15WAC-DC Reliable Industrial Adaptor GS15A series
SPECIFICATION
GS15A-1P1J
GS15A-11P1J
GS15A-2P1J GS15A-3P1J GS15A-4P1J GS15A-5P1J GS15A-6P1J GS15A-8P1J
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
PROTECTION
5V 7.5V 9V 12V 15V 18V 24V 48V
GS15A-1
GS15A-1-1
GS15A-2 GS15A-3 GS15A-4 GS15A-5 GS15A-6 GS15A-8
2.40A 1.60A 1.66A 1.25A 1.00A 0.83A 0.625A 0.31A
0 ~ 2.40A 0 ~ 1.60A 0 ~1.66A 0 ~ 1.25A 0 ~ 1.00A 0 ~ 0.83A 0 ~ 0.625A 0 ~ 0.31A
12W 12W 15W 15W 15W 15W 15W 15W
50mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0%
±5.0%
±5.0%
±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±3.0%
±3.0%
±3.0%
±2.0% ±2.0%
±2.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0%
3000ms, 50ms, 16ms at full load
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
80% 82.5% 85% 85% 85% 85% 85.5% 87%
0.5A / 100VAC
Cold start 30A/ 115VAC 50A / 230VAC
0.25mA / 240VAC
UL60950-1, CSA C22.2, TUV EN60950-1, approved
EAC TP TC 004
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
500Khrs min. MIL-HDBK-217F(25 )℃
0 ~ +50 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
100*58.5*32.8mm (L*W*H)
190g ; 90pcs / 18Kg / CARTON
CONNECTOR
PLUG
CABLE
See page 4~5 ; Other type available by customer requested
See page 4~5 ; Other type available by customer requested
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor. μμ
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load.
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
OVERLOAD
OVER VOLTAGE
105 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
>120% rated output voltage
Protection type : Clamp by zener diode
Compliance to EN55022 Class B, EN61000-3-2,3
SAFETY &
EMC
(Note. 7)
EMC IMMUNITY
EMC EMISSION
Parameter Standard
EN55032(CISPR32)FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
EN55032(CISPR32)FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
EN61000-3-2
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11 >.95% dip 0 5 periods, 30% dip 25 periods,
95% interruptions 250 periods>
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
EFT bursts
Surge susceptibility
Level 3, 8KV air; Level 2, 4KV contact
Conducted susceptibility
Level 2, 3V/m
Level 3, 1KV/L-N 2KV/L,N-PE
Level 1, 1A/m
Level 2, 3V
Level 2, 1KV
RF field
susceptibility
Magnetic field
immunity
Voltage dips , interruption
File Name:GS15A-SPEC 2018-01-15