Nominal capacity @ 1 mA, to 2V 1.7 Ah
Rated voltage 3.6 V
Maximum recommended continuous current 10 mA
Maximum pulse current capability 50 mA
Weight 21 g (0.74 oz)
Volume 8.2 cc
Operating temperature range -55ºC to +85ºC
Li metal content approx. 0.5 g
U.L. Component Recognition, MH 12193
TERMINAL MATERIAL : TIN PLATED NICKEL
CATALOGUE NO. : 15-5935-41500
TECHNICAL DATA
(Typical values @+25ºC for batteries stored for one year or less)
International size reference: 1/6D, ER32L100
MODEL TL-5935
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
ORDERING NO.
iXtra - Long Term High Performance
ECN 1501879 Rev. B 11/08
Page 1 of 2
DISCHARGE CHARACTERISTICS @ +25ºC
1.1 K
~3 mA
(1.7 Ah)
3.6 K
~1 mA
(1.7 Ah)
6.8 K
~0.5 mA
(1.65 Ah)
18 K
~0.2 mA
(1.59 Ah)
100 K
~36 µA
(1.51 Ah)
180 K
~20 µA
(1.32 Ah)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
1 10 100 1000 10000 100000
Hours
Volts
VOLTAGE VS. TEMPERATURE
3 mA
1 mA
0.5 mA
0.2 mA
30 µA
20 µA
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.6
3.7
-60 -40 -20 0 20 40 60 80
ºC
Volts CAPACITY VS. CURRENT
-40°C
-30°C
0°C
25°C
50°C
85°C
0.01 0.1 1
0.5
0.7
0.9
1.1
1.3
1.5
1.7
mA
Ah
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
Fast voltage recovery after long term storage and/or usage
High energy density
High and stable operating voltage
Low self discharge rate
Wafer construction
Hermetic glass-to-metal-sealing
Non-flammable electrolyte
CELL FEATURES
TL-5935
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
iXtra - Long Term High Performance
ECN 1501879 Rev. B 11/08
Page 2 of 2
MAIN APPLICATIONS
Utility meters (elect., water &
gas)
Automatic meter reading
RF systems
Sensors & monitoring systems
Tracking systems
Wireless security systems
Automotive electronics
Industrial electronics
Ultra Low Power
(
ULP
)
Cells should be stored in a
clean & dry (less than 30 %
RH) area
STORAGE CONDITIONS
For updated information please visit
our website www.tadiranbat.com
VOLTAGE RESPONSE AFTER STORAGE
After 1 year
After 2 years
After 5 years
After 10 years
2.6
2.7
2.8
2.9
3.0
3.1
3.2
3.3
3.4
3.5
0 200 400 600 800 1000 1200
msec
Volts
VOLTAGE RESPONSE
After 1 year
After 2 years
After 5 years
After 10 years
3.1
3.2
3.3
3.4
0 20 40 60 80 100 120
msec
Volts VOLTAGE RESPONSE
After 1 year
After 2 years
After 5 years
After 7 years
3.1
3.2
3.3
3.4
0 20 40 60 80 100 120
msec
Volts
Pulse applied: 10 mA for 100 msec
Temperature: RT
Background current: 7 µA
Pulse applied: 10 mA for 100 msec
Temperature: RT
Background current: 15 µA
Pulse applied: 10 mA for 1 sec
Storage: RT
Background current: None