85
Compensated
85C www.meas-spec.com April 2012
2/4
PERFORMANCE SPECIFICATIONS
Supply Current: 1.5mA
Ambient Temperature: 25°C (unless otherwise specified)
PARAMETERS 005PSI ≥015PSI UNITS NOTES
MIN TYP MAX MIN TYP MAX
Span 75 100 150 75 100 150 mV 1
Zero Pressure Output -2.0 0 2.0 -1.0 0 1.0 mV 2
Pressure Non Linearity -0.20 0.20 -0.10 0.10 %Span 3
Pressure Hysteresis -0.10 ±0.02 0.10 -0.05 ±0.02 0.05 %Span
Repeatability ±0.02 ±0.02 %Span
Input Resistance 2.0K 3.5K 5.8K 2.0K 3.5K 5.8K Ω
Output Resistance 4.0K 6.0K 4.0K 6.0K Ω
Temperature Error – Span -1.0 1.0 -0.75 0.75 %Span 4
Temperature Error – Offset -2.5 2.5 -0.50 0.50 %Span 4, 5
Thermal Hysteresis – Span -0.25 ±0.05 0.25 -0.25 ±0.05 0.25 %Span 4
Thermal Hysteresis – Offset -0.25 ±0.05 0.25 -0.25 ±0.05 0.25 %Span 4
Long Term Stability – Span ±0.10 ±0.10 %Span/Year
Long Term Stability – Offset ±0.25 ±0.10 %Span/Year
Supply Current 0.5 1.5 2.0 0.5 1.5 2.0 mA 6
Output Load Resistance 5M 5M Ω 7
Insulation Resistance (50Vdc) 50M 50M Ω 8
Output Noise (10Hz to 1KHz) 1.0 1.0 uV p-p
Response Time (10% to 90%) 0.1 0.1 ms
Pressure Overload 3X 3X Rated
Pressure Burst 4X 4X Rated 9
Compensated Temperature 0 +50 -20 +85 °C
Operating Temperature -20 +70 -40 +125 ºC 10
Storage Temperature -50 +125 -50 +125 ºC 10
Media – Pressure Port Liquids and Gases compatible with 316/316L Stainless Steel
Media – Reference Port Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber, and 316/316L
Stainless Steel
Notes
1. For amplified output circuits, 3.012V ±1% interchangeability with gain set resistor. See application schematic.
2. Measured at vacuum for absolute (A), ambient for gage (G).
3. Best fit straight line.
4. Over the compensated temperature range with respect to 25°C.
5. 15psi range sensors have a temperature error – offset of ±0.75% (max).
6. Guarantees output/input ratiometricity.
7. Load resistance to reduce measurement errors due to output loading.
8. Between case and sending element.
9. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
10. Maximum temperature range for product with standard cable and connector is -20 to +105°C.