BUSSMANN SERIES Compact Circuit Protector Industry's smallest fused disconnect offers superior circuit protection Delivers up to 200 kA SCCR in a compact, finger-safe design. Product description: Features and benefits: Eaton's revolutionary BussmannTM series Compact Circuit Protector (CCP) is designed as a fused branch circuit rated disconnect with a footprint 2/3 the space required by a traditional fusible switch. * With just 2/3 the space required by a traditional fusible switch, the CCP saves panel space. * 200 kA SCCR with Bussmann series Low-PeakTM CUBEFuse and Class CC fuses helps provide high equipment SCCR. Available in both Class CC and Bussmann series CF CUBEFuseTM versions, the CCP features high 200 kA Short-Circuit Current Rating (SCCR) at 600 V that can help increase equipment SCCR. These high ratings and compact design make the CCP ideal for industrial control panels, machinery and HVAC applications. * UL(R) 98 Listed, horsepower rated fused disconnect.* * Built-in switch/fuse interlock helps prevent fuse removal while energized. * Standard open fuse indication speeds troubleshooting. * No tools required for mounting onto DIN-Rail. * Available in 1-, 2- and 3-pole versions. * Class CC and CF versions with time-delay fuses. 3-pole CUBEFuse version The Bussmann series CUBEFuse has a small footprint and a high level of protection with ratings up to 100 A, 600 Vac and a 200 kA SCCR. Features for CCP CC, midget and 10x38mm versions Agency information: Wire range: Flammability rating: * * * * * UL Class CC fuse version * UL 98 Listed, File E302370, Guide WHTY * cULus to CSA(R) Standard 22.2 No. 4-04, File 302370, Guide WHTY7 * RoHS compliant * CE compliant UL midget fuse version * UL 508 Listed * cULus Certified 22.2 No. 14-05 * CE Compliant * RoHS compliant 10x38 IEC(R) Class aM and gG/gl fuse version * IEC 60947-3 AC23A * IEC 60947-3 DC23A * CE Compliant * RoHS compliant 18-6AWG single or dual rated (same size wire), solid or stranded 4AWG single, 75C Cu only Torque rating: * * * * Yes Local indication: 18-10AWG 20lb-In 8-4AWG 35lb-In * Yes Mounting: Poles: * UL 94V0 Padlockable: * 1-, 2- and 3-pole: AC version 1-pole: DC version DIN-Rail Construction * Finger-safe, IP20 compliant with 10AWG or larger wire Operating temperature: * -20C to 75C* * For fuse performance under or above 25C, consult fuse performance charts in Eaton's Bussmann series Selecting Protective Devices (SPD) handbook (Number 3002). Ratings 1-, 2-, and 3-pole Class CC and midget CCP Amp rating Fuse Class 30 CC 30 Number of poles 1-pole Class 80 Vdc CCP Max horsepower rating Volts SCCR 120 Vac 240 Vac 480 Vac 600 Vac 1 600Vac 200kA 0.5 -- -- CC 2 600Vac 200kA -- 2 30 CC 3 600Vac 200kA -- 30 UL midget 240Vac 10kA -- 32* 10x38 IEC 30 UL midget 32* 10x38 IEC 30 UL midget 32* 10x38 IEC 30 CC 30 CC 32* 10x38 IEC 1 2 3 Part number Agency information -- CCP-1-30CC UL 98 Listed, cULus 22.2, No. 4-04 -- -- CCP-2-30CC UL 98 Listed, cULus 22.2, No. 4-04 3 5 7.5 CCP-3-30CC UL 98 Listed, cULus 22.2, No. 4-04 -- -- -- 400Vac 120kA 240Vac 10kA -- 400Vac 120kA 240Vac 10kA -- -- -- -- -- -- -- Wire size/ (torque) Single/dual 8-6AWG sol/ str Single 4AWG sol/ str Fork terminal Wire type CCP-1-30M 75C Cu or higher IEC 60947-3, AC-23A CCP-2-30M CCP-3-30M 400Vac 120kA 80Vdc 20kA -- -- -- -- CCP-1-DCC 1 80Vdc 10kA -- -- -- -- CCP-1-DCM SCCR may be lower, refer to installed fuse data sheets. Fork terminal with a 4.3mm gap for a #8-32 stud, 30A max, insulated flange, wire size 12-10AWG. - 18-10AWG; 20 lb-In - 8-4AWG; 35 lb-In Recomended fuse types DC voltage Class CC Midget Class CC Midget LP-CC KTK LP-CC KLM KTK-R FNM FNQ BAF UL 508 Listed, cULus 22.2, No. 14-05 IEC 60947-3, AC-23A * 32A Class aM, 25A Class gG. AC voltage UL 508 Listed, cULus 22.2, No. 14-05 IEC 60947-3, AC-23A 1 UL 508 Listed, cULus 22.2, No. 14-05 10X38 IEC Part number IEC Class family C10G gG/gL C11M aM UL 98 Listed, CSA 22.2, No. 4-04 UL 508 Listed, cULus 22.2, No. 14-05 IEC 60947-3, DC-23A Features for CCP_CF CUBEFuse version Agency information: * * * * Wire range (75C Cu or higher): UL 98 Listed, File E302370, Guide WHTY cULus to CSA Standard 22.2 No. 4-04, File 302370, Guide WHTY7 RoHS compliant CE compliant * * Ampacity rejection: * CCP_CF disconnects will not accept CUBEFuse amp ratings greater than the switch rating. * Finger-safe, IP20 compliant with 10AWG or larger wire. * * * 30 A 60 A 100 A 1-, 2- and 3-pole Operating temperature: * -20C to 75C* Flammability rating: * UL 94V0 Padlockable: * Yes Local indication: 30-60A 18-10AWG, 20 lb-in * 8-6AWG, 35 lb-in * 4AWG, 35 lb-in 100A * 8-10AWG, 25 lb-in * 8-1AWG, 35 lb-in * 6AWG, 45 lb-in * * Amp ratings: * * Torque: Construction: * Poles: 30-60A * 18-6AWG, single/dual, solid/ stranded * 4AWG, single/solid/stranded 100A * 8-10AWG, single, solid/stranded * 8-1AWG, single, stranded * 6AWG, dual, stranded Yes Mounting: * DIN-Rail * For fuse performance under or above 25C, consult fuse performance charts in Eaton's Bussmann series Selecting Protective Devices (SDP) handbook (Number 3002). 