THE AUTOMATION NETWORK
Mitsubishi Electric Europe, Automation Systems Division UK, Travellers Lane, Hatfield, Herts AL10 8XB. Fax: 01707 278695
Mitsubishi Electric Europe, Westgate Business Park, Ballymount, Dublin 24, Ireland. Fax (01)- 4564422
Connect with our Web Site: www.industrial.meuk.co.uk
MITSUBISHI BROCHURE HOTLINE: 0990 168567
CTE = Centres of Technical Excellence
ENGLAND
Logicon Systems Ltd CTE
West Sussex Tel: 01444 259500
Prolocon Systems Limited
Hatfield Tel: 01707 275887
Pneumatic Lines Ltd CTE
Suffolk Tel: 01284 706239
Huntingdon Tel: 01480 432104
Controls and Drives Ltd CTE
Leicester Tel: 0116 233 9555
BPX & Pneumatic Lines
Dudley Tel: 01384 355455 (BPX)
Tel: 01384 357400 (PL)
BPX Electro Mechanical Co Ltd CTE
Nottingham Tel: 0115 970 4531
Staffs Tel: 01782 564 400
Leeds Tel: 0113 270 5656
Newton Tesla Electric Drives Ltd
Cheshire Tel: 01925 444773
Betech 2000 Ltd
West Yorks Tel: 01274 851105
L C Automation Ltd CTE
Chippenham Tel: 01249 460099
Preston Tel: 01772 334951
Sunderland Tel: 0191 549 7377
SCOTLAND
Alfred J Hurst Scotland Ltd CTE
Glasgow Tel: 0141 952 0089
WALES
Western Automation CTE
Cardiff Tel: 01222 488446
IRELAND
Ashdale Engineering Ltd
Belfast Tel: 01232 781911
Advanced Electrical Manufacturing Ltd
Banteer, Co. Cork Tel: 00 353 29 58284
Industrial Solutions
Drogheda, County Louth
Tel: 00 353 41 30465
Mullingar, County Westmeath
Tel: 00 353 44 48414
Drives & Controls Ltd
Tallaght, Dublin
Tel: 00 3531 45 16574
Automation & Control
Engineering Ltd
Churchtown, Dublin
Tel: 00 3531 29 62033
Electrical Rewinds
Limerick Tel: 00 353 61 417070
Garland Instrument Services
Nenagh, County Tipperary
Tel: 00 353 67 32822
Part No: BRO-E500-0599-GKL
All trademarks recognised
Your local Mitsubishi approved distributor:
FR-E520S-K-EC FR-E540-K-EC
Output Rating Model Reference
0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5
Motor capacity(kW) (Note 1)
0.4 (0.75) 0.75 (1.1) 1.5 (2.2) 2.2 (3) 0.4 (0.75) 0.75 (1.1) 1.5 (2.2) 2.2 (3) 3.7 (5.5) 5.5 (7.5) 7.5 (11)
Rated capacity (kVA) (Note 2)
0.95 1.5 2.7 3.8 1.2 2.0 3.0 4.6 7.2 9.1 13.0
Rated output current (A)
2.5 (3) 4 (5) 8 (11) 11 (12.8) 1.6 (1.8) 2.6 (3) 4 (6) 6 (7.5) 9 (10.5) 12 (17) 17 (23)
Overload capacity (Note 1) 150 (120)% for 60 secs, 200 (150)% for 0.5 secs
Rated output voltage (Note 4) Three phase, 200V to 240V 50Hz/60Hz Three phase, 380V to 480V 50Hz/60Hz
Power supply Rated input AC voltage, frequency Single phase, 200V to 240V 50Hz/60Hz Three phase, 380V to 480V 50Hz/60Hz
Permissible AC voltage fluctuation Single phase, 170 to 264V 50Hz/60Hz Three phase, 325V to 528V 50Hz/60Hz
Permissible frequency fluctuation Within ±5%
Power supply capacity (kVA) (Note 5)
1.5 2.3 4.0 5.2 1.5 2.5 4.5 5.5 9 12 17
Protective structure Enclosed type (IP20)
Cooling system Self-cooling Forced air cooling Self-cooling Forced air cooling
Dimensions (mm) W
140 140 140 140 140 140 140 140 140 220 220
H 150 150 150 150 150 150 150 150 150 150 150
D 136 136 166 166 116 116 136 136 136 148 148
Control Control system Soft-PWM control/high carrier frequency PWM control can be selected. V/F control or general-purpose magnetic
Specifications flux vector control can be selected.
