Push-Pull connectors Introduction This catalog presents the push-pull connectors ranges for industrial applications. These products are particularly suitable for high reliability and high quality applications where a simple yet fast method to connect/disconnect is required. Also suitable for high endurance and ease of operation in very limited spaces. The aesthetics of the product allows for perfect integration on front panel equipments. SOURIAU offers 3 main series of metallic circular connectors : * JBX series : basic push-pull series for signal transmission * JKX series : environmental version of the JBX series sealed to IP68 * JAX series : complementary range including coaxial contact layouts. Contents Where and why push-pull................................................................................................3 Selection guide.................................................................................................................4 JBX series * Main features - Part number system.................................................................................5 * Shell types and dimensions..........................................................................................6-8 * Keying..............................................................................................................................9 * Contact layouts.........................................................................................................10-12 * Options...........................................................................................................................13 * Technical characteristics................................................................................................14 * Wiring and assembly instructions..............................................................................15-19 JAX series * Main features - Part number system...............................................................................20 * Shell types and dimensions............................................................................................21 * Contact layouts..............................................................................................................22 * Suffix for cable outside diameter - Options...................................................................23 * Technical characteristics................................................................................................24 * JAX camac series.....................................................................................................25-26 * Wiring and assembly instructions.............................................................................27-30 JKX series * Main features - Part number system...............................................................................31 * Shell types and dimensions............................................................................................32 * Keying - contact layouts.................................................................................................33 * Options...........................................................................................................................34 * Technical characteristics................................................................................................35 * Wiring and assembly instructions..............................................................................36-39 JBX series-sealed version size 2 * Main features - Part number system...............................................................................40 * Shell types and dimensions............................................................................................41 * Keying - contact layouts.................................................................................................42 * Technical informations....................................................................................................43 Accessories - Piece parts.........................................................................................44-46 Toolings......................................................................................................................47-48 More about our know-how.............................................................................................49 Requirement form...........................................................................................................50 Conversion table.............................................................................................................51 All dimensions are in mm 2 Push-Pull connectors Where and Why push-pull ? Medical Extremely fast and easy to use A thousand matings/ unmatings. Quality aesthetics for more value added on the equipment Space saving Professional audio-video Instrumentation GPS Telecommunications 3 Selection Guide Push-Pull Unsealed Sealed Multipin Coaxial Multipin Crimp or PCB contacts Solder Not keyed Keyed Keyed 1 to 14 contacts 2 to 30 contacts 2 to 30 contacts Solder, crimp or PCB contacts Keyed Keyed 2 to 10 contacts until 19 contacts UL approved JAX series JBX series JKX series Sealed JBX size 2 Shell material Brass Brass Brass Brass Insulator material Tefzel for coaxial contact Nylatron for multipin layout Fortron Peek for layout with contacts of 0.5 mm of O Fortron Peek for layout with contacts of 0.5 mm of O Fortron Peek for layout with contacts of 0.5 mm of O Shielding Shielded (65 dB up to 100 MHz) Shielded (55 dB up to 100 MHz) Shielded (55 dB up to 100 MHz) Shielded (55 dB up to 100 MHz) Endurance > 1000 cycles > 1000 cycles > 1000 cycles > 1000 cycles Current rating up to 30 A up to 30 A up to 15 A up to 30 A Temperature range - 40C ; + 125C (- 40F ; + 257F) - 50C ; + 125C (- 58F ; + 257F) - 50C ; + 125C (- 58F ; + 257F) - 40C ; + 80C (- 40F ; + 176F) Protection index IP 40 IP 40 IP 68 when mated IP 67 Specific version JAX Camac connectors (coaxial, size 00) (optional sealed version : consult us) Push-pull locking system The locking of the plug into the receptacle is achieved by a simple axial push on the outer shell. Connection cannot be broken by pulling the cable or any other parts of the plug than the outer shell. 