246 www.recom-international.comApril-2005
Specifications (typical at nominal input and 25°C unless otherwise noted)
POWERLINE
DC/DC-Converter RP30-S_DEW
Series
Output Voltage Accuracy (full Load and nominal Vin) ±1%
Voltage Adjustability ±10%
Minimum Load Single 0%
Dual 10% of FL
Line Regulation (LL-HL at full load) ±0.5%
Load Regulation (25% to 100% FL) Single ±0.5%
Dual ±1%
Cross Regulation (Note 9) ±5%
Ripple and Noise (20MHz bandwith) Single 1.5, 1.8, 2.5, 3.3V 60mVp-p
(Measured with a 1004pF/50V MLCC) Single 5V 75mVp-p
Single 12, 15V 100mVp-p
Dual 5, 12, 15V 100mVp-p
Temperature Coefficient ±0.02%/°C, max.
Transient Response (25% load step change) 300µS
Over Voltage Protection 1.5, 1.8, 2.5, 3.3V 3.9V
Zener diode clamp (only single) 5V 6.2V
12V 15V
15V 18V
Over Load Protection (% of full load at nominal Vin) 150% typ
Short Circuit Protection Hiccup, automatic recovery
Efficiency see „Selection Guide“ table
Isolation Voltage 1.600VDC min.
Isolation Resistance 109Ωmin.
Isolation Capacitance 1000pF max.
Operating Frequency 300kHz typ.
Approved to Safety Standards EN60950
Operating Temperature Range -40°C to +85°C(with derating)
Maximum Case Temperature +100°C
Storage Temperature Range -55°C to +105°C
Over Temperature Protection 115°C typ.
Thermal Impedance Natural convection 10°C/Watt
Natural convection with Heat Sink 8.24°C/Watt
Thermal Shock MIL-STD-810D
Vibration 10-55Hz, 2G, 30 Min. along X, Y and Z
Relative Humidity 5% to 95% RH
Case Material Nickel-Coated copper
Base Material Non-conductive black plastic
Potting Material Epoxy (UL94-V0)
Conducted Emissions EN55022 Class A
Radiated Emissions EN55022 Class A
ESD EN61000-4-2 Perf. Criteria 2
Radiated Immunity EN61000-4-3 Perf. Criteria 2
Fast Transient EN61000-4-4 Perf. Criteria 2
Surge EN61000-4-5 Perf. Criteria 2
Conducted Immunity EN61000-4-6 Perf. Criteria 2
continued on next page