Limit Switches E47 Precision Switch 2.0 Introduction Technical Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 E47 Precision Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 V8-T2-49 V8-T2-50 E50 Heavy-Duty Plug-In Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7 V8-T2-43 V8-T2-44 E49 Compact Metal Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6 V8-T2-21 V8-T2-23 E49 Mini Metal Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-Titan Miniature DIN Switch V8-T2-15 V8-T2-16 LS-Titan Miniature DIN Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 V8-T2-6 V8-T2-7 Compact Prewired Switches Compact Prewired Switch 2.3 V8-T2-2 V8-T2-3 V8-T2-54 V8-T2-55 E50 Heavy-Duty Factory Sealed 6P+ Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-68 V8-T2-69 E49 Compact Metal Switch 2.8 Operators Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9 Non Plug-In Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10 V8-T2-89 V8-T2-90 Hazardous Location Limit Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Factory Sealed 6P+ Switch 2.11 V8-T2-80 V8-T2-81 V8-T2-92 V8-T2-93 Special Purpose Limit Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-96 V8-T2-97 Unless otherwise noted, the products contained in this section should not be used for functional safety applications. These products were not designed or tested to IEC 60947-5-3 or recommended for functional safety. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Learn Online 2 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-1 2 2 2.0 2 2 Limit Switches Introduction Technical Reference Limit Switches 2 2 2 2 2 2 2 2 2 2 2 Mechanical Limit Switches are contact sensors widely used for detecting the presence or position of objects in industrial applications. 2 2 2 2 2 Limit Switches offer high precision in terms of accuracy and repeatability. This is primarily due to the fact that they make direct contact with the target. When an object contacts the limit switch lever (or plunger) the lever moves a pre-travel distance to the operating point where the contacts are tripped. Movement of the lever beyond this point is called the over-travel. Limit switches contain the following major components. These may be modular or part of a single-piece switch. Limit Switch Components Actuator/ Operating Head Pre-travel Operating Point Over-travel Initial Position 2 Receptacle/ Terminals Reset Point 2 Switch Body 2 Differential 2 2 Initial Position Pre-travel Differential 2 Over-travel Reset Point Operating Point Final Position 2 2 2 Actuator/ Operating Head Lever Type Actuator 2 2 Switch Body Actuator Terminals This is the part of the switch that contacts the target. Typical actuators are levers and plungers. Several styles are available, see Sensor Learning Course, Page V8-T12-4, for more information. The terminals are the point of connection for the wiring. These terminals may be on the body itself, or housed in a removable receptacle. The limit switch may also come equipped with a factory installed cable or pinconnector. Switch Body Refer to Sensor Learning Course, Page V8-T12-4, for a complete description of limit switch terminology. 2 V8-T2-2 This part contains the electrical contact mechanism. For complete information on electrical outputs, see Sensor Learning Course, Page V8-T12-4. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches Introduction 2.0 Product Selection Guide E47 Precision Switches 2 Compact Prewired Switches LS-Titan Miniature DIN Switches E49 Mini Metal Switches 2 2 2 2 2 Page V8-T2-6 Page V8-T2-15 Page V8-T2-21 Page V8-T2-43 2 Overview Overview Overview Overview 2 Specified when accurate repeatability, choice of operating forces and travel characteristics and tightly controlled action of cam or target in space restricted areas are of prime importance. Cost effective and compact. Designed to be a versatile, slim device for hard to fit applications where sealing integrity is required. Safety position switches with insulated plastic or rugged metal enclosures. Approved for worldwide safety application. Suitable for OEMs who require a small, cost-effective solution but cannot sacrifice durability and mechanical life as they would if they chose a plastic IEC style switch. Applications Applications Applications Applications Overhead, folding and elevator doors, sliding gates, automated guided vehicles and commercial instrumentation Machine tool, food processing and packaging Automatic vending machines, electronic assembly machines, elevators and lifts, injection molding, packaging and safety applications Automatic vending machines, electronic assembly machines, elevators and lifts, injection molding, packaging Product Features Product Features Product Features Product Features Self-contained switches or with an enclosed cast housing for increased durability and conduit connection (1/2 in NPT) Rugged aluminum alloy die cast housing Modular plug-in head and body components Sealed construction with enclosure ratings of NEMA 4, 6 and 13 Positive opening NC contacts for safety applications Pre-wired units with custom cable lengths available for high volume customers Prewired with 3m of 18 AWG, AWM 2517, 300V cable Operating heads can be rotated 90 degrees to suit specific direction of operation High current capacity for power load switching and motor handling capability Screw and solder terminations Stackable ridge for ganged operation 2 2 2 2 2 2 "Fingerproof" terminals protect against accidental shock Double-spring mechanism for contact reliability Grounding terminal included 2 2 2 Booted enclosed version shields actuators from debris Captive screws on enclosure cover make wiring hassle-free Mounting centers--1.0 in (25.4 mm), #8 screw size 2 SPDT double break 2 Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Mechanical life: 3,000,000 operations min. Mechanical life: 10,000,000 operations min. Mechanical life: 8,000,000 operations Contact ratings-- 5A at 250 Vac 5A at 30 Vdc Contact ratings-- NEMA B300 Contact ratings-- AC-15, 6A at 24V, 6A at 230/240V, 4A at 400/415V; DC-13, 3A at 24V, 800 mA at 110V, 300 mA at 220V Enclosure ratings-- NEMA 4, 6 and 13; IP67, IP69K Enclosure ratings-- IP66, IP67 (by model) Construction-- Aluminum alloy die cast Construction-- Plastic or metal (by model) Approvals Approvals Approvals Approvals UL(R) Recognized CSA(R) Certified CE cULus Safety function, IEC/EN 60947-5-1 TUV-Rheinland certified (LSE models) CSA certified UL listed CE CCC UL Recognized CE Electrical life: 500,000 operations min. Contact ratings-- NEMA A600, R300, AC-15, DC-13 15A/20A, 125 or 250 Vac Enclosure ratings-- Enclosed: NEMA 1 Construction-- Basic: Phenolic Enclosed: Aluminum die cast Electrical life: 200,000 operations 30 operations min. 2 2 Enclosure ratings-- IP65 2 Construction-- Zinc alloy 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-3 2.0 Limit Switches Introduction E49 Compact Metal Switches E50 Heavy-Duty Plug-In Switches E50 Heavy-Duty Factory Sealed 6P+ Switches Operators 2 Page V8-T2-49 Page V8-T2-54 Page V8-T2-68 Page V8-T2-80 2 Overview Overview Overview Overview Designed with high mechanical strength for robust environments. The rugged Aluminum die cast construction provides reliable, oiltight, waterproof and dustproof sealing for a variety of applications. Snap action 1NO1NC contacts provide flexibility in design. Versatile in design. High reliability. Low maintenance costs with installation ease. BEST CHOICE for Heavy-Duty Limit Switch applications. Withstands physical and chemical abuse of harsh industrial environments. Designed specifically to withstand the penetrating properties of new cutting fluids (coolants), acid or caustic washes, salt spray, severe vibration, shock and temperature fluctuations, grit and debris. Wide variety of operator types for rotary and wobble style limit switches. Applications Applications Applications Applications Packaging, material handling conveyors, end-of-travel and guarding operations, baler/compactor, industrial door lifts Punch presses, waste water treatment, machine tool, automotive, retrieval systems, industrial truck, car wash lines Automotive, pulp and paper, food processing, waste management, primary metals, machine tool (cutting, forming, bending) Used with E50, E50 6P+ and 10316 limit switches Product Features Product Features Product Features Product Features Rigid die cast switch housing Modular operating heads, switch bodies and receptacles are interchangeable without field adjustment Tamperproof, one-piece switch body assembly, epoxy filled Rollers and rods available in metal and nonmetal contact surfaces 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Set position indicator plate for easy maintenance High mechanical strength Oiltight, waterproof and dustproof construction 2 2 2 2 90 degree total travel, 5 degree pre-travel characteristics are standard features Viton(R) gasket, boot, and seal material offers exceptional chemical resistance 2 2 Order as complete assemblies or components for stocking and manufacturing flexibility Rotary head operating mode from CW, CCW or CW and CCW is easily changed without tools Factory sealed. 6P submersible. Pre-wired with cable, pigtail or pin connector options. All with ground connection Utilizes E50 modular operating heads Special V-seal on switch body/head connection provides hermetic barrier against fluid ingress LED indicating light, 24V-120 Vac/dc neon version too Peel off see-through painting mask over nameplate Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Mechanical life: 15,000,000 operations min. Mechanical life: 13,000,000 operations min. Mechanical life: 35,000,000 operations min. Varies by model Electrical life: 500,000 operations min. at full load Electrical life: 1,000,000 operations min. at full load (single-pole) Contact ratings-- NEMA A600, R300; AC-15, DC-13 Electrical life: 1,000,000 operations min. at full load Contact ratings-- NEMA A600, R300 Lighted versions A150, R150 6A, 120 Vac; 10A continuous 2 Enclosure ratings-- NEMA 4, 4X, 6, 6P, 12, 13; IP65, IP67 Contact ratings-- NEMA A600, R300 Lighted versions A150, R150 6A, 120 Vac; 10A continuous 2 Construction-- Aluminum die cast Enclosure ratings-- NEMA 1, 3, 3S, 4, 4X, 6, 6P, 13; IP67 Enclosure ratings-- NEMA 1, 2, 3, 3S, 4, 4X, 6, 6P, 13; IP67, IP69K 2 Construction--Zinc die cast Construction--Zinc die cast Approvals Approvals Approvals Approvals 2 cULus IP67 UL Listed CSA Certified IEC 947-5-1 TUV CE (some models) UL Listed CSA Certified IEC 947-5-1 TUV CE (some models) Varies by model 2 2 2 2 V8-T2-4 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches Introduction Non Plug-In Switches Hazardous Location Switches 2.0 2 Special Purpose Switches 2 2 2 2 Page V8-T2-89 Page V8-T2-92 Page V8-T2-96 2 Overview Overview Overview 2 The Industrial standard for Non Plug-In Heavy-Duty Limit Switches. Sold as complete assembled units only. Designed for severe environmental service in locations where there exists a danger of an internal or external explosion of flammable gases, vapors, metal alloy or grain dust. Variety of special function limit switch products. 2 Applications Applications Applications 2 Serving MRO and USER replacement requirements with broad d market coverage Mining, metal cutting, grain storage, forest products, petrochemical, waste and sewage management, pharmaceutical Serving MRO and USER replacement requirements with broad market coverage 2 Product Features Product Features Product Features Side and top rotary, side and top push or wobble operation Sealed and unsealed versions available Special function switch lines include: One-way gasket on sealed version keeps liquids out, yet allows a harmless release of gases in the event of an internal explosion Cabinet door interlocks -- when plunger is pulled out, red band indicator visually shows that interlock is defeated Silicon bronze housing provides excellent corrosion resistant properties in extreme NEMA 4X applications Precision switches--1NO-1NC, 2NO-2NC, or operator only. Variety of mounting brackets available Temperature build-up on limit switch surface is dissipated by housing design and materials used Pneumatic time delay--ON delay and OFF delay. Timing range--0.05 to 60 seconds CW, CCW or CW and CCW operating modes are field convertible Double break-make snap action contacts, same polarity each pole Captive saddle clamp terminals accept up to #12 wire Head can be mounted in any of four discrete positions, intervals of 90 degrees 2 2 2 2 2 2 2 Rotating cam shaft switches 2 Utilizes the operating heads and internal switch mechanisms of the 10316 Non Plug-In line 2 Technical Data and Specifications Technical Data and Specifications Mechanical life: 10,000,000 operations min. NEMA 7, Div. 1, Class I, BCD See Page V8-T2-99 for more information NEMA 9, Div. 1, Class II, EFG Electrical life: 500,000 operations at full load Contact ratings--NEMA B600 3A, 120 Vac; 5A continuous Enclosure ratings-- NEMA 1 or NEMA 4 versions 2 Contact ratings--NEMA A600, R300 6A, 120 Vac; 10A continuous Enclosure ratings--LX: NEMA 7, 9 CX: NEMA 1, 4, 7, 9 CB: NEMA 1, 4, 4X, 13 CBX: NEMA 1, 4, 4X, 7, 9, 13 Construction-- Zinc die cast PS: Phenolic 2 Enclosure ratings--NEMA 1, 4, 13 Construction-- Zinc die cast Technical Data and Specifications 2 2 2 Construction--LX, CX: Aluminum die cast CB, CBX: Silicon bronze Approvals Approvals Approvals 2 UL Listed CSA Certified cUL(R) Listed UL Listed CSA Certified (PS and J only) 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-5 2.1 2 Limit Switches E47 Precision Switches Contents E47 Precision Switches Description 2 Page E47 Precision Switches Product Selection Basic Switches . . . . . . . . . . . . . . . . . . . . . . Enclosed Switches. . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 2 2 V8-T2-7 V8-T2-9 V8-T2-10 V8-T2-10 V8-T2-12 Drawings Online 2 2 2 2 2 E47 Precision Switches 2 Product Description Features E47 Precision Switches from Eaton's electrical sector provide high accuracy switching at an affordable price. A variety of standard features, such as current capacity, operating force, travel characteristics and actuators, lets you custom fit the switch to your application. 2 2 2 2 2 2 2 The switches are available in their compact basic form, or enclosed in a rugged, metal housing. 2 Compact housings are ideal for use where space is restricted Precision, snap-action operators provide accurate repeatability of electrical and mechanical operating characteristics High current capacity (up to 20A) allows power load switching and motor handling capability Enclosed booted versions shield actuators from debris Operating Characteristics Definitions UL Recognized CSA Certified CE RoHS DANGER 2 2 Standards and Certifications OF--Operating Force RF--Return Force PT--Pre-Travel OT--Over-Travel MD--Movement Differential FP--Free Position OP--Operating Position 2 2 2 2 THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com V8-T2-6 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E47 Precision Switches 2.1 Product Selection 2 Basic Switches 2 E47 Precision Switches--Basic Type Pin Plunger Solder terminal Solder terminal Solder terminal Solder terminal Spade terminal Solder terminal E47CML01 2 OF max.--12.3 oz (350g) RF max.--4.02 oz (114g) PT max.--0.016 in (0.4 mm) OT max.--0.063 in (1.6 mm) MD max.--0.002 in (0.05 mm) OP--1.11 in (28.2 mm) E47BMS03 -- E47BML03 -- OF max.--12.3 oz (350g) RF max.--4.02 oz (114g) PT max.--0.016 in (0.4 mm) OT max.--0.063 in (1.6 mm) MD max.--0.002 in (0.05 mm) OP--0.846 in (21.5 mm) E47BMS02 E47CMS02 E47BML02 E47CML02 OF max.--5.29 oz (150g) RF max.--0.49 oz (14g) PT max.--0.16 in (4 mm) OT max.--0.063 in (1.6 mm) MD max.--0.051 in (1.3 mm) FP max.--0.81 in (20.6 mm) OP--0.685 in (17.4 mm) E47BMS21 -- 2 E47BML21 -- 2 E47BMT21 -- 2 2 2 2 2 2 2 2 2 2 2 OF max.--2.47 oz (70g) RF min.--0.49 oz (14g) PT max.--0.394 in (10 mm) OT max.--0.220 in (5.6 mm) MD max.--0.051 in (1.3 mm) FP max.--1.11 in (28.2 mm) OP--0.748 in (19 mm) E47BMS22 E47CMS22 E47BML22 -- OF max.--3.53 oz (100g) RF min.--0.99 oz (28g) PT max.--0.197 in (5.0 mm) OT max.--0.079 in (2.0 mm) MD max.--0.039 in (1.0 mm) FP max.--0.976 in (24.8 mm) OP--0.748 in (19 mm) E47BMS20 E47BML20 -- OF max.--12.3 oz (350g) RF max.--4.02 oz (114g) PT max.--0.016 in (0.4 mm) OT max.--0.217 in (5.5 mm) MD max.--0.002 in (0.05 mm) OP--0.858 in (21.8 mm) E47BMS04 E47CMS04 2 E47BMT04 -- 2 E47BML04 E47CML04 2 2 2 Standard Lever Screw terminal Solder terminal Extended Straight Plunger E47BML01 2 Straight Lever Screw terminal Standard Lever E47CMS01 Reversed Lever Screw terminal Straight Lever E47BMS01 Straight Plunger Screw terminal Reversed Lever OF max.--12.3 oz (350g) RF max.--4.02 oz (114g) PT max.--0.016 in (0.4 mm) OT max.--0.005 in (0.13 mm) MD max.--0.002 in (0.05 mm) OP--0.626 in (15.9 mm) 2 Extended Plunger Screw terminal Straight Plunger 20A Catalog Number Pin Plunger Screw terminal Extended Plunger 2 15A Catalog Number Specifications 1 2 -- 2 2 2 Extended Straight Plunger Screw terminal Screw terminal (with space lugs) Solder terminal 2 Notes 1 OF = Operating Force; RF = Return Force; PT = Pre-Travel; OT = Over-Travel; MD = Movement Differential; FP = Free Position; OP = Operating Position. 2 Contact Eaton's Sensor Applications Department at 1-800-426-9184 for approval status. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2 2 V8-T2-7 2.1 Limit Switches E47 Precision Switches 2 E47 Precision Switches--Basic, continued 2 Type Roller Plunger 2 2 2 2 Solder terminal Cross Roller Plunger 2 2 2 Solder terminal Reversed Roller Lever Solder terminal 2 2 Extended Roller Lever 2 2 Solder terminal Roller Lever Screw terminal 2 Solder terminal 2 Spade terminal One-Way Roller 2 Solder terminal 2 2 Integral Leaf Solder terminal 2 2 OF max.--12.3 oz (350g) RF max.--4.02 oz (114g) PT max.--0.016 in (0.4 mm) OT max.--0.14 in (3.6 mm) MD max.--0.002 in (0.05 mm) OP--1.315 in (33.4 mm) E47BMS11 E47CMS11 E47BML11 -- OF max.--5.29 oz (150g) RF max.--0.49 oz (14g) PT max.--0.16 in (4 mm) OT max.--0.063 in (1.6 mm) MD max.--0.051 in (1.3 mm) FP max.--1.252 in (31.8 mm) OP--1.126 in (28.6 mm) E47BMS41 -- E47BML41 -- OF max.--5.64 oz (160g) RF min.--0.78 oz (22g) PT max.--0.28 in (7.1 mm) OT max.--0.16 in (4 mm) MD max.--0.04 in (1.02 mm) FP max.--1.437 in (36.5 mm) OP--1.189 in (30.2 mm) E47BMS42 E47CMS42 E47BML42 -- OF max.--5.64 oz (160g) RF min.--1.48 oz (42g) PT max.--0.106 in (2.7 mm) OT max.--0.094 in (2.4 mm) MD max.--0.02 in (0.5 mm) FP max.--1.28 in (32.5 mm) OP--1.189 in (30.2 mm) E47BMS30 E47CMS30 E47BML30 -- E47BMT30 E47CMT30 OF max.--5.64 oz (160g) RF min.--1.48 oz (42g) PT max.--0.106 in (2.7 mm) OT max.--0.094 in (2.4 mm) MD max.--0.02 in (0.5 mm) FP--1.717 in (43.6 mm) OP--1.697 in (43.1 mm) E47BMS31 -- E47BML31 -- OF max.--0.35 oz (10g) RF min.--0.106 oz (3.0g) PT max.--0.787 in (20.0 mm) OT max.--0.22 in (5.6 mm) MD max.--0.118 in (3.0 mm) OP--0.748 in (19.0 mm) E47BMS23 E47CMS23 E47BML23 -- Integral Leaf Screw terminal 2 -- One-Way Roller Screw terminal 2 E47BML10 Roller Lever 2 2 E47CMS10 Extended Roller Lever Screw terminal 2 E47BMS10 Reversed Roller Lever Screw terminal 2 OF max.--12.3 oz (350g) RF max.--4.02 oz (114g) PT max.--0.016 in (0.4 mm) OT max.--0.14 in (3.6 mm) MD max.--0.002 in (0.05 mm) OP--1.315 in (33.4 mm) Cross Roller Plunger Screw terminal 2 20A Catalog Number Roller Plunger Screw terminal 2 15A Catalog Number Specifications 1 Note 1 OF = Operating Force; RF = Return Force; PT = Pre-Travel; OT = Over-Travel; MD = Movement Differential; FP = Free Position; OP = Operating Position. 2 2 V8-T2-8 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E47 Precision Switches 2.1 E47 Precision Switches--Basic, continued Type Adjustable Roller 20A Catalog Number OF max.--17.64 oz (500g) RF min.--6.0 oz (170g) PT max.--0.197 in (5.0 mm) OT max.--0.5 in (12.7 mm) MD max.--0.087 in (2.2 mm) FP max.--1.752 in (44.5 mm) OP--1.591 in (40.4 mm) E47BMS40 -- E47BML40 -- OF max.--21.16 oz (600g) RF min.--10.58 oz (300g) PT max.--0.118 in (3.0 mm) OT max.--0.236 in (6.0 mm) MD max.--0.079 in (2.0 mm) FP max.