4 To unmate the plug from the receptacle, just pull axially the outer shell. JBX Series Key features JBX Series * Mechanically keyed : ensures correct polarisation and alignment. * Contact layouts from 2 to 30 contacts. * Wire gauges range from 30 AWG to 12 AWG. * High contact density in a small space. * Contact termination in either crimp, solder or PCB contacts. User advantages Blister packaging 6-collet cluster Removable contacts Allows a wide range of cable diameter applications for a single connector. Reduces inventory variations Available crimp versions allow easier wiring and maintenance. Part number system JBX Basic series FD 1 G 05 M Shell type FD-FC-ER-EA-SR-PC-ED-EP-EZ Shell size 00 - 0 - 1 - 2 - 3 Keying G - J - A - B & customs are available Contact layout 02 ---------- 30 Contact type M : pin Contact termination C : crimp ; S : solder ; P* : straight PCB tails ; Q* : 90 PCB tails ; W : 0.7 mm clipped solder Material & surface plating S : Outer shell in brass alloy with chrome over nickel C S D F : socket N : Outer shell in brass alloy with black plating D : Obligatory suffix S : Insulator in PPS P : insulator in PEEK Options M : Connector with backnut for protective boot - Protective boot to order separately page 13 R : Red dot (possible for FD, FC, PC, SR, ER, ED, EZ only) * For receptacles with female contacts only 5 S M JBX Series Shell types ER : fixed receptacle,front panel mounting, fixed front flange FN : straight plug with cable clamping & lanyard EA : fixed receptacle, back or front panel mounting, double nuts fixing (appropriate with 90 contacts for PCB) FD : straight plug with cable clamping EP : fixed receptacle, back panel mounting, fixed rear panel flange (appropriate with 90 contacts for PCB) ED : fixed receptacle, protruding shell, fixed front flange SR : fixed receptacle with cable clamping, front panel mounting, fixed front flange FC : 90 elbow plug with cable clamping PC : cable mounted receptacle EZ : straight receptacle for PCB SA : fixed receptacle with cable clamping, front or back panel mounting 6 JBX Series Dimensions* EA : Double nut receptacle* Size 00 0 1 2 3* Size A 14 19 21 24 28 A B 6 8 10 10 12 B C 0.8 1.2 1.5 1.8 2.0 C OD 8 OD 10 14 18 22 0 1 2 19 21 6.7 8.3 2.5 12 EP : Fixed receptacle, back panel mounting 3* Size 24 28 8 9.5 3.2 3.8 16 20 *Lock washer not available *Lock washer not available FD : Straight plug ED : Protruding receptacle JBX Series ER : Fixed receptacle, front panel mounting* 0 1 2 A 19 21 24 B 4.5 6 6.5 4.5 C 2.5 3.2 3.8 24 OD 12 16 20 SR : Cable clamp receptacle* Size 0 1 2 Size 0 1 2 3 A 19 21 24 A 38 43 50 59 4.5 6.3 B 8 10 10 12 1.2 1.5 1.8 C 1.2 1.5 1.8 2 10 14 18 OD 10 14 18 22 Size 00 0 1 2 3 A 31 39 45 52 62 B 3 B 23 29 34 40 47 C OC 7 10 12 15 18 OD *Lock washer not available FC : 90 elbow plug PC : Cable mounted receptacle Size 0 1 2 3 A 30.5 36.5 42.5 50.5 B 20.5 25.5 30.5 35.5 C 29.5 33.5 36.5 OD 10 12 15 EZ : Receptacle for PCB Size 0 1 10 19 4 12 21 4 7.62 sq. 1.1 7.62 sq. 1.1 Size 0 1 2 45 A 38 43 50 59 OA B C D 18 OB 10 13 16 19.5 OE *All dimensions in mm. 7 3 JBX Series Dimensions * Special custom shells FN : Straight plug, shell 0 with a lanyard FM : 90 elbow plug, shell 0 with a lanyard FF : Straight plug, with no latching, size 1 SA : fixed receptacle with cable clamping, front or back panel mounting 8 JBX Series Keying JBX Series * Keying angles JBX Series are mechanically keyed to ensure correct alignment of the inserts before the contacts mate. G : standard keying J : standard reverse gender keying ; plugs with socket contacts, receptacles with pin contacts. *G & J are standard keying, but all keying configurations can use standard or reverse gender. Key J G Keying angle 0 B A sizes 0 - 1 sizes 2 - 3 45 37.5 sizes 0 - 1 30 60 Plug Receptacle * Keyed shells availability Shell size Key ER 00 G G J A B G J A 1 G J A 2 3 G 0 EA ED EP EZ SR PC FD FC FM FN SA Available for JBX series, customs can be ordered contact Project Management. 9 JBX Series Contact layouts * Multi contact inserts Shell size 00 Male insulator Contact viewed from layout wiring side Contact types available S solder C crimp P* straight Q* 90 PCB tails PCB tails AWG Solder Crimp wire wire Max. Max. Max. current rating (A)* 0.5 30 - 2 1000 500/350 O Contact (Vrms)* Working voltage (Vdc / Vrms)* Testing voltage 04 S 02 S C P Q 0.9 24 20 10 1400 660/460 03 S C P Q 0.9 24 20 8 1300 600/420 04 S C P Q 0.7 26 22 7 1400 660/460 05 S C P Q 0.7 26 22 6.5 800 400/260 06 S P 0.5 28 - 2.5 680 320/220 07 S P 0.5 28 - 2.5 680 320/220 02 S C P 1.3 20 18 15 1600 760/530 03 S C P Q 1.3 20 18 12 1300 600/420 04 S C P Q 0.9 24 20 10 1900 900/630 05 S C P Q 0.9 24 20 9 1400 660/460 06 S C P Q 0.7 26 22 7 1400 660/460 07 S C P Q 0.7 26 22 7 1400 660/460 08 S C P Q 0.7 26 22 5 1200 600/420 10 S 0.5 28 - 2.5 600 300/200 0 1 Inserts with fixed contacts (non removable contacts). * For receptacles with female contacts only. 10 JBX Series Contact layouts Shell size Male insulator Contact viewed from layout wiring side Contact types available S solder C crimp P* straight Q* 90 PCB tails PCB tails O Contact AWG Solder Crimp wire wire Max. Max. Max. current rating (A)* (Vrms)* Working voltage (Vdc / Vrms)* Testing voltage 02 S C 2 16 12 30 2100 1000/700 03 S C 1.6 18 14 17 1700 830/560 04 S C P Q 1.3 20 18 15 2400 1000/800 05 S C P Q 1.3 20 18 14 1900 900/630 06 S C P Q 1.3 20 18 12 1900 900/630 07 S C P Q 1.3 20 18 11 1500 730/500 08 S C P Q 0.9 24 20 10 1700 830/560 10 S C P Q 0.9 24 20 8 1700 830/560 12 S C P Q 0.7 26 22 7 1700 830/560 16 S C P Q 0.7 26 22 6 1500 730/500 18 S C P 0.7 26 22 5.5 1400 660/460 19 S C P 0.7 26 22 5 1400 660/460 03 S C 2 16 12 25 3600 1600/1200 04 S C 2 16 12 25 2500 1100/830 2 3 Inserts with fixed contacts (non removable contacts). * For receptacles with female contacts. 