Rated Rated
Part Output Output Overall Overall Ripple
Number Voltage Current Regulation Regulation Noise Efficiency
ADP35WA12.0/ 12 V 2.6 A 0~2.9 A 11~13 V 450 mVpp 83%
ADP35WC12.0
ADP35WA13.5/ 13.5 V 2.5 A 0~2.6 A 12.5~14.5V 400 mVpp 82%
ADP35WC13.5
ADP35WA15.0/ 15 V 2.3 A 0~2.3 A 14~16 V 350 mVpp 84%
ADP35WC15.0
ADP35WA16.0/ 16 V 2.2 A 0~2.2 A 15~17V 300 mVpp 83%
ADP35WC16.0
Single Output, 35 Watt, Universal AC-DC Power Supplies
The ADP 35WA and 35WC Series are light, compact, and
efficient power supplies. These supplies are ideal for a wide
range of limited space applications from notebook
computers to industrial instrumentation. The ADP Series
quietly delivers continuous power, while complying with
international safety standards. The ADP Series are enclosed
in a modern molded plastic case.
Features
• High Efficiency 82% to 84% Nominal
• Ultra Miniature Size, 100mm x 63mm x 27mm
• Light Weight, 250g
• Universal Input, 90 to 265 Vac
• Meets FCC & CISPR Level “B” EMI Requirements
• Tight Voltage Regulation
• Over-Current Protected
• Meets Worldwide Safety Standards
• WA Series – Constant Voltage, Constant Current Type
• WC Series – Constant Voltage, Current Foldback Type
3100 Tower Boulevard
5th Floor University Tower
Durham, NC 27707
(919)402-1320 Fax: (919)402-8540
ADP 35WA/35WC Series
Note: 13.5 V Output available as 3 pin input option.
INPUT
Input Voltage Universal, 90 to 265 V
Input Frequency 47 to 63 Hz
Input Current 1.0 A or less
Inrush Current 100 A or less at cold start
Leakage Current 100 µA max (240 V, 50 Hz)
Efficiency 82% to 84% nominal, full load
AC Turn-on Time 1.3 sec. at 90 V
OUTPUT
Output Power 35 W
Over-Current Protection Yes, Constant current
Over-Voltage Protection Yes, Shut down
Thermal Protection Yes, Shut down
Reset Time after Shutdown 32 sec. at 240 V
ENVIRONMENTAL
Operating Temperature 0~+40°C
Storage Temperature -20~+80°C
Cooling Free air convection
Storage Humidity 10~90%
Operation Humidity 20~80%
Specifications subject to change without notice.
ADP 35WA/35WC Series
SPECIFICATIONS VIBRATION
Frequency 5~100 Hz
Amplitude 25mm (max)
Acceleration 0.5 G
Sweep Time 60 sec.
Direction X,Y, Z
Vibration Time 10 min.
SHOCK
Storage Passes lifting the unit and
dropping it from 1 meter high
to an oak board.
3 times, with no damage
Operation Shock acceleration: 2.0 G,
Sine wave: 10 ms
Direction of force: X,Y,Z
Apply 10 times in 1 sec. intervals
EMI Regulations VCCI Class-II
FCC Class-B (115 V)
CISPR22 Class-B (230 V)
Safety Standards Dentori
UL 1950, UL 1310
CSA No. 950 (WA), C-UL No.1950(WC)
TUV EN60950
Hi-Pot Test P-S 3 kv 1 min. (10 mA or less)
Insulation Resistance P-S DC 500 V, 50 Mor more
13.5 mm
11.5 mm
27 mm
13 mm
20.5 mm
100 mm
63 mm
16.5 mm
2.5 mm
28 mm 9.5 mm
Ø2.1 mm
Ø5.5 mm
+50
-0
1800 mm