Real time clock module
Actual size
Block diagram
Overview
BUS
INTERFACE
CIRCUIT
CE 1
CLK
DATA
32.768 kHz
CE 0
CONTROL
REGISTER
SHIFT REGISTER
A
LARM REGISTER
TIMER REGISTER
CLOCK and
CALENDAR
INTERRUPTS
CONTROLLER
OUTPUT
CONTROLLER
DIVIDER
CONTROL LINE
FOUT
/ TIRQ
/ AIRQ
OSC
FCON
32.768 kHz frequency output function
• FOUT pin output (C-MOS output), CL=30 pF
• Output frequency is selectable from 1/30Hzto 32.768kHz
(32 Values)
Timer function
• Timer function which can be set up between
1/4096 second and 255 minutes.
• It is recorded automatically to TF-bit at the time of event
occurrence, and it’s possible to output with /TIRQ pin output
(open-drain output).
• Selectable one time mode or repeat mode.
Alarm function
Alarm function can be set to any combination of day of
week, hour, or minute.
•It is recorded automatically to AF-bit at the time of event
occurrence, and it’s possible to output with /AIRQ pin output
(open-drain output).
Functions are compatible with RTC-4574SA/JE/NB.
Pin Function
T erminal connecti on
/
External dime nsion
s
Unit:mm
)
Signal Nam e Input / Ou tp ut Function
CE0 Input
The chip enabled input pin 0. (Built-i n pull-d own resi st ance)
When both CE0 and CE1 pins are at the “Hlevel , access to this
Real time clock module becomes possible.
CE1 Input
The chip enabled input pin 1.
W hen t he CE1 pin is at the HI GH l e vel , the FOUT pin is in th e out put sta te.
CLK Input The shift clock input pin for serial data transfer.
DATA Bi-directional The data input / output pin for serial data transfer.
FOUT Output
This pin outputs the reference clock signal at 32.768 kHz ( C-MOS output ).
High impedance at the time of output off.
FCON Input The input pin for the FOUT output control.
/ AIRQ Output The open drain output pin for alarm and tim e update interrupts.
/ TIRQ Output The open drain output pin for timer interrupt.
VDD
-
Connected to a positive power supply.
GND
-
Connected to a ground.
RX4574LC
1. N.C. 12. VDD
2. N.C. 11. CE1
3. /TIRQ 10. CLK
4. /AIRQ 9. DATA
5. FCON 8. CE0
6. FOUT
0.5
2.4
3.6
1.2Max.
2.8 7. GND
VSOJ12pin
S
p
ecifications
(
characteristics
)
Refer to a
pp
lication manual for details.
Recommended Operating Conditions
Item Symbol Conditions Min. T yp. Max. Unit
Power voltage VDD
-
1.6 3.0 5.5 V
Clock voltag e VCLK
-
1.3 3.0 5.5 V
Operating
temperature TOPR
-
-40 +25 +85
C
Frequency characteristics
Item Symbol Conditions Rating Unit
Frequency
tolerance f/f Ta=+25C
VDD=3.0V 523* 106
Oscillation
Start-up time tSTA
Ta=+25C
VDD=1.6V 1Max. s
Ta=-40Cto+85
C
VDD=1.6V 3Max. s
*Equivalent to 1 minute of monthly deviation
Current consumption characteristics Ta=40Cto+85C
Item Symbol Conditions Min. Typ. Max. Unit
Current
Consumption
IBK CE0,CE1=GND
FOUT;output OFF
(Hi-z)
VDD
=5V
0.45 0.9
µA
VDD
=3V
0.35 0.7
I32k
CE0=GND
CE1=VDD
FOUT;
32.768kHz output ON
CL=30pF
VDD
=5V
8.0 20.0
µA
VDD
=3V
5.0 12.0
Small size, low profile model package
SERIAL-INTERFACE REAL TIME CLOCK MODULE
RX - 4574LC
Built in frequency adjusted 32.768 kHz crystal unit.
Interface Type : 3-wire serial interface
Operating voltage range : 1.6Vto5.5V
Wide Timekeeper voltage range : 1.3Vto5.5V
Low backup current : 0.35A/3V(Typ.)
32.768 kHz frequ ency output fun ction : C-MOS output With Contr ol Pin
The various functions include full calendar, alarm, timer.
Product Number (Please contact us)
RX-4574LC : Q414574C2000300
*Stop using the glue
Any glue mus t never use it after s oldering LC-pack age to a circuit board.This product
has glass on t he back side of a package.When glue i nvasions between circ uit board
side and glass side, then glass cracks by thermal expansion of glue.In this case a
crystal oscillation stops.Consider glue abolition or glue do not touch to LC-package
PROMOTION OF ENVIRONMENTAL MANAGEMENT SYSTEM
CONFORMING TO INTERNATIONAL STANDARDS
At Seiko Epson, all environmental initiatives operate under the
Plan-Do-Check-Action (PDCA) cycle designed to achieve continuous
improvements. The environmental management system (EMS)
operates under the ISO 14001 environmental management standard.
All of our major manufacturing and non-manufacturing sites, in
Japan and overseas, completed the acquisition of ISO 14001
certification.
WORKING FOR HIGH QUALITY
In order provide high quality and reliable products and services
than meet customer needs,
Seiko Epson made early efforts towards obtaining ISO9000 series
certification and has acquired ISO9001 for all business
establishments in Japan and abroad. We have also acquired ISO/TS
16949 certification that is requested strongly by major automotive
manufacturers as standard.
Explanation of the mark that are using it for the catalog
Pb free.
Complies with EU RoHS directive.
*About the products without the Pb-free mark.
Contains Pb in products exempted by EU RoHS directive.
(Contains Pb in sealing glass, high melting temperature type solder or other.)
The products have been designed for high reliability applications such as Automotive.
Seiko Epson Corporation
Notice
This material is subject to change without notice.
Any part of this material may not be reproduced or duplicated in any form or any means without the written permission of Seiko Epson.
The information about applied circuitry, software, usage, etc. written in this material is intended for reference only. Seiko Epson does
not assume any liability for the occurrence of infringing on any patent or copyright of a third party. This material does not authorize the
licensing for any patent or intellectual copyrights.
When exporting the products or technology described in this material, you should comply with the applicable export control laws and
regulations and follow the procedures required by such laws and regulations.
You are requested not to use the products (and any technical information furnished, if any) for the development and/or manufacture of
weapon of mass destruction or for other military purposes. You are also requested that you would not make the products available to
any third party who may use the products for such prohibited purposes.
These products are intended for general use in electronic equipment. When using them in specific applications that require extremely
high reliability, such as the applications stated below, you must obtain permission from Seiko Epson in advance.
/ Space equipment (artificial satellites, rockets, etc.) / Transportation vehicles and related (automobiles, aircraft, trains,
vessels, etc.) / Medical instruments to sustain life / Submarine transmitters / Power stations and related / Fire work equipment
and security equipment / traffic control equipment / and others requiring equivalent reliability.
All brands or product names mentioned herein are trademarks and/or registered trademarks of their respective.
ISO 14000 is an international standard for environmental
management that was established by the International
Standards Organization in 1996 against the background of
growing concern regarding global warming, destruction of
the ozone layer, and global deforestation.
ISO/TS16949 is the international standard that added the
sector-specific supplemental requirements for automotive
industry based on ISO9001.