11 JBX Series * Multi contact inserts JBX Series Contact layouts * Multi contact inserts Shell size Male insulator Contact viewed from layout wiring side side Contact types available S solder C crimp P* straight PCB tails Q* 90 PCB tails O Contact AWG Solder Crimp wire wire Max. Max. Max. current rating (A)* (Vrms)* Working voltage (Vdc / Vrms)* Testing voltage 07 S C 1.6 18 14 15 2200 1000/730 10 S C 1.3 20 18 12 1400 660/460 14 S C P 0.9 24 20 9 1700 830/560 18 S C P 0.9 24 20 7 1400 660/460 22 S C P 0.7 26 22 5.5 1200 560/400 30 S C P 26 26 3.5 800 400/260 3 0.7 Inserts with fixed contacts (non removable contacts). * For receptacles with female contacts. Note : Contacts are numbered counter clock wise in the plug and clock wise in the receptacle. * Voltage Test Procedure - The testing voltage corresponds to the maximum voltage the connector is able to withstand in normal climatic conditions. The value is about 75% of the electrical breakdown voltage. The testing voltage level can be reached several times in connectors life, but never applied for a continuous duration. - The working voltage corresponds to the maximum voltage the connector is able to withstand continuously during its life time, in real environmental conditions, even with high temperature. The value is around 1/3 of the testing voltage. * Maximum current rating - This indicated maximum current rating corresponds to the maximum current that can be continuously applied to the connector mated pair, in normal climatic conditions. Remark : If the current is applied on only one contact of the layout, then an increased current value can be achieved over a long duration. 12 JBX Series Options Part number Dimensions Shell size OA O Cable L min Max. JBX 00 MPN 00 1.5 15 1 3.5 JBX 0 MP* 0 2.2 20 1.5 5.5 JBX 1 MP* 1 2.6 25 2 7.5 JBX 2 MP* 2 4 30 3.5 9.7 JBX 3 MP* 3 5 35 4.9 12 * Color code / In size 00, available only in black Color code Material : Colors ELASTOLLAN (PUR) A blue B white G grey J yellow M brown N black R red V green O orange Working temperature : - 40C ; + 80C - 40F ; + 176F With each JBX connector, one protective boot can accept multiple cable diameters thus the end-user can use various cable diameters without the need of multiple part numbers. * Receptacle caps : an effective protection against dust Part number O JBX BR0 12 mm JBX BR1 14 mm JBX BR2 17 mm JBX BR3 20 mm 13 Parts that require a protective boot need to be ordered with an M suffix, see page 5. Protective boots are ordered separately. JBX Series * Protective boot JBX Series Technical characteristics * Material and treatment 169916 Standard Component Surface treatment (m) Material ISO ASTM Cr Ni Au Outer shell and collet nut Brass CuZn40Pb3 C38500/C3600 0.1 - 0.6 5-8 - Latching sleeve & metal collet Brass CuZn40Pb3 C38500/C3600 - 5-8 - Shielding ring Brass CuZn40Pb3 C38500/C3600 - 3-7 - Nut Brass CuZn40Pb3 C38500/C3600 5-8 - Half bushes Brass CuZn40Pb3 C38500/C3600 - 5-8 - Socket contact (1) Copper Nickel- CuNi1Pb1P CDA C 19150 - 3-5 0.5 Pin contact (1) Brass CuZn35Pb2 C35300/C3600 - 3-5 0.5 Clip Beryllium copper CuBe1,9 C17200 - - - (1) Gold thickness as per MIL-G-45204C type 1, class 00. Component Insert Plastic collet Material Color Working Temperature or PEEK + 15%GF black brown - 65C + 200C - 50C + 250C - 85F + 392F - 58F + 482F PA 6/6 + MoS2 black - 55C + 125C - 67F + 257F PPS + 40%GF * Mechanical and climatics Characteristics Values Standard Method Endurance > 1000 cycles (except for 0.7 mm crimp contacts for which endurance is limited to 500 cycles) MIL-STD 1344A 2016.1 Shock 50 g, duration 6 ms ; contact O 0.7 mm and 0.9 mm 100 g, duration 6 ms ; contact O 1.3 mm - 1.6 mm and 2 mm MIL-STD 1344A 2004.1 Vibrations 10 to 2000 Hz = 15 g, contact O 0.7 mm and 0.9 mm = 20 g, contact O 1.3 mm - 1.6 mm and 2 mm MIL-STD 1344A 2005.1 Protection index IP 40 CEI 529 with plastic collets } - 55C + 125C - 67F + 257F with optional metal collets } - 55C + 200C - 67F + 392F Operating temperature - - - - Gas H2S : 100 ppb 20 ppb SO2 : 500 ppb 100 ppb IEC 68-2-60 test Ke method 1 Radiation stability 108 Rad - - 14 JBX Series Wiring and assembly instructions Size 00 0 1 2 3 OA 7.1 9.1 12.1 15.1 18.1 B 6.4 8.3 10.6 13.6 16.6 * Removable contacts Crimp contacts Contact Usable cables Core section (mm2) OC OF 0.7 0.9 1.3 1.6 2.0 0.85 1.1 1.4 1.9 2.4 Solder contacts min 0.129 0.205 0.326 0.823 1.309 Contact Max. 0.326 0.518 0.823 2.081 3.309 AWG 22-24-26 20-22-24 18-20-22 14-16-18 12-14-16 Usable cables Core section (mm2) OC OF 0.7 0.9 1.3 1.6 2 1.0 0.8 1.1 1.5 1.9 min - Max. 0.3 0.21 0.60 0.93 1.34 AWG 22.0 24 20 18 16 Max. Contact Endurance current resistance (number rating (A) (m) of cycles) 7 10 15 17 30 5 3.5 3 2.5 2.5 500 Max. > 1000 > 1000 > 1000 > 1000 Max. Contact Endurance current resistance (number rating (A) (m) of cycles) 7.0 10 15 17 30 5.0 3.5 3 2.5 2.5 500 Max. > 1000 > 1000 > 1000 > 1000 The conductor bucket on the solder contacts is designed with an angle to form a cup into which the solder can flow easily. * Fixed contacts Solder contacts Contact OC OF Shell size 0.5 0.4 0.5 0.63 00 0-1 0-1-2-3 0.7 Usable cables Core section (mm2) Max. AWG 0.06 0.096 0.15 Contacts for PCB Contacts for PCB 30 28 26 Max. Contact Endurance current resistance (number rating (A) (m) of cycles) 5 10 > 1000 7 5 > 1000 Contact length dimensions "L" PCB tail length size 0 dimension "L" 5.5 mm 0.7 mm female PCB tail length size 0 dimension "L" 3.5 mm 0.7 mm female PCB tail length size 1 dimension "L" 4.0 mm 0.7 mm female PCB tail length size 2 dimension "L" 6.0 mm 0.7 mm female PCB tail length size 3 dimension "L" 6.0 mm 0.9 mm female PCB tail length size 0 dimension "L" 3.5 mm 0.9 mm female PCB tail length size 1 dimension "L" 4.0 mm 0.9 mm female PCB tail length size 2 dimension "L" 6.0 mm 4.3 mm female PCB tail length size 1 dimension "L" 4.0 mm, dimension "F" 0.7 mm 1.3 mm female PCB tail length size 2 dimension "L" 6.0 mm, dimension "F" 0.7 mm 1.3 mm female PCB tail length size 3 dimension "L" 6.0 mm, dimension "F" 0.7 mm 15 JBX Series * Panel cutout JBX Series Wiring and assembly instructions * Cable