1- and 2-pole 30A 3-pole 60A Ratings Amp rating UL fuse Class Number of poles 30 CF 1 30 CF 2 30 CF 3 Max horsepower rating* Volts SCCR 600Vac 200kA 125Vdc 100kA 600Vac 200kA 125Vdc 100kA 600Vac 200kA 600Vac 200kA 125Vdc 100kA 600Vac 200kA 125Vdc 100kA Wire size (See note for torque) 120 Vac 240 Vac 480 Vac 600 Vac 1.5 -- -- -- -- 3 -- -- -- 5 15 10 3 -- -- -- Single 4AWG sol/str -- 7.5 -- -- Fork terminal** 60 CF 1 60 CF 2 60 CF 3 600Vac 200kA -- 7.5 20 10 100kA 200kA 5 -- -- -- 100 CF 1 125Vac 600Vac 100 CF 2 125Vac 600Vac 100kA 200kA -- 10 -- -- 100 CF 3 600Vac 200kA -- 20 50 50 Wire type Single/dual 18-6AWG sol/str 75C Cu or higher Single 8-10AWG sol/str 8-1AWG str Part number Agency information CCP-1-30CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-2-30CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-3-30CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-1-60CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-2-60CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-3-60CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-1-100CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-2-100CF UL 98 Listed, cULus 22.2, No. 4-04 Dual 6AWG str * With time-delay Low-Peak CUBEFuse. ** Fork terminal with a 4.3mm gap for a #8-32 stud, 30A max, insulated flange, wire size 12-10AWG. Fork terminal** CCP-3-100CF UL 98 Listed, cULus 22.2, No. 4-04 30-60A: - 18-10AWG 20 lb-In - 8-6AWG 35 lb-In - 4AWG 35 lb-In 70-100A: - 8-10AWG single 25 lb-In - 8-1AWG single 35 lb-In - 6AWG dual 45 lb-In Accesories Auxiliary contact Remote fuse monitoring NO+NC contact output to indicate the status of the switching mechanism on the Bussmann series CCP. A resetable three-phase fuse monitor that integrates with the I/O card in a Programmable Logic Controller (PLC). When the fuse opens, the output signal is sent high and will remain high until the unit is reset. Agency information: Agency information: * * * UL 98 File E155130, guide WHTY2 cULus to CSA Standard 22.2 Number 4-04 IEC 60947-5-1 Specifications: * * * * * * Power input 24 Vdc / 10mA max Output signals * Digital 0 Vdc (low), 24Vdc (high) * 0Vdc low - fuse is good * 24Vdc high - fuse has opened * CCP-PLC-IND (Includes fork terminals) CCP-AUX accessories Max per CCP Auxiliary contacts 1 per CCP NO+NC for switch (1-, 2- or status up to 60A 3-pole) Auxiliary contacts 1 per CCP NO+NC for switch (1-, 2- or status 70 to 100A 3-pole) Flammability rating UL 94V0 * CCP-AUX Description * * * Rated impulse voltage 8kA Local indication * Two distinct LEDs indicate unit power (green) and open fuse (red). Upon the replacement of the fuse, the actuation of the reset switch will reset the open fuse LED. * Specifications: * Rated ampacity * 5A Rated voltage * 240 Vac NC/NO contacts are closed/open when the CCP switch is in the "ON" position (closed) Flammability rating * UL 94V0 UL 98 File E155130, guide WHTY2 cULus to CSA Standard 22.2 Number 4-04 PLC fuse monitor Signal output Agency information 5A/240VAC UL 98 Recognized, cURus 22.2 No. 4-04, IEC 60947-5-1 AC-15 5A/240Vac UL 98 Recognized, CSA C22.2 No. 4-04 Catalog number Description Wired remote fuse indication for PLC applications up to 60A CCP-AUX CCP-AUX-100 De-energize all circuits before installing or removing any CCP-AUX devices and follow all prescribed safety procedures. Wired remote fuse indication for PLC applications 70 to 100A Max per CCP Signal output to PLC Min. circuit volts Agency information Catalog number UL 98 Recognized, 1 per CCP (1, 2- or 3-Pole) cURus 22.2 No. 4-04 24Vdc/ 10mA CCP-PLC-IND 100Vac UL 98 Recognized, CSA C22.2 No. 4-04 CCP-PLC-100 De-energize all circuits before installing or removing any CCP-PLC-IND devices and follow all prescribed safety procedures. See data sheet No. 1157 for more information. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries (c) 2017 Eaton All Rights Reserved Printed in USA Publication No. 3191 June 2017 Eaton, Bussmann, CUBEFuse and Low-Peak are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group. IEC is a registered trademark of the International Electrotechnical Commission. UL is a registered trademark of the Underwriters Laboratories, Inc. For Eaton's Bussmann series product information, call 1-855-287-7626 or visit: Eaton.com/bussmannseries Follow us on social media to get the latest product and support information.