A NEW BREED OF COMPACT DRIVE
Your partner in automation systems
E500 SERIES
PRODUCT
FROM MITSUBISHI
and go
faster
that’s
to set up
Plug in for instant
compatibility
no other compact drive
works faster
The exciting and special
feature of the E500 is its
‘built-in’ communications.
This drive is one of the first in
the market place to have the
capability to connect to any of
3 open fieldbuses (DeviceNet,
Profibus DP
and
CC-Link) simply by
fitting a plug-in option card. With a 19200 Kbaud
RS 485 serial comms capability as standard,
this allows simple and fast connectivity
to other manufacturers’ equipment in
existing plants.
Connectivity is made even simpler
using Mx500 software. This is Windows-
based software which enables communication
and control between any Mitsubishi 500 Series
inverter, from
setting parameters automatically to
diagnostics functions.
a big appetite for hard work
However, don’t be fooled by the small size – these drives can
tackle the most demanding work load. The flexible, versatile and
communication capabilities of the E500 range offer greater speed
of set up, greater control, and the ability to easily integrate into a huge range of applications – from food to
pharmaceuticals, elevators to HVAC.
Yet again Mitsubishi Electric has produced
a thoroughbred drive with unrivalled performance.
It is not just the functionality of the E500 range that
is amazing, it’s also the way Mitsubishi has packed
it all into such small frame-sizes. Quite simply, this new
breed of compact drives brings you more benefits than ever before.
E500 is set to be a
winner in its class
packed out wi
t
EMC
Compliance
Harmonics
environmentally friendly
Low
Operational
Noise
Optional DC Choke
Soft PWM
Cassette Filter
Internal on 200V Version
Regenerative Overvoltage
Protection
Fan Breakdown
Drive Temperature
EEPROM Parameters Fault
Inrush Suppression
High Response Current Limit
powerful protection
External Thermal Relay
Internal Motor Overcurrent
Output Ground Fault
Constant Speed
Acceleration
Deceleration Stall Prevention (150%)
Zero Current Detection
High Response
Current Limit
Process
Protection
Drive
Motor
Operational
Control
Configurable
high functionality
Programmable I/O
15 Preset Speeds
can be DC fed from
Common DC Bus
Coasting Motor
Restart
0-10V Analogue
Output
PID Control
Digital Pot Control
Analogue Speed
Setting Input
15 Preset Speeds
easy to integrate
RS485
CC Link
Profibus
DeviceNet
Sink or Source Logic
t
h functionality
integrated product range Compatible with A500 Series
High Power Factor Converter
Brake Unit
200 & 400V Versions
Dual Torque Rating
Easy
Commissioning
Easy to Install
Easy to Use
easy to use
Multiple User Group
Parameter Selection
Integrated Operator
Display
Simple Cabling
Inrush Suppression
Small
Programmable I/O
Set Up Software
Intelligent Accel/Decel
Auto Tuning
Parameter Copy Facility
Can be Remotely
Mounted
Full Monitoring
Optional
FR-PU04 Keypad
Run Time Display
easy to maintain
On/Off Functionality
Quick Change
Fault Finding
Parameter Update
Process Mapping
Set Up Software
Long Life Design
Cassette Fans
Parameter
Copy Facility
Low Maintenance
Requirements
high accuracy
Speed
Holding
Protection
Torque
Slip Compensation
Auto Tuning
Sensorless Vector
300% at 3Hz
High Response Current Limited
Stall Prevention
THE AUTOMATION NETWORK
Mitsubishi Electric Europe, Automation Systems Division UK, Travellers Lane, Hatfield, Herts AL10 8XB. Fax: 01707 278695
Mitsubishi Electric Europe, Westgate Business Park, Ballymount, Dublin 24, Ireland. Fax (01)- 4564422
Connect with our Web Site: www.industrial.meuk.co.uk
MITSUBISHI BROCHURE HOTLINE: 0990 168567
CTE = Centres of Technical Excellence
ENGLAND
Logicon Systems Ltd CTE
West Sussex Tel: 01444 259500
Prolocon Systems Limited
Hatfield Tel: 01707 275887
Pneumatic Lines Ltd CTE
Suffolk Tel: 01284 706239
Huntingdon Tel: 01480 432104
Controls and Drives Ltd CTE
Leicester Tel: 0116 233 9555
BPX & Pneumatic Lines
Dudley Tel: 01384 355455 (BPX)
Tel: 01384 357400 (PL)
BPX Electro Mechanical Co Ltd CTE
Nottingham Tel: 0115 970 4531
Staffs Tel: 01782 564 400
Leeds Tel: 0113 270 5656
Newton Tesla Electric Drives Ltd
Cheshire Tel: 01925 444773
Betech 2000 Ltd
West Yorks Tel: 01274 851105
L C Automation Ltd CTE
Chippenham Tel: 01249 460099
Preston Tel: 01772 334951
Sunderland Tel: 0191 549 7377
SCOTLAND
Alfred J Hurst Scotland Ltd CTE
Glasgow Tel: 0141 952 0089
WALES
Western Automation CTE
Cardiff Tel: 01222 488446
IRELAND
Ashdale Engineering Ltd
Belfast Tel: 01232 781911
Advanced Electrical Manufacturing Ltd
Banteer, Co. Cork Tel: 00 353 29 58284
Industrial Solutions
Drogheda, County Louth
Tel: 00 353 41 30465
Mullingar, County Westmeath
Tel: 00 353 44 48414
Drives & Controls Ltd
Tallaght, Dublin
Tel: 00 3531 45 16574
Automation & Control
Engineering Ltd
Churchtown, Dublin
Tel: 00 3531 29 62033
Electrical Rewinds
Limerick Tel: 00 353 61 417070
Garland Instrument Services
Nenagh, County Tipperary
Tel: 00 353 67 32822
Part No: BRO-E500-0599-GKL
All trademarks recognised
Your local Mitsubishi approved distributor:
FR-E520S-K-EC FR-E540-K-EC
Output Rating Model Reference
0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5
Motor capacity(kW) (Note 1)