stripping for connectors with crimp contacts OI : diameter over insulation Shell size 0 O contacts 0.7 0.9 1.3 0.7 0.9 2 1.3 1.6 2.0 0.7 0.9 3 L 1.35 > 1.35 1.6 > 1.6 1.35 > 1.35 1.6 > 1.6 2.1 > 2.1 1.35 > 1.35 1.6 > 1.6 2.1 > 2.1 2.6 > 2.6 3.2 > 3.2 1.35 > 1.35 1.6 > 1.6 2.1 > 2.1 2.6 > 2.6 3.2 > 3.2 0.7 0.9 1 OI 1.3 1.6 2.0 15 15 16 16 16 19 19 19 21 21 25 25 25 27 27 Stripping for FD, SR, PC C 4 5.5 4 5.5 4 5.5 4 5.5 4 5.5 4 5.5 4 5.5 4 5.5 5.5 7 5.5 7 4 7 4 7 4 7 5.5 8.5 5.5 8.5 T L 7 19 7 19 8 22 8 22 8 22 9 28 9 28 9 28 9 28 9 28 10 35 10 35 10 35 10 35 10 35 Stripping for FC C 4 5.5 4 5.5 4 5.5 4 5.5 4 5.5 4 5.5 4 5.5 4 5.5 5.5 7 5.5 7 4 7 4 7 4 7 5.5 8.5 5.5 8.5 T 7 7 8 8 8 9 9 9 9 9 10 10 10 10 10 * Cable stripping for connectors with solder contacts Shell size O Contacts 00 0.5 0.5 0.7 0.9 0.5 0.7 0.9 1.3 0.7 0.9 1.3 1.6 2 0.7 0.9 1.3 1.6 2 0 1 2 3 L 9 11 12 12 12 13 13 13 16 16 16 18 18 20 20 20 22 22 Stripping for FD, SR, PC S 2 2 3 3 2 3 3 3.5 3 3 3.5 4 4 3 3 3.5 4 4 16 T 4 7 7 7 8 8 8 8 9 9 9 9 9 10 10 10 10 10 L / 16 16 16 19 19 19 19 25 25 25 25 25 30 30 30 30 30 Stripping for FC S / 2 3 3 2 3 3 3.5 3 3 3.5 4 4 3 3 3.5 4 4 T / 7 7 7 8 8 8 8 9 9 9 9 9 10 10 10 10 10 JBX Series JBX Series Wiring and assembly instructions : STRAIGHT PLUG * Connector preparation 1 - Select the proper collet. (see page 19) 2 - Slide the protective boot the backnut and the collet over the cable. Strip end of cable (see pg. 17). 3 - If a shielded cable is used fold the braid back over the collet. * Contacts wiring : crimp contacts 1 - Select the proper crimping tool and locator. (see page 48) 2 - Adjust the crimping tool based on wire size "AWG". (See wire size and crimp tool settings on the back of the locator) 3 - Crimp the contacts then insert the contact into the insulator until the clip is fully seated and cannot be removed. * Contacts wiring : solder contacts Fixed solder contacts 0.5 mm and 0.7 mm Removable solder contacts from 0.9 mm to 2 mm 1 - Insert wire into solder cup and solder. 1 - Insert wire into solder cup and solder. 2 - Insert contact into the insulator until the clip is fully seated and cannot be removed. * Connector assembly 1 - Position 2 half bushings on either side of the insulator. 2 - Confirm that the key on the insulator appears through the window in the one half bushing. Window 3 - Align the key slot on the collet with the keys on the half bushings. 4 - Insure the cable shield is still folded back and under the collet. 5 - Insert the insulator subassembly connector housing . Flats B & into the 6 - Make sure the window on the half bushing is aligned with the key way on the connector housing . 7 - Apply thread lock to back nut . 8 - Attach the back nut to the connector housing 9 - Use the correct size wrench, see page 19. 10 - Place the wrenches on the flats A and B. Tighten the back nut per the torque spec on page 19. 11 - Install the protective boot if applicable. 17 Flats A JBX Series Wiring and assembly instructions : 90 ELBOW PLUG * Connector preparation 1 - Select the proper collet (see page 19). 2 - Slide the protective boot , the backnut , the collet and the elbow outlet over the cable. Strip end of cable (see pg. 17). 3 - If a shielded cable is used, fold the braid back over the collet . 4 - Align the keys in the elbow outlet with the key slot in the collet. 5 - Apply thread lock to the backnut . Braid 6 - Install the back nut and tighten until it bottoms. * Contacts wiring : crimp contacts 1 - Select the proper crimping tool and locator. (see page 48) 2 - Adjust the crimping tool based on wire size "AWG". (See wire size and crimp tool settings on the back of the locator) 3 - Crimp the contacts then insert the contact into the insulator until the clip is fully seated and cannot be removed. * Contacts wiring : solder contacts Fixed solder contacts 0.5 mm and 0.7 mm Removable solder contacts from 0.9 mm to 2 mm 1 - Insert wire into solder cup and solder. 1 - Insert wire into solder cup and solder. 2 - Insert contact into the insulator until the clip is fully seated and cannot be removed. * Connector assembly : 90 degree plug 1 - Position the ring over the insulator. 2 - Align the key on the insulator with the key way on the spacer and insert the insulator into the spacer. Milled flats A 3 - Insert the insulator sub-assembly into the connector housing insuring the flats on the elbow outlet are facing the retaining nut . 4 - Apply thread lock to retaining nut . 5 - Tighten the retaining nut to the recommended torque on page 19. 18 JBX Series Wiring and assembly instructions 4 or 6 collets per shell size are supplied to allow the use of a wide range of cable diameters for each connector. The cable diameters given on this chart are the minimum and maximum diameters of cable jacket. Cable diameter Collet number Shell size 00 Shell size 0 Shell size 1 Shell size 2 Shell size 3 1 1.1 - 1.9 1.5 - 2.5 2.0 - 2.5 3.5 - 4.7 4.9 - 6 2 2 - 2.8 2.6 - 3.5 2.6 - 3.5 4.8 - 5.7 6.1 - 7.2 4 3 2.9 - 3.5 3.6 - 4.5 3.6 - 4.5 5.8 - 6.7 7.3 - 8.4 3 4 - 4.6 - 5.5 4.6 - 5.5 6.8 - 7.7 8.5 - 9.6 5 - - 5.6 - 6.6 7.8 - 8.7 9.7 - 10.8 6 - - 6.7 - 7.5 8.8 - 9.7 10.9 - 12.0 2 1 6 5 *Cable jacket must be inserted at least halfway through the collet. Metal collets are available as an option in size 0, 1, 2, & 3. * Coupling torques Tools (jaw dimensions) Size Metal collet available for all sizes 7 x 0.5 9 x 0.6 12 x 1 15 x 1 18 x 1 Advised torques* in Nm 00 0 1 2 3 00 0 1 2 3 7 11 14 17 21 0.5 0.7 1.3 1.7 2 6 8 10 13 15 0.7 0.8 1 1.5 2 6 9 11 14 16 0.7 0.8 1 1.5 2 - 10 12 15 17 - - 10 13 17 20 0.5 0.7 1.3 1.7 2 - 9 13 15 - - - - - - 0.4 to 0.5 0.5 to 0.7 Discreet application based on cable diameter. Torque values are the maximum allowable for each connector size. Torque values will vary due to the type and size of the cable used *Apply thread lock to back nut prior to assembly. Note : All the tooling numbers refer to the drawings pages 7 and 8. * Shielding Shell size Electrical continuity (m) 00 4.5 0 4 1 3 2 2.5 3 2.5 Tested according to MIL-STD 1344 A, method 3007 mV G A 19 JBX