--1.614 in (41 mm) OP--1.591 in (40.4 mm) E47BMS43 -- E47BML43 -- 2 2 Adjustable Roller Screw terminal Solder terminal Extended Adjustable Roller 15A Catalog Number Specifications 1 2 2 2 2 Extended Adjustable Roller Screw terminal Solder terminal 2 2 2 2 2 Enclosed Switches 2 E47 Precision Switches--Enclosed Specifications 1 Plunger Actuator Booted Plunger E47BLS05 2 E47BLS33 2 Booted Roller Lever OF max.--22.57 oz (640g) RF min.--8.11 oz (230g) PT max.--0.197 in (5.0 mm) OT max.--0.236 in (6.0 mm) MD max.--0.016 in (0.4 mm) E47CLS05 23 Catalog Number 2 2 2 Booted Plunger OF max.--28.22 oz (800g) RF min.--8.46 oz (240g) PT max.--0.079 in (2.0 mm) OT max.--0.197 in (5.0 mm) MD max.--0.004 in (0.1 mm) OP--1.803 in (45.8 mm) Roller Lever Booted Roller Lever Plunger Actuator OF max.--8.82-12.3 oz (250-350g) RF min.--4.02 oz (114g) PT max.--0.016 in (0.4 mm) OT max.--0.217 in (5.5 mm) MD max.--0.002 in (0.05 mm) OP--1.504 in (38.2 mm) Specifications 1 Catalog Number E47BLS06 Roller Plunger Roller Plunger OF max.--8.82-12.3 oz (250-350g) RF min.--4.02 oz (114g) PT max.--0.02 in (0.5 mm) OT max.--0.142 in (3.6 mm) MD max.--0.002 in (0.05 mm) OP--1.957 in (49.7 mm) E47CLS06 23 2 E47BLS07 E47BLS11 4 Roller Lever OF max.--20.1 oz (570g) RF min.--6.0 oz (170g) PT max.--0.157 in (4.0 mm) OT max.--0.236 in (6.0 mm) MD max.--0.016 in (0.4 mm) E47BLS32 E47CLS32 23 Booted Roller Plunger 2 2 Booted Roller Plunger OF max.--17.64 oz (500g) RF min.--3.53 oz (100g) PT max.--0.039 in (1.0 mm) OT max.--0.138 in (3.5 mm) MD max.--0.005 in (0.12 mm) OP--1.957 in (49.7 mm) 2 2 E47BLS08 E47BLS12 4 2 2 2 Notes 1 OF = Operating Force; RF = Return Force; PT = Pre-Travel; OT = Over-Travel; MD = Movement Differential; FP = Free Position; OP = Operating Position. 2 Contact Eaton's Sensor Applications Department at 1-800-426-9184 for approval status. 3 20 ampere version. 4 Cross roller unit. 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-9 2.1 Limit Switches E47 Precision Switches 2 E47 Precision Switches-- Enclosed, continued 2 Specifications 1 One-Way Roller E47 Precision Switches-- Enclosed, continued One-Way Roller 2 OF max.--20.1 oz (570g) RF min.--6.0 oz (170g) PT max.--0.157 in (4.0 mm) OT max.--0.236 in (6.0 mm) MD max.--0.016 in (0.4 mm) 2 Specifications 1 Catalog Number Booted Wobble E47BLS34 Catalog Number Booted Wobble OF max.--2.11 oz (60g) RF min.--0.88 oz (25g) PT max.--0.520 in (13.2 mm) OT max.--0.315 in (8.0 mm) MD max.--0.039 in (1.0 mm) E47BLS14 Description Catalog Number Terminal wire cover with 90 conduit interface E47PA2 2 2 2 Booted One-Way Roller Booted One-Way Roller OF max.--22.57 oz (640g) RF min.--8.11 oz (230g) PT max.--0.197 in (5.0 mm) OT max.--0.236 in (6.0 mm) MD max.--0.016 in (0.4 mm) 2 2 E47BLS35 2 2 2 Accessories 2 Terminal Wire Covers for Basic Switches 2 2 45 Description Catalog Number Terminal wire cover with 45 conduit interface E47PA1 90 2 2 2 2 Technical Data and Specifications 2 E47 Precision Switches Description Specification 2 Operating speed 0.01m/second to 1m/second Operating Frequency 2 Mechanical 120 operations/minute 2 Electrical 20 operations/minute Mechanical life 3,000,000 operations minimum 2 Electrical life 500,000 operations minimum Contact resistance 15M ohms maximum, initial 2 Insulation resistance 100M ohms minimum at 500 Vdc 2 2 2 Dielectric Strength Between non-current carrying parts 1000 Vac, 50/60 Hz for 1 minute Between current carrying parts and ground 2000 Vac, 50/60 Hz for 1 minute Notes 1 OF = Operating Force; RF = Return Force; PT = Pre-Travel; OT = Over-Travel; MD = Movement Differential; FP = Free Position; OP = Operating Position. 2 Cross roller unit. 2 2 V8-T2-10 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E47 Precision Switches 2.1 E47 Precision Switches, continued Description Specification 2 -13 to 176F (-25 to 80C) 2 Ambient Operating Temperature Basic Enclosed 2 5 to 176F (-15 to 80C) Environmental rating enclosed, booted NEMA 1 Mounting centers 1.0 in (25.4 mm), #8 screw size 2 Terminal screws Bottom facing M4 x 0.7 (8-32) Screws with cup washers will accept 22-12 AWG (2.5 sq. mm maximum) Maximum torque: 10 in-lbs. 2 Threaded bushing 15/32 in Material of construction Mineral filled phenolic Enclosure rating Aluminum die casting (ADC-3/A380); Seal boot: nitrile, butyl rubber (NBR) Conduit fitting on enclosed type 1/2 in NPT 2 2 2 2 Maximum Ampere Ratings 1 2 Non-Inductive Load (A) Inductive Load (A) Lamp Load Inductive Load Motor Load Inrush Current (A) Model Rated Voltage Resistive Load NC and NO NC NO NC and NO NC NO NC NO 15A 125 Vac 15 3 1.5 15 5 2.5 30 max. 15 max. 20A 250 Vac 15 2.5 1.25 15 3 1.5 500 Vac 3 1.5 0.75 2.5 1.5 0.75 8 Vdc 15 3 1.5 15 5 2.5 14 Vdc 15 3 1.5 10 5 2.5 30 Vdc 6 (2) 3 1.5 5 5 2.5 125 Vdc 0.4 0.4 0.4 0.05 0.05 0.05 250 Vdc 0.2 0.2 0.2 0.03 0.03 0.03 125 Vac 20 7.5 7.5 20 12.5 12.5 250 Vac 20 7.5 7.5 20 8.3 8.3 500 Vac 6 4 4 5 2 2 8 Vdc 20 3 1.5 20 12.5 12.5 14 Vdc 20 3 1.5 15 12.5 12.5 30 Vdc 6 3 1.5 5 5 5 125 Vdc 0.5 0.5 0.5 0.05 0.05 0.05 250 Vdc 0.25 0.25 0.25 0.03 0.03 0.03 2 2 2 2 2 2 60 max. 2 30 max. 2 2 2 2 2 Terminal Configurations Screw Type 2 Solder Type 2 2 2 Contact Configuration-- Form C Precision Snap Action 2 2 (Spade type not shown, available on some models) 2 Notes 1 Inductive load has a power factor of 0.04 minimum (AC) and a time constant of 7 m/second (DC). 2 Lamp load has an inrush current of six times steady-state current. 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-11 2.1 2 Limit Switches E47 Precision Switches Dimensions Approximate Dimensions in Inches [mm] 2 Basic Switches 2 Pin Plunger Standard Lever Extended Plunger Extended Straight Plunger Straight Plunger Roller Plunger Reversed Lever Cross Roller Plunger Straight Lever Reversed Roller Lever 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V8-T2-12 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E47 Precision Switches 2.1 Approximate Dimensions in Inches [mm] Extended Roller Lever 2 Integral Leaf 2 2 2 2 Roller Lever 2 Adjustable Roller 2 2 2 2 2 One-Way Roller Extended Adjustable Roller 2 2 2 2 2 2 Enclosed Switches Plunger Actuator 2 Roller Lever 2 2 2 2 2 2 Booted Plunger Booted Roller Lever 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-13 2.1 Limit Switches E47 Precision Switches 2 Approximate Dimensions in Inches [mm] 2 Roller Plunger Booted One-Way Roller Booted Roller Plunger Booted Wobble 2 2 2 2 2 2 2 0.25 [6.5] Dia. 2 0.37 [9.5] 2 5.91 [150] 0.67 [17] 2-M4.0 x 45 3.37 [85.5] 0.08 [2.1] 1.00 [25.5] 0.96 [24.5] 0.91 [23] 2 2 PT 1.00 [25.4] 1.00 [25.4] One-Way Roller 2 2 2 2 2 2 53 25.4 21 14 2 2-o4.2 2-o4.2 39 46 18 12 14 25 2 53 25.4 21 21 2 2 Terminal Wire Cover with 90 Conduit Interface 7 Terminal Wire Cover with 45 Conduit Interface 21 2 Approximate Dimensions in mm 14 2 Accessories 7 2 12 14 2 2 2 2 V8-T2-14 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com A B A B 12 Limit Switches Compact Prewired Switches 2.2 Contents Compact Prewired Switches Description Page Compact Prewired Switches Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-16 V8-T2-18 V8-T2-18 V8-T2-19 2 2 2 2 2 Drawings Online 2 2 2 2 2 2 Compact Prewired Switches Product Description Features The E47 Compact Prewired Limit Switch by Eaton's electrical sector is designed to be a versatile, slim device for hard to fit applications where sealing integrity is required. The rugged die cast aluminum alloy housing, cable connection and switch mechanism are encapsulated for protection against extreme temperature (-10 to 70C [14 to 158F]), contaminants, moisture, shock and vibration. This factory wired (3m) device has NEMA(R) enclosure ratings of 4, 6 and 13, making it suitable for applications such as machine tool, food processing and packaging. Standards and Certifications Rugged aluminum alloy die cast housing Sealed construction with enclosure ratings of NEMA 4, 6 and 13 Prewired with 3m of 18 AWG, AWM 2517, 300V cable, or microconnector version also available Stackable ridge for ganged operation cULus (cable versions only) UL (cable versions only) NEMA 4, 6 and 13 IEC IP67, IP69K RoHS 2 DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-15 2 2 2.2 2 Limit Switches Compact Prewired Switches Product Selection 2 Compact Prewired Switches 2 Actuator Type Operating Force (Maximum) Pin Plunger Pin Plunger 2 42.3 oz (1.2 kg) 2 Pre-Travel Movement Differential (Maximum) Operating Position Standard Version Catalog Number Connector Version Catalog Number 0.118 in (3 mm) 0.07 in (1.8 mm) 0.008 in (0.2 mm) 0.62 0.04 in (15.7 1 mm) E47BCC05 E47BCC05P4 15.9 oz (450g) 0.118 in (3 mm) 0.07 in (1.8 mm) 0.008 in (0.2 mm) 0.99 0.04 in (24.9 1 mm) E47BCC06 E47BCC06P4 15.9 oz (450g) 0.118 in (3 mm) 0.07 in (1.8 mm) 0.008 in (0.2 mm) 1.12 0.04 in (28.5 1 mm) E47BCC07 E47BCC07P4 0.118 in (3 mm) 0.07 in (1.8 mm) 0.008 in (0.2 mm) 1.35 0.04 in (34.3 1 mm) E47BCC08 E47BCC08P4 0.118 in (3 mm) 0.07 in (1.8 mm) 0.008 in (0.2 mm) 1.12 0.04 in (28.5 1 mm) E47BCC11 E47BCC11P4 15.9 oz (450g) 0.118 in (3 mm) 0.07 in (1.8 mm) 0.008 in (0.2 mm) 1.35 0.04 in (34.3 1 mm) E47BCC12 E47BCC12P4 15.9 oz (450g) 0.118 in (3 mm) 0.07 in (1.8 mm) 0.008 in (0.2 mm) 1.12 0.04 in (28.5 1 mm) E47BCC13 E47BCC13P4 Reset Force (Minimum) Over-Travel (Maximum) 15.9 oz (450g) 2 2 Sealed Plunger Sealed Plunger 63.5 oz (1.8 kg) 2 2 2 Roller Plunger 2 Roller Plunger 42.3 oz (1.2 kg) 2 2 2 Sealed Roller Plunger Sealed Roller Plunger 63.5 oz (1.8 kg) 2 15.9 oz (450g) 2 2 Cross Roller Plunger 2 Cross Roller Plunger 42.3 oz (1.2 kg) 15.9 oz (450g) 2 2 2 Sealed Cross Roller Plunger Sealed Cross Roller Plunger Bevel Plunger Bevel Plunger 2 63.5 oz (1.8 kg) 2 2 2 42.3 oz (1.2 kg) 2 2 2 2 2 V8-T2-16 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches Compact Prewired Switches 2.2 Compact Prewired Switches, continued Actuator Type Operating Force (Maximum) Roller Lever Roller Lever 20.5 oz (580g) Reset Force (Minimum) Over-Travel (Maximum) 5.3 oz (150g) 40 2 Pre-Travel Movement Differential (Maximum) Operating Position Standard Version Catalog Number Connector Version Catalog Number 25 max. 3 -- E47BCC15 E47BCC15P4 2 2 2 2 2 Wobble Stick Wobble Stick 5.3 oz (150g) -- -- 15 max. -- -- E47BCC20 E47BCC20P4 2 2 2 2 Rod Lever 2 Rod Lever 20.5 oz (580g) 5.3 oz (150g) 40 25 max. 3 -- -- E47BCC21P4 2 2 2 2 Adjustable Level Arm Adjustable Level Arm 20.5 oz (580g) 5.3 oz (150g) 40 25 max. 3 -- E47BCC22 E47BCC22P4 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-17 2.2 Limit Switches Compact Prewired Switches 2 Technical Data and Specifications 2 Compact Prewired Switches Description Specification 2 Contacts 1-SPDT (Form C) Mechanical life 10,000,000 operations 2 Electrical life 200,000 operations, 30 operation/min. at rated load 2 Operating speed 30 operations per minute maximum Operating temperature range -10 to 70C (14 to 158F) 2 Storage temperature range -10 to 70C (14 to 158F) Humidity 95% maximum non-condensing 2 Vibration Malfunction durability, 10 to 55 Hz 1.5 mm double amplitude 2 Shock Malfunction durability, approximately 50G Enclosure ratings NEMA 4, 6 and 13; IEC IP67 2 2 Maximum Ampere Ratings 1 Non-Inductive Load (A) Inductive Load (A) 2 Rated Voltage Resistive Load Inductive Load Motor Load NC NO NC NO NC NO NC NO 2 125 Vac 5 5 3 3 2.5 1.3 20 max. 10 max. Inrush Current (A) 250 Vac 5 5 2 2 1.5 0.8 2 8 Vdc 5 5 5 4 1.5 1.5 2 14 Vdc 5 5 4 4 1.5 1.5 30 Vdc 4 4 3 3 1.5 1.5 125 Vdc 0.4 0.4 0.4 0.4 0.05 0.05 250 Vdc 0.2 0.2 0.2 0.2 0.03 0.03 2 2 2 2 Wiring Diagram Compact Prewired Switches Micro-Connector Switches Contacts Rated 1.0A at 124 Vac 1.0A at 30 Vdc NC (Red) 2 2 2 1 2 NC 2 2 2 COM 1 NO (Blue) Common (Black) Ground (Green) 3 4 NO 4 3 Face View of Male Connector Note 1 Inductive load ratings are tested at a power factor 0.4 min. for AC power and a time constant of 7 ms max. for DC power. Inrush current for motor load is six times the steady state current. 2 2 2 2 2 2 2 V8-T2-18 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.2 Limit Switches Compact Prewired Switches Dimensions 2 Approximate Dimensions in mm [in] E47BCC05 2 x O10.2 [0.402] Depth: 6 [0.236] 40.0 [1.575] 25.0 [0.984] PT 2 x O5.1 [O0.201] O10 [0.397] Stainless Steel Plunger OP 7.5 [0.295] 8.0 [0.315] 54.2 [2.134] Max 49.0 [1.929] 23.0 2.0 [0.079] [0.906] 2.0 [0.079] 1.4 [0.055] 34.0 [1.339] PT 2.8 [0.110] Correct Setting Postion 1.5 [0.059] PT OP 63.5 [2.5] 49.0 Max. [1.929] 67.0 [2.638] Max 51.5 [2.028] 2 x O5.1 [O0.201] 8.0 [0.315] 16.0 [0.630] Max 2.0 [0.079] 34.0 [1.339] 2 2.8 [0.110] Correct Setting Position 2 2 2 1.5 [0.059] 1.4 [0.055] 2 2 1.4 [0.055] 34.0 [1.339] 40.0 [1.575] 2 x O10.2 [0.402] Depth: 6 [0.236] O12.7 [0.500] x 4.0 3.8 [0.150] [0.157] Stainless Steel Roller 7.5 [0.295] 8.0 [0.315] PT 1.5 [0.059] 73.0 [2.874] Max. 49.0 [1.929] 2 16.0 [0.630] Max 2 x O5.1 [O0.201] OP Rubber Cap 23.0 2.0 [0.906] [0.079] 2 Rubber Cap 2 2 23.0 2.0 [0.906] [0.079] 2.0 [0.079] 2 1.5 [0.059] 1.4 [0.055] 34.0 [1.339] 2 2 E47BCC13 40.0 [1.575] Max PT OP 67.0 [2.638] Max 2 x O5.1 [O0.201] 2 x O10.2 [0.402] Depth: 6 [0.236] 7.0 O12.7 [0.500] x [0.276] 3.8 [0.150] Stainless Steel Roller 7.5 [0.295] 8.0 [0.315] 16.0 [0.630] Max 2.8 [0.110] Correct Setting Position 23.0 2.0 [0.906] [0.079] 51.5 [2.028] 2.0 [0.079] 34.0 [1.339] 1.4 [0.055] 1.5 [0.059] E47BCC08 40.0 [1.575] 25.0 [0.984] PT OP 16.0 [0.630] 2 x O5.1 [O0.201] 2 x O10.2 [0.402] Depth: 6 [0.236] 7.0 O10 [0.397] [0.276] Stainless Steel PLU 8.0 [0.315] 23.0 2.0 [0.906] [0.079] 2.0 [0.079] 34.0 [1.339] 2 2.8 [0.110] Correct Setting Position 7.5 [0.295] 67.0 [2.638] Max 51.5 [2.028] 2 2 2 2 1.5 [0.059] 1.4 [0.055] 2 2 E47BCC15 40.0 [1.575] Max 2 x O5.1 [O0.201] 2 x O10.2 [0.402] Depth: 6 [0.236] 4.0 [0.157] O12.7 [0.500] x 3.8 [0.150] Stainless Steel Roller 7.5 [0.295] PT OP 73.0 [2.874] Max. 49.0 [1.929] 8.0 [0.315] 16.0 [0.630] Max O17.0 [0.669] x 7.0 [0.276] Stainless Sintered Roller 2 x O5.1 [O0.201] Rubber Cap 2x O10.2 [0.402] Depth: 6 [0.236] 23.0 2.0 [0.079] [0.906] 23.0 [0.906] 2.0 [0.079] 2 23.0 2.0 [0.906] [0.079] 25.0 [0.984] E47BCC07 25.0 [0.984] 2 x O5.1 [O0.201] E47BCC12 40.0 [1.575] 2 x O10.2 [0.402] Depth: 6 [0.236] O10 [0.397] 4.0 Stainless [0.157] Steel Plunger 7.5 [0.295] 25.0 [0.984] 16.0 [0.630] Max 2 x O10.2 [0.402] Depth: 6 [0.236] O12.7 [0.500] 7.0 x 3.8 [0.150] [0.276] Stainless Steel Roller 7.5 [0.295] 8.0 [0.315] OP E47BCC06 2.0 [0.079] 40.0 [1.575] Max 25.0 [0.984] 16.0 [0.630] Max 4.5 [0.177] 25.0 [0.984] 2 E47BCC11 34.0 [1.339] 1.4 [0.055] 1.5 [0.059] 44.0 [1.732] 25.0 [0.984] 16.0 [0.630] Max 7.0 [0.276] 11.4 [0.45] 7.5 [0.30] 2.0 [0.079] 34.0 [1.339] 40.0 [1.575] 102.7 [4.043] Max 1.4 [0.055] 2 2 31.5 [1.240] R38 [1.496] 8.0 2.0 [0.079] [0.31] 50.0 [1.969] Max. 2 2 65.0 [2.559] Max 2 2 1.5 [0.059] 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-19 2.2 2 2 Compact Prewired Switches Approximate Dimensions in mm [in] E47BCC20 E47BCC22 O1.2 50.7 2 x O5.1 [O0.201] 4.0 [0.157] 2 8.0 [0.315] 49.0 [1.929] 2.0 [0.079] 25.0 [0.984] 2 1.4 [0.055] E47BCC21 O3.0 [0.117] 159.0 [6.257] 2 2 2 16.0 [0.630] 25.9 25.0 [1.020] [0.984] 23.0 [0.906] 2 2 2 8.0 [0.315] 2.0 [0.079] 2.0 [0.079] 34.0 [1.339] 40.0 [1.575] 18 AWG/4 UL, SJT (0) O8.5 [0.335] 1.3 [0.051] 1.5 [0.059] 18 AWG/4 UL, SJT (0) O8.5 [0.335] 2 2 2 2 2 2 2 2 2 V8-T2-20 2.0 [0.079] 1.3 [0.051] 40.0 [1.575] 18 AWG/4 UL, SJT (0) O 8.5 [0.335] 2 8.0 [0.315] 2.0 [0.079] 34.0 [1.339] 1.5 [0.059] 40.0 [1.575] 2 2 25.0 [0.984] 23.0 [0.906] 23.0 2.0 [0.906] [0.079] 34.0 [1.339] 2 2 Rubber Cap 7.5 [0.295] 2 2 16.0 [0.630] 2 x O10.2 [0.402] Depth: 6 [0.236] 2 2 R 25.0-89.0 [0.984-3.600] 5.7 103.7 [2.5] 51.2 [2.017] 7.0 [0.280] O17.5 [0.69] 16.0 [0.630] Max 2 2 Limit Switches Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 18 AWG/4 UL, SJT (0) O 8.5 [0.335] 1.5 [0.059] Limit Switches LS-Titan Miniature DIN Switches 2.3 Contents LS-Titan Miniature DIN Switches Description Page LS-Titan Miniature DIN Switches Product Identification . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . LS-Titan Plastic Safety Switches . . . . . . . . . LS-Titan Plastic Electronic Safety Position Switches . . . . . . . . . . . . . LS-Titan Metal Safety Switches . . . . . . . . . Understanding LS-Titan Electronic Safety Position Switches . . . . . . . . . . . . . Operating Point Adjustment . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Contact Travel Diagrams . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-22 V8-T2-23 V8-T2-23 V8-T2-26 V8-T2-30 V8-T2-32 V8-T2-32 V8-T2-33 V8-T2-34 V8-T2-37 V8-T2-40 2 2 2 2 2 2 2 2 2 2 2 LS-Titan Miniature DIN Switches Product Description Features Eaton's LS-TitanTM limit switch line is a complete offering of safety position switches designed for worldwide application. Economical insulated plastic or rugged metal enclosures and modular, plug-in operating heads and bodies make LS-Titan a flexible switching solution. A highlight of the LS-Titan switch line is the world's first electronic position switch (LSE models). These switches feature freely programmable operating points that can be set individually at any time. Additional LSE models provide analog outputs proportional to the actuator position. Standards and Certifications Modular, plug-in system (head and body components) Positive opening NC contacts for safety applications Wide variety of economical plastic and rugged metal versions available Operating heads can be rotated 90 degrees to suit specific direction of operation Unique electronic safety position switches (LSE models) provide analog (0-10 Vdc or 4-20 mA) outputs proportional to the actuator position and allow for easy configuration of a custom trip point Can be ordered as separate components (head and body) or as completely assembled switches Screw and Cage Clamp(R) (standard on LSE models and optionally available on mechanical models) connections provide larger wiring areas for easier installation Approved for worldwide application Safety function by positive opening contacts per IEC/EN 60947-5-1 up to Category 4 per EN 954-1 TUV-Rheinland Certified for Functional-Safety (LSE models) CSA certified UL listed CE CCC 2 2 2 2 2 2 2 2 Note: Cage Clamp is a registered trademark of Wago Kontakttechnik, 32423 Minden, Germany. 2 2 2 2 LS-Titan switches are suitable for use in safety applications designed to protect persons or processes. 2 2 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-21 2 2 2.3 2 Limit Switches LS-Titan Miniature DIN Switches Product Identification 2 1 2 2 2 2 2 2 2 3 2 4 5 6 2 7 2 8 9 j 2 2 2 2 2 2 2 2 2 k Notes 1 Basic device (see Pages V8-T2-23 to V8-T2-31) According to EN 50047 With screw-on cover Contacts: 1NO-1NC, 2NO, 2NC Cage Clamp, screw terminal As snap-action or standard-action switch As electronic snap-action switch (individually adjustable) As 4-20 mA analog signal encoder As 0-10 Vdc analog signal encoder 2 2 3 4 Fixing adapter (see Page V8-T2-33) Allows mounting of M22 pushbuttons Roller lever (see Pages V8-T2-23 and V8-T2-26) For one-sided operation with higher operating speed Angled roller lever (see Pages V8-T2-23, V8-T2-26 and V8-T2-30) For actuation along the unit axis 5 6 7 Rotary lever (see Pages V8-T2-23, V8-T2-27 and V8-T2-30) For actuation from the side, for pendulum movements Roller plunger (see Pages V8-T2-23, V8-T2-26 and V8-T2-30) For actuation from the side with low actuating force Adjustable roller lever (see Pages V8-T2-24, V8-T2-27, V8-T2-28 and V8-T2-30) For length adjustment as required 8 Actuating rod (see Pages V8-T2-25, V8-T2-29 and V8-T2-31) On conveyor belts for lightweight goods 9 Spring-rod (see Pages V8-T2-25, V8-T2-29 and V8-T2-31) For flexible actuation from all sides j Actuating rod (see Pages V8-T2-25, V8-T2-29 and V8-T2-31) Withdrawable mechanism from front k Pushbuttons from the M22 family; see M22 catalog (CA04716001E) or www.eaton.com/m22 Operating heads can be rotated by 90 degrees. 