0.4 (0.75) 0.75 (1.1) 1.5 (2.2) 2.2 (3) 0.4 (0.75) 0.75 (1.1) 1.5 (2.2) 2.2 (3) 3.7 (5.5) 5.5 (7.5) 7.5 (11)
Rated capacity (kVA) (Note 2)
0.95 1.5 2.7 3.8 1.2 2.0 3.0 4.6 7.2 9.1 13.0
Rated output current (A)
2.5 (3) 4 (5) 8 (11) 11 (12.8) 1.6 (1.8) 2.6 (3) 4 (6) 6 (7.5) 9 (10.5) 12 (17) 17 (23)
Overload capacity (Note 1) 150 (120)% for 60 secs, 200 (150)% for 0.5 secs
Rated output voltage (Note 4) Three phase, 200V to 240V 50Hz/60Hz Three phase, 380V to 480V 50Hz/60Hz
Power supply Rated input AC voltage, frequency Single phase, 200V to 240V 50Hz/60Hz Three phase, 380V to 480V 50Hz/60Hz
Permissible AC voltage fluctuation Single phase, 170 to 264V 50Hz/60Hz Three phase, 325V to 528V 50Hz/60Hz
Permissible frequency fluctuation Within ±5%
Power supply capacity (kVA) (Note 5)
1.5 2.3 4.0 5.2 1.5 2.5 4.5 5.5 9 12 17
Protective structure Enclosed type (IP20)
Cooling system Self-cooling Forced air cooling Self-cooling Forced air cooling
Dimensions (mm) W
140 140 140 140 140 140 140 140 140 220 220
H 150 150 150 150 150 150 150 150 150 150 150
D 136 136 166 166 116 116 136 136 136 148 148
Control Control system Soft-PWM control/high carrier frequency PWM control can be selected. V/F control or general-purpose magnetic
Specifications flux vector control can be selected.
Operation functions Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic
restart operation after instantaneous power failure, forward/reverse rotation prevention, slip compensation,
operation mode selection, offline auto tuning function, PID control, computer link operation (RS-485).
Output signals Operating status 2 open collector output signals can be selected from inverter running, up to frequency, frequency detection,
overload alarm, zero current detection, output current detection, PID upper limit, PID lower limit, PID
forward/reverse rotation, operation ready, minor fault and alarm, and 1 contact output (230VAC 0.3A, 30VDC
0.3A) can be selected.
For meter 1 signal can be selected from output frequency, motor current and output voltage. Analog output (0 to 10VDC).
Output frequency range 0.2 to 400Hz (starting frequency variable between 0 and 60Hz)
Voltage/frequency characteristic Base frequency set as required between 0 and 400Hz. Constant torque or variable torque pattern can be selected.
Acceleration/deceleration time setting 0.01, 0.1 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern
acceleration/deceleration mode can be selected.
Braking torque Regenerative (Note 3) 0.4K, 100% or more, 0.4K, 0.75K, 100% or more, 1.5K, 50% or more,
0.75K, 1.5K, 2.2K 20% or more 2.2K, 3.7K, 5.5K, 7.5K, 20% or more
DC dynamic brake Operation frequency (0 to 120Hz), operation time (0 to 10 s), operation voltage (0 to 30%) variable.
Current stall prevention operation level Operation current level can be set (0 to 200% variable), presence or absence can be selected.
Voltage stall prevention operation level Operation level is fixed, presence or absence can be selected.
Fast-response current limit level Operation level is fixed, presence or absence can be selected.
Input signals Frequency Analog input 0 to 5VDC, 0 to 10VDC, 4 to 20mADC
setting signal Digital input Entered from control panel (optional FR-PA02-02).
Start signal Forward and reverse rotation, start signal automatic self-holding input (3-wire input) can be selected.
Alarm reset Used to reset alarm output provided when protective function is activated.
Multi-speed selection Up to 15 speeds can be selected. (Each speed can be set between 0 and 400Hz, Use Pr. 180 to Pr. 183
running speed can be changed during operation from the control panel.) for selection.
Second function selection Used to select second functions (acceleration time, deceleration time, torque boost, base frequency, electronic
overcurrent protection).
Protective/alarm functions Overcurrent shut-off (during acceleration, deceleration, constant speed), regenerative overvoltage shut-off,
undervoltage (Note 1), instantaneous power failure (Note 1), overload shut-off (electronic overcurrent protection),
brake transistor alarm, output short circuit, stall prevention, brake resistor overheat protection, fin overheat, fan
failure (Note 4), parameter error, PU disconnection, ground fault over current protection.
Display Control panel display Operating status Output voltage, output current, set frequency, running.
Alarm definition Alarm definition is displayed when protective function is activated. 4 alarm definitions are stored.
LED display Power application (POWER), Alarm (ALARM).
SPECIFICATIONS
Note: 1. Figures in brackets indicate ratings for variable torque loads (e.g. pump and fan)
2. The rated output capacity indicated assumes that the output voltage is 220V/380V.
3. The overload capacity indicated in % is the ratio of the overload current to the inverter's rated output current.
For repeated duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.
4. The maximum output voltage does not exceed the power supply voltage. The maximum output voltage may be set
as desired below the power supply voltage.
5. The power supply capacity changes with the values of the power supply side inverter impedances (including those
of the input reactor and cables). Use the power supply capacity larger than the indicated