Series * Collet selection according to cable diameters JAX Series Key features * Hermaphroditic insert : prevents mismatings. * Multipin connectors : contact layouts from 1 to 14. * Wire gauges range from 26 AWG to 16 AWG. * High contact density in a small space. * Coaxial contacts : 50 and 75 impedance. User advantages Large range of blind mate coaxial connectors Part number system JAX Basic series Shell type F - RA - PC Shell size 00 - 0 - 1 - 2 - 3 Contact layout - multi contacts : see designation table page 22 - coaxial : see designation table page 22 Suffix for cable outside diameter, see table page 23 B : obligatory suffix 20 F 2 M3 D080 B JAX Series Shell types RA : fixed receptacle, front panel mounting, nut fixing F : straight plug PC : free receptacle, with cable clamping Straight plug - ref. F Size 00 0 1 2 3 A 25 34 43 51 61 OB 6.5 9 12 15 18 OC 3.2 4.2 6.2 8.2 11.2 Oc 2.2 2.2 2.2 4.2 4.2 D 17 24 32 39 46 Size 00 0 1 2 3 A OB OC D E OF G K OM L 11 8 M7 x 0.5 1 6.5 7.1 3.5 9 6 6.4 13.3 10 M9 x 0.6 1.2 7 9.2 3.5 11 8 8.3 15 14 M12 x 1 1.5 8 12.2 3 14 10 10.6 16.5 18 M15 x 1 1.8 8 15.2 5 17 13 13.6 20.5 22 M18 x 1 2 11 18.2 4.5 21 16 16.6 Size 00 0 1 2 3 A 24 33 40 49 59 B 6.5 9 12 15 18 C 3.2 4.2 6.2 8.2 11.2 c 2.2 2.2 2.2 4.2 4.2 Round flange - ref. RA In line plug - ref. PC 21 JAX Series Dimensions JAX Series Contact layouts * Multi contacts inserts Shell size Plug insulator viewed from wiring side 00 Contact layout Designation 1 UM (plug) UF 1 x O 1.3 pin contact 3 x O 0.7 4 x O 0.7 pin contact 1 2 x O 1.3 3 x O 0.9 4 x O 0.9 6 x O 0.7 pin contact 2 2 x O 1.6 3 x O 1.6 4 x O 1.3 6 x O 1.3 pin contact 8 x O 0.9 10 x O 0.9 pin contact 3 4xO2 Max current rating (A) Testing voltage (Vrms) Working voltage (Vdc / Vrms) 1.3 8 900 400 / 300 (receptacle) 0 2 x O 0.9 O Contact 10 x O 1.3 14 x O 0.9 2 3 4 M2 M3 M4 0.9 0.7 0.7 10 7 7 1500 1050 1050 700 / 500 500 / 350 500 / 350 2 3 4 6 M2 M3 M4 M6 1.3 0.9 0.9 0.7 15 10 10 7 1200 1200 1200 1200 600 / 400 600 / 400 600 / 400 600 / 400 2 M2 1.6 20 1800 600 / 400 3 M3 1.6 15 1500 600 / 400 4 M4 1.3 15 1500 600 / 400 6 M6 1.3 12 1500 600 / 400 8 M8 0.9 9 750 800 / 600 10 M10 0.9 7 750 700 / 500 4 10 14 M4 M10 M14 2 1.3 0.9 18 9 7 1500 1050 1050 700 / 500 500 / 350 500 / 350 Testing voltage (Vrms) Working voltage (Vdc / Vrms) Designation to use in the part-number system, page 20 * Coaxial inserts Shell size 00 0 1 2 3 Insulator Contact impedance () Designation O Contact Max current rating (A) 50 C50 0.7 5 1800 800 / 600 50 C50 1.3 10 2300 1100 / 780 50S C50S 0.9 6 2300 1100 / 780 50 C50 1.6 12 2300 1100 / 780 75 C75 1.3 10 2900 1400 / 980 50 C50 2 15 2900 1400 / 980 75 C75 1.6 12 3900 1800 / 1300 50 C50 3 26 5700 2800 / 1900 75 C75 2 15 6300 3000 / 2100 Designation to use in the part-number system, page 20. 22 JAX Series Shell size 00 0 1 2 3 Accomodation of cable diameter Obligatory suffix From 1.5 mm to 2.2 mm D020 From 2 mm to 3.2 mm D030 From 2 mm to 3.2 mm D030 From 3 mm to 4.2 mm D040 From 2 mm to 3.2 mm D030 From 3 mm to 4.2 mm D040 From 4 mm to 5.2 mm D050 From 5 mm to 6.2 mm D060 From 4 mm to 5.2 mm D050 From 5 mm to 6.2 mm D060 From 6 mm to 7.2 mm D070 From 7 mm to 8.2 mm D080 From 4 mm to 5.2 mm D050 From 5 mm to 6.2 mm D060 From 6 mm to 7.2 mm D070 From 7 mm to 8.2 mm D080 From 8 mm to 9.2 mm D090 From 9 mm to 10.2 mm D100 From 10 mm to 11.2 mm D110 JAX Series Suffix for cable outside diameter Designation to use in the part number system, page 20 Options * Caps Part number A B C D JAX RA 120 12 11 20 70 JAX RA 220 15 11 21 70 JAX RA 320 18 14 26 70 Material: Nickel-chromium brass. Neoprene seal. 23 JAX Series Technical characteristics * Material and treatment Standard Component Surface treatment (m) Material ISO ASTM Cr Ni Au Outer shell and collet nut Brass CuZn40Pb3 C38500 0.1 - 0.6 5-8 - Latching sleeve Brass CuZn40Pb3 C38500 - 5-8 - Shielding ring Brass CuZn40Pb3 C38500 - 3-7 - Nut Brass CuZn40Pb3 C38500 5-8 - Half bushes Brass CuZn40Pb3 C38500 - 5-8 - Socket contact (1) Cupro-nickel CuNi1Pb1P - - 3-5 0.5 Pin contact (1) Brass CuZn35Pb2 C35300 - 3-5 0.5 Material Color (1) Gold thickness as per MIL-G-45204C type 1, class 00. Component TEFZEL (coaxial connector) Temperature withstanding White - 70C ; + 150C - 94F ; + 302F Grey - 40C ; + 125C - 40F ; + 257F Insert Nylatron GS (multipin connector) * Mechanical and climatics Characteristics Values Standard Endurance 1000 cycles Protection index IP 40 Operating temperature - 40C ; + 125C / - 40F ; + 257F 24 CEI 529 JAX Camac Series These 2 pages describe the JAX Camac series, size 00. These connectors are often used on jumpers for delay lines in Nuclear Physics due to their size and simple handling in congested areas. For Nuclear Physics, our connectors meet the standard NIM-CAMAC*. Moreover, JAX coaxial connectors are suitable for many other industrial and scientific applications such as medical, microwave communications, pocket transmitters, input/output on electronic modules. NIM-CAMAC* configuration (4 GHz - 50 ) Dimensions and part-numbers P/N : JAX F 00 C50 RG 174 US Straight plug for RG174U cable P/N : JAX 00 MDPN Protective boot P/N : JAX RA 00 C50S Fixed front flange receptacle, solder contacts Cable O = min = 1 max = 3.8 Weight : 0.2 g Temperature = - 40C ; + 80C P/N : JAX RA 0018 RF screening cap O8 L Weight : 3.5 g Weight : 2.5 g O2.1 min 9 on flats Weight : 1.5 g Technical data Specific characteristics Endurance Values 5000 cycles Operating temperature - 70C ; + 200C - 94F ; + 392F Plating on metal shell Ni = 3 - 7 m Insert PTFE 25 JAX Series * NIM-CAMAC : Nuclear Instrumentation Module / Computer Automated Measurement and Control JAX Camac Series Delay lines * Cable Nr 96-CEI-50-2-1 (RG 174U) fitted with NIM-CAMAC connectors at both ends L : Length which defines delay in ns of cable jumpers P/N Delay (ns) Tolerance (%) L* JAX L 00 C50 C11 R005 0.5 5 100 JAX L 00 C50 C11 R010 1 5 200 JAX L 00 C50 C11 R020 2 2.5 400 JAX L 00 C50 C11 R030 3 1.7 600 JAX L 00 C50 C11 R040 4 1.3 800 JAX L 00 C50 C11 R050 5 1 1000 JAX L 00 C50 C11 R060 6 1 1200 JAX L 00 C50 C11 R080 8 1 1600 JAX L 00 C50 C11 R100 10 1 2000 JAX L 00 C50 C11 R160 16 0.6 3200 * Average length, for information only * Crimping tool P/N : JX2W1010A9 26 JAX Series Wiring and assembly instructions * Panel cutout Size 00 0 1 2 3 A 7.1 9.1 12.1 15.1 18.1 B 6.4 8.3 10.6 13.6 16.6 O Contact Usable cables (AWG) OF 0.7 26 0.6 0.9 24 0.8 1.3 20 1.1 1.6 18 1.5 2.0 16 1.9 JAX Series * Contacts * Cable stripping for connectors with multi contacts (solder contacts) Size A B C* 0 9 4 7 1 12 4 8 2 17 4 9 3 19 4 10 * If shielded cable * Cable stripping for connectors with coaxial contacts / single contacts Size A B C 00 15 4 15 0 15.5 4.5 6 1 18.5 6.5 6 2 25 7 7 3 23 7.5 10 27 JAX Series Wiring and assembly instructions : MULTIPIN PLUGS SIZES 0, 1, 2, 3 * Cable stripping : see page 27 * Connector preparation and contacts wiring 1 - Slide the backnut and the collet onto the cable. 