2 2 2 2 2 2 2 2 2 V8-T2-22 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.3 Limit Switches LS-Titan Miniature DIN Switches Product Selection 2 LS-Titan Plastic Safety Switches Plastic Safety Switch Body 2 Plastic Safety Switches LS-S02 LS-S20A LS-S11S Output Function 2NC with positive opening contacts 2NO with slow make/break 1NO and 1NC with positive opening contact 2 Terminal Connection Screw terminal 1 Screw terminal 1 Screw terminal 1 2 Contact Sequence 11 21 12 22 13 23 13 14 24 14 22 Contact Travel Assembled Switch 2 Switch Body Catalog Number 2 2 Snap-action contact 0 = contact closed = contact open 21 3.0 11-12 21-22 3.0 Zw = 4.5 mm 6.1 NC NC 0 2.1 13-14 23-24 2.1 ZW = 4.5 mm 6.1 NO NO 0 3.0 6.1 21-22 13-14 21-22 13-14 2 2 1.6 Zw = 5.5 mm 2 Operating Head Type 2 Top Push Roller Plunger Head Only Catalog Number Assembled Switch Catalog Number LS-XP LS-S02-P LS-S20A-P 2 LS-S11S-P 2 2 Long Roller Lever LS-XL LS-S02-L LS-S20A-L 2 LS-S11S-L 2 Short Roller Lever LS-XLS LS-S02-LS LS-S20A-LS 2 LS-S11S-LS 2 2 Large Roller Lever LS-XLB LS-S02-LB LS-S20A-LB 2 LS-S11S-LB 2 2 2 Angled Roller LS-XLA LS-S02-LA LS-S20A-LA 2 LS-S11S-LA 2 2 Rotary Lever LS-XRL LS-S02-RL LS-S20A-RL 2 LS-S11S-RL 2 2 2 Notes 1 Cage Clamp versions available. Contact Application Engineering. 2 For operating head dimensions, see Page V8-T2-40. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2 V8-T2-23 2.3 2 Plastic Safety Switch Body Limit Switches LS-Titan Miniature DIN Switches Plastic Safety Switches, continued Switch Body Catalog Number LS-S02 LS-S20A LS-S11S 2 Output Function 2NC with positive opening contacts 2NO with slow make/break 1NO and 1NC with positive opening contact 2 Terminal Connection Screw terminal 1 Screw terminal 1 Screw terminal 1 Contact Sequence 2 2 12 22 13 23 13 14 24 14 22 Contact Travel Assembled Switch 2 = contact open 3.0 11-12 21-22 6.1 NC NC 0 2.1 13-14 23-24 3.0 Zw = 4.5 mm 2 21 Snap-action contact 0 = contact closed 2 2.1 ZW = 4.5 mm 6.1 NO NO 0 3.0 21-22 13-14 21-22 13-14 1.6 Zw = 5.5 mm Operating Head Type 2 Head Only Catalog Number Assembled Switch Catalog Number Adjustable Roller Lever (with 18 mm Roller) LS-XRLA LS-S02-RLA LS-S20A-RLA LS-S11S-RLA Adjustable Roller Lever (with 30 mm Roller) LS-XRLA30 LS-S02-RLA30 LS-S20A-RLA30 LS-S11S-RLA30 Adjustable Roller Lever (with 40 mm Roller) LS-XRLA40 LS-S02-RLA40 LS-S20A-RLA40 LS-S11S-RLA40 Adjustable Roller Lever (with 40 mm Rubber Roller) LS-XRLA40R LS-S02-RLA40R LS-S20A-RLA40R LS-S11S-RLA40R 2 2 11 21 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Cage Clamp versions available. Contact Application Engineering. 2 For operating head dimensions, see Page V8-T2-40. 2 2 2 V8-T2-24 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 6.1 2.3 Limit Switches LS-Titan Miniature DIN Switches Plastic Safety Switch Body Plastic Safety Switches, continued LS-S02 LS-S20A LS-S11S Output Function 2NC with positive opening contacts 2NO with slow make/break 1NO and 1NC with positive opening contact Terminal Connection Screw terminal Contact Sequence 1 Screw terminal 11 21 12 22 1 Screw terminal 13 23 13 14 24 14 22 Contact Travel Assembled Switch 2 Switch Body Catalog Number 2 21 2 2 Snap-action contact 0 = contact closed = contact open 2 1 3.0 11-12 21-22 3.0 Zw = 4.5 mm 6.1 NC NC 0 2.1 13-14 23-24 2.1 ZW = 4.5 mm 6.1 NO NO 0 3.0 6.1 21-22 13-14 21-22 13-14 2 2 1.6 Zw = 5.5 mm 2 Operating Head Type 2 Plastic Rod Lever Head Only Catalog Number Assembled Switch Catalog Number LS-XRR LS-S02-RR LS-S20A-RR 2 LS-S11S-RR 2 2 2 2 Metal Rod LS-XRRM LS-S02-RRM LS-S20A-RRM LS-S11S-RRM 2 2 2 2 2 Spring Rod (Wobble) 3 LS-XS LS-S02-S LS-S20A-S 2 LS-S11S-S 2 2 2 Actuating Rod LS-XOR LS-S02-OR LS-S20A-OR 2 LS-S11S-OR 2 2 2 Notes 1 Cage Clamp versions available. Contact Application Engineering. 2 For operating head dimensions, see Page V8-T2-40. 3 Not to be used as a safety position switch. Use only in conjunction with snap-action contact. 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-25 2.3 Limit Switches LS-Titan Miniature DIN Switches 2 LS-Titan Plastic Electronic Safety Position Switches 2 Plastic Electronic Safety Position Switch Body 2 2 2 Plastic Electronic Safety Position Switches Switch Body Catalog Number LSE-11 LSE-02 LSE-AI Output Function 1NO and 1 NC 2NC Analog 4-20 mA Analog 0-10V Terminal Connections Cage Clamp 1 Cage Clamp 1 Cage Clamp 1 Cage Clamp 1 Safety Functions and Approvals These models may be used in safety-oriented circuits. Visual status LED indication is comparable to positive opening contacts. Certified by TUV as a "Functional-Safety" device. Suitable for protection of people or processes. Additional diagnostic output that registers a 0V signal in the event of a fault. Self-test function continuously tests both outputs for overloads, short circuits to 0V and short circuits to +Ue. Certified by TUV to EN 954-1, Category 3 or 4. Suitable for protection of people or processes. Contact Sequence +Ue Analog 4-20 mA 2 2 LSE-AU Assembled Switch 2 +Ue electron. 2 Q1 electron. Q2 Q1 0V 2 Contact Travel 2 Q1 = contact open Q2 Q2 0V 0 0.5 = contact closed Analog 0-10V 0 0.5 5.5 6.1 5.5 6.1 Q1 20 U [V] I [mA] 10 Q2 default=3.0 default=3.0 4 0 S [%] 100 S [%] 2 Operating Head Type 2 2 Head Only Catalog Number Assembled Switch Catalog Number Top Push Roller Plunger LS-XP LSE-11-P LSE-02-P LSE-AI-P LSE-AU-P Long Roller Lever LS-XL LSE-11-L LSE-02-L LSE-AI-L LSE-AU-L Short Roller Lever LS-XLS LSE-11-LS LSE-02-LS LSE-AI-LS LSE-AU-LS Large Roller Lever LS-XLB LSE-11-LB LSE-02-LB LSE-AI-LB LSE-AU-LB Angled Roller LS-XLA LSE-11-LA LSE-02-LA LSE-AI-LA LSE-AU-LA 2 0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 A compatible Cage Clamp tool is available as an accessory on Page V8-T2-33. 2 For operating head dimensions, see Page V8-T2-40. 2 2 V8-T2-26 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 100 2.3 Limit Switches LS-Titan Miniature DIN Switches Plastic Electronic Safety Position Switch Body Plastic Electronic Safety Position Switches, continued Switch Body Catalog Number LSE-11 Output Function 1NO and 1NC 2 LSE-02 LSE-AI 2NC 1 LSE-AU Analog 4-20 mA 1 Terminal Connections Cage Clamp Safety Functions and Approvals These models may be used in safety-oriented circuits. Visual status LED indication is comparable to positive opening contacts. Certified by TUV as a "Functional-Safety" device. Suitable for protection of people or processes. Cage Clamp Cage Clamp 2 Analog 0-10V 1 Cage Clamp 1 Additional diagnostic output that registers a 0V signal in the event of a fault. Self-test function continuously tests both outputs for overloads, short circuits to 0V and short circuits to +Ue. Certified by TUV to EN 954-1, Category 3 or 4. Suitable for protection of people or processes. 2 2 2 Assembled Switch Contact Sequence +Ue Q1 Q2 Q1 Q1 = contact open Q2 2 Q2 0V 0 0.5 = contact closed 2 Analog 0-10V electron. 0V Contact Travel Analog 4-20 mA +Ue electron. 0 0.5 5.5 6.1 Q1 5.5 6.1 20 I [mA] 2 U [V] 10 Q2 default=3.0 default=3.0 4 0 S [%] 100 S [%] 0 Head Only Catalog Number Assembled Switch Catalog Number LS-XRL LSE-11-RL 2 2 100 Operating Head Type 2 Rotary Lever 2 2 LSE-02-RL LSE-AI-RL 2 LSE-AU-RL 2 2 Adjustable Roller Lever (with 18 mm Roller) LS-XRLA LSE-11-RLA LSE-02-RLA LSE-AI-RLA 2 LSE-AU-RLA 2 2 2 2 2 Adjustable Roller Lever (With 30 mm Roller) LS-XRLA30 LSE-11-RLA30 LSE-02-RLA30 LSE-AI-RLA30 2 LSE-AU-RLA30 2 2 2 2 2 2 Notes 1 A compatible Cage Clamp tool is available as an accessory on Page V8-T2-33. 2 For operating head dimensions, see Page V8-T2-40. 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-27 2.3 2 2 Plastic Electronic Safety Position Switch Body 2 2 Limit Switches LS-Titan Miniature DIN Switches Plastic Electronic Safety Position Switches, continued Switch Body Catalog Number LSE-11 LSE-02 LSE-AI Output Function 1NO and 1NC 2NC Analog 4-20 mA Analog 0-10V Terminal Connections Cage Clamp 1 Cage Clamp 1 Cage Clamp 1 Cage Clamp 1 Safety Functions and Approvals These models may be used in safety-oriented circuits. Visual status LED indication is comparable to positive opening contacts. Certified by TUV as a "Functional-Safety" device. Suitable for protection of people or processes. Additional diagnostic output that registers a 0V signal in the event of a fault. Self-test function continuously tests both outputs for overloads, short circuits to 0V and short circuits to +Ue. Certified by TUV to EN 954-1, Category 3 or 4. Suitable for protection of people or processes. Contact Sequence +Ue Analog 4-20 mA 2 2 Assembled Switch 2 Q1 Contact Travel Q1 2 Q1 = contact open Q2 Q2 0V 0 0.5 = contact closed 0 0.5 5.5 6.1 5.5 6.1 Q1 20 I [mA] U [V] 10 Q2 default=3.0 default=3.0 4 0 2 Analog 0-10V electron. Q2 0V 2 S [%] 100 S [%] 0 100 Operating Head Type 2 2 2 +Ue electron. 2 2 LSE-AU Head Only Catalog Number Assembled Switch Catalog Number Adjustable Roller Lever (With 40 mm Roller) LS-XRLA40 LSE-11-RLA40 LSE-02-RLA40 LSE-AI-RLA40 LSE-AU-RLA40 Adjustable Roller Lever (With 40 mm Roller) LS-XRLA40R LSE-11-RLA40R LSE-02-RLA40R LSE-AI-RLA40R LSE-AU-RLA40R Plastic Rod Lever LS-XRR LSE-11-RR LSE-02-RR LSE-AI-RR LSE-AU-RR 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 A compatible Cage Clamp tool is available as an accessory on Page V8-T2-33. 2 For operating head dimensions, see Page V8-T2-40. 2 V8-T2-28 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.3 Limit Switches LS-Titan Miniature DIN Switches Plastic Electronic Safety Position Switch Body Plastic Electronic Safety Position Switches, continued Switch Body Catalog Number LSE-11 Output Function 1NO and 1NC 2 LSE-02 LSE-AI 2NC 1 LSE-AU Analog 4-20 mA Cage Clamp 1 Cage Clamp Terminal Connections Cage Clamp Safety Functions and Approvals These models may be used in safety-oriented circuits. Visual status LED indication is comparable to positive opening contacts. Certified by TUV as a "Functional-Safety" device. Suitable for protection of people or processes. 2 Analog 0-10V 1 Cage Clamp 1 Additional diagnostic output that registers a 0V signal in the event of a fault. Self-test function continuously tests both outputs for overloads, short circuits to 0V and short circuits to +Ue. Certified by TUV to EN 954-1, Category 3 or 4. Suitable for protection of people or processes. Assembled Switch Contact Sequence +Ue electron. Q1 Q1 Q2 = contact closed = contact open 0 0.5 Q1 Q1 Q2 Q2 default=3.0 2 Q2 0 0.5 5.5 6.1 default=3.0 20 I [mA] 4 0 U [V] 2 10 S [%] 100 2 S [%] 0 100 2 Operating Head Type 2 Metal Rod Head Only Catalog Number Assembled Switch Catalog Number LS-XRRM LSE-11-RRM 2 2 0V 5.5 6.1 2 2 Analog 0-10V electron. 0V Contact Travel Analog 4-20 mA +Ue 2 LSE-02-RRM LSE-AI-RRM 2 LSE-AU-RRM 2 2 2 2 2 Spring Rod (Wobble) 3 LS-XS LSE-11-S LSE-02-S LSE-AI-S 2 LSE-AU-S 2 2 2 2 2 Actuating Rod LS-XOR LSE-11-OR LSE-02-OR LSE-AI-OR LSE-AU-OR 2 2 2 2 2 Notes 1 A compatible Cage Clamp tool is available as an accessory on Page V8-T2-33. 2 For operating head dimensions, see Page V8-T2-40. 3 Not to be used as a safety position switch. Use only in conjunction with snap-action contact. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2 2 V8-T2-29 2.3 Limit Switches LS-Titan Miniature DIN Switches 2 LS-Titan Metal Safety Switches 2 Metal Safety Switch Body Metal Safety Switches Switch Body Catalog Number LSM-02 LSM-20A LSM-11S 2 Output Function 2NC with positive opening contacts 2NO with slow make/break 1NO and 1NC with positive opening contact 2 Terminal Connection Cage Clamp Cage Clamp Cage Clamp Contact Sequence 2 12 22 2 2 Assembled Switch 14 24 14 22 3.0 11-12 21-22 6.1 NC NC 0 2.1 13-14 23-24 2.1 ZW = 4.5 mm 3.0 Zw = 4.5 mm 2 2 13 Snap-action contact 0 = contact closed = contact open 21 13 23 Contact Travel 2 2 11 21 6.1 NO NO 0 3.0 21-22 13-14 21-22 13-14 1.6 Zw = 5.5 mm Operating Head Type 1 Head Only Catalog Number Assembled Switch Catalog Number Top Push Roller Plunger LSM-XP LSM-02-P LSM-20A-P LSM-11S-P Long Roller Lever LSM-XL LSM-02-L LSM-20A-L LSM-11S-L Angled Roller LSM-XLA LSM-02-LA LSM-20A-LA LSM-11S-LA Rotary Lever LSM-XRL LSM-02-RL LSM-20A-RL LSM-11S-RL Adjustable Roller Lever LSM-XRLA LSM-02-RLA LSM-20A-RLA LSM-11S-RLA 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note 1 For operating head dimensions, see Page V8-T2-40. 2 2 V8-T2-30 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 6.1 2.3 Limit Switches LS-Titan Miniature DIN Switches Metal Safety Switch Body Metal Safety Switches, continued Switch Body Catalog Number LSM-02 LSM-20A LSM-11S 2 Output Function 2NC with positive opening contacts 2NO with slow make/break 1NO and 1NC with positive opening contact 2 Terminal Connection Cage Clamp Cage Clamp Cage Clamp 2 Contact Sequence 11 21 12 22 13 23 13 14 24 14 22 Contact Travel = contact open 2 2 Snap-action contact 0 = contact closed Assembled Switch 21 3.0 11-12 21-22 3.0 Zw = 4.5 mm 6.1 NC NC 0 2.1 13-14 23-24 2.1 ZW = 4.5 mm 6.1 NO NO 0 3.0 6.1 21-22 13-14 21-22 13-14 2 2 1.6 Zw = 5.5 mm 2 Operating Head Type 1 Plastic Rod Lever Head Only Catalog Number Assembled Switch Catalog Number LSM-XRR LSM-02-RR LSM-20A-RR 2 LSM-11S-RR 2 2 2 2 2 2 Metal Rod Lever LSM-XRRM LSM-02-RRM LSM-20A-RRM LSM-11S-RRM 2 2 2 2 2 Spring Rod (Wobble) LSM-XS LSM-02-S LSM-20A-S 2 LSM-11S-S 2 2 2 2 2 2 Note 1 For operating head dimensions, see Page V8-T2-40. 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-31 2.3 2 2 2 2 2 2 2 Limit Switches LS-Titan Miniature DIN Switches Understanding LS-Titan Electronic Safety Position Switches All four LS-Titan LSE switch bodies are safety-rated products. The LSE-11 and LSE-02 switch bodies both have a freely programmable operating point and can be individually adjusted to suit the application, and can be changed as often as required. These devices feature an LED on the body, providing simple indication during programming and operation. 2 Operating Point Adjustment 2 LSE-11 This ensures that a safe operating state can be monitored and evaluated at any time. A self-test function is also present on these models. Outputs Q1 and Q2 are continuously tested for overloads, short circuits to 0V and short circuits to +Ue. The LSE-AI (4-20 mA) and LSE-AU (0-10V) analog position switches take position data and convert to an analog current or voltage value that can then be continuously fed into an automation system. These two switches also feature a diagnostic output for additional data processing. LSE-02 2 adjust fix 2 2 2 1s LED Set 2 fmax 2 N Set 2 2 2 Example of LS-Titan LSE Models in a Safety-Oriented Circuit +24V 2 LSE-11 2 S1 LSE-11 +Ue 2 2 S2 S3 +Ue Q1 Q1 Q1 Q2 Q2 0V R1 0V R2 2 2 0V 2 Notes LSE-11 and LSE-02--individual operating point adjustment. 2 LSE-11 and LSE-02 can be used in safety circuits. S1 is connected to 24 Vdc S2, S3 each switch with a delay of 0.7s R1, R2, for example, series element M22-XLED60 (2820 ohms/0.5W) 2 2 2 2 V8-T2-32 LS-_ S4 Q2 0V 2 LSE-11 +Ue Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com K1 Like the electromechanical position switches, LS-Titan electronic position switches meet Category 3 or 4 of the EN 954-1 standard for machine safety when configured as a redundant system. All devices are thus suitable for safety applications that are used for the protection of persons or processes. 2.3 Limit Switches LS-Titan Miniature DIN Switches Accessories 2 LS-Titan Safety Switches V1-2-M20 Description Notes Catalog Number Any M20 screw terminal in 1/2 in. For use with American pipe thread, metal. The screw connection must be earthed. Not total insulation. V1-2-M20-NA 2 Any M20 screw terminal in 1/2 in. For use with American pipe thread, molded material. -- V1-2-M20 2 Any M20 diaphragm bolt. With internal push-through membrane. Will fit cable with an external diameter of up to 13 mm. Rated IP65 with cable inserted. -- EMS20 M20 2 1/2 in EMS20 2 For Use With 2 2 LS-XTW Any Cage Clamp tool. -- 2 LS-XTW 2 M12A LS-Titan plastic bodies (LS-_) Plug connector, 12 mm, 4-pin male connector M12x1 (M12x1). Rated IP65. Molded material. Color coded to IEC/EN 60947-5-2. 1 1 1 2 2 2 3 3 3 4 4 4 2 M12A 4 2 3 1 2 2 ..-11-.. ..-20-.. ..-02-.. M12A5 LS-Titan metal bodies (LSM-_) Plug connector, 12 mm, 5-pin male connector (M12x1). Rated IP65. Molded material. Color coded to IEC/EN 60947-5-2. 1 1 1 2 2 2 3 3 3 4 4 4 2 2 M12A5 4 3 1 2 2 2 ..-11-.. ..-20-.. ..-02-.. M22-LS Any Allows mounting of M22 pushbuttons. (See the M22 catalog, CA04716001E, for a full selection of pushbuttons.) -- 2 M22-LS 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-33 2.3 Limit Switches LS-Titan Miniature DIN Switches 2 Technical Data and Specifications 2 LS-Titan Miniature DIN Switches--IP66, IP67 Complete Units 2 General 2 LS, LSM LSE-11/LSE-02 LSE-AI 1 LSE-AU 1 Standards IEC/EN 60947 IEC/EN 60947 EN 61000-4 IEC/EN 60947 EN 61000-4 IEC/EN 60947 EN 61000-4 Climatic proofing Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30 Units 2 2 Ambient temperature -13 to 158F (-25 to 70C) -13 to 158F (-25 to 70C) -13 to 158F (-25 to 70C) -13 to 158F (-25 to 70C) Mounting position As required As required As required As required 2 Protection type IP66, IP67 IP66, IP67 IP66, IP67 IP66, IP67 2 2 2 2 2 2 2 F (C) Terminal capacity of screw terminal and Cage Clamp Solid mm2 1 x (0.5-2.5) 1 x (0.5-2.5) 1 x (0.5-2.5) 1 x (0.5-2.5) Flexible with ferrules to DIN 46228 mm2 1 x (0.5-1.5) 1 x (0.5-1.5) 1 x (0.5-1.5) 1 x (0.5-1.5) Ue Vdc N/A 12-30 24 (-15%/+20%) 24 (-15%/+20%) 12V Ie mA N/A 15 N/A N/A 24V Ie mA N/A 18 28-45 24 30V I mA N/A 19 N/A N/A N/A N/A N/A Power Supply Rated voltage Burden current Contacts/Switching Capacity Rated impulse withstand voltage Uimp Vac 4000 Rated insulation voltage Ui V 400 N/A N/A N/A III/3 III/3 N/A N/A 2 Overvoltage category/ pollution degree 2 Rated Operational Current AC-15 2 24V Ie A 6 N/A N/A N/A 230V/240V A 6 N/A N/A N/A 2 Ie 400V/415V Ie A 4 N/A N/A N/A 2 DC-13 24V Ie A 3 0.2 N/A N/A 2 110V Ie A 0.8 N/A N/A N/A 220V Ie A 0.3 N/A N/A N/A 2 2 Note 1 The following applies for LSE-11 and LSE-02: ensure that the power supply operates correctly when setting the operating point. 2 2 2 2 2 2 2 2 V8-T2-34 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.3 Limit Switches LS-Titan Miniature DIN Switches LS-Titan Miniature DIN Switches--IP66, IP67 Complete Units. continued Units LS, LSM LSE-11/LSE-02 LSE-AI 1 2 LSE-AU 1 2 Burden Current Analog output Q1 Output voltage (max. 10 mA) Vdc N/A N/A Output current mA N/A N/A 4-20 Fault scenario V N/A N/A 0 2 0-10 2 0 Resolution Steps N/A N/A 100 100 Step tolerance Steps N/A N/A 1 1 Shunt resistor, resistive load ohms N/A N/A <400 >1000 V N/A N/A Approx. Ue Approx. Ue mA N/A N/A <200 <200 2 2 Digital diagnostics output Q2 (switching to + pole PNP) Response threshold 2 2 Control circuit reliability At 24 Vdc/5 mA HF Fault probability <10-7, <1 fault in 107 operations N/A N/A N/A 2 At 5 Vdc/1 mA HF Fault probability N/A <10-6, <1 failure at 5 x 106 operations N/A N/A 2 Hz Max. 400 N/A N/A N/A 2 A gG/gL 6 N/A N/A N/A mm 0.02 0.02 0.02 0.02 Supply frequency Short-circuit rating to IEC/EN 60947-5-1 Maximum fuse Repetition accuracy 2 2 2 Note 1 The following applies for LSE-11 and LSE-02: ensure that the power supply operates correctly when setting the operating point. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-35 2.3 2 Limit Switches LS-Titan Miniature DIN Switches LS-Titan Miniature DIN Switches--IP66, IP67 Complete Units Units LS, LSM LSE-11/LSE-02 LSE-AI/LSE-AU LSE-AI/LSE-AU 2 Mechanical Variables 2 Standard-action contact Operations X 106 8 N/A N/A N/A Snap-action contact Operations X 106 8 3 (electronic) N/A N/A C 100 100 100 100 Standard-action contact g 25 N/A N/A N/A Snap-action contact 9 N/A N/A N/A N/A Lifespan 2 Contact temperature of roller head 2 Mechanical shock resistance (half-sinusoidal shock, 20 ms) 2 2 2 Basic unit g Operating frequency Operations/h 30 30 30 3000 3000 3000 N/A 0.5-5.5 mm freely adjustable N/A N/A Hysteresis mm N/A 0.4 0.4 0.4 Contact sequence (contact closed open Zw = positive opening clearance) mm N/A 0.04 0.06 0.06 Basic units N 1.0/8.0 3.5/8.0 3.5/8.0 3.5/8.0 2 LS(M)-XP N 1.0/8.0 1.0/8.0 1.0/8.0 1.0/8.0 2 LS(M)-XL N 1.0/8.0 1.0/8.0 1.0/8.0 1.0/8.0 LS(M)-XLA N 1.0/8.0 1.0/8.0 1.0/8.0 1.0/8.0 Nm 0.2 0.2 0.2 0.2 2 2 2 2 2 2 2 Switching point N/A 6000 Actuation Mechanical Actuating force at beginning/ end of stroke Actuating torque of rotary drives Maximum operating speed with DIN cam Basic units for angle of actuation = 0/30 m/s 1/0.5 1/0.5 1/0.5 1/0.5 LS(M)-XRL for angle of actuation = 0 m/s 1.5 1.5 1.5 1.5 = 30, L = 125 mm LS(M)-XRLA for angle of actuation m/s 1.5 1.5 1.5 1.5 L = 130 mm m/s 1.5 1.5 1.5 1.5 1 2 LS(M)-XRR for angle of actuation 2 LS(M)-XL for angle of actuation = 30/45 m/s 1 1 1 LS(M)-XLA for angle of actuation = 30/45 m/s 1 1 1 1 LS(M)-XP for angle of actuation = 0/30 m/s 1/1 1/1 1/1 1/1 kV 8 8 8 2 2 2 2 2 2 2 2 Electromagnetic Compatibility (EMC) Electrostatic discharge (IEC/EN 61000-4-2, Level 3 ESD) Air discharge Contact discharge kV 4 4 4 V/m 10 10 10 Supply cables kV 2 2 2 Signal lines kV 2 2 2 High-energy pulses (surge) (IEC/EN 61000-4-5) kV 0.5 0.5 0.5 Immunity to line-conducted interference to (IEC/EN 610000-4-6) V 10 10 10 Electromagnetic fields (IEC/EN 61000-403, RFI) Burst pulses (IEC/EN 61000-4-4, Level 3) 2 2 2 V8-T2-36 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches LS-Titan Miniature DIN Switches 2.3 Contact Travel Diagrams 2 LSE Contact Travel LSE-11 = contact closed Description Q1 2 LSE-02 Q2 Q1 2 Q2 = contact open 2 Basic Units 0 0.5 0 0.5 5.5 6.1 Q1 2 5.5 6.1 Q1 Q2 2 Q2 default=3.0 default=3.0 2 Operating Heads 2 Roller plunger LS-XP LSM-XP 0 0.5 0 0.5 5.5 6.1 Q1 5.5 6.1 2 Q1 Q2 Q2 default=3.0 2 default=3.0 2 Roller lever LS-XL LSM-XL LS-XL LS-XLB 0 0.5 9.0 9.6 0 0.5 Q1 Q1 Q2 Q2 default=4.4 9.0 9.6 2 2 default=4.4 2 Angled roller lever LS-XLA LSM-XLA 0 0.5 10 10.8 0 0.5 Q1 Q1 Q2 Q2 default=5.0 10 10.8 2 2 default=5.0 2 Rotary lever LS-XRL LSM-XRL 0 5 60 65 0 5 Q1 Q1 Q2 Q2 default=30 60 65 2 2 default=30 2 Adjustable roller lever LS-XRLA LSM-XRLA LS-XRLA30 LS-XRLA40 LS-XRLA40R 0 5 60 65 0 5 Q1 Q1 Q2 Q2 default=30 60 65 2 2 default=30 2 Actuating rod LS-XRR LSM-XRR LS-XRRM LSM-XRRM 0 5 60 65 0 5 60 65 2 Q1 Q1 Q2 2 Q2 default=30 default=30 2 Spring rod LS-XS LSM-XS 0 3 23 26 0 3 2 23 26 Q1 Q1 Q2 2 Q2 default=13 default=13 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-37 2.3 2 Contact Travel NO 13 14 21 24 23 3.0 6.1 0 3.0 0 6.1 11-12 NC 21-22 13-14 21-22 NC 13-14 23-24 6.1 NO NO 21-22 3.0 2.1 2.1 ZW = 4.5 mm Zw = 4.5 mm Roller plunger LS-XP, LSM-XP 0 3.0 6.1 0 3.0 0 6.1 11-12 NC 21-22 13-14 21-22 NC 13-14 23-24 Zw = 4.5 mm 6.1 NO NO 21-22 3.0 2.1 2.1 ZW = 4.5 mm 13-14 1.6 Zw = 4.5 mm Roller lever LS-XL, LSM-XL 0 4.4 9.6 0 11-12 NC 21-22 21-22 NC 13-14 Zw = 6.9 mm 4.4 9.6 0 9.6 NO NO 23-24 21-22 4.4 3.3 13-14 3.3 13-14 2.3 Zw = 8.7 mm Roller lever, short LS-XLS 2 0 3.3 0 6.9 3.3 0 6.9 11-12 NC 21-22 13-14 21-22 NC 13-14 23-24 Zw = 5.0 mm 2 2 22 Operating Heads 2 2 NO NC 13 14 21 1.6 2 2 22 LS-20A, LS-S20A, LSM-20A 13-14 2 2 NO NC 11 Zw = 4.5 mm 2 2 NC 12 0 2 2 = contact open LS-11S, LS-S11S, LSM-11S Basic Units 2 2 LS-02, LS-S02, LSM-02 = contact closed Description 2 2 LS-Titan Miniature DIN Switches LS and LSM 2 2 Limit Switches 6.9 NO NO 2.2 21-22 3.3 2.2 13-14 1.7 Zw = 6.2 mm Roller lever, large LS-XLB 2 0 0 13.4 6.3 13.4 21-22 13-14 21-22 NC 13-14 23-24 6.3 4.3 3.2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Zw = 12.0 mm 13.4 NO NO 4.3 21-22 13-14 V8-T2-38 0 NC Zw = 9.6 mm 2 6.3 11-12 2.3 Limit Switches LS-Titan Miniature DIN Switches LS and LSM, continued Contact Travel LS-02, LS-S02, LSM-02 = contact closed Description = contact open NC NO NC 11 12 LS-11S, LS-S11S, LSM-11S 22 NO NC 13 14 21 22 2 LS-20A, LS-S20A, LSM-20A 2 NO 13 14 21 24 23 2 Operating Heads Angled roller lever LS-XLA, LSM-XLA 0 5.0 11-12 21-22 Zw = 7.6 mm 0 10.8 NC 21-22 NC 13-14 5.0 10.8 0 10.6 13-14 NO 23-24 NO 21-22 5.0 3.6 3.6 13-14 2.4 Adjustable roller lever LS-XRLA, LSM-XRLA LS-XRLA30, LS-XRLA40 LS-XRLA40R 0 30 11-12 NC NC 21-22 Zw = 47 0 65 30 65 21-22 13-14 0 22 65 13-14 NO 23-24 NO 21-22 30 22 13-14 Actuating rod 15 2 2 2 Zw = 9.7 mm Rotary lever LS-XRL, LSM-XRL 2 2 2 2 2 Zw = 60 LS-XRR, LSM-XRR LS-XRRM, LSM-XRRM 2 Spring rod LS-XS, LSM-XS 0 13 11-12 21-22 13 26 0 13 0 26 NC 21-22 13-14 NC 13-14 23-24 21-22 9 26 NO NO 9 2 2 2 13-14 7 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-39 2.3 2 Limit Switches LS-Titan Miniature DIN Switches Dimensions Approximate Dimensions in Inches (mm) 2 Position Switches 2 LS-_, LSM-_, LSE-_ 0.50 (12.7) 2 0.87 (22.0) 2 2 2 2 0.32 (8.2) 0.08 (1.95) 0.83 (21.0) 0.21 2.17 (5.3) (55.0) 0.79 (20.0) 0.29 (7.3) 2.99 (76.0) 3 1 0.17 (4.3) 1.97 (50.0) 2 0.17 (4.3) 2 2 0.98 (25.0) 0.46 (11.7) 1.22 (31.0) 0.55 (14.0) M20 Thread o 0.16 (4.0) 1.32 (33.5) 2 2 2 2 30 0.32 (8.2) 2 2 2 0.50 (12.7) 30 0.46 (11.7) 0.83 (21.0) 26 0.59 (15.0) 2 2 o0.23 (5.8) 0.79 (20.0) 2 2 LS(M)-_/S LS-_, LSM-_, LSE-_ 4.96 (126.0) LS(M)-_/P 0.79 (20.0) 0.35 (9.0) 30 1.04 (26.5) 30 0.50 (12.7) 0.10 (2.5) 1.00 (25.4) 2 2 2 2 Notes 1 Tightening torque of cover screws: 0.8 Nm 0.2 Nm. 2 Only with LS (insulated version). 3 Fixing screws 2 x M4 30 MA = 1.5 Nm 2 2 2 2 2 V8-T2-40 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 26 0.50 (12.7) 2.3 Limit Switches LS-Titan Miniature DIN Switches Approximate Dimensions in Inches (mm) Rotary Lever Roller Lever, Short LS(M)-_/RL LS(M)-_/LS 1.82 (46.2) 1.59 (40.5) 0.79 (20.0) 65 30 0.94 (23.9) 65 1.06 (27.0) 1.57 (40.0) 2 o0.51 (13.0) 30 0.79 (20.0) 0.20 (5.0) 1.44 (36.5) 1.17 (29.7) 30 2 0.50 (12.7) 2 0.20 (5.0) 2 1.18 (30.0) 2 2 o0.55 (14.0) 0.83 (21.0) 2 2 Roller Lever Adjustable Roller Lever LS(M)-_/L LS(M)-_/RLA 0.13 (3.4) 0.79 (20.0) 2 2 0.79 (20.0) 0.50 (12.7) 0.20 (5.0) 30 0.51 (13.0) 30 30 5 Adjustable 0.75 (19.0) to 3.00 (76.0) 2 2 o0.71-1.57 (18.0-40.0) 65 6 1.35 1.22 (31.0) (34.4) 2 2.14 (54.5) 1.83 (46.4) 1.27 (32.2) 2 0.39 (10.0) 2 1.75 (44.5) 2 Roller Lever, Large LS(M)-_/LB 1 0.80 (20.4) 0.79 (20.0) 1.54 (39.0) 30 2 0.50 (12.7) o0.87 (22.0) 0.22 (5.6) 2 Angled Roller Lever 2 LS(M)-_/XLA 2.06 (52.3) 1.63 (41.3) 2 0.51 (13.0) 1.31 (33.2) 0.50 (12.7) 2 0.20 (5.0) 2 1.43 (36.3) 2 30 0.79 (20.0) 2 2 0.31 (8.0) 2 Notes 1 Tightening torque of cover screws: 0.8 Nm 0.2 Nm. 2 Setting range of 54.5 to 97. 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-41 2.3 2 2 Limit Switches LS-Titan Miniature DIN Switches Approximate Dimensions in Inches (mm) Actuating Rod LS(M)-_/RR 2 LS(M)-_/OR o0.24 (6.0) 2 2 3 4 2 2 2 o 0.26 (6.5) 1 65 o 0.16 (4.0) 65 4.33 (110.0) 2 2 2 1.69 (43.0) 1.81 (46.0) 2 2 2 2 2 2 2 0.50 (12.7) Notes 1 LS_/RR 150 LS_/RRM 210 2 Approach direction, vertical. 3 Guide is done by customer, not included. 4 Maximum push-through. 2 2 2 2 2 2 2 2 2 2 2 2 2 V8-T2-42 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 1.22 (31.0) 0.24 (6.1) Limit Switches E49 Mini Metal Switches 2.4 Contents E49 Mini Metal Switches Description Page E49 Mini Metal Switches Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-44 V8-T2-46 V8-T2-47 Drawings Online 2 2 2 2 2 2 2 2 2 2 2 E49 Mini Metal Switches Product Description Features E49 Mini Metal Limit Switches from Eaton's electrical sector are designed small and tough, with machinery OEMs in mind. The small size, metal body and mechanical life make this product perfect for switching applications in packaging, material handling, elevators and lifts, electronic assembly equipment, injection molding machinery, and auto-vending machines. The E49 Mini Metal is the ideal switch for those who need a costeffective, compact solution, but don't want to sacrifice durability in the process. Standards and Certifications Long life--rated for 10 million operations Pre-wired units with custom cable lengths available for high volume customers "Fingerproof" terminals protect against accidental shock Double-spring mechanism for contact reliability Grounding terminal included Captive screws on enclosure cover make wiring hassle-free SPDT double break UL Recognized CE RoHS 2 DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-43 2 2 2.4 2 E49 Mini Metal Switches Product Selection 2 E49 Mini Metal Switches 2 2 Limit Switches Operating Head Type Travel to Operate Contacts Side Rotary Lever Side Rotary Lever 2 20 Assembled Unit (Switch Body and Head) 1NO-1NC Contacts Travel to Reset Contacts Total Travel Force to Operate Contacts Minimum Return Force 12 70 750g 100g E49G31AP3 12 70 750g 100g E49G31UP3 0.04 in (1 mm) 0.22 in (5.5 mm) 900g 150g E49G31BP3 0.04 in (1 mm) 0.22 in (5.5 mm) 900g 150g E49G31CP3 0.22 in (5.5 mm) 900g 150g E49G31C1P3 70 750g 100g E49G31DP3 Catalog Number 2 2 2 Adjustable Side Rotary Lever Adjustable Side Rotary Lever Top Pushbutton Top Pushbutton 2 20 2 2 2 0.06 in (1.5 mm) 2 2 2 Top Push Roller 2 Top Push Roller 0.06 in (1.5 mm) 2 2 2 Top Push Roller (90 Roller) Top Push Roller (90 Roller) Adjustable Rod Lever Adjustable Rod Lever 2 0.06 in (1.5 mm) 0.04 in (1 mm) 2 2 2 20 2 12 2 2 2 2 2 2 V8-T2-44 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E49 Mini Metal Switches 2.4 E49 Mini Metal Switches, continued Operating Head Type Travel to Operate Contacts Wobble Stick (Nylon Coil) Wobble Stick (Nylon Coil) 1.18 in (30 mm) Travel to Reset Contacts -- Total Travel Force to Operate Contacts -- 150g 2 Assembled Unit (Switch Body and Head) 1NO-1NC Contacts 2 Catalog Number 2 2 E49G31NP3 2 2 2 Wobble Stick (Metal Coil) 2 Wobble Stick (Metal Coil) 1.18 in (30 mm) -- -- 150g 2 E49G31VP3 2 2 2 Wobble Stick (Metal Rod) 2 Wobble Stick (Metal Rod) 1.18 in (30 mm) -- -- 150g 2 E49G31MP3 2 2 2 2 Wobble Stick (Whisker) 2 Wobble Stick (Whisker) 1.18 in (30 mm) -- -- 150g E49G31XM3 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-45 2.4 Limit Switches E49 Mini Metal Switches 2 Technical Data and Specifications 2 E49 Mini Metal Switches Description Specification 2 Operating speed 0.19 in (5 mm) to 19.7 in/s (50 cm/s) Operating frequency 120 operations/min 2 Contact resistance 25M ohms (initial) 2 Insulation resistance 100M ohms min (at 500 Vdc) Dielectric strength 1000 Vac, 50/60 Hz for one minute between non-continuous terminals 2 1500 Vac, 50/60 Hz for one minute between current-carrying and non-current-carrying parts and between each terminal and ground 2 Vibration 10 to 55 Hz, 1.5 mm double amplitude Shock Approx. 300 m/s2 (approx. 30Gs) 2 Ambient operating temperature 23 to 149F (-5 to 65C) Humidity 95% RH max. 2 Service life 2 2 Mechanical: 10,000,000 operations min. Electrical: 500,000 operations min. Weight Approx. 130 to 190g Degree of protection IEC: IP65 Material of construction Shaft: stainless SUS303 Arm: stainless SUS304 Head and body: zinc alloy Terminal cover: PC/ABS plastic Rubber grommet: NBR rubber 2 2 2 2 Maximum Ampere Ratings Inductive Load (A) 1 Non-Inductive Load (A) Rated Voltage Resistive Load Lamp Load 2 Inductive Load Motor Load NC NO NC NO NC NO NC 125 Vac 5 5 1.5 0.7 3 3 2 1 250 Vac 5 5 1 0.5 3 3 1.5 0.8 2 8 Vdc 5 5 3 3 5 4 3 3 14 Vdc 5 5 3 3 4 4 3 3 2 30 Vdc 5 5 3 3 4 4 3 3 125 Vdc 0.4 0.4 -- -- -- -- -- -- 2 250 Vdc 0.2 0.2 -- -- -- -- -- -- 2 Terminal Configuration 2 NO (4) NO (3) 2 NC (1) NC (2) 2 2 2 2 Notes 1 Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 msec. max. (DC). 2 Lamp load has an inrush current of ten times the steady-state current, while motor load has an inrush current of six times the steady-state current. 2 2 2 2 2 V8-T2-46 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com NO 2.4 Limit Switches E49 Mini Metal Switches Dimensions 2 Approximate Dimensions in Inches (mm) E49G31AP3 2 E49G31CP3 1.62 (41) 1.43 (28) 0.70 x 0.28 (18 x 7) Dia. PT 20 Max. 0.8 (20) 1.18 (30) R M3 x 6 0.49 (12) 0.16 (4.1) Dia. M4 2.2 (56) M3 x 23 0.50 x 0.15 (13 x 4) Dia. 0.59 (15) 0.16 (4.1) Dia. 2.52 (64) M3 x 23 2 1.5 (38) M3 x 6 0.73 (18) 2 2 2.52 (64) 2.2 (56) 2 M5 (P=0.8) M5 (P=0.8) 2 0.55 (14) 0.55 (14) 0.30 (7) 0.83 (21) 1.1 (28) 0.30 (7) 0.83 (21) 1.1 (28) 0.6 (15) 0.98 (25) E49G31BP3 2 0.6 (15) 0.98 (25) 2 2 E49G31DP3 0.12 (3) M3 x 6 0.39 (10) 0.22 (6) 0.10 (3) Dia. 1.06 (27) 0.16 (4.1) Dia. 2.52 (64) 2.2 (56) M3 x 23 0.55 (14) 0.30 (7) 0.6 (15) 0.98 (25) 2 0.8 (20) 2 0.49 (12) 0.73 (18) 2.2 (56) 2.52 (64) M6 0.16 (4.1) Dia. 2 2 M5 (P=0.8) 0.83 (21) 1.1 (28) 1.77 (45) 1.41 (36) 1.18~4.65 (30~118) M4 M3 x 6 M3 x 23 2 2 M5 (P=0.8) 0.55 (14) 0.30 (7) 0.83 (21) 1.1 (28) E49G31C1P3 0.50 x 0.15 (13 x 4) Dia. 2 0.39 (10) 2 0.6 (15) 2 0.98 (25) 2 E49G31MP3 0.39 (10) 0.11 (3) Dia. 1.5 (38) M3 x 6 2 1.65 (42) 0.16 (4.1) Dia. 3.94 (100) 2.52 (64) 2.2 (56) M3 x 23 2 0.40 (10) 0.59 (15) 2 0.23 (6) Dia. 2 M3 x 6 2 0.16 (4.1) Dia. M5 (P=0.8) 2 0.55 (14) 0.83 (21) 1.1 (28) 0.30 (7) 0.6 (15) 0.98 (25) 2.52 (64) 2.2 (56) M3 x 23 2 M5 (P=0.8) 0.83 (21) 1.1 (28) 0.30 (7) 0.55 (14) 2 0.6 (15) 2 0.98 (25) Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2 V8-T2-47 2.4 2 2 Limit Switches E49 Mini Metal Switches Approximate Dimensions in Inches (mm) E49G31NP3 E49G31VP3 2 1.65 (42) 2 3.94 (100) 2 2 2 M3 x 6 2 M5 (P=0.8) 0.55 (14) 0.30 (7) M3 x 6 0.16 (4.1) Dia. 2 1.89 (48) 1.69 (43) 1.30 (33) 1.10 (28) L= 1.18~2.75 (30~70) 0.40 (10) 2.05 (52) 3.94 (100) 0.8 (20) M4 0.73 (18) M6 0.49 (12) 2.2 (56) M3 x 23 0.55 (14) 2 M3 x 6 0.30 (7) M5 (P=0.8) 0.6 (15) 0.98 (25) 2 2 2 2 2 2 2 2 V8-T2-48 2.52 (64) 2.2 (56) M3 x 23 0.83 (21) 1.1 (28) 0.04 (1) Dia. 0.16 (4.1) Dia. 2.52 (64) 0.08 (2) M5 (P=0.8) 2 0.6 (15) 0.98 (25) E49G31XM3 2 2 0.6 (15) 0.98 (25) 0.70 x 0.28 (18 x 7) Dia. 2 0.30 (7) 0.83 (21) 1.1 (28) E49G31UP3 2 2.52 (64) 2.2 (56) M3 x 23 M5 (P=0.8) 0.83 (21) 1.1 (28) 2 2 2.52 (64) 2.2 (56) 0.55 (14) 2 2 0.16 (4.1) Dia. 0.16 (4.1) Dia. M3 x 23 2 3.94 (100) 0.23 (6) Dia. M3 x 6 2 2 0.40 (10) 0.40 (10) 0.11 (3) Dia. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 0.55 (14) 0.83 (21) 1.1 (28) 0.30 (7) 0.6 (15) 0.98 (25) Limit Switches E49 Compact Metal Switches 2.5 Contents E49 Compact Metal Switches Description Page E49 Compact Metal Switches Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-50 V8-T2-52 V8-T2-53 Drawings Online 2 2 2 2 2 2 2 2 2 2 2 E49 Compact Metal Switches Product Description Features E49 Compact Metal Switches by Eaton's electrical sector are designed with high mechanical strength for robust environments. The rugged aluminum die cast construction provides reliable, oil-tight, waterproof and dustproof sealing for a variety of applications. Snap action 1NO-1NC contacts provide flexibility in design. Standards and Certifications Rigid die cast switch housing High mechanical strength Oil-tight, waterproof and dustproof construction cULus NEMA A600 (AC-15) NEMA R300 (DC-13) IP67 RoHS 2 DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-49 2 2 2.5 2 E49 Compact Metal Switches Product Selection 2 E49 Compact Metal Switches 2 2 Limit Switches Operating Head Type Travel to Operate Contacts Roller Lever Roller Lever 2 20 Assembled Unit (Switch Body and Head) 1NO-1NC Contacts Travel to Reset Contacts Total Travel Force to Operate Contacts (Maximum) Minimum Return Force 12 50 2.99 lbs 0.50 lb E49M11AP1 0.04 in (1.0 mm) -- 6.02 lbs 2.01 lbs E49M11BP1 0.04 in (1.0 mm) 0.25 in (6.5 mm) 6.02 lbs 2.01 lbs E49M11CP1 (as pictured) Catalog Number 2 2 2 2 Top Push Top Push 0.067 in (1.7 mm) 2 2 2 2 Top Push Roller Top Push Roller 0.067 in (1.7 mm) 2 2 E49M11CP2 90 Cross Roller 2 2 2 Rod Lever Rod Lever 20 12 50 0.31 lb 2 2 2 2 2 2 2 2 2 2 2 2 V8-T2-50 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 0.06 lb E49M11DP1 2.5 Limit Switches E49 Compact Metal Switches E49 Compact Metal Switches, continued Operating Head Type Travel to Operate Contacts Adjustable Roller Lever Adjustable Roller Lever 20 Travel to Reset Contacts 12 Total Travel Force to Operate Contacts (Maximum) Minimum Return Force 50 2.99 lbs 0.50 lb Assembled Unit (Switch Body and Head) 1NO-1NC Contacts Catalog Number 2 2 2 2 E49M11UP1 2 2 2 Wobble 2 Wobble 1.10 in (28 mm) N/A N/A 0.33 lb N/A E49M11VP1 2 2 2 2 2 Cat Whisker Cat Whisker 1.10 in (28 mm) N/A N/A 0.064 lb N/A 2 E49M11XM1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-51 2.5 Limit Switches E49 Compact Metal Switches 2 Technical Data and Specifications 2 E49 Compact Metal Switches Description Specification 2 Operating speed 1 mm to 2m/sec Operating frequency Mechanically: 120 operations/min.; Electronically: 30 operations/min. 2 Contact resistance 15M ohms max. (initial) Insulation resistance 100M ohms min. (at 500 Vdc) Dielectric strength 1000 Vac, 50/60 Hz for 1 minute between non-continuous terminals; 2200 Vac, 50/60 Hz for 1 minute between each terminal and non-current carrying metal part and between each terminal and ground Vibration Malfunction durability: approx. 1000 m/sec2 (approx. 100 Gs); Malfunction durability: approx. 300/sec2 (30 Gs) Ambient operating temperature 14 to 176F (-10 to 80C) Humidity 95% RH max. Service life Mechanically: 15,000,000 operations/minute; Electronically: 500,000 operations/minute 2 2 2 2 2 2 2 Maximum Ampere Ratings--Isolated Contacts, No Polarity Restriction NEMA A600 (AC-15) 50 or 60 Hz NEMA R300 (DC-13) 2 Rated Voltage Current Continuous Make Break Make 2 24 Vac 10A 60A 6.0A 7200 VA 120 Vac 10A 60A 6.0A 2 250 Vac 10A 30A 480 Vac 10A 15A 600 Vac 10A 12A 2 Voltamperes Break Rated Voltage Current 720 VA 24 Vdc 1.5A 7200 VA 720 VA 120 Vdc 0.22A 3.0A 7200 VA 720 VA 250 Vdc 0.11A 1.5A 7200 VA 720 VA 1.2A 7200 VA 720 VA 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V8-T2-52 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E49 Compact Metal Switches 2.5 Dimensions 2 Approximate Dimensions in Inches (mm) Switch Body with E49M11BP1 0.35 (9.0) Dia. 2 E49M11UP1 0.69 (17.5) Dia. 0.50 (12.7) 2.64 (67.0) 2.36 (60.0) 0.28 (7.0) 2 2 0.78 (19.9) 4-M6 Thread 2.31 (58.7) 0.20 (5.0) 1.58 (40.0) 0.59 (15.1) 0.19 (4.9) 1.19 (30.2) 2.71 (68.7) 1.63 (41.5) 0.98 (25.0) to 3.51 (89.0) 0.58 (14.7) 2 2 0.85 (21.6) 1.15 (29.2) 1.38 (35.0) E49M11CP1/E49M11CP2 2 2 E49M11VP1 0.50 (12.7) 0.67 (17.0) Dia. 2 1.00 (25.4) 0.26 (6.5) Dia. 0.20 (5.0) 2 0.52 (13.1) 2 1.10 (28.0) 2 5.51 (140.0) 2 2 E49M11DP1 2 E49M11XM1 0.35 (9.0) 0.12 (3.0) Dia. 2.17 (55.0) 1.81 (46.0) 2 2.03 (51.5) 2 5.51 (140.0) 0.98 (25.0) to 5.51 (140.0) 2 2 1.00 (25.4) 0.58 (14.7) 2 2 2 E49M11AP1 0.69 (17.5) Dia. 0.28 (7.0) 2 2.32 (59.0) 2.09 (53.0) 2 1.84 (46.6) 0.58 (14.7) 2 1.00 (25.4) 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-53 2.6 2 Limit Switches E50 Heavy-Duty Plug-In Switches Contents E50 Heavy-Duty Plug-In Switches Description 2 2 2 2 2 2 2 2 2 E50 Heavy-Duty Plug-In Switches 2 Product Description Features E50 Modular Plug-In Limit Switch Components from Eaton's electrical sector are the industry standard with versatility of design and high reliability for low maintenance, installation and inventory costs. Standard Viton gaskets, seals and boots and a zinc die cast enclosure provide exceptional chemical resistance to the common coolants, cleansing agents, and hydraulic fluids found in machine tool, automotive, waste water treatment and other heavyduty industrial applications. Mounting dimensions accommodate both U.S. and DIN standards for easy retrofit installations. Super bright 24-120 Vac/dc LED indicating light versions simplify setup and troubleshooting operations. 2 2 2 2 2 2 2 2 2 2 2 V8-T2-55 V8-T2-58 V8-T2-59 V8-T2-60 V8-T2-61 V8-T2-62 V8-T2-62 V8-T2-64 V8-T2-65 V8-T2-65 V8-T2-66 Drawings Online 2 2 Page E50 Heavy-Duty Plug-In Switches Product Selection Assembled Switches--Standard . . . . . . . . . Assembled Switches--Special Purpose . . . Operating Heads . . . . . . . . . . . . . . . . . . . . . Switch Bodies . . . . . . . . . . . . . . . . . . . . . . . Receptacles . . . . . . . . . . . . . . . . . . . . . . . . Compatible Connector Cables . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Circuit Diagrams . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Modular, plug-in components (head, body and receptacle) provide application flexibility, reduced inventory and less downtime Manufactured to take the physical and environmental abuse (including cutting fluids and chemicals) of harsh industrial environments Chemical resistant Viton gaskets, seals and boots are standard, and so are captive, posi-drive screws The switches have terminal identification on the nameplate for a visual wiring checkout without guesswork. Heads and switch bodies can be replaced without rewiring Standards and Certifications E50 devices can be ordered in separate components or as complete assembled switches 600V rating, ridge-topped contacts and wiping action assure continuity even to logic level circuits Keyed, four direction head positioning Standard 5 pre-travel and 90 total travel 24-120 Vac/dc LED and 120 Vac neon indicating lights available Rotary heads are field convertible CW, CCW, or both, without special tools Epoxy filled, pin connector or pigtail pin connector receptacles available 2 2 2 UL Listed CSA Certified IEC.947.5.1 TUV--E9271605E02 CE (where shown) DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com V8-T2-54 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.6 Limit Switches E50 Heavy-Duty Plug-In Switches Product Selection 2 Assembled Switches--Standard Assembled Switch 2 E50 Heavy-Duty Plug-In Switches, Assembled--Standard 2 2 2 Single-Pole (5 Terminal Receptacle) Indicating Light: None None LED (24-120 Vac/dc) Switch Body: E50SA 1NO-1NC E50SAL 1NO-1NC E50SAN 1NO-1NC E50SB 2NO-2NC E50SBL 2NO-2NC E50SBN 2NO-2NC E50SCL 1NO-2NC -- Receptacle: 1 E50RA E50RA E50RA E50RB E50RB E50RB E50RB E50RB Neon (120 Vac) Assembled Switch (Head + Receptacle + Body) Catalog Number Operating Head Type 2 Description Side Rotary 2 Two-Pole (9 Terminal Receptacle) LED (24-120 Vac/dc) Neon (120 Vac) LED (24-120 Vac/dc) Neon (120 Vac) 2 2 2 Assembled Switch (Head + Receptacle + Body) Catalog Number Side Rotary (requires an operating lever, see Page V8-T2-80) E50AR1 E50ALR1 E50ANR1 E50BR1 E50BLR1 E50BNR1 -- -- Low force spring return--E50DL1 3 E50AL1 E50ALL1 E50ANL1 E50BL1 E50BLL1 E50BNL1 -- -- 2 E50ALM1 E50ANM1 E50BM1 E50BLM1 E50BNM1 -- -- 2 E50ALS1 E50ANS1 E50BS1 E50BLS1 E50BNS1 E50CLS1 -- Maintained twoE50AM1 position--E50DM1 Spring return-- E50DS1 2 2 Side Pushbutton Spring Return 2 Standard spring return--E50DR1 3 E50AS1 2 2 Adjustable Spring Return Adjustable spring return--E50DS2 E50AS2 E50ALS2 E50ANS2 E50BS2 E50BLS2 E50BNS2 E50BLS2 E50CNS2 2 2 2 2 Circuit Diagrams, see Page V8-T2-65. Notes 1 Connection options (add the code suffix from the table below to the end of the catalog number): Code Suffix Single-pole (5-pin mini-connector) CSMS5D5CY1602 P5 5 Two-pole (9-pin mini-connector) CSMS9D9CY1602 P9 5 Option Mini-connector 4 (with epoxy filled receptacle) Micro-connector 4 (with epoxy filled receptacle) 3 4 5 2 2 2 5 Single-pole (5-pin micro-connector) CSDS5A5CY2202 A5 8 ft cable length -- S 12 ft cable length -- S12 20 ft cable length -- S20 Manifold mount (rear wiring entrance) -- M 20 mm conduit entrance -- 20 Cable connection (with epoxy filled receptacle) 2 2 Mating Cordset Catalog Number 2 2 2 For operating head specifications, see Page V8-T2-59. CW (clockwise) and CCW (counterclockwise) operation, easily convertible to CW only or CCW only operation. For a full selection of cable connectors, see Tab 10, section 10.1. Refer to Page V8-T2-65 for wiring diagrams. 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-55 2.6 2 Assembled Switch Limit Switches E50 Heavy-Duty Plug-In Switches E50 Heavy-Duty Plug-In Switches, Assembled--Standard, continued 2 2 2 Single-Pole (5 Terminal Receptacle) 2 2 2 2 Indicating Light: None Switch Body: E50SA 1NO-1NC E50SAL 1NO-1NC E50SAN 1NO-1NC E50SB 2NO-2NC E50SBL 2NO-2NC E50SBN 2NO-2NC E50SCL 1NO-2NC -- Receptacle: 1 E50RA E50RA E50RA E50RB E50RB E50RB E50RB E50RB Operating Head Type 2 Description Side Push Roller Neon (120 Vac) None LED (24-120 Vac/dc) Neon (120 Vac) LED (24-120 Vac/dc) Neon (120 Vac) Assembled Switch (Head + Receptacle + Body) Catalog Number Assembled Switch (Head + Receptacle + Body) Catalog Number E50AS3 E50ALS3 E50ANS3 E50BS3 E50BLS3 E50BNS3 E50BLS3 -- E50AH1 E50ALH1 E50ANH1 E50BH1 E50BLH1 E50BNH1 E50BLH1 -- Side Push Roller Spring return-- E50DS3 3 2 Two-Pole (9 Terminal Receptacle) LED (24-120 Vac/dc) 2 2 Side Pushbutton Side Pushbutton Maintained-- E50DH1 2 2 2 Top Pushbutton Spring Return Spring return-- E50DT1 E50AT1 E50ALT1 E50ANT1 E50BT1 E50BLT1 E50BNT1 E50CLT1 E50BNT1 Adjustable Spring Return Adjustable spring return--E50DT2 E50AT2 E50ALT2 E50ANT2 E50BT2 E50BLT2 E50BNT2 -- -- 2 2 2 2 2 2 Circuit Diagrams, see Page V8-T2-65. 2 Notes 1 Connection options (add the code suffix from the table below to the end of the catalog number): 2 Mating Cordset Catalog Number Code Suffix Single-pole (5-pin mini-connector) CSMS5D5CY1602 P5 5 Two-pole (9-pin mini-connector) CSMS9D9CY1602 P9 5 Micro-connector 4 (with epoxy filled receptacle) Single-pole (5-pin micro-connector) CSDS5A5CY2202 A5 5 Cable connection (with epoxy filled receptacle) 8 ft cable length -- S 12 ft cable length -- S12 20 ft cable length -- S20 Manifold mount (rear wiring entrance) -- M 20 mm conduit entrance -- 20 Option 2 Mini-connector 2 2 2 2 2 2 3 4 2 5 4 (with epoxy filled receptacle) For operating head specifications, see Page V8-T2-59. Roller can be converted in the field between horizontal and vertical. For a full selection of cable connectors, see Tab 10, section 10.1. Refer to Page V8-T2-65 for wiring diagrams. 2 V8-T2-56 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.6 Limit Switches E50 Heavy-Duty Plug-In Switches Assembled Switch E50 Heavy-Duty Plug-In Switches, Assembled--Standard, continued 2 2 2 Single-Pole (5 Terminal Receptacle) Indicating Light: None LED (24-120 Vac/dc) Neon (120 Vac) None LED (24-120 Vac/dc) Neon (120 Vac) LED (24-120 Vac/dc) Neon (120 Vac) 2 Switch Body: E50SA 1NO-1NC E50SAL 1NO-1NC E50SAN 1NO-1NC E50SB 2NO-2NC E50SBL 2NO-2NC E50SBN 2NO-2NC E50SCL 1NO-2NC -- Receptacle: 1 E50RA E50RA E50RA E50RB E50RB E50RB E50RB E50RB 2 -- -- Operating Head Type 2 Description Top Push Roller 2 Two-Pole (9 Terminal Receptacle) Assembled Switch (Head + Receptacle + Body) Catalog Number Assembled Switch (Head + Receptacle + Body) Catalog Number E50AT3 E50BT3 2 Top Push Roller Spring return E50DT3 3 2 E50ALT3 E50ANT3 E50BLT3 E50BNT3 2 2 Wobble Head, Spring Return 2 Wobble Head, Spring Return (requires a wobble operator, see Page V8-T2-80) Standard duty-- E50DW1 E50AW1 E50ALW1 E50ANW1 E50BW1 E50BLW1 E50BNW1 EB50BLW1 -- Heavy-duty high strength steel-- E50DW2 E50AW2 E50ALW2 E50ANW2 E50BW2 E50BLW2 E50BNW2 E50CLW2 E50BNW2 2 2 2 Circuit Diagrams, see Page V8-T2-65. 2 Notes 1 Connection options (add the code suffix from the table below to the end of the catalog number): 2 Option Mini-connector 4 (with epoxy filled receptacle) 2 3 4 5 Mating Cordset Catalog Number Code Suffix Single-pole (5-pin mini-connector) CSMS5D5CY1602 P5 5 Two-pole (9-pin mini-connector) CSMS9D9CY1602 P9 5 Micro-connector 4 (with epoxy filled receptacle) Single-pole (5-pin micro-connector) CSDS5A5CY2202 A5 5 Cable connection (with epoxy filled receptacle) 8 ft cable length -- S 12 ft cable length -- S12 20 ft cable length -- S20 Manifold mount (rear wiring entrance) -- M 20 mm Conduit Entrance -- 20 2 2 2 2 2 2 For operating head specifications, see Page V8-T2-59. Roller can be converted in the field between horizontal and vertical. For a full selection of cable connectors, see Tab 10, section 10.1. Refer to Page V8-T2-65 for wiring diagrams. 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-57 2.6 2 E50 Heavy-Duty Plug-In Switches Assembled Switches--Special Purpose E50 Heavy-Duty Plug-In Switches, Assembled--Special Purpose 2 2 Limit Switches Operating Data-- Nominal Switches Neutral Position Assembled Switch Catalog Number Switch Body Only Catalog Number Receptacle Only Catalog Number Operating Head Only Catalog Number E50SN E50RB E50DN1 1 -- Neutral Position (requires an operating lever, see Page V8-T2-80) 2 5 Travel 5 Travel; stainless steel shaft E50NN1SPL -- -- 2 15 Travel E50NN2 E50SN E50RB E50DN2 1 Travel to operate contacts: Travel to reset contacts: Total travel: Force to operate contacts: Minimum return force: Operating temperature: 5 or 15 3 2 90 1.8 in-lbs 2.5 in-oz 14 to 200F (-10 to 94C) 5 or 15 3 2 90 1.8 in-lbs 2.5 in-oz 14 to 200F (-10 to 94C) 5 or 15 3 2 90 1.8 in-lbs 2.5 in-oz 14 to 200F (-10 to 94C) 5 or 15 3 2 90 1.8 in-lbs 2.5 in-oz 14 to 200F (-10 to 94C) 2 2 2 Two-Step 2 2 Two-Step CW, CCW, or both, Convertible (requires an operating lever, see Page V8-T2-80) E50TD1 E50ST E50RB E50DD1 Travel to operate contacts: 1st step 10; 2nd step 20 4 each 90 3 in-lbs 4.5 in-oz CW or CCW: 14 to 250F (-10 to 121C) CW and CCW: 14 to 200F (-10 to 94C) 1st step 10; 2nd step 20 4 each 90 3 in-lbs 4.5 in-oz CW or CCW: 14 to 250F (-10 to 121C) CW and CCW: 14 to 200F (-10 to 94C) 1st step 10; 2nd step 20 4 each 90 3 in-lbs 4.5 in-oz CW or CCW: 14 to 250F (-10 to 121C) CW and CCW: 14 to 200F (-10 to 94C) 1st step 10; 2nd step 20 4 each 90 3 in-lbs 4.5 in-oz CW or CCW: 14 to 250F (-10 to 121C) CW and CCW: 14 to 200F (-10 to 94C) 2 2 Gravity Return 2 2 2 2 2 2 -- Travel to reset contacts: Total travel: Force to operate contacts: Minimum return force: Operating temperature: 2 E50NN1 1 Gravity Return (requires E50KL220, E50KL226 or equivalent operating lever, see Page V8-T2-80) Without indicating light E50GG1 E50SG E50RA E50DG1 With LED indicating light (24-120 Vac/dc) E50GLG1 E50SGL E50RA E50DG1 With neon indicating light (120 Vac) E50GNG1 E50SGN E50RA E50DG1 Travel to operate contacts: Travel to reset contacts: Total travel: Force to operate contacts: Minimum return force: Operating temperature: 10 to 170 8 360 3.0 in-oz Gravity 14 to 200F (-10 to 94C) 10 to 170 8 360 3.0 in-oz Gravity 14 to 200F (-10 to 94C) 10 to 170 8 360 3.0 in-oz Gravity 14 to 200F (-10 to 94C) 10 to 170 8 360 3.0 in-oz Gravity 14 to 200F (-10 to 94C) Circuit Diagrams, see Page V8-T2-65. 2 Notes 1 Add 9 suffix to the model number for low temperature -40 to 174F (-40 to 79C) versions. 2 Low temperature rating -40 to 174F (-40 to 79C) 3 Depending upon model selected. 2 2 2 2 2 2 2 2 2 2 2 V8-T2-58 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E50 Heavy-Duty Plug-In Switches 2.6 Operating Heads 2 E50 Heavy-Duty Plug-In Switches, Operating Heads Description Side Rotary Travel to Operate Contacts Travel to Reset Contacts Total Travel Force to Operate Contacts Minimum Return Force 2 Operating Temperature 1 Without Cable With Pre-Wired Cable Catalog Number Side Rotary (requires an operating lever, see Page V8-T2-80) 2 Standard spring return 2 5 2 90 3 in-lbs 4.5 in-oz 10 to 200F 10 to 200F (-12 to 94C) 3 (-12 to 94C) 3 E50DR1 Low temperature spring return 2 5 2 90 3 in-lbs 4.5 in-oz -40 to 175F (-40 to 79C) E50DR19 2 Low force spring return 2 15 6 90 1.5 in-lbs 2.5 in-oz 10 to 200F 10 to 200F (-12 to 94C) 3 (-12 to 94C) 3 E50DL1 2 Maintained two-position 50 50 90 3 in-lbs -- 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DM1 2 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DS1 -31 to 175F (-34 to 79C) 2 Side Pushbutton Spring Return 2 Spring return 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 2 2 Adjustable Spring Return Adjustable spring return 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DS2 2 2 2 2 Side Push Roller Side Push Roller Spring return 4 Side Pushbutton 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DS3 5 2 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DS4 5 2 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DH1 2 Side Pushbutton Maintained 0.200 in 0.130 in 0.320 in 5 lbs 5 lbs 2 2 2 Top Pushbutton Spring Return Spring return 0.040 in 0.020 in 0.280 in 4 lbs 8 oz 14 to 250F (-10 to 121C) 14 to 221F (-10 to 105C) E50DT1 2 2 2 Adjustable Spring Return Adjustable spring return 0.040 in 0.020 in 0.280 in 4 lbs 8 oz 14 to 250F (-10 to 121C) 14 to 221F (-10 to 105C) E50DT2 2 2 2 2 Notes 1 Temperature ranges below 32F (0C) are based on absence of freezing moisture or water. 2 CW (clockwise) and CCW (counterclockwise) operation, easily convertible to CW only or CCW only operation. 3 For CW and CCW operation. For CW only or CCW only operation, high temperature limit increases to 250F (121C) without cable, and 221F (105C) with pre-wired cable. 4 Roller can be converted in the field between horizontal and vertical. 5 Roller shaft is 0.38 in (9.5 mm) longer on E50DS4, see Dimensions on Page V8-T2-66. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2 2 2 V8-T2-59 2.6 E50 Heavy-Duty Plug-In Switches E50 Heavy-Duty Plug-In Switches, Operating Heads, continued 2 2 2 Limit Switches Description Top Push Roller Travel to Reset Contacts 0.040 in 0.020 in Total Travel Force to Operate Contacts Minimum Return Force 0.280 in 4 lbs 8 oz Operating Temperature 1 Without Cable With Pre-wired Cable Catalog Number 14 to 250F (-10 to 121C) 14 to 221F (-10 to 105C) E50DT3 Top Push Roller Spring return 2 Travel to Operate Contacts 2 2 2 Wobble Head, Spring Return 2 Wobble Head, Spring Return (requires a wobble operator, see Page V8-T2-80) Standard duty 10 6 15 2 in-lbs 2.4 in-oz 14 to 250F (-10 to 121C) 14 to 221F (-10 to 105C) E50DW1 Heavy-duty high strength steel 10 6 15 2 in-lbs 2.4 in-oz 14 to 250F (-10 to 121C) 14 to 221F (-10 to 105C) E50DW2 2 2 2 Switch Bodies 2 E50 Heavy-Duty Plug-In Switches, Switch Bodies 2 2 2 2 2 2 2 Single-Pole 1NO-1NC Two-Pole 2NO-2NC Parallel Wired Indicator Light Two-Pole 2NC-1NO Series Wired Indicator Light Switch Body Construction 1 Catalog Number Catalog Number Catalog Number Without indicating light E50SA E50SB -- With LED indicating light 24-120 Vac/dc E50SAL E50SBL E50SCL With neon indicating light 120 Vac E50SAN E50SBN -- Circuit Diagrams, see Page V8-T2-65. 2 Note 1 Indicating lights are supplied from the factory wired as shown in Circuit Diagrams on Page V8-T2-65. However, they can be easily re-connected to terminals 1 and 2 if necessary (SPDT). 2 2 2 2 2 2 2 2 2 2 V8-T2-60 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.6 Limit Switches E50 Heavy-Duty Plug-In Switches Receptacles 2 E50 Heavy-Duty Plug-In Switches, Receptacles Description Surface Mount Poles Single-pole (5 terminal) Two-pole (9 terminal) 2 1/2 NPT -- E50RA 20 mm -- E50RA20 2 2 1/2 NPT -- E50RB 3/4 NPT -- E50RB34 20 mm -- E50RB20 2 Single-pole (5 terminal) -- -- E50RAM 2 Two-pole (9 terminal) -- -- E50RBM Single-pole (5 terminal) 5-pin mini-connector -- E50RAP5 -- E50RAP5-W -- E50RBP9 2 2 2 Mini-Connector Epoxy filled receptacle with pre-wired mini-connector. (The -W version is a wiring scheme typically used in automotive applications.) Two-pole (9 terminal) Micro-Connector Catalog Number Manifold Mount Rear wiring entrance instead of conduit hole, gasket on back for oil tightness Mini-Connector 2 Cable Length Surface Mount Conduit entrance, front or rear mounting Manifold Mount Conduit Entrance 9-pin mini-connector 2 2 2 Micro-Connector Epoxy filled receptacle with M12 DC micro-connector Single-pole (5 terminal) -- -- E50RAA5 1 2 2 2 Pre-Wired Cable 2 Pre-Wired Cable Epoxy filled receptacle with pre-wired 16 gauge, yellow jacketed, type SOOW-A cable. Cable enters through hole threaded for conduit. Single-pole (5 terminal) 1/2 NPT 20 mm Two-pole (9 terminal) 1/2 NPT 20 mm 8 ft E50RAS 12 ft E50RAS12 20 ft E50RAS20 8 ft E50RA20S 12 ft E50RA20S12 20 ft E50RA20S20 8 ft E50RBS 12 ft E50RBS12 20 ft E50RBS20 2 2 2 2 8 ft E50RB20S 12 ft E50RB20S12 20 ft E50RB20S20 Wiring Diagrams, see Page V8-T2-65. 2 2 2 Notes 2 See listing of compatible connector cables on Page V8-T2-62. 1 2 Model E50RAA5 is not UL listed or CSA certified. 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-61 2.6 2 2 E50 Heavy-Duty Plug-In Switches Compatible Connector Cables Standard Cables 1 2 2 Limit Switches Current Rating at 600V Mini-style Straight Female Voltage Style Number of Pins Gauge Length Pin Configuration/Wire Colors (Face View Female Shown) Mini-Style, Straight Female 8A -- 5-pin 16 AWG 6 ft (2m) 1-White 2-Red 3-Green 4-Orange 5-Black CSMS5D5CY1602 7A -- 9-pin 16 AWG 12 ft (4m) 1-Orange 2-Blue 3-Red/Black 4-Green/Black 5-White 6-Red 7-Green 8-White/Black 9-Black CSMS9D9CY1602 -- 5-pin, 5-wire 22 AWG 6.0 ft (2m) 1-Brown 2-White 3-Blue 4-Black 5-Green/Yellow CSDS5A5CY2202 2 2 2 2 2 2 Micro-Style Micro-Style 4A 1 2 2 5 3 4 2 2 Accessories 2 2 E50 Heavy-Duty Plug-In Switch Accessories Description E50KH7 2 Catalog Number Adapter Plate Allows E50 to replace Square D Type AW Surface Mounting Non Plug-In Standard Box Limit Switch E50KH7 2 2 2 2 Dimensions, see Page V8-T2-67. Note 1 For a full selection of connector cables, see Tab 10, section 10.1. 2 2 2 2 2 2 2 2 2 2 V8-T2-62 Catalog Number Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E50 Heavy-Duty Plug-In Switches 2.6 E50 Heavy-Duty Plug-In Switch Accessories, continued Description 2 Catalog Number 2 Adapter Plate, continued E50KH4 Allows E50 to replace National Acme, Type D-1200M, Style 2 Mounting. Denison LoxSwitch, Model L-100W, Style 2 Mounting. Square D 9007 Type T, Style B Mounting. (Adapter plate is 1/8 in thick, with 1/4 in mounting holes.) Namco(R) long mount. E50KH4 1 2 2 2 2 E50KH5 Allows E50 to replace National Acme, Type D-1200M, Style 1 Mounting. Denison LoxSwitch, Model L-100W, Style 1 Mounting. Square D 9007 Type T, Style C Mounting. (Adapter plate is 1/8 in thick, with 1/4 in mounting holes.) E50KH5 1 2 2 2 2 E50KH2 Allows E50 to replace Eaton's 10316 Type LT Non Plug-In Two-Pole Limit Switch 2 E50KH2 2 2 2 E50KH10 Allows E50 to replace Allen-Bradley 802M Sealed Limit Switch 2 E50KH10 2 2 2 Adjustable Mounting Plate E50KH3 This is a mounting plate only 5/16 in thick and includes the proper mounting bolts and nuts. The slots in the plate allow a maximum horizontal adjustment of 1 in and vertical adjustment of 1-1/4 in E50KH3 1 2 2 2 2 Conduit Sealing Nut E50KH6 1/2 in oiltight E50KH6 2 2 2 Dimensions, see Page V8-T2-67. Note 1 Limit switch not included. 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-63 2.6 Limit Switches E50 Heavy-Duty Plug-In Switches 2 Technical Data and Specifications 2 E50 Heavy-Duty Plug-In Switches Description Specification 2 Environmental ratings NEMA 1, 3, 3S, 4, 4X, 6, 6P, 13, IP67 2 Material of construction Zinc die cast Switch gasket material Viton Universal U.S./DIN mounting dimensions 1.16 in (30 mm) x 2.34 in (60 mm) Conduit entrance 1/2 in NPT or 20 mm threading 2 Contact ratings See below Contact operation Snap action over center mechanism 2 Contact material Fine silver Maximum frequency of operation 8000 operations per hour 2 Mechanical life Side rotary 2 2 2 2 13,000,000 operations minimum Side or top push 10,000,000 operations minimum Electrical life Single-pole 1,000,000 operations typical at full load Two-pole 100,000 operations typical at full load Ambient temperature range--standard Standard without cable 14 to 250F (-10 to 121C) 2 Standard with cable 2 Low temperature without cable -40 to 250F (-40 to 121C) Low temperature with cable -40 to 221F (-40 to 105C) 2 2 2 2 14 to 221F (-10 to 105C) Repeat accuracy--standard Side operated Within 0.0012 in Top operated Within 0.0003 in Side rotary Within 0.0014 in Torque requirements: Switch body screws 25-30 lb-in Operating head screws 14-18 lb-in Wire size Will accept AWG #22-#12, single or stranded wire 2 2 2 Electrical Data--Maximum Contact Ratings (Same polarity each pole) Current, Amperes AC Volts Make Break Cont. 1 Voltamperes Current, Amperes Make Max. Make or Break Cont. 1 Break DC Volts 2 All Switches Except Gravity Return and Indicating Light Versions 2 120 60 6 10 7200 720 125 0.22 1.0 2 240 30 3 10 7200 720 250 0.11 1.0 480 15 1.5 10 7200 720 250 0.11 1.0 2 600 12 1.2 10 7200 720 250 0.11 1.0 7200 720 125 0.22 1.0 NEMA A600 Rating NEMA R300 Switches with Indicating Lights (LED or Neon) 2 NEMA A150 Rating 2 Gravity Return Switches--Maximum Contact Ratings 120 60 NEMA R150 6 10 2 NEMA 6600 Rating--Contacts on same polarity 120 30 3 5 3600 360 -- -- -- 2 240 15 1.5 5 3600 360 -- -- -- 480 7.5 0.75 5 3600 360 -- -- -- 2 600 6 0.60 5 3600 360 -- -- -- 2 Note 1 Thermal rating. Valid only if switch does not have to make or break. V8-T2-64 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E50 Heavy-Duty Plug-In Switches 2.6 Circuit Diagrams 2 Standard Assembled Switches and Switch Bodies Single-Pole 1NO-1NC Two-Pole 2NO-2NC 2 Two-Pole 1NO-2NC 2 2 2 Must be same polarity. Parallel wired indicator light. Same polarity each pole. 2 Series wired indicator light. Same polarity each pole. 2 Special Purpose Assembled Switches Neutral Position Two-Step (CW, CCW, or Both) 2 Gravity Return 2 2 Same polarity, each pole. Same polarity, each pole. 2 Must be same polarity. 2 Wiring Diagrams 2 Receptacles 1 E50RAP5 E50RAP5-W E50RBP9 2 2 2 2 2 2 E50RAA5 Blue 1 3 White E50RAS_ 2 E50RBS_ 2 2 Black 4 Brown 2 2 Green/Yellow GND 2 Note 1 The wire colors referenced on these diagrams are those internal to the switch itself. 