Operation functions Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic
restart operation after instantaneous power failure, forward/reverse rotation prevention, slip compensation,
operation mode selection, offline auto tuning function, PID control, computer link operation (RS-485).
Output signals Operating status 2 open collector output signals can be selected from inverter running, up to frequency, frequency detection,
overload alarm, zero current detection, output current detection, PID upper limit, PID lower limit, PID
forward/reverse rotation, operation ready, minor fault and alarm, and 1 contact output (230VAC 0.3A, 30VDC
0.3A) can be selected.
For meter 1 signal can be selected from output frequency, motor current and output voltage. Analog output (0 to 10VDC).
Output frequency range 0.2 to 400Hz (starting frequency variable between 0 and 60Hz)
Voltage/frequency characteristic Base frequency set as required between 0 and 400Hz. Constant torque or variable torque pattern can be selected.
Acceleration/deceleration time setting 0.01, 0.1 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern
acceleration/deceleration mode can be selected.
Braking torque Regenerative (Note 3) 0.4K, 100% or more, 0.4K, 0.75K, 100% or more, 1.5K, 50% or more,
0.75K, 1.5K, 2.2K 20% or more 2.2K, 3.7K, 5.5K, 7.5K, 20% or more
DC dynamic brake Operation frequency (0 to 120Hz), operation time (0 to 10 s), operation voltage (0 to 30%) variable.
Current stall prevention operation level Operation current level can be set (0 to 200% variable), presence or absence can be selected.
Voltage stall prevention operation level Operation level is fixed, presence or absence can be selected.
Fast-response current limit level Operation level is fixed, presence or absence can be selected.
Input signals Frequency Analog input 0 to 5VDC, 0 to 10VDC, 4 to 20mADC
setting signal Digital input Entered from control panel (optional FR-PA02-02).
Start signal Forward and reverse rotation, start signal automatic self-holding input (3-wire input) can be selected.
Alarm reset Used to reset alarm output provided when protective function is activated.
Multi-speed selection Up to 15 speeds can be selected. (Each speed can be set between 0 and 400Hz, Use Pr. 180 to Pr. 183
running speed can be changed during operation from the control panel.) for selection.
Second function selection Used to select second functions (acceleration time, deceleration time, torque boost, base frequency, electronic
overcurrent protection).
Protective/alarm functions Overcurrent shut-off (during acceleration, deceleration, constant speed), regenerative overvoltage shut-off,
undervoltage (Note 1), instantaneous power failure (Note 1), overload shut-off (electronic overcurrent protection),
brake transistor alarm, output short circuit, stall prevention, brake resistor overheat protection, fin overheat, fan
failure (Note 4), parameter error, PU disconnection, ground fault over current protection.
Display Control panel display Operating status Output voltage, output current, set frequency, running.
Alarm definition Alarm definition is displayed when protective function is activated. 4 alarm definitions are stored.
LED display Power application (POWER), Alarm (ALARM).
SPECIFICATIONS
Note: 1. Figures in brackets indicate ratings for variable torque loads (e.g. pump and fan)
2. The rated output capacity indicated assumes that the output voltage is 220V/380V.
3. The overload capacity indicated in % is the ratio of the overload current to the inverter's rated output current.
For repeated duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.
4. The maximum output voltage does not exceed the power supply voltage. The maximum output voltage may be set
as desired below the power supply voltage.
5. The power supply capacity changes with the values of the power supply side inverter impedances (including those
of the input reactor and cables). Use the power supply capacity larger than the indicated