/8 (See note.) SUS304 t0.25 Color code 4 dia. Argon arc welding 15 10 6 14 65 15 Model 50qC to 50qC E52-THE6D 50-50qC 1M 0qC to 100qC E52-THE6D 0-100qC 1M 50qC to 150qC E52-THE6D 50-150qC 1M 100qC to 200qC E52-THE6D 100-200qC 1M 150qC to 300qC E52-THE6D 150-300qC 1M 50 10 1,000 Note: The lead wires have no polarity Exposed-lead Models with Flange E52-THE6F Temperature range Dimensions Three, 3.5 dia. 120 SUS304 SUS304 t0.25 120 Silver soldering Lead wires (See note.) Color code 4 dia. 15 1 20 dia. 30 dia. 65 15 Model 50qC to 50qC E52-THE6F 50-50qC 1M 0qC to 100qC E52-THE6F 0-100qC 1M 50qC to 150qC E52-THE6F 50-150qC 1M 100qC to 200qC E52-THE6F 100-200qC 1M 150qC to 300qC E52-THE6F 150-300qC 1M 50 10 1,000 Note: The lead wires have no polarity Note: 1. The Thermistor lead cable can be extended with a standard lead wire for extension. If waterproof performance is required, be sure that the lead cable joint is of waterproof construction as well. 2. Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the temperature range. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 29 E52 Accessories Compression Fittings Model Information Model Screw of part Applicable a protective tubing diameter PT 1/8 D=1.0 R 1/8 Dimension b 1.0 dia. PT 1/8 D=1.6 1.6 dia. PT 1/8 D=3.2 3.2 dia. PT 1/8 D=4.8 c d Flat diameter Part c Part b 5 13 10 14 14 5 15 12 17 14 4.8 dia. PT 1/4 D=3.2 R 1/4 3.2 dia. PT 1/4 D=4.8 4.8 dia. PT 1/4 D=6.4 6.4 dia. PT 3/8 D=8 R 3/8 8 dia. 5 19 15 21 17 PT 1/2 D=10 R 1/2 10 dia. 8 23.5 19.5 26 21 M 12 D=4.8 M 12 4.8 dia. 5 15 12 17 14 Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. The compression fitting is a screw that adjusts and secures the insertion length of Temperature Sensors with the above protective tubing diameters. The material of the Compression Fitting is SUS304 with internal fixing beads made of brass. a Protective tubing dia. D Sensor side Head side d c b Tighten using the retaining screw to secure to the protective tubing. Material Main body SUS304 Lock bead Brass Retaining screw SUS304 Source: JIS B 0203 (Unit: mm) Nominal thread size T.P.I. Outer (No. of diamethreads ter: d /inch) Effective diameter: d2 Root diameter: d1 Standard diameter position a (from pipe end) Minimum effective screw length: f PT 1/8 28 9.728 9.147 8.566 3.97 r0.91 2.5 PT 1/4 19 13.157 12.301 11.445 6.01 r1.34 3.7 PT 3/8 19 16.662 15.806 14.950 6.35 r1.34 3.7 PT 1/2 14 20.955 19.793 18.631 8.16 r1.81 5.0 a f Tapered thread d d2 d1 Standard dia. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 30 E52 Loose Flanges Model Information Applicable protective tubing diameter MF-1 Model 3.2 dia. MF-1 D=3.2 4.8 dia. MF-1 D=4.8 6.4 dia. MF-1 D=6.4 8 dia. MF-1 D=8 10 dia. MF-2 D=10 12 dia. MF-2 D=12 15 dia. MF-2 D=15 22 dia. MF-2 D=22 Note: 1. Use the Loose Flange in atmospheric pressure. The Loose Flange is not of airtight construction. 2. Use the Loose Flange at 400qC maximum. 3. Do not apply the Loose Flange to protective tubing diameters other than the applicable ones. MF-2 120 120 Three, 5 dia. Three, 6.5 dia. 36 54 dia. 21 dia. D dia. M4 31 dia. D dia. 5 14 24 23 dia. 45 dia. M6 6.6 35 dia. 70 dia. Material: Aluminum http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 31 E52 Compensating Conductors The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between 20qC and 70qC and two types of heat-resistive models for a temperature range between 0qC and 150qC are available. Be sure to use the compensating conductor for the extension of the length of the thermocouple. Model Information Thermocouple R K (CA) J (IC) Heat resistance Exterior Model (Length) 1m 2m 4m 8m Standard Fully vinyl-covered (waterproof) WPRG 1M WPRG 2M WPRG 4M WPRG 8M Heat resistive Fully glass-wool-covered WPRH 1M WPRH 2M WPRH 4M WPRH 8M Fully glass-wool-covered with external shield WPRH6 1M WPRH6 2M WPRH6 4M WPRH6 8M Standard Fully vinyl-covered (waterproof) WCAG 1M WCAG 2M WCAG 4M WCAG 8M Heat resistive Fully glass-wool-covered WCAH 1M WCAH 2M WCAH 4M WCAH 8M Fully glass-wool-covered with external shield WCAH6 1M WCAH6 2M WCAH6 4M WCAH6 8M Silicone-covered (See note 2.) WCAG-40 1M WCAG-40 2M WCAG-40 4M WCAG-40 8M Standard Vinyl covered (waterproof) WICG 1M WICG 2M WICG 4M WICG 8M Heat resistive Fully glass-wool-covered WICH 1M WICH 2M WICH 4M WICH 8M Fully glass-wool-covered with external shield WICH6 1M WICH6 2M WICH6 4M WICH6 8M Note: 1. Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above 100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details. 2. The WCAG-40 is suitable for moving parts. It has the same waterproof characteristics as the standard model (fully vinyl-covered) and can be used at high temperatures. Specifications (JIS C1610-1981) Model WPRG Type of thermocouple R WPRH Use Code Standard K (CA) WCAH WICG 4/0.65 0 to 70 Heat resis- RX-H tive Fully glass-woolcovered 7/0.3 0 to 150 WICH WICH6 Error (qC) +3/7 Exterior color Black Resistance of both lines (:/m) 0.055 0.140 RX-H6 Fully glass-woolcovered with external shield VX-G Fully vinyl-covered (waterproof) 4/0.65 20 to 70 r2.5 Heat resis- WX-H tive Fully glass-woolcovered 7/0.3 0 to 150 r3.0 1.07 4.18 Standard WX-H6 J (IC) Operating temperature range (qC) Fully vinyl-covered (waterproof) WCAH6 WCAG-40 Number of wires/wire diameter RX-G WPRH6 WCAG Exterior 0.39 Fully glass-woolcovered with external shield Heat resis- KX-G tive for moving parts Silicone-covered 30/0.1 20 to 150 r2.5 Standard JX-G Fully vinyl-covered (waterproof) 4/0.65 20 to 70 r2.5 Heat resis- JX-H tive Fully glass-woolcovered 7/0.3 0 to 150 JX-H6 Blue Yellow 0.47 1.27 Fully glass-woolcovered with external shield ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 32 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety. 2007. 3 OMRON Corporation In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.