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-65 2.6 2 2 2 Limit Switches E50 Heavy-Duty Plug-In Switches Dimensions Approximate Dimensions in Inches (mm) E50SB34 Standard 0.70 (18) Shaft Dia. 0.28 (7) 2 0.75 (19) 1 0.24 (6) 2 2 1 2 4.22 (107) Dia. 0.20 (5) Front Mtg. Hole [10-32] Tap 0.38 (10) Deep Rear Mt. Holes (2) Dia. 0.63 (16) Hole for Manifold Mtg. 0.20 (5) 3.13 (79) 1.06 (27) 0.50 (13) Pipe Tap 1.54 (39) 2 2 0.75 (19) Dia. 0.27 (7) (Over Knurl) 0.38 (10) 0.63 (16) 2 2 2.46 (63) 0.38 (10) 1.78 (45) 0.65 (16) 4.70 (119) 0.24 (6) 0.63 (16) 1 1.54 (39) 3.61 (92) 4.22 (107) 3.13 (79) 0.20 (5) 2.68 (68) 3.40 (86) Conduit Entrance 3/4-14 NPT Pipe Threads [10-32] Tap 0.38 (10) Deep Rear Mt. Holes (2) 0.65 (16) 1.31 (33) 2.05 (52) Side Push Operators Approximate Dimensions in mm [in] Pushbutton Adjustable Pushbutton Roller 2 2 3 2 2 2 2 Maintained Pushbutton 2 2 2 2 2 2 Top Push Operators Pushbutton Adjustable Pushbutton Roller 2 2 2 2 2 2 2 Wobble Operators See Operators on Page V8-T2-80. 2 V8-T2-66 Notes 1 Can accommodate both U.S., 1.16 (29.4) x 2.34 (59.5) and DIN, 1.18 (30) x 3.26 (60), mounting dimensions. 2 For E50DS4. 3 For E50DS3. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E50 Heavy-Duty Plug-In Switches 2.6 Accessories Approximate Dimensions in mm [in] 2 Adapter Plates 2 E50KH1M E50KH7 2 E50KH4 2 2 2 2 2 E50KH5 E50KH2 2 E50KH10 39 [1.54] 29.5 [1.160] 59.5 [2.340] 76 [3.00] 2 2 4.8 [0.19] 5.2 [0.204] THICK DIA. (2 HOLES) 13.5 [0.531] 2 2 #10-32 UNC-2B HOLE 2 2 Adjustable Mounting Plate 2 E50KH3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-67 2.7 2 Limit Switches E50 Heavy-Duty Factory Sealed 6P+ Switches Contents E50 Heavy-Duty Factory Sealed 6P+ Switches Description 2 Page E50 Heavy-Duty Factory Sealed 6P+ Switches Product Selection Assembled Switches--Standard . . . . . . . . . Operating Heads . . . . . . . . . . . . . . . . . . . . . Switch Bodies . . . . . . . . . . . . . . . . . . . . . . . Compatible Connector Cables . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Circuit Diagrams . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 2 2 2 2 V8-T2-69 V8-T2-72 V8-T2-73 V8-T2-74 V8-T2-74 V8-T2-76 V8-T2-77 V8-T2-77 V8-T2-78 Drawings Online 2 2 2 E50 Heavy-Duty Factory Sealed 6P+ Switches 2 Product Description Features E50 6P+ Limit Switches by Eaton's electrical sector were specifically designed to withstand the penetrating properties of cutting fluids and coolants, such as those used in the automotive industry, as well as extreme shock, vibration and temperature fluctuations. The one-piece, epoxy filled switch body is prewired at the factory to ensure leak-proof, submersible performance. This unique construction positively stops fluid from finding its way to any and all critical connections. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Our 6P+ switches can be ordered in separate components or as complete assembled devices. They are available with prewired 16 AWG cables or miniconnectors. Standard and custom cable lengths are available. As part of the E50 line, the 6P+ switches use the same operating heads as the standard E50 plug-in models to reduce the components you need to inventory. Manufactured to take the physical and environmental abuse (including cutting fluids and chemicals) of harsh industrial environments Modular, plug-in components (head and switch body) provide application flexibility, reduced inventory and less downtime Chemical resistant Viton gaskets, seals and boots are standard, and so are captive, posi-drive screws A special tertiary seal on the switch body prevents fluid from entering even when the operating head is not attached Standards and Certifications 600V rating, ridge-topped contacts and wiping action assure continuity even to logic level circuits Factory wired cable features a 350 pound pullout capacity Keyed, four direction head positioning. Standard 5 pre-travel and 90 total travel 24-120 Vac/dc LED and 120 Vac neon indicating lights available Rotary heads are field convertible CW, CCW, or both, without special tools UL Listed CSA Certified IEC.947.5.1 TUV--E9271605E02 CE (where shown) DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com V8-T2-68 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.7 Limit Switches E50 Heavy-Duty Factory Sealed 6P+ Switches Product Selection 2 Assembled Switches--Standard 2 Connection is by 8 ft cable 1. 2 E50 Heavy-Duty Factory Sealed 6P+ Switches, Assembled--Standard Assembled Switch 2 2 2 Single-Pole Lever sold separately Operating Head Type Side Rotary 2 2 Two-Pole Indicating Light: None LED (24-120 Vac/dc) Switch Body: E50SA6P 1NO-1NC E50SAL6P 1NO-1NC Description Assembled Switch Catalog Number Neon (120 Vac) E50SAN6P 1NO-1NC None LED (24-120 Vac/dc) Neon (120 Vac) E50SB6P 2NO-2NC E50SBL6P 2NO-2NC E50SBN6P 2NO-2NC 2 2 Assembled Switch Catalog Number 2 Side Rotary (requires an operating lever, see Page V8-T2-80) Standard spring return--E50DR1 3 E50AR16P E50ALR16P E50ANR16P E50BR16P E50BLR16P E50BNR16P Low force spring return--E50DL1 3 E50AL16P E50ALL16P E50ANL16P E50BL16P E50BLL16P E50BNL16P Maintained twoposition--E50DM1 E50AM16P E50ALM16P E50ANM16P E50BM16P E50BLM16P E50BNM16P E50AS16P E50ALS16P E50ANS16P E50BS16P E50BLS16P E50BNS16P Side Pushbutton Spring Return Spring return-- E50DS1 2 2 2 2 2 2 2 Adjustable Spring Return Adjustable spring return--E50DS2 E50AS26P E50ALS26P E50ANS26P E50BS26P E50BLS26P E50BNS26P 2 2 2 2 Circuit Diagrams, see Page V8-T2-77. Notes 1 Connection options (add the code suffix from the table below to the end of the catalog number): Option Mini-connector 4 Cable connection 2 3 4 2 Catalog Number Code Suffix Single-pole (5-pin mini-connector) CSMS5D5CY1602 C Two-pole (9-pin mini-connector) CSMS9D9CY1602 C 12 ft cable length (standard) -- 12 20 ft cable length (standard) -- 20 Other lengths (special order) -- Length in ft 2 2 2 2 For operating head specifications, see Page V8-T2-72. CW (clockwise) and CCW (counterclockwise) operation, easily convertible to CW only or CCW only operation. For a full selection of connector cables, see Tab 10, section 10.1. 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-69 2.7 Limit Switches E50 Heavy-Duty Factory Sealed 6P+ Switches 2 Connection is by 8 ft cable 1. 2 Assembled Switch E50 Heavy-Duty Factory Sealed 6P+ Switches, Assembled--Standard, continued 2 2 2 2 Single-Pole Lever sold separately 2 2 2 Indicating Light: None LED (24-120 Vac/dc) Neon (120 Vac) None LED (24-120 Vac/dc) Neon (120 Vac) Switch Body: E50SA6P 1NO-1NC E50SAL6P 1NO-1NC E50SAN6P 1NO-1NC E50SB6P 2NO-2NC E50SBL6P 2NO-2NC E50SBN6P 2NO-2NC Operating Head Type 2 Description Side Push Roller Assembled Switch Catalog Number Assembled Switch Catalog Number Side Push Roller Spring return-- E50DS3 3 2 Two-Pole E50AS36P E50ALS36P E50ANS36P E50BS36P E50BLS36P E50BNS36P E50AH16P E50ALH16P E50ANH16P E50BH16P E50BLH16P E50BNH16P 2 2 Side Pushbutton Side Pushbutton Maintained-- E50DH1 2 2 2 Top Pushbutton Spring Return Spring return-- E50DT1 E50AT16P E50ALT16P E50ANT16P E50BT16P E50BLT16P E50BNT16P Adjustable Spring Return Adjustable spring return--E50DT2 E50AT26P E50ALT26P E50ANT26P E50BT26P E50BLT26P E50BNT26P 2 2 2 2 2 2 Circuit Diagrams, see Page V8-T2-77. 2 Notes 1 Connection options (add the code suffix from the table below to the end of the catalog number): 2 Option 2 Mini-connector 4 2 Cable connection 2 2 2 3 2 4 Catalog Number Code Suffix Single-pole (5-pin mini-connector) CSMS5D5CY1602 C Two-pole (9-pin mini-connector) CSMS9D9CY1602 C 12 ft cable length (standard) -- 12 20 ft cable length (standard) -- 20 Other lengths (special order) -- Length in ft For operating head specifications, see Page V8-T2-72. Roller can be converted in the field between horizontal and vertical. For a full selection of connector cables, see Tab 10, section 10.1. 2 2 V8-T2-70 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.7 Limit Switches E50 Heavy-Duty Factory Sealed 6P+ Switches Connection is by 8 ft cable 1. Assembled Switch 2 E50 Heavy-Duty Factory Sealed 6P+ Switches, Assembled--Standard, continued 2 2 2 Single-Pole Lever sold separately Indicating Light: None Switch Body: E50SA6P 1NO-1NC E50SAL6P 1NO-1NC Operating Head Type 2 Description Top Push Roller 2 Two-Pole LED (24-120 Vac/dc) Neon (120 Vac) E50SAN6P 1NO-1NC Assembled Switch Catalog Number None LED (24-120 Vac/dc) Neon (120 Vac) 2 E50SB6P 2NO-2NC E50SBL6P 2NO-2NC E50SBN6P 2NO-2NC 2 2 Assembled Switch Catalog Number Top Push Roller Spring return-- E50DT3 E50AT36P E50ALT36P E50ANT36P E50BT36P E50BLT36P E50BNT36P 2 2 2 Wobble Head, Spring Return 2 Wobble Head, Spring Return (requires a wobble operator, see Page V8-T2-80) Standard duty-- E50DW1 E50AW16P E50ALW16P E50ANW16P E50BW16P E50BLW16P E50BNW16P Heavy-duty high strength steel-- E50DW2 E50AW26P E50ALW26P E50ANW26P E50BW26P E50BLW26P E50BNW26P 2 Notes 1 Connection options (add the code suffix from the table below to the end of the catalog number): Option Cable connection 2 3 2 2 Circuit Diagrams, see Page V8-T2-77. Mini-connector 3 2 Catalog Number Code Suffix Single-pole (5-pin mini-connector) CSMS5D5CY1602 C Double-pole (9-pin mini-connector) CSMS9D9CY1602 C 12 ft cable length (standard) -- 12 20 ft cable length (standard) -- 20 Other lengths (special order) -- Length in ft 2 2 2 2 2 For operating head specifications, see Page V8-T2-72. For a full selection of connector cables, see Tab 10, section 10.1. 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-71 2.7 2 E50 Heavy-Duty Factory Sealed 6P+ Switches, Operating Heads 2 Description Side Rotary 2 2 2 2 2 E50 Heavy-Duty Factory Sealed 6P+ Switches Operating Heads 2 2 Limit Switches Travel to Operate Contacts Travel to Reset Contacts Total Travel Force to Operate Contacts Minimum Return Force Operating Temperature 1 Without Cable With Pre-wired Cable Catalog Number Side Rotary (requires an operating lever, see Page V8-T2-80) Standard spring return 2 5 2 90 3 in-lbs 4.5 in-oz 10 to 200F 10 to 200F (-12 to 94C) 3 (-12 to 94C) 3 E50DR1 Low temperature spring return 2 5 2 90 3 in-lbs 4.5 in-oz -40 to 175F (-40 to 79C) E50DR19 Low force spring return 2 15 6 90 1.5 in-lbs 2.5 in-oz 10 to 200F 10 to 200F (-12 to 94C) 3 (-12 to 94C) 3 E50DL1 Maintained two-position 50 50 90 3 in-lbs -- 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DM1 -31 to 175F (-34 to 79C) Side Pushbutton Spring Return Spring return 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DS1 Adjustable Spring Return Adjustable spring return 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DS2 Side Push Roller Side Push Roller 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DS3 5 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DS4 5 0.200 in 0.130 in 0.320 in 5 lbs 5 lbs 14 to 200F (-10 to 94C) 14 to 200F (-10 to 94C) E50DH1 2 2 2 2 2 2 Spring return 4 2 2 Side Pushbutton 2 Side Pushbutton Maintained 2 2 2 Top Pushbutton Spring Return Spring return 0.040 in 0.020 in 0.280 in 4 lbs 8 oz 14 to 250F (-10 to 121C) 14 to 221F (-10 to 105C) E50DT1 Adjustable Spring Return Adjustable spring return 0.040 in 0.020 in 0.280 in 4 lbs 8 oz 14 to 250F (-10 to 121C) 14 to 221F (-10 to 105C) E50DT2 2 2 2 2 2 2 Notes 1 Temperature ranges below 32F (0C) are based on absence of freezing moisture or water. 2 CW (clockwise) and CCW (counterclockwise) operation, easily convertible to CW only or CCW only operation. 3 For CW and CCW operation. For CW only or CCW only operation, high temperature limit increases to 250F (121C) without cable, and 221F (105C) with pre-wired cable. 4 Roller can be converted in the field between horizontal and vertical. 5 Roller shaft is 0.38 in (9.5 mm) longer on E50DS4, see Dimensions on Page V8-T2-78. 2 2 2 V8-T2-72 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E50 Heavy-Duty Factory Sealed 6P+ Switches 2.7 E50 Heavy-Duty Factory Sealed 6P+ Switches, Operating Heads, continued Description Top Push Roller Travel to Operate Contacts Travel to Reset Contacts 0.040 in 0.020 in Total Travel Force to Operate Contacts Minimum Return Force 0.280 in 4 lbs 8 oz 2 Operating Temperature 1 Without Cable With Pre-Wired Cable Catalog Number 14 to 250F (-10 to 121C) 14 to 221F (-10 to 105C) E50DT3 Top Push Roller Spring return 2 2 2 2 Wobble Head, Spring Return 2 Wobble Head, Spring Return (requires a wobble operator, see Page V8-T2-80) Standard duty 10 6 15 2 in-lbs 2.4 in-oz 14 to 250F (-10 to 121C) 14 to 221F (-10 to 105C) E50DW1 Heavy-duty high strength steel 10 6 15 2 in-lbs 2.4 in-oz 14 to 250F (-10 to 121C) 14 to 221F (-10 to 105C) E50DW2 2 Switch Bodies 2 E50 Heavy-Duty Factory Sealed 6P+, Switch Bodies Circuit 2 Switch Body Construction Cable Length Catalog Number 2 Without indicating light 8 ft E50SA6P 12 ft E50SA6P12 2 20 ft E50SA6P20 8 ft E50SAL6P 12 ft E50SAL6P12 20 ft E50SAL6P20 8 ft E50SAN6P 12 ft E50SAN6P12 20 ft E50SAN6P20 Pre-Wired Cable Single-pole 1NO-1NC With LED indicating light 24 -120 Vac/dc With neon indicating light 120 Vac Two-pole 2NO-2NC Without indicating light With LED indicating light 24-120 Vac/dc With neon indicating light 120 Vac Mini-Connector 2 2 Circuit Diagrams, see Page V8-T2-77. Pre-Wired Cable 2 8 ft E50SB6P 12 ft E50SB6P12 20 ft E50SB6P20 8 ft E50SBL6P 12 ft E50SBL6P12 8 ft E50SBN6P 12 ft E50SBN6P12 20 ft E50SBN6P20 Without indicating light normal wiring -- E50SA6PC Without indicating light alternate wiring -- E50SA6PC-W With LED indicating light 24-120 Vac/dc -- E50SAL6PC With neon indicating light 120 Vac -- E50SAN6PC Without indicating light -- E50SB6PC With LED indicating light 24-120 Vac/dc -- E50SBL6PC With neon indicating light 120 Vac -- E50SBN6PC 2 2 2 2 2 2 2 2 2 Mini-Connector Single-pole 1NO-1NC Two-pole 2NO-2NC 2 2 2 2 2 Notes 2 See listing of compatible connector cables on Page V8-T2-74. 1 Temperature ranges below 32F (0C) are based on absence of freezing moisture or water. 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-73 2.7 2 2 E50 Heavy-Duty Factory Sealed 6P+ Switches Compatible Connector Cables Standard Cables 1 2 2 Limit Switches Current Rating at 600V Mini-Style, Straight Female Voltage Style Number of Pins Gauge Length Pin Configuration/Wire Colors (Face View Female Shown) Mini-Style, Straight Female 8A -- 5-pin 16 AWG 6 ft (2m) 1-White 2-Red 3-Green 4-Orange 5-Black CSMS5D5CY1602 7A -- 9-pin 16 AWG 12 ft (4m) 1-Orange 2-Blue 3-Red/Black 4-Green/Black 5-White 6-Red 7-Green 8-White/Black 9-Black CSMS9D9CY1602 2 2 2 2 2 2 2 Accessories E50 Heavy-Duty Factory Sealed 6P+ Switch Accessories 2 2 Catalog Number E50KH1M Adapter Plate Allows E50 to replace Eaton's 10316 Type LP Manifold Mounting Plug-In Limit Switch E50KH1M Allows E50 to replace Square D Type AW Surface Mounting Non Plug-In Standard Box Limit Switch E50KH7 2 2 2 E50KH7 2 2 2 2 Dimensions, see Page V8-T2-78. 2 Note 1 For a full selection of connector cables, see Tab 10, section 10.1. 2 2 2 2 2 2 2 2 2 V8-T2-74 Catalog Number Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E50 Heavy-Duty Factory Sealed 6P+ Switches 2.7 E50 Heavy-Duty Factory Sealed 6P+ Switch Accessories, continued 2 Catalog Number 2 Adapter Plate, continued E50KH4 Allows E50 to replace National Acme, Type D-1200M, Style 2 Mounting. Denison LoxSwitch, Model L-100W, Style 2 Mounting. Square D 9007 Type T, Style B Mounting. (Adapter plate is 1/8 in thick, with 1/4 in mounting holes.) Namco(R) long mount. E50KH4 1 2 2 2 2 E50KH5 Allows E50 to replace National Acme, Type D-1200M, Style 1 Mounting. Denison LoxSwitch, Model L-100W, Style 1 Mounting. Square D 9007 Type T, Style C Mounting. (Adapter plate is 1/8 in thick, with 1/4 in mounting holes.) E50KH5 1 2 2 2 2 E50KH2 Allows E50 to replace Eaton's 10316 Type LT Non Plug-In Two-Pole Limit Switch 2 E50KH2 2 2 2 E50KH10 Allows E50 to replace Allen-Bradley 802M Sealed Limit Switch 2 E50KH10 2 2 2 Adjustable Mounting Plate E50KH3 This is a mounting plate only 5/16 in thick and includes the proper mounting bolts and nuts. The slots in the plate allow a maximum horizontal adjustment of 1 in and vertical adjustment of 1-1/4 in E50KH3 1 2 2 2 Conduit Sealing Nut E50KH6 1/2 in oiltight 2 E50KH6 2 Dimensions, see Page V8-T2-78. 2 Note 1 Limit switch not included. 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-75 2.7 Limit Switches E50 Heavy-Duty Factory Sealed 6P+ Switches 2 Technical Data and Specifications 2 E50 Heavy-Duty Factory Sealed 6P+ Switches Description Specification 2 Environmental ratings NEMA 1, 3, 3S, 4, 4X, 6, 6P, 13, IP67, IP69K 2 Material of construction Zinc die cast Switch gasket material Viton Universal U.S./DIN mounting dimensions 1.16 in (30 mm) x 2.34 in (60 mm) Conduit entrance 1/2 in NPT or 20 mm threading 2 Contact ratings See below Contact operation Snap action over center mechanism 2 Contact material Fine silver Maximum frequency of operation 8000 operations per hour 2 Mechanical life Side rotary 2 2 2 2 13,000,000 operations minimum Side or top push 10,000,000 operations minimum Electrical life Single-pole 1,000,000 operations typical at full load Double-pole 100,000 operations typical at full load Ambient temperature range--standard Standard without cable 14 to 250F (-10 to 121C) 2 Standard with cable 2 Low temperature without cable -40 to 250F (-40 to 121C) Low temperature with cable -40 to 221F (-40 to 105C) 2 2 2 14 to 221F (-10 to 105C) Repeat accuracy--standard Side operated Within 0.0012 in Top operated Within 0.0003 in Side rotary Within 0.0014 in Torque requirements Operating head screws 14-18 lb-in 2 2 2 Electrical Data--Maximum Contact Ratings (Same polarity each pole) Current, Amperes AC Volts Make Break Cont. 1 Voltamperes Current, Amperes Make Max. Make or Break Cont. 1 Break DC Volts 2 All Switches Except Gravity Return and Indicating Light Versions 2 120 60 6 10 7200 720 125 0.22 1.0 2 240 30 3 10 7200 720 250 0.11 1.0 480 15 1.5 10 7200 720 250 0.11 1.0 2 600 12 1.2 10 7200 720 250 0.11 1.0 7200 720 125 0.22 1.0 2 2 2 NEMA A600 Rating NEMA R300 Switches with Indicating Lights (LED or Neon) NEMA A150 Rating 120 60 NEMA R150 6 10 Note 1 Thermal rating. Valid only if switch does not have to make or break. 2 2 2 2 V8-T2-76 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E50 Heavy-Duty Factory Sealed 6P+ Switches 2.7 Circuit Diagrams 1 2 Standard Assembled Switches Single-Pole 1NO-1NC 2 Two-Pole 2NO-2NC 2 2 2 2 Must be same polarity. 2 Same polarity, each pole. Switch Bodies Pre-Wired Cable-- Single-Pole 1NO-1NC E50SA6P_ 2 Pre-Wired Cable-- Two-Pole 2NO-2NC E50SAL6P_ E50SB6P_ 2 E50SBL6P_ 2 2 2 2 2 Wiring Diagrams 1 2 Mini-Connector--Single-Pole 1NO-1NC E50SA6PC E50SA6PC-W 2 E50SAL6PC/E50SAN6PC 2 2 2 2 2 Mini-Connector--Two-Pole 2NO-2NC E50SB6PC 2 E50SBL6PC/E50SBN6PC 2 2 2 2 2 2 2 Note 1 The wire colors referenced on these diagrams are those internal to the switch itself. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2 V8-T2-77 2.7 2 Limit Switches E50 Heavy-Duty Factory Sealed 6P+ Switches Dimensions Approximate Dimensions in Inches (mm) 2 Standard 2 6P+ Limit Switch with Rotary Operating Head 2.25 (57.0) 1.44 (37.0) 2 2 2 0.81 (21.0) 0.75 (19.0) Dia. 0.20 (5.0) Front Mtg. Hole 3.13 (79.0) 2 4.22 (107.0) 1 2 2 0.75 (19.0) 0.37 (9.4) 0.31 (8.0) 2.74 (69.5) 0.45 (11.4) 0.24 (6.2) 1.58 (40.1) 1.13 (28.7) Conduit Entrance 0.50 Pipe Tap 0.20 (5.2) 0.99 (25.0) 2 2 Side Push Operators Approximate Dimensions in mm [in] 2 Pushbutton 1 1.54 (39.0) [10-32] Tap 0.38 (10.0) Deep Rear Mtg. Holes (2) Adjustable Pushbutton Roller 2 2 3 2 2 2 2 Maintained Pushbutton 2 2 2 2 2 Top Push Operators Pushbutton Adjustable Pushbutton Roller 2 2 2 2 2 2 2 Wobble Operators See Operators on Page V8-T2-80. 2 V8-T2-78 Notes 1 Can accommodate both U.S., 1.16 (29.4) x 2.34 (59.5) and DIN, 1.18 (30.0) x 3.26 (60.0), mounting dimensions. 2 For E50DS4. 3 For E50DS3. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches E50 Heavy-Duty Factory Sealed 6P+ Switches 2.7 Accessories Approximate Dimensions in mm [in] 2 Adapter Plates 2 E50KH1M E50KH7 2 E50KH4 2 2 2 2 2 E50KH5 E50KH2 2 E50KH10 39 [1.54] 29.5 [1.160] 59.5 [2.340] 76 [3.00] 2 2 4.8 [0.19] 5.2 [0.204] THICK DIA. (2 HOLES) 13.5 [0.531] 2 2 #10-32 UNC-2B HOLE 2 2 Adjustable Mounting Plate 2 E50KH3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-79 2.8 2 Limit Switches Operators Contents Operators Description 2 Operators Product Selection Roller Type Operators . . . . . . . . . . . . . . . . . Rod Type Operators . . . . . . . . . . . . . . . . . . Wobble Type Operators . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 2 Page V8-T2-81 V8-T2-83 V8-T2-84 V8-T2-84 Drawings Online 2 2 2 2 2 2 Operators 2 Product Description Features The Operators presented here are used with Eaton's E50 Plug-In and 6P+ limit switches, as well as our 10316 rotary type limit switches. A wide variety of styles and sizes are available to provide optimum performance for nearly any application. 2 2 2 2 2 2 2 2 2 Wide variety of operator types for rotary and wobble style limit switches Rollers and rods available in metal and nonmetal contact surfaces DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2 2 2 2 2 2 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com V8-T2-80 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.8 Limit Switches Operators Product Selection 2 Roller Type Operators For rotary head switches: E50 Plug-In, E50 6P+, and 10316. 2 Note: Only operators with Nylatron rods or rollers should be used with explosion-proof limit switches. 2 2 Operators--Roller Type Roller Type E50KL200 E50KL355 E50KL377 E50KL554 E50KL580 Minimum Required Return Torque 1 Approximate Dimensions in Inches (mm) A Lever Length 2 B Roller Diameter C Roller Width D E F Catalog Number 0.24 (6.1) E50KL39 Standard Roller (Stainless Steel) Metal 0.62 in-oz 0.88 (22.2) 0.75 (19.0) 0.32 (8.1) 0.31 (7.9) 0.20 (5.1) Metal 0.95 in-oz 1.38 (34.9) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL40 Ball bearing 0.77 in-oz 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) E50KL531 Nylatron 0.53 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL200 Metal 1.10 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL355 Nylatron 0.96 in-oz 1.50 (38.1) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) E50KL377 Without roller 0.32 in-oz 1.50 (38.1) -- -- 0.34 (8.6) -- -- E50KL32 Ball bearing 1.10 in-oz 2.00 (50.8) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) E50KL552 Nylatron 0.71 in-oz 2.00 (50.8) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL546 Metal 1.50 in-oz 2.00 (50.8) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL549 Nylatron 1.45 in-oz 2.00 (50.8) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) E50KL572 Ball bearing 1.50 in-oz 2.50 (63.5) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) E50KL553 Nylatron 1.00 in-oz 2.50 (63.5) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL547 Metal 2.00 in-oz 2.50 (63.5) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL550 Nylatron 1.80 in-oz 2.50 (63.5) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) E50KL573 Nylatron 1.40 in-oz 2.50 (63.5) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.11 (2.8) 0.17 (4.3) E50KL575 Ball bearing 1.80 in-oz 3.00 (76.2) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) E50KL554 Nylatron 1.30 in-oz 3.00 (76.2) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL548 Metal 2.50 in-oz 3.00 (76.2) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL551 Nylatron 2.30 in-oz 3.00 (76.2) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) E50KL574 Nylatron 1.80 in-oz 3.00 (76.2) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.11 (2.8) 0.17 (4.3) E50KL576 Dimensions, see Page V8-T2-84. Ball bearing 0.77 in-oz 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.18 (4.6) 0.24 (6.1) E50KL580 Nylatron 0.53 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.27 (6.9) 0.31 (7.9) E50KL310 Metal 1.10 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.27 (6.9) 0.31 (7.9) E50KL579 Nylatron 0.96 in-oz 1.50 (38.1) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.23 (5.8) 0.31 (7.9) E50KL536 Offset Inboard Roller (Stainless Steel) E50KL27 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Roller On Reverse Side (Stainless Steel) E50KL24 2 Nylatron 0.65 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.03 (0.8) -- -- E50KL24 Metal 1.20 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.03 (0.8) -- -- E50KL25 Ball bearing 0.90 in-oz 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.04 (1.0) -- -- E50KL26 2 2 2 2 2 2 Offset Outboard Roller (Stainless Steel) Nylatron 0.65 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.03 (0.8) -- -- E50KL27 Metal 1.20 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.03 (0.8) -- -- E50KL28 Ball bearing 0.90 in-oz 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.04 (1.0) -- -- E50KL29 Nylatron 1.10 in-oz 1.50 (38.1) 0.75 (19.0) 1.00 (25.4) -- -- -- E50KL30 Dimensions, see Page V8-T2-85. 2 2 2 Notes 1 Caution: When selecting lever, the minimum required return torque of lever should not exceed minimum return force available in operating head as given in operating head specifications. 2 Length from the operating shaft axis to the roller axis (or to the tip for non-roller operators). Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2 2 V8-T2-81 2.8 2 Limit Switches Operators Note: Only operators with Nylatron rods or rollers should be used with explosion-proof limit switches. Operators--Roller Type, continued 2 Minimum Required Return Torque 1 Approximate Dimensions in Inches (mm) A B Lever Length 2 Roller Diameter C Roller Width D E F Catalog Number 0.45 in-oz 0.69 (17.5) 0.85 (22.0) 0.18 (4.6) -- -- -- E50KL532 0.69 (17.5) Roller length: 1.50 (38.1) 3 0.75 (19.0) 0.32 (8.1) 0.48 (12.2) 0.24 (6.1) 0.28 (7.1) E50KL340 0.75 (19.0) 0.32 (8.1) 0.48 (12.2) 0.24 (6.1) 0.28 (7.1) E50KL465 0.69 (17.5) 0.25 (6.4) 0.48 (12.2) 0.16 (4.1) 0.22 (5.6) E50KL535 0.69 (17.5) 0.25 (6.4) 0.23 (5.8) 0.30 (7.6) -- E50KL539 0.75 (19.0) 0.32 (8.1) 0.29 (7.4) 0.33 (8.4) -- E50KL201 0.75 (19.0) 0.32 (8.1) 0.29 (7.4) 0.33 (8.4) -- E50KL201SPL 6 3.40 in-oz 4 0.75 (19.0) 0.32 (8.1) 0.29 (7.4) 0.33 (8.4) -- E50KL538 Nylatron 1.90 in-oz 4 0.75 (19.0) 0.50 (12.7) 0.46 (11.6) 0.48 (12.2) -- E50KL599 Nylatron 3.10 in-oz 4 0.75 (19.0) 1.00 (25.4) 0.90 (22.9) 0.95 (24.1) -- E50KL537 2 Large Nylatron 4.50 in-oz 4 0.5 (12.7) to 3.25 (82.6) 4.00 (102.0) 0.11 (2.8) 0.11 (2.8) 0.19 (4.8) -- E50KL598 2 Without roller 1.20 in-oz 4 0.5 (12.7) to 3.75 (95.2) -- -- -- -- -- E50KL31 Nylatron 2.50 in-oz 4 1.63 (41.3) to 3.75 (95.2) 5 1.50 (38.1) 0.29 (7.4) 0.26 (6.6) 0.32 (8.1) -- E50KL443 G Catalog Number 2 2 Roller Type E50KL532 Bantam Lever Metal 2 2 E50KL340 2 2 2 E50KL201 Precision Adjustment Nylatron 0.65 in-oz Metal 1.20 in-oz Ball bearing 0.90 in-oz Dimensions, see Page V8-T2-85. 2 Adjustable Roller (Stainless Steel) Ball bearing 2.50 in-oz 4 2 Nylatron 1.90 in-oz 4 2 E50KL537 Metal 2 2 Dimensions, see Page V8-T2-86. 2 Operators--Roller Type, continued 2 2 2 1.0 (25.4) to 3.75 (95.2) 5 Roller Type E50KL545 Minimum Required Return Torque 1 Approximate Dimensions in Inches (mm) A B Lever Length 2 Roller Diameter C Roller Width D E F Fork Lever--Both Rollers on One Side 2 Ball bearing -- 0.69 (17.5) 0.25 (6.4) 0.08 (2.0) 0.14 (3.6) -- -- E50KL545 Nylatron -- 0.75 (19.0) 0.32 (8.1) 0.16 (4.1) 0,20 (5.1) -- -- E50KL204 2 Metal -- 0.75 (19.0) 0.32 (8.1) 0.16 (4.1) 0,20 (5.1) -- -- E50KL544 Nylatron -- 0.75 (19.0) 1.00 (25.4) 0.84 (21.3) 0.88 (22.4) -- -- E50KL543 0.25 (6.4) 0.08 (2.0) 0.14 (3.6) 0.64 (16.3) 0.70 (17.8) E50KL542 2 E50KL542 Fork Lever--One Roller Outside, One Inside Ball bearing 2 2 2 1.50 (38.1) -- 1.50 (38.1) 0.69 (17.5) Nylatron -- 0.75 (19.0) 0.32 (8.1) 0.16 (4.1) 0.20 (5.1) 0.73 (18,5) 0.77 (19.6) E50KL203 Metal -- 0.75 (19.0) 0.32 (8.1) 0.16 (4.1) 0.20 (5.1) 0.73 (18,5) 0.77 (19.6) E50KL541 Dimensions, see Page V8-T2-86. Notes 1 Caution: When selecting lever, the minimum required return torque of lever should not exceed minimum return force available in operating head as given in operating head specifications. 2 Length from the operating shaft axis to the roller axis (or to the tip for non-roller operators). 3 Maximum length dimension between operating shaft axis to roller axis for comparison. Precision adjustable to lesser dimensions. 4 Applies when lever is extended to the maximum dimension. 5 By reassembling lever, minimum length can be reduced another 0.5 in (12.7 mm). 6 High-grade stainless steel. 2 2 2 2 V8-T2-82 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches Operators 2.8 Rod Type Operators For rotary head switches: E50 Plug-In, E50 6P+, and 10316. 2 Note: Only operators with Nylatron rods or rollers should be used with explosion-proof limit switches. 2 2 Operators--Rod Type Rod Type Nylon/Metal Metal/Steel Minimum Required Return Torque 1 Approximate Dimensions in Inches (mm) A B Rod Length Rod Diameter (Maximum) 2 Catalog Number 5.50 (140.0) 0.19 (4.8) E50KL399 0.12 (3.2) E50KL202 2 2 Adjustable Rod 3 2 Nylon 0.40 in-oz Metal 0.92 in-oz 3 Metal 2.20 in-oz 3 8.75 (222.0) Rod size (square): 0.12 (3.2) x 0.12 (3.2) E50KL581 2 Stainless steel 7.00 in-oz 3 9.00 (229.0) 0.19 (4.8) E50KL220 Bendable steel 5.00 in-oz 3 12.00 (305.0) 0.12 (3.2) E50KL226 2 2 Clamps for Adjustable Rods (Rod not included) Clamp for ... 0.19 (4.8) diameter rods E50KL35 0.12 (3.2) diameter rods E50KL36 0.25 (6.4) diameter rods E50KL41 2 2 2 Dimensions, see Page V8-T2-87. 2 Operators--Rod Type, continued Minimum Required Return Torque 1 Approximate Dimensions in Inches (mm) A B Rod Length 2 Rod Diameter C D Catalog Number Nylon 3.50 in-oz -- -- -- -- E50KL556 Stainless steel 2.80 in-oz -- -- -- -- E50KL421 Rod Type Nylon/Steel Nylon Covered Wire 2 2 Spring Rod 2 2 Adjustable Wire Nylon covered wire 1.50 in-oz 3 -- -- -- -- 2 E50KL533 2 Nylatron Adjustable Wide Roller Lever Nylatron 4.50 in-oz 3 -- -- -- -- 2 E50KL37 2 Nylatron 2 Nylatron Loop Nylatron 0.40 in-oz 6.00 (152.0) 0.158 (4.0) -- -- 2 E50KL142 2 Zinc-Plated Steel Eye Bolt Zinc-plated steel 0.53 in-oz 150.00 (38.1) 0.1875 (4.8) Loop ID: 0.375 (9.5) 0.52 (13.1) 0.24 (8.6) 2 E50KL33 2 2 2 Dimensions, see Page V8-T2-87. Notes 1 Caution: When selecting lever, the minimum required return torque of lever should not exceed minimum return force available in operating head as given in operating head specifications. 2 Length from the operating shaft axis to tip. 3 Applies when lever is extended to the maximum dimension. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2 2 V8-T2-83 2.8 Limit Switches Operators 2 Wobble Type Operators For E50DW1 and E50DWZ Operator Heads on E50 Plug-In and E50 6P+ Switches. 2 Note: Only operators with Nylatron rods or rollers should be used with explosion-proof limit switches. 2 2 Operators--Wobble Type Wobble Type E50KW2 Catalog Number Nylon Rod E50KW2 2 2 2 2 2 E50KW3 Stainless Steel Rod E50KW3 E50KW4 Coil Spring E50KW4 2 Dimensions, see Page V8-T2-88. 2 2 Dimensions 2 Roller Type Operators 2 2 Standard Roller Approximate Dimensions in Inches (mm) B C Catalog Number A Lever Length 1 B Roller Diameter C Roller Width D E F E50KL39 0.88 (22.2) 0.75 (19.0) 0.32 (8.1) 0.31 (7.9) 0.20 (5.1) 0.24 (6.1) E50KL40 1.38 (34.9) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL531 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) E50KL200 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL355 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL377 1.50 (38.1) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) 2 E50KL32 1.50 (38.1) -- -- 0.34 (8.6) -- -- E50KL552 2.00 (50.8) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) 2 E50KL546 2.00 (50.8) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL549 2.00 (50.8) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) 2 E50KL572 2.00 (50.8) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) 2 E50KL553 2.50 (63.5) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) E50KL547 2.50 (63.5) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) 2 E50KL550 2.50 (63.5) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL573 2.50 (63.5) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) 2 E50KL575 2.50 (63.5) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.11 (2.8) 0.17 (4.3) 2 E50KL554 3.00 (76.2) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) E50KL548 3.00 (76.2) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) 2 E50KL551 3.00 (76.2) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL574 3.00 (76.2) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) 2 E50KL576 3.00 (76.2) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.11 (2.8) 0.17 (4.3) F E 2 A 2 2 D 0.44 (11) 2 0.67 (17) Note 1 Length from the operating shaft axis to the roller axis (or to the tip for non-roller operators). 2 2 V8-T2-84 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.8 Limit Switches Operators C Roller on Reverse Side Approximate Dimensions in Inches (mm) B F E A D 0.44 (11) 0.67 (17) B Dia C Inboard Roller D 38 [1.50] 2 Catalog Number A Lever Length 1 B Roller Diameter C Roller Width D E F E50KL580 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.18 (4.6) 0.24 (6.1) E50KL310 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.27 (6.9) 0.31 (7.9) E50KL579 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.27 (6.9) 0.31 (7.9) E50KL536 1.50 (38.1) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.23 (5.8) 0.31 (7.9) 2 C Roller Width D E50KL24 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 0.8 [0.03] E50KL25 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 0.8 [0.03] E50KL26 38.1 [1.50] 17.5 [0.69] 6.4 [0.25] 1.0 [0.04] 2 E50KL27 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 0.8 [0.03] 2 E50KL28 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 0.8 [0.03] E50KL29 38.1 [1.50] 17.5 [0.69] 6.4 [0.25] 1.0 [0.04] E50KL30 38.1 [1.50] 19.0 [0.75] 25.4 [1.00] -- 2 Inboard 22 [0.85] 16 [0.62] C Max 60 E 20R [0.80] 16 [0.63] A F D Precision Adjustment 12.7 Screw [0.50] 2 B Roller Diameter 2 2 2 2 Bantam Lever Approximate Dimensions in mm [in] B Dia. 2 A Lever Length 1 Outboard Max 60 2 2 Offset Roller Approximate Dimensions in mm [in] Catalog Number 24 26 [0.94] 20 [1.02] [0.80] 8.4 7.6 [0.33] 16 [0.64] [0.30] 2 4.1 [0.16] 2 2 4.6 [0.18] 2 18 [0.69] 12 [0.48] 12.7 [0.50] 2 2 2 Precision Adjustment Approximate Dimensions in mm [in] Catalog Number E50KL340 E50KL465 E50KL535 2 A Lever Length 1 B Roller Diameter C Roller Width D E F 17.5 [0.69] Roller length: 38.1 [1.50] 2 19.0 [0.75] 8.1 [0.32] 12.2 [0.48] 6.1 [0.24] 7.1 [0.28] 19.0 [0.75] 8.1 [0.32] 12.2 [0.48] 6.1 [0.24] 7.1 [0.28] 17.5 [0.69] 6.4 [0.25] 12.2 [0.48] 4.1 [0.16] 5.6 [0.22] 2 2 2 2 Notes 1 Length from the operating shaft axis to the roller axis (or to the tip for non-roller operators). 2 Maximum length dimension between operating shaft axis to the roller axis for comparison. Precision adjustable to lesser dimensions. 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-85 2.8 2 Limit Switches Operators B Dia. 2 2 E D 12.7 [0.50] 108 [4.24] 95R [3.75] A Lever Length 1 B Roller Diameter C Roller Width D E 25.4 [1.0] to 95.2 [3.75] 2 17.5 [0.69] 6.4 [0.25] 5.8 [0.23] 7.6 [0.30] 19.0 [0.75] 8.1 [0.32] 7.4 [0.29] 8.4 [0.33] E50KL201SPL 3 19.0 [0.75] 8.1 [0.32] 7.4 [0.29] 8.4 [0.33] E50KL538 19.0 [0.75] 8.1 [0.32] 7.4 [0.29] 8.4 [0.33] E50KL599 19.0 [0.75] 12.7 [0.50] 11.6 [0.46] 12.2 [0.48] Catalog Number E50KL539 25.4R [1.0] 2 2 Adjustable Roller Approximate Dimensions in mm [in] C 27 [1.08] 11 [0.42] 79 [3.12] 2 E50KL201 E50KL537 19.0 [0.75] 25.4 [1.00] 22.9 [0.90] 24.1 [0.95] E50KL598 102.0 [4.00] 2.8 [0.11] 4.8 [0.19] 24.1 [0.95] 2 12.7 [0.50] to 82.6 [3.25] E50KL31 -- -- -- -- 2 12.7 [0.50] to 95.2 [3.75] E50KL443 41.3 [1.63] to 95.2 [3.75] 2 38.1 [1.50] 7.4 [0.29] 6.6 [0.26] 8.1 [0.32] 2 2 54 [2.12] 38 [1.50] 2 2 2 B Dia. 16 [0.62] 12 [0.48] Fork Lever--Both Rollers on One Side Approximate Dimensions in mm [in] C 27 [1.06] 10 [0.38] 1.0 [0.04] E D 2 Catalog Number A Lever Length 1 B Roller Diameter C Roller Width D E E50KL545 38.1 [1.50] 17.5 [0.69] 6.4 [0.25] 2.0 [0.08] 3.6 [0.14] E50KL204 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 4.1 [0.16] 5.1 [0.20] E50KL544 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 4.1 [0.16] 5.1 [0.20] E50KL543 38.1 [1.50] 19.0 [0.75] 25.4 [1.00] 21.3 [0.84] 22.4 [0.88] 2 54 [2.12] 38 [1.50)] 2 2 2 B Dia. 16 [0.62] 2 2 2 12 [0.48] Fork Lever--One Roller Outside, One Inside Approximate Dimensions in mm [in] C 27 [1.06] E D 10 F [0.38] G Catalog Number A Lever Length 1 B Roller Diameter C Roller Width D E F G E50KL542 38.1 [1.50] 17.5 [0.69] 6.4 [0.25] 2.0 [0.08] 3.6 [0.14] 16.3 [0.64] 17.8 [0.70] E50KL203 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 4.1 [0.16] 5.1 [0.20] 18.5 [0.73] 19.6 [0.77] E50KL541 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 4.1 [0.16] 5.1 [0.20] 18.5 [0.73] 19.6 [0.77] Notes 1 Length from the operating shaft axis to the roller axis (or to the tip for non-roller operators). 2 By reassembling lever, minimum length can be reduced another 12.7 mm [0.5 in]. 3 High-grade stainless steel. 2 2 2 2 2 2 2 2 2 V8-T2-86 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.8 Limit Switches Operators Approximate Dimensions in Inches or mm [in] 2 Rod Type Operators 2 Adjustable Rod A Max. Ext. A Rod Length 1 B Rod Diameter E50KL399 140.0 [5.50] 4.8 [0.19] E50KL202 B Dia. 16.26 [.64] 6.35 [.25] Catalog Number 2 2 2 3.2 [0.12] E50KL581 222.0 [8.75] Rod size (square): 3.2 [0.12] x 3.2 [0.12] E50KL220 229.0 [9.00] 4.8 [0.19] E50KL226 305.0 [12.00] 3.2 [0.12] 2 2 12.7 [.50] 9.65 [.38] 28.45 [1.12] 2 Spring Rod--E50KL556 6.35 Dia. [.25] Nylon 247.90 [9.76] 228.6 [9.0] Adjustable Wide Roller Lever 2 12.7 [.50] 307.85 [12.12] 16.26 [.64] 6.35 [.25] 12.7 [.50] 9.65 28.45 [.38] [1.12] Nylatron Loop--E50KL142 19.1 Dia. [.75] 2.29 Dia. [0.9] Steel Spring Rod 295.15 [11.62] 16.26 [.64] 2 6.6 [.26] 2 3.05 [.12] Dia. Nylon 1.52 [.06] Dia. Steelcore 2 2 2 16.26 [.64] 12.7 [.50] 9.65 [.38] 28.45 [1.12] 6.35 [.25] 12.7 [.50] 9.65 [.38] 28.45 [1.12] 2 2 2 Eye Bolt 4.0 Dia. [.158] Max. 48.3 [1.90] 2 Adjustable Wire 307.85 [12.12] Max. Ext. 307.85 [12.12] 6.35 [.25] Spring Rod--E50KL421 2 C 2 63.5 [2.50] 106.4 [4.19] Max. 4.2 [.164] 31.8 [1.125] Max. 16.3 [.64] 152.4 [6.00] 139.7 [5.50] 12.7 [.50] 6.4 22.9R [.25] [.90] 9.7 [.38] +.05 Dia. 7.16 - .00 +.002 .282 - .000 28.4 [1.12] 5.1 [.20] 22.9 [.90] 2 D 8.1 [.32] 12.7 [.50] 2 A B 9.7 [.38] 0.44 [11] 2 0.67 [17] 2 Catalog Number A Rod Length 2 B Rod Diameter C Rod Width D E50KL33 38.1 [1.50] 4.8 [0.1875] Loop ID: 9.5 [0.375] 13.1 [0.52] 8.6 [0.34] 2 2 Notes 1 Applies when lever is extended to the maximum dimension. 2 Length from the operating shaft axis to tip. 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-87 2.8 2 Limit Switches Operators Wobble Type Operators Nylon Rod Stainless Steel Rod 2 2 6.35 [.250] Dia. 2 20.60 [.81] 2 1.60 [.063] Dia. Coil Spring 8.74 Dia. [.344] 346.45 [13.64] 124.45 [4.90] 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V8-T2-88 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 146.30 [5.76] Limit Switches Non Plug-In Switches 2.9 Contents Non Plug-In Switches Description Page Non Plug-In Switches Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-90 V8-T2-91 V8-T2-91 2 2 2 2 2 2 2 2 2 2 2 Non Plug-In Switches Product Description Features 10316 Type L non plug-in limit switches by Eaton's electrical sector are sold as complete assembled devices only with a wide array of operating head configurations. All switches are single-pole 1NO-1NC. Standards and Certifications Side and top rotary, side and top push or wobble operation CW, CCW or CW and CCW operating modes are field convertible Double break-make snap action contacts, same polarity each pole Captive saddle clamp terminals accept up to #12 wire Head can be mounted in any of four discrete positions, intervals of 90 UL Listed CSA Certified 2 DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-89 2 2 2.9 2 Non Plug-In Switches Product Selection 2 Complete Assembled Switches Single-Pole 1NO-1NC Operating Data--Nominal 2 2 Limit Switches Travel to Operate Contacts Operating Characteristics Side Rotary Operated Side Rotary Operated Travel to Reset Contacts Total Travel Force to Operate Contacts Minimum Return Force Catalog Number 3 in-lbs 4.5 in-oz 10316H187 1 Standard 10 4 50 Clockwise 20 12 140 1.1 in-lbs 3 in-oz 10316H700 Counterclockwise 20 12 140 1.1 in-lbs 3 in-oz 10316H701 2 2 2 Top Rotary Operated 2 2 Top Rotary Operated 1 2 2 Side Push Operated Side Push Operated 2 Adjustable pushbutton 0.07 in (1.8 mm) 0.03 in (0.8 mm) 0.29 in (7.4 mm) 4 lbs 8 oz 10316H621 2 Vertical roller-- 0.44 in (11.2 mm) dia. 0.07 in (1.8 mm) 0.03 in (0.8 mm) 0.29 in (7.4 mm) 4 lbs 8 oz 10316H284 2 Horizontal roller-- 0.44 in (11.2 mm) dia. 0.07 in (1.8 mm) 0.03 in (0.8 mm) 0.29 in (7.4 mm) 4 lbs 8 oz 10316H285 Pushbutton 0.04 in (1.0 mm) 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz 10316H281 2 Roller--0.44 in (11.2 mm) dia. 0.04 in (1.0 mm) 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz 10316H283 2 Roller--0.75 in (19.1 mm) dia. 0.04 in (1.0 mm) 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz 10316H577 Spring 10 6 15 1 in-lb 2.4 in-oz 10316H299 Nylon rod 10 6 15 2 in-lbs 2.4 in-oz 10316H296 Wire 10 6 15 2 in-lbs 2.4 in-oz 10316H484 Cat whisker 15 5 30 0.63 in-lb 1.7 in-oz 10316H341 2 2 Top Push Operated Wobble Operated 2 2 2 Top Push Operated Wobble Operated 2 Notes 1 For operating levers, see Page V8-T2-80. 