2 - Terminate the bucket contacts using solder method. * Connector assembly 3 - For shielded cable : pull back the collet up to external sheath extremity. 4 - Comb out the screen and fold back over the collet end. 5 - Position two half bushes on the insert, taking care of a proper positioning of the key. 6 - Slide in the insert assembly into the plug (or the free receptacle) shell. Note : the collet key may be properly set into shells key ways. 7 - Install the backnut and screw it. 28 JAX Series Wiring and assembly instructions : COAXIAL PLUGS * Cable stripping : see page 27 * Connector assembly 1 - Slide the backnut and the collet onto the cable. 2 - Position the intermediate cone in abutment on external sheath extremity 3 - Brush back the screen around the cone 4 - Pull back the collet onto the cone Note : - Take care to align cone key inside the sub-assembly rear key way. - The stripped core end may be visible inside pin contact front window. Remark : For size 00, no cone existing : sub-assembly directly onto collet. 6 - Solder inner core thru the pin window 7 - Set in place the front insulator, taking care of the key/keyway positioning between the two half insert sub-assembly 8 - Slide in the insert assembly into the plug (or free receptacle shells) 9 - Install the nut and screw it Wiring and assembly instructions : SINGLE PIN PLUGS * Cable stripping : see page 27 * Connector assembly Monolythic insert is directly soldered onto the inner core. JAX Series 5 - Position the rear insulator sub-assembly on the cone JAX Camac Series Wiring and assembly instructions : Crimp contact (NIM-CAMAC configuration) * Wiring preparation 1 - Slide the protective boot and the crimping ferrule onto the cable * Coaxial cable stripping 1 - Strip the coaxial cable according to the lengths given on the drawing * Contact crimping Crimping 1 - Take the crimping tool P/N : JX2 W 1010 A9 2 - Crimp the contact * Connector assembly 1 - Position the crimp contact then engage the insert cavity until it bottoms 2 - Fold the screen over the connector outlet 3 - Position the ferrule on the screen then crimp it Crimping 4 - Slide the protective boot and then position on the connector outershell 30 JKX Series Key features * Sealed IP 68 (mated connectors) * Mechanically keyed : ensures correct polarization and alignment. * Contact arrangements : from 2 to 10 contacts. * Wire gauge range from 28 AWG to 14 AWG. * High contact density in a small space. * Contact termination in either crimp, solder or PCB contacts. Removable contacts User advantages Crimp versions allow easier wiring and maintenance. 6-collet cluster Temporary immersion IP 68 Allows a wide range of cable diameter applications for a single connector. Reduces inventory variations. Part number system FD 1 G 05 M C SDS Shell configuration FD - ER - EP - PC Size 0-1 Keying G Contact layouts 02 ---------- 10 (see page 33) Contact type M : pin Contact termination C : crimp ; S : solder ; P* : straight PCB tails ; Q* : 90 PCB tails ; W : 0.7 mm clipped solder Material & surface plating S : Outer shell in brass alloy with glossy chrome over nickel N : Outer shell in brass alloy with black plating (consult us) D : Obligatory suffix F : socket (in relation with keying) S : Insulator in PPS P : Insulator in Peek (for O 0.5 mm contacts only) Obligatory suffix for layouts including contacts of O 0.5 mm Options M JKX Series JKX Basic series M : Connector with backnut for protective boot (protective boot to order separately page 34) G : Connector adapted to accomodate larger cables (O 4.5 to 6 in size 0 and O 6 to 8 in size 1) R : Red dot (possible for FD, PC, ER only) * For receptacles with female contacts only. 31 JKX Series Shell type * Available JKX shells * Dimensions ER : Fixed receptacle, front panel mounting FD : Straight plug with cable clamping Size A B C OD Size A OB OM 0 19.5 4.5 4 18 0 47 12 1.5 to 4.5 1 24.5 8.5 4.5 20 1 57 15 2 to 6 EP : Fixed receptacle, back panel mounting Size A B C PC : Cable mounted receptacle OD Size A OB OC _ _ 2 to 6 0 19.5 4.5 3.2 18 0 _ 1 24.5 6 4 20 1 60 16 Size A OB OM 0 51 12 4.6 to 6 1 60 15 6 to 8 * Option G : to accomodate bigger cables 32 JKX Series Keying G keying is available in standard version (0 keying angle, plugs with pin contacts, receptacles with female contacts) for the 4 shell types. Reverse gender available in all layouts. Shell size Key ER EP PC FD 0 G _ 1 G Concerning the availability of other alternatives, please consult our commercial office. Contacts * Multi contacts inserts Shell size Male insulator Contact viewed from layout wiring side Available Contact types S solder C crimp P* straight Q* 90 PCB tails PCB tails O Contact AWG Solder Crimp wire wire Max. Max. Max. current rating (A) Testing voltage (Vrms) Working voltage (Vdc / Vrms) 02 S C P Q 0.9 24 20 10 1400 660/460 03 S C P Q 0.9 24 20 8 1300 600/420 04 S C P Q 0.7 26 22 7 1400 660/460 05 S C P Q 0.7 26 22 6.5 800 400/260 06 S P 0.5 28 - 2.5 680 320/220 07 S P 0.5 28 - 2.5 680 320/220 02 S C P 1.3 20 18 15 1600 760/530 03 S C P Q 1.3 20 18 12 1300 600/420 04 S C P Q 0.9 24 20 10 1900 900/630 05 S C P Q 0.9 24 20 9 1400 660/460 06 S C P Q 0.7 26 22 7 1400 660/460 