H VDE 0884 VIORM = 630 V peak Option for Plastic Optocouplers Technical Data Option 060 Description Optocouplers are frequently used to provide high voltage insulation. Because optocouplers perform this safety function, they are regulated by many country safety agencies, both at the component level and the equipment level. With Option 060, the products are tested according to VDE 0884 (June 1992 Revision) at VIORM = 630 V peak. HP also offers other various VDE 0884 approved products at different levels of VIORM such as VIORM = 1414 kV peak (HCNWXXXX series) and VIORM = 891 V peak (HCPL-JXXX series). Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, for a detailed description of VDE 0884 and the partial discharge tests for production and type testing. availablility of this option for optocouplers not listed. Ordering Information Specify Part Number followed by Option Number. Example Option 060 is available on the following products. HCPL-2211 HCPL-2219 HCPL-2400 HCPL-261N HCPL-3120 HCPL-4503 HCPL-4506 HCPL-2212 HCPL-2300 HCPL-261A HCPL-2611 HCPL-3150 HCPL-4504 HCPL-4701 HCPL-3120#060 Marketing Information EXAMPLE: HCPL-3120 #060 HP 3120V 9624 4 DIGITS DATE CODE Contact your local HP Sales Representative concerning Insulation Related Specifications Parameter Minimum External Air Gap (External Clearance) Minimum External Tracking (External Creepage) Minimum Internal Plastic Gap (Internal Clearance) Tracking Resistance (Comparative Tracking Index) Isolation Group 1-480 Symbol L(101) Value 7.1 Units mm L(102) 7.4 mm 0.08 mm 200 V CTI IIIa Conditions Measured from input terminals to output terminals, shortest distance through air. Measured from input terminals to output terminals, shortest distance path along body. Through insulation distance, conductor to conductor, usually the direct distance between the photoemitter and photodetector inside the optocoupler cavity. DIN IEC 112/VDE 0303 Part 1 Material Group (DIN VDE 0110, 1/89, Table 1) 5965-3572E VDE 0884 Insulation Related Characteristics (Option 060) *85C HCPL-2211, HCPL-2212, HCPL-2219, HCPL-2300, HCPL-2400, HCPL-2611, HCPL-261A, HCPL-261N, HCPL-4701. **100C HCPL-3120, HCPL-3150, HCPL-4503 HCPL-4504, HCPL-4506. Description Symbol Characteristic Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage 300 V rms I-IV for rated mains voltage 450 V rms I-III Climatic Classification 55/85/21* 55/100/21** Pollution Degree (DIN VDE 0110/1.89) 2 Maximum Working Insulation Voltage VIORM 630 Input to Output Test Voltage, Method b VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, VPR 1181 Partial Discharge < 5 pC Input to Output Test Voltage, Method a VIORM x 1.5 = VPR, Type and Sample Test, VPR 945 tm = 60 sec, Partial Discharge < 5 pC Highest Allowable Overvoltage (Transient Overvoltage, tini = 10 sec) VIOTM 6000 Safety Limiting Values (Maximum values allowed in the event of a failure, also see Thermal Derating curve, Figure 1.) Case Temperature TS 175 Input Current IS,INPUT 230 Output Power PS,OUTPUT 600 Insulation Resistance at TS, VIO = 500 V RS 109 Units V peak V peak V peak V peak C mA mW Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section (VDE 0884), for a detailed description. OUTPUT POWER - PS, INPUT CURRENT - IS Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application. 800 PS (mW) 700 IS (mA) 600 500 400 300 (230) 200 100 0 0 25 50 75 100 125 150 175 200 TS - CASE TEMPERATURE - C Figure 1. Thermal Derating Curve, Dependence of Safety Limiting Value with Case Temperature per VDE 0884. 1-481