2 For wobble operators, see Page V8-T2-80. 2 2 2 2 2 2 2 2 2 V8-T2-90 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.9 Limit Switches Non Plug-In Switches Technical Data and Specifications 2 Non Plug-In Switches 2 Description Specification Contact rating NEMA A600, R300 double break-make snap action contacts Electrical life 500,000 operations minimum Mechanical life 5,000,000 operations minimum at full load Conduit entrance 0.5 in (12.7 mm) NPT 2 2 2 Material of construction Zinc die cast Enclosure rating NEMA 1, 4, 13 Ambient operating temperature -20 to 200F (-29 to 93C) 1 Approximate shipping weight 2 lbs 2 2 2 Electrical Data--Maximum Contact Ratings per Pole 2 Current, Amperes AC Volts Make Volts, Amperes Break Cont. Thermal Ratings Make Break DC Volts DC Current, Ampere 2 2 NEMA A600, R300 Rating 120 60 6 10 7200 720 125 0.22 240 30 3 10 7200 720 250 0.11 480 15 1.5 10 7200 720 250 0.11 600 12 1.2 10 7200 720 250 0.11 2 2 2 Dimensions 2 Approximate Dimensions in Inches or Inches (mm) Side Rotary Operated Head with Switch 0.50 0.50 0.28 Side Pushbutton, Adjustable 1.75 1.44 0.09 0.25 Top Pushbutton 0.31 Sq. 3 1.16 3.875 2.84 2.34 1.56 1.16 1.55 2 3 A 0.5 1.59 0.50 0.1 0.31 Max. Adjustment 0.50 Pipe Tap 3 0.31 Sq. 1.0 0.5 2 Side Push, Vertical Roller 1.0 2 Dimension "A" 1.78 With 0.44 (11.2) dia. roller 1.78 (45.2) With 0.75 (19.1) dia. roller 2.09 (53.1) (2) 0.203 Dia. Holes for Front Mtg. (2) 10-32 Tapped Holes 0.375 Deep for Rear Mtg. Top Push Roller 0.31 Sq. 2.97 1.66 0.25 0.16 Wobble Operators 3 3 B 1.0 0.38 Dia. 0.5 2 2 2 Side Push Maintained Contact 1.31 2 A A C 0.50 Dimension "A" A B With 0.44 (11.2) dia. roller 2.03 (51.6) Wobble Spring With 0.75 (19.1) dia. roller 2.34 (59.4) 5.44 (138.2) 0.31 (7.9) 4 Notes 1 Ranges below 32F (0C) are based on absence of freezing moisture or water. 2 Contacts must be same polarity when both circuits are used. 3 Dimension from centerline of head to mounting surface is 0.78 in (20 mm). 4 Center to mounting surface. 0.08 (2.0) 0.25 (6.4) 2 2 2 0.81 (20.6) 2 0.81 (20.6) 2 0.81 (20.6) 2 Nylon Wobble Stick 4.5 (114.3) 2 2 C Wire Wobble Stick 12.5 (317.5) 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-91 2.10 2 Limit Switches Hazardous Location Limit Switches Contents Hazardous Location Limit Switches Description 2 Page Hazardous Location Limit Switches Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 V8-T2-93 V8-T2-94 V8-T2-91 2 2 2 2 2 2 2 Hazardous Location Limit Switches 2 Product Description Features Type LX, CX and CBX limit switches by Eaton's electrical sector are designed for extreme environmental service in NEMA 7-9 locations where the danger of an internal or external explosion of flammable gases, vapors, metal alloy or grain dust exists. Type CB provides excellent corrosion resistant properties in NEMA 4X applications. Markets served include mining, grain storage, forest products, petrochemical, pharmaceutical and waste and sewage management. 2 2 2 2 2 2 2 2 2 2 Sealed and unsealed versions available One-way gasket on sealed version keeps liquids out, yet allows a harmless release of gases in the event of an internal explosion Silicon bronze housing provides excellent corrosion resistant properties in extreme NEMA 4X applications Temperature buildup on limit switch surface is dissipated by housing design and materials used Utilizes the operating heads and internal switch mechanisms of the 10316 L non plug-in line Standards and Certifications cUL NEMA Ratings Comparison Switch Type LX CX CBX CB 1 NEMA 1, 4, 13 -- NEMA 4X -- -- NEMA 7 Division I, Class I, BCD -- NEMA 9 Division I, Class II, EFG DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. -- Note 1 Not rated for explosive locations. 2 2 2 2 2 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com V8-T2-92 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches Hazardous Location Limit Switches 2.10 Product Selection 2 Complete Assembled Switches with Spring Return Heads 1 2 Operating Data--Nominal Head Type Side Rotary Operated 2 Travel to Operate Contacts Travel to Reset Contacts Total Travel Force to Operate Contacts Minimum Return Force Body Type 2 Contacts Catalog Number 2 10316H1002 2 Standard, 10 Pre-Travel 3 10 4 50 3.0 in-lbs 4.5 in-oz Type LX Type CX Type CB 1NO-1NC 4 2NO 10316H1039 1NO and 1NC 4 10316H1049 2NC 10316H1059 1NO-1NC 4 10316H2200 1NO and 1NC 4 10316H2176 2NC 10316H2178 1NO-1NC 4 10316H2149 50 6.0 in-lbs 4.5 in-oz Side Push Operated 6 50 1.8 in-lbs 2.5 in-oz 10316H2168 2NC 10316H2159 Type LX 1NO-1NC 4 10316H1146 Type CX 1NO-1NC 4 10316H2197 Type LX 2NO 10316H1071 2NC 10316H1072 Type CX 2NO 10316H2179 Type CBX 2NC 10316H2160 2 2 Pushbutton 0.07 in (1.8 mm) 0.03 in (0.76 mm) 0.03 in (0.76 mm) 0.03 in (0.76 mm) 0.03 in (0.76 mm) 2 2 2 8 oz Type LX 1NO and 1NC 4 10316H1213 0.29 in (7.4 mm) 4 lbs 8 oz Type LX 1NO-1NC 4 10316H1192 4 lbs 8 oz Type LX 1NO-1NC 4 10316H1007 2 4 lbs 8 oz Type LX 1NO-1NC 4 10316H1194 2 0.29 in (7.4 mm) Vertical Roller, 0.75 in (19.1 mm) Diameter 0.07 in (1.8 mm) 2 4 lbs Vertical Roller, 0.44 in (11.2 mm) Diameter 0.07 in (1.8 mm) 2 0.29 in (7.4 mm) Adjustable Pushbutton 0.07 in (1.8 mm) 2 1NO-1NC 4 Neutral Position, 18 Pre-Travel 5 18 2 10316H2140 Narrow Differential 5 Pre-Travel 3 2 2 2NC Type CBX 5 2 0.29 in (7.4 mm) 2 2 2 Notes 1 Contact Eaton's Sensor Applications Engineering at 1-800-426-9184 for replacement contact blocks. 2 For operating levers, see Page V8-T2-80. Only levers with Nylatron rods or rollers should be used with explosion-proof limit switches. 3 Field convertible to clockwise only or counterclockwise only operation. 4 1NO-1NC contacts must be same polarity when both circuits are used--1NO and 1NC contacts have isolated poles and may be used on opposite polarity. 5 Neutral position switches operate one circuit in each direction. 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-93 2.10 2 Operating Data--Nominal Head Type Travel to Operate Contacts Top Push Operated Pushbutton 2 0.04 in (1 mm) 2 0.04 in (1 mm) 0.02 in (0.5 mm) Total Travel Force to Operate Contacts Minimum Return Force Body Type Contacts Catalog Number 0.28 in (7.1 mm) 4 lbs 8 oz Type LX 1NO-1NC 2 10316H1004 Type CX 1NO and 1NC 2 10316H2188 0.02 in (0.5 mm) Type LX 1NO-1NC 2 10316H1191 1NO and 1NC 2 10316H1212 Type LX 1NO-1NC 2 10316H1006 Type CBX 1NO-1NC 2 10316H2170 0.28 in (7.1 mm) 4 lbs 8 oz Roller, 0.44 in (11.2 mm) Diameter 2 0.04 in (1 mm) 2 2 Travel to Reset Contacts Adjustable Pushbutton 2 2 Hazardous Location Limit Switches Complete Assembled Switches with Spring Return Heads, continued 1 2 2 Limit Switches 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz Roller, 0.75 in (19.1 mm) Diameter 0.04 in (1 mm) Wobble Operated 0.28 in (7.1 mm) 4 lbs 8 oz Type LX 1NO-1NC 2 10316H1193 6 15 1 in-lb 2.4 in-oz Type LX 1NO-1NC 2 10316H1237 6 15 2 in-lbs 5.6 in-oz Type LX 1NO-1NC 2 10316H1009 Spring 10 3 2 0.02 in (0.5 mm) Nylon Rod 2 10 3 2 2 Technical Data and Specifications 2 Hazardous Location Limit Switches 2 2 2 2 2 2 2 2 Description Specification Material of construction LX, CX Cast aluminum die cast CB, CBX Silicon bronze Conduit entrance LX 1/2 in pipe tap CB, CBX, CX 3/4 in pipe tap Mounting Surface mount Enclosure rating LX, CX, CBX NEMA 7 Div. 1, Class I BCD; NEMA 9 Div. 1, Class II, EFG 4 CB, CBX NEMA 1, 4, 4X, 13 4 CX NEMA 1, 4, 13 4 Ambient operating temperature -20 to 200F (-29 to 93C) 5 Approximate shipping weight 2 LX 2 lbs CX 2.5 lbs 2 CB, CBX 6 lbs 2 2 2 Notes 1 Contact Eaton's Sensor Applications Engineering at 1-800-426-9184 for replacement contact blocks. 2 1NO-1NC contacts must be same polarity when both circuits are used--1NO and 1NC contacts have isolated poles and may be used on opposite polarity. 3 Travel with force applied at one-in (25.4 mm) radius. Applied at end of operator, travel is approximately 14. 4 A conduit seal-off kit is required for these switches 5 Ranges below 32F (0C) are based on absence of freezing moisture or water. 2 2 V8-T2-94 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.10 Limit Switches Hazardous Location Limit Switches Electrical Data--Maximum Contact Ratings, per Pole Current, Amperes AC Volts Make Volt Amperes Break Cont. 1 Make Break DC Volts DC Current, Ampere 2 2 1NO-1NC Switches 2 NEMA A600, R300 rating 120 60 6 10 7200 720 125 0.2 240 30 3 10 7200 720 250 0.1 480 15 1.5 10 7200 720 250 0.1 600 12 1.2 10 7200 720 250 0.1 3 5 3600 360 120 0.1 2 2 2 All Other Switches, B600 120 30 240 15 1.5 5 3600 360 240 0.05 480 7.5 0.75 5 3600 360 240 0.05 600 6 0.60 5 3600 360 240 0.05 2 2 2 Dimensions 2 Approximate Dimensions in Inches or Inches (mm) Type LX Switch with Side Rotary Head 2.81 0.69 0.31 1/4-20 Pipe Tap 3.38 0.31 Deep Both Sides 4 0.27 Dia. 2 Holes 0.31 Sq. 1.19 2.25 Top Pushbutton Head 5 5 0.31 Sq. 1.0 0.5 0.27 Dia. 0.875 2 Holes 5/16-18 Pipe Tap 0.56 Deep Both Sides 0.50 Pipe Tap 1.44 2.25 1.44 1/4-20 Pipe Tap 0.28 Deep Both Sides 0.50 5.22 Side Pushbutton Head 2 Side Push, Vertical Roller Head 0.5 1.59 0.50 2 5 A 1.0 2 2 Dimension "A" With 0.44 (11.2) dia. roller 1.78 (45.2) With 0.75 (19.1) dia. roller 2.09 (53.1) 0.25 2 2 2 Type CX, CB and CBX Switches with Side Rotary Head Adjustable Top Pushbutton Head 3.08 0.31 Sq. 0.10 0.31 Max. Adjustment .50 .277 .685 2 Wobble Operators B 2 A 0.257 Dia. .325 4 Mtg. Holes 3.50 5.35 3/4-14 Taper Pipe Tap 4.165 2.36 3.00 2.54 2.60 C 1.69 0.50 .945 Type CX Type CBX Type CB 0.25 A B 3 Notes 1 1NO-1NC contacts must be same polarity when both circuits are used-- 1NO and 1NC contacts have isolated poles and may be used on opposite polarities. 2 Dimension from centerline of head to mounting surface is 0.78 in (20 mm). 3 Center to mounting surface. 1.44 0.09 0.31 Sq. 0.5 1.56 0.1 0.31 Max. Adjustment 5.44 (138.2) Top Push Roller Head 0.16 2 4.5 (114.3) 2 2 2 0.31 (7.9) 0.94 (23.9) 2 0.25 (6.4) 0.94 (23.9) Nylon Red 5 2 C Wobble Spring Adjustable Side Pushbutton Head 2 2 2 1.0 A 2 0.50 2 Dimension "A" With 0.44 (11.2) dia. roller 2.03 (51.6) With 0.75 (19.1) dia. roller 2.34 (59.4) Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2 2 V8-T2-95 2.11 2 Limit Switches Special Purpose Limit Switches Contents Special Purpose Limit Switches Description 2 Page Special Purpose Limit Switches Product Selection Roller Lever Switches . . . . . . . . . . . . . . . . . Rotating Shaft Switches . . . . . . . . . . . . . . . Pneumatic Time Delay Switches . . . . . . . . Precision Switches . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 2 2 V8-T2-97 V8-T2-97 V8-T2-98 V8-T2-98 V8-T2-99 V8-T2-101 2 2 2 2 2 Special Purpose Limit Switches 2 Product Description Features Special Purpose (Type F), Rotating Shaft (Type J), Pneumatic Time Delay (Type LP) and Precision and Cabinet Door Interlock (Type PS) Limit Switches from Eaton's electrical sector serve a variety of special purpose industrial applications for MRO and User Replacement requirements. 2 2 2 2 2 2 UL Listed CSA Certified (PS and J only) Standards and Certifications Type F UL Listed Type J UL Listed CSA Certified Type LP UL Listed Type PS UL Recognized CSA Certified 2 2 2 DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 2 2 2 2 2 2 2 2 2 For the most current information on this product, visit our Web site: www.eaton.com V8-T2-96 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com 2.11 Limit Switches Special Purpose Limit Switches Product Selection 2 Roller Lever Switches Roller Lever 2 Type F Switches 1 Operator Circuit Travel to Operate Contacts Travel to Reset Contacts Total Travel Over-Travel Catalog Number Roller lever (CW and CCW operation, spring return) 1NO-1NC 40 35 65 25 10316H18 2 2 2 2NO-2NC 17 6 60 43 2 10316H320 2 2 2 Rotating Shaft Switches Type J Rotating Shaft Limit Switches allow the shaft to be rotated a preset number of revolutions (adjustable from 1/2 to 100 with an accuracy of 1/20 of a turn) before the contacts will switch. A second set of Rotating Shaft 2 contacts will trip when reaching a preset limit in the opposite direction. These switches are typically used in crane and hoist applications to provide end of travel stops for the hook assembly. 2 2 2 2 Type J Switches Shaft to Cam Ratio Max. Turns to Trip Contacts Min. Turns to Trip Contacts Over-Travel Before Resetting Contacts Reversal After Tripping to Reset Contacts 103:1 100 input shaft turns 1/2 input shaft turns 103 input shaft turns max. 1/8 input shaft turns min. 2 Circuit 2 Enclosure Rating Catalog Number 2NC NEMA 1 10316H50 2 2 2NO-2NC 3 NEMA 4 10316H54 3 2 2 Notes 1 Replacement operator head is available with part number 86-862-22. Replacement roller lever is available with part number 24-1712. Replacement key pin and washer for roller is available with part number 16-906. 2 For replacement NO contacts, order 17-1403; NC contacts, order 17-702. 3 10316H54 has factory set circuits, but is easily convertible to any of three circuits (2NO-2NC, 4NO or 4NC). Full instructions enclosed with every switch. 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-97 2.11 Limit Switches Special Purpose Limit Switches 2 Pneumatic Time Delay Switches 2 Pneumatic Time Delay Type LP Switches 2 2 Operator Total Travel Pre-Travel Circuit Timed Contacts Direction of Rotation 2 Catalog Number Side rotary (Spring return to center) 1 50 10 1NO-1NC ON delay CW 10316H1580 CW and CCW 10316H1600 CW 10316H1610 CW and CCW 10316H1630 2 OFF delay 2 2 2 2 2 Precision Switches Cabinet Door Interlock Type PS Switches Operator 2 Circuits-- SPDT 1NO-1NC Catalog Number Circuits-- DPDT 2NO-2NC Catalog Number Operator Only Catalog Number Precision Switch Devices 2 Precision switch only 10316H89 10316H2000 -- 2 Pushbutton with oiltight plunger -- 10316H2006 -- Roller with oiltight plunger perpendicular to mounting holes -- 10316H2012 -- 2 Roller with oiltight plunger in line with mounting holes 10316H110 -- -- 6 in lever with top and right-hand mounting bracket 10316H113 -- 10316H143 2 6 in lever with top and left-hand mounting bracket -- -- 10316H144 Roller lever with top and right-hand mounting bracket 10316H119 -- 10316H145 2 Roller lever with top and left-hand mounting bracket 10316H122 -- 10316H146 2 One way roller lever with top and right-hand mounting bracket -- -- 10316H147 One way roller lever with top and left-hand mounting bracket -- -- 10316H148 2 Cabinet Door Interlocks Precision switch only 10316H828 10316H829A -- 2 Cabinet door interlock operator with one precision switch and with red (defeated 3) indicator 10316H1028 10316H2042 10316H150 2 Cabinet door interlock operator with two each of listed precision switches and with red (defeated 3) indicator 10316H1029 -- -- 2 Notes 1 Requires an operating lever, see Page V8-T2-80. 2 Field convertible. 3 The plunger exposes a red band when pulled out to indicate that interlock is defeated. 2 2 2 2 2 2 2 2 2 V8-T2-98 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches Special Purpose Limit Switches 2.11 Technical Data and Specifications 2 Special Purpose Limit Switches Specification 2 NEMA 4 2 Description Roller Lever Switches--Type F Enclosure rating Operating temperature 0 to 180F (-18 to 82C) Conduit entrance 0.5 in NPT Shipping weight 4.0 lbs 2 2 Rotating Shaft Switches--Type J 2 Shipping weight NEMA 1 models 5.5 lbs NEMA 4 models 13 lbs 2 2 Pneumatic Time Delay Switches--Type LP Timing range 0.05 to 60 seconds ON delay function Timing begins when lever is actuated and held OFF delay function Timing begins when lever is released Repeat accuracy 1 With 15 second or higher interval between timing periods: 10% of setting maximum With less than 15 second interval between timing periods: 25% of setting maximum Operating frequency 250 operations per minute maximum Enclosure rating NEMA 4, 13 Ambient operating temperature 32 to 150F (0 to 65C) Conduit entrance 0.5 in NPT Shipping weight 2 lbs 2 2 2 2 2 2 Note 1 To maintain operating accuracy during the timing cycle, the switch lever must be faster than the timed setting. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-99 2.11 Limit Switches Special Purpose Limit Switches 2 Type F--Maximum Ampere Ratings 2 Circuit State 120 240 480 600 120 240 600 1NO-1NC Make 60 30 20 15 -- -- -- Break 6 3 1.5 1.2 2.2 1.1 0.40 Make 40 20 10 8 -- -- -- Break 15 10 6 5 0.5 0.2 0.02 AC Volts 2 2 2NO-2NC DC Volts 2 2 Type J--Maximum Ampere Ratings 2 State 2 2 AC Volts DC Volts 120 240 480 600 120 240 600 Make 60 30 15 12 2.2 1.1 -- Break 6 3 1.5 1.2 2.2 1.1 -- Continuous 1 10 10 10 10 10 10 -- 2 Type LP-- Electrical Data, Maximum Contact Ratings/Pole 2 AC Volts Current, Amperes Make Volt Amperes Break Cont. 1 Make Break DC Volts DC Current Amperes 2 All Switches 1NO-1NC 2 120 60 6 10 7200 720 120 0.2 2 240 30 3 10 7200 720 240 0.1 480 15 1.5 10 7200 720 240 0.1 600 12 1.2 10 7200 720 240 0.1 2 2 NEMA A600, R300 Rating Type PS--Maximum Ampere Ratings DC Volts 2 AC Volts 2 Type 2 Single-pole 2 Double-pole 2 2 State 120 Double Throw 240 480 600 120 240 600 Heavy-Duty 1/2 hp, 250 Vac Maximum Make 40 20 10 8 2.0 0.5 0.1 Break 15 10 6 5 0.5 0.2 0.02 Make 30 15 8 6 0.5 0.2 0.2 Break 3 1.5 1 0.8 0.2 0.1 -- Note 1 Thermal rating. Valid only if switch does not have to make or break. 2 2 2 2 2 2 2 2 V8-T2-100 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com Limit Switches Special Purpose Limit Switches 2.11 Dimensions Approximate Dimensions in Inches (mm) 2 Roller Lever Switches 2 2 Type F 3.00 (76.2) 1- & 2-Pole 3.31 (84.1) 3-Pole 6.88 (174.8) 1- & 2-Pole 7.69 (195.3) 3-Pole 1.31 (33.3) 1- & 2-Pole 1.13 (28.7) 3-Pole 2 2 2.69 (68.3) 1- & 2-Pole 3.00 (76.2) 3-Pole 2 2 3.66 (93.0) 1- & 2-Pole 3.75 (95.3) 3-Pole 2 2 2 Approximate Dimensions in Inches only 2 Rotating Shaft Switches Type J--NEMA 1 Models Type J--NEMA 4 Models 2 2 2 2 2 2 2 Pneumatic Time Delay Switches 2 Type LP 2 2 2 2 2 2 2 2 2 2 2 Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com V8-T2-101 2.11 2 2 2 2 2 2 Limit Switches Special Purpose Limit Switches Approximate Dimensions in Inches [mm] Precision Switches Type PS 0.156 [4] Dia. 0.81 [21] 0.157 [4] 2 Mtg. 0.137 [3.5] Holes Stroke 2.125 [54] 0.199 [5] 2.47 [63] 0.25 [6.4] 1.05 [26.5] 0.345 [8.7] 1.89 [48] Contact Block Mechanism 15/32-32 1.05 [26.6] Thread 0.97 [25] 2 2 2 2 2 2 2 3.84 [98] 2.69 [68] 0.78 [20] 2.69 [68] 2.31 [59] 1.2 [26] 0.81 2.47 [63] [21] Pushbutton Type 2 [11.1] 1.54 Dia. 0.78 [13.8] 1.45 [20] [11.5] 1.20 [30.5] 2.47 [63] 0.81 [21] Push Roller Type 0.31 [8] 6.0 [152] 1.22 [31] 0.16 [4.3] Dia. 4 Holes #10-32 Tap 2 Holes 0.16 [4.3] Dia. 4 Holes 0.25 0.56 [14] [6.4] 0.88 [22] 1.03 [26] Cabinet Door Type Two Contact Blocks 0.69 [17.5] 2.31[59] 2.81 [71] 0.5 [13] 2.59 [66] 0.97 [24.6] 2.69 2.31[68] [59] 6 in Lever Type 0.56 [14] 0.38 [9.5] 1.38 [35] 0.16 [4.3] Dia. 4 Holes 1.84 [47] 0.38 [9.5] 1.0 [25] 1.84 [47] 0.16 [4.3] Dia. 4 Holes 0.69 [17.5] 0.69 [17.5] 0.5 [13] 2.31 [59] 2.81 [71] 0.97 [24.6] One Way Roller Type 0.5 [13] Cabinet Door Type One Contact Block 2.31[59] 2.81 [71] 0.97 [24.6] Roller Lever Type 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V8-T2-102 0.88 [22] 0.25 0.16 [4.3] [6.4] Dia. 2 Holes #10-32 Tap 2 Holes 1.03 [26] Volume 8--Sensing Solutions CA08100010E--May 2013 www.eaton.com