07 S C P Q 0.7 26 22 7 1400 660/460 08 S C P Q 0.7 26 22 5 1200 600/420 10 S 0.5 28 - 2.5 600 300/200 1 P Inserts with fixed contacts (non removable contacts) * For receptacles with female contacts only JKX Series 0 JKX Series Options * Protective boot Protective boot can accept multiple cable diameters Part number Shell size Dimensions Shell size Option G OA O Cable L min Max. JBX 0 MP* 0 - 2.2 20 1.5 5.5 JBX 1 MP* 1 0 2.6 25 2 7.5 JBX 2 MP* - 1 4 30 3.5 9.7 * Color code Color code Colors Material : ELASTOLLAN (PUR) A blue B white Working temperature : G grey - 40C ; + 80C J yellow - 40F ; + 176F M brown N black R red V green O orange With each JKX connector, one protective boot can accept diverse cable diameters thus the end-user can manage various cable diameters without bothering with multiple part numbers. * Caps : an efficient protection until 2 bars Part number O JKX BR0 15 JKX BR1 17 34 JKX Series Technical characteristics * Material and treatment Standard Component Surface treatment (m) Material ISO ASTM Cr Ni Au Outer shell and collet nut Brass CuZn40Pb3 C38500/C360 0.1 - 0.6 5-8 - Latching sleeve & metal collet Brass CuZn40Pb3 C38500/C360 - 5-8 - Shielding ring Brass CuZn40Pb3 C38500/C360 - 3-7 - Nut Brass CuZn40Pb3 C38500/C360 5-8 - Tapered washer and half bushes Brass CuZn40Pb3 C38500/C360 - 5-8 - Socket contact (1) Copper-nickel CuNi1Pb1P CDA C 19150 - 3-5 0.5 Pin contact (1) Brass CuZn35Pb2 C35300/C360 - 3-5 0.5 Clip Beryllium copper CuBe1,9 C17200/C360 - - - (1) Gold thickness as per MIL-G-45204C type 1, class 00. Material Color Temperature withstanding or PEEK + 15%GF black brown - 65C + 200C - 50C + 250C - 85F + 392F - 58F + 482F Plastic collet PA 6/6 + MoS2 black - 55C + 125C - 67F + 257F Cable seal Silicon rubber red - 50C + 250C - 58F + 482F Insert PPS + 40%GF * Mechanical and climatics Characteristics Values Standard Method Endurance > 1000 cycles (except for 0.7 mm crimp contacts for which endurance is limited to 500 cycles) MIL-STD 1344A 2016.1 Shock 50 g, duration 6 ms ; contact O 0.7 mm and 0.9 mm 100 g, duration 6 ms ; contact O 1.3 mm - 1.6 mm and 2 mm MIL-STD 1344A 2004.1 Vibrations 10 to 2000 Hz = 15 g, contact O 0.7 mm and 0.9 mm = 20 g, contact O 1.3 mm - 1.6 mm and 2 mm MIL-STD 1344A 2005.1 Protection index IP 68 (watertight - 48 hours under 1 m of water) CEI 529 with plastic collets } - 55C + 125C - 67F + 257F with optional metal collets } - 55C + 200C - 67F + 392F Operating temperature 35 - - - - JKX Series Component JKX Series Wiring and assembly instructions * Panel cutout +0.2 -0 A B o+0.3 +0.1 Size 0 1 OA 14.1 16.1 B 12.6 14.6 * Removable contacts Crimp contacts Contact Usable cables Core section (mm2) OC OF 0.7 AWG Max. Contact Endurance current resistance (number rating (A) (m) of cycles) min Max. 0.85 0.129 0.326 22 - 24 - 26 7 5 500 Max. 0.9 1.1 0.205 0.518 20 - 22 - 24 10 3.5 > 1000 1.3 1.4 0.326 0.823 18 - 20 - 22 15 3 > 1000 Solder contacts Contact Usable cables Core section (mm2) OC OF 0.7 0.9 1.3 1.0 0.8 1.1 min - Max. 0.3 0.21 0.60 AWG 22 24 20 Max. Contact Endurance current resistance (number rating (A) (m) of cycles) 7 10 15 5 3.5 3 500 Max. > 1000 > 1000 The conductor bucket on the solder contacts is designed with an angle to form a cup into which the solder can flow easily. * Fixed contacts Solder contacts Contact Contacts for PCB Usable cables Core section (mm2) Max. AWG Max. Contact Endurance current resistance (number rating (A) (m) of cycles) OC OF Shell size 0.5 0.5 0-1 0.096 28 5 10 > 1000 0.7 0.63 0-1 0.15 26 7 5 > 1000 Contacts for PCB Contact length dimensions "L" PCB tail length size 0 dimension "L" 5.5 mm 0.7 mm female PCB tail length size 0 dimension "L" 3.5 mm 0.7 mm female PCB tail length size 1 dimension "L" 4.0 mm 0.9 mm female PCB tail length size 0 dimension "L" 3.5 mm 0.9 mm female PCB tail length size 1 dimension "L" 4.0 mm 1.3 mm female PCB tail length size 1 dimension "L" 4.0 mm, dimension "F" 0.7 mm 36 JKX Series Wiring and assembly instructions * Cable stripping for connectors with crimp contacts Shell size O Contacts 1.6 15 > 1.6 OI : diameter over insulation 1.35 0.7 1 15 > 1.35 0.9 17 > 1.35 1.6 0.9 17 > 1.6 2.1 1.3 Stripping for FD / PC C L 1.35 0.7 0 OI 17 > 2.1 T 4 7 5.5 4 7 5.5 4 8 5.5 4 8 5.5 4 8 5.5 * Cable stripping for connectors with solder contacts Shell size O Contacts 0.5 0.7 0.9 0.5 0.7 0.9 1.3 0 1 L 11 12 12 13 14 14 14 Stripping for FD / PC S 2 3 3 2 3 3 3.5 T 7 7 7 8 8 8 8 * Watertightness design (mated connectors) Fixed receptacle JKX Series Straight plug : O'ring for sealing between receptacle and plug shell : O'ring for sealing between receptacle and panel : O'ring for sealing between plug body and backshell : seals to accomodate variety of cable diameters 37 JKX Series Wiring and assembly instructions : STRAIGHT PLUG * Cable stripping : see page 37 * Connector preparation 1 - Select the proper collet seal (see page 39). and the cable 2 - Slide protective boot , the backnut , the collet , the cable seal , the outershell and the taper seat onto the cable. Strip end of cable (see pg. 16) * Contacts wiring : crimp contacts 1 - Select the proper crimping tool (see page 48) 2 - Adjust the crimping tool based on the wire size "AWG". (See wire size and crimp tool settings on the back of this locator.) 3 - Crimp the contacts then insert the contact into the insulator until the clip is fully seated and cannot be removed. * Contacts wiring : solder contacts Fixed solder contacts 0.5 mm and 0.7 mm Removable solder contacts from 0.9 mm to 1.3 mm 1 - Insert wire into solder cup and solder 1 - Insert wire into solder cup and solder 2 - Insert the contact into the insulator until the clip is fully seated and cannot be removed. * Connector assembly 1 - In case of shielded cable, comb out the shield and fold back over the tapper seat . 2 - Position 2 half bushes , making sure that the insert key appears through the windows of one bush. 3 - Position the taper seat on the half bushes . 4 - Position all the sub-assembly in connector housing , making sure to keep the subassembly well aligned. 5 - Screw the outershell following the torque values on page 39. Install the cable seal and the collet into the outershell then screw the backnut till bottoming. Use 2 wrenches well positionned on the flats A and B. Place a wrench to grip flats B, use the other wrench to tighten the backnut at the flats A following the torque values on page 39. 6 - Install the protective boot if applicable. 38 JKX Series Wiring and assembly instructions * Collets selection according to cable diameters 3 or 5 collets per shell size allow a wide range of cable diameters for a single connector. Cable out diameters are for information only, since values will change with each cable construction. Collet number 2 1 2 3 4 5 1 4 6 3 5 Shell size 0 1.5 - 2.5 2.6 - 3.5 3.6 - 4.5 - Cable diameter Size 0, option G Shell size 1 2 - 2.5 2.6 - 3.5 3.6 - 4.5 4.6 - 5.5 4.6 - 5.5 5.6 - 6 5.6 - 6 Size 1, option G 6.1 - 6.7 6.8 - 7.7 7.8 - 8 Collet number 4 in shell size 0 and collet number 6 in shell size 1 are not used. * Cable seal selections according to cable size Cable gland OA 2 3.5 2.5 4 5.5 7 OA Discreet application based on cable diameter Shell size 0 1.5 - 2.9 3 - 4.5 Cable diameter Size 0, option G Shell size 1 Size 1, option G 2 - 3.4 3.5 - 4.9 5-6 4.6 - 4.9 5-6 6.1 - 6.4 6.5 - 8 * Shielding Tested according to MIL-STD 1344 A, method 3007 Tools 1 3 0 (option G) 1 1 Size (option G) 16 x 1 14 x 1 (jaw dimensions) 0 4 Tool dimensions Advised torque* in Nm mm 0 A * Coupling torques Size Electrical continuity (m) JKX Series mV G Shell size 0 1.6 / 1.8 / 1.5 2 2 2.5 8 0.8 0.8 1 1 10 0 (option G) 1 17 19 *Apply thread lock to back nut prior to assembly. 39 13 10 11 Tool numbers can be found on page 32 Torque values are the maximum allowable for each connector size. Torque values will vary due to the type and size of the cable used 1 (option G) 12 14 JBX Series sealed version size 2 Key features * Sealed IP 67 (mated connectors)(FE, EC, SE, & PC) * Watertight receptacles IP68 (HC & HH) * Mechanically keyed : ensure correct polarisation and alignment. * Contact arrangements : from 2 to 19 contacts. * Wire gauge range from 26 AWG to 12 AWG. * High contact density in a small space. * Contact termination in either crimp, solder or PCB contacts. User advantages 6-collet cluster Wet environment IP67 Removable contacts (EC, FE, SE & PE) Allows a wide range of cable diameter applications for a single connector. Reduces inventory variations. Crimp versions allow easier wiring and maintenance. Part number system JBX Basic series FE 2 G 12 M Shell type FE-HH-HC-EC-PE-SE Shell size 2 Keying G Contact layouts 02 ---------- 19 Contact type M : pin Contact termination C : crimp ; S : solder ; P* : straight PCB tails ; Q* : 90 PCB tails Material & surface plating S : Outer shell in brass alloy with chrome over nickel N : Outer shell in brass alloy with black plating (consult us) F : socket (in relation with keying) D : Obligatory suffix S : Obligatory suffix Option R : FE, PE, HH, & HC N/A for EC & SE * For receptacles with female contacts only. 40 C S D S R JBX Series sealed version size 2 Shell type * Available sealed JBX, Size 2 EC : Double nut receptacle HC : Fixed receptacle, back panel mounting FE : Straight plug with cable clamping PE : Cable mounted receptacle SE : Fixed receptacle with cable clamping * Dimensions EC : Double nut receptacle. Sealed mated IP67 not sealed unmated. SE : Cable clamp receptacle, sealed mated IP67, supplied with protective boot. PE : Cable mounted supplied with protective boot sealed mated IP67. HC : Fixed receptacle, back panel mount. Sealed unmated IP68, not available in crimp, 4-position minimum. JBX Series FE : Straight plug supplied with protective boot, sealed mated IP67. 41 JBX Series sealed version size 2 Keying Only G keying is available in standard version (0 keying angle, plugs with pin contacts, receptacles with female contacts) for the different types of shells. Contact layouts * Multi contact inserts Shell size Male insulator Contact viewed from layout wiring side Available Contact types S solder C crimp P* straight Q* 90 PCB tails PCB tails O Contact AWG Solder Crimp wire wire Max. Max. Max. current rating (A)* Testing voltage (Vrms)* Working voltage (Vdc / Vrms)* 02 S C 2 16 12 30 2100 1000/700 03 S C 1.6 18 14 17 1700 830/560 04 S C P Q 1.3 20 18 15 2400 1000/800 05 S C P Q 1.3 20 18 14 1900 900/630 06 S C P Q 1.3 20 18 12 1900 900/630 07 S C P Q 1.3 20 18 11 1500 730/500 08 S C P Q 0.9 24 20 10 1700 830/560 10 S C P Q 0.9 24 20 8 1700 830/560 12 S C P Q 0.7 26 22 7 1700 830/560 16 S C P Q 0.7 26 22 6 1500 730/500 18 S C P 0.7 26 22 5.5 1400 660/460 19 S C P 0.7 26 22 5 1400 660/460 2 Inserts with fixed contacts (non removable contacts). * For EC and HC receptacles with female contacts only. HH & HC fixed contacts only. 42 JBX Series sealed version size 2 Technical characteristics The technical characteristics are the same as for the standard JBX series except the following ones: * Material - Specific additionnal elements Component Material Color Working temperature Seals Nitrile O'ring seal = black - 30C ; + 250C - 58F ; + 482F Protective boot Elastollan (PUR) Black - 40C ; + 80C - 40F ; + 176F * Mechanical and climatics - Specific additional elements Characteristics Values Protection index Operating temperature IP 67 (Splashproof - 1/2 hour under 1 m of water) - 40C ; + 80C - 40F ; + 176F Options * Cap: Part-number = JBX BR2 022 : an efficient protection against water Wiring and assembly instructions * Panel cutout The panel cutout is the same as for the JBX size 2 shells except for the HC. * Operation to add during the plug assembly: Deposit of watertight thread glue between the backnut ( on the drawing p17) and the connection shell ( on the drawing p17). Advised glue = Loctite 542. Sealed JBX * Sealed Panel cutout 43 Push-Pull connectors Accessories JAX - JBX * Insulating washer 2 washers Nut Part number Shell size OA B L M N T E JBX 00 RIN 00 10 8.8 1.8 1 0.8 8 4.4 JBX 0 RI* 0 12 10.8 1.8 1 0.8 9.9 6.4 JBX 1 RI* 1 16 13.8 1.8 1 0.8 12.2 8.4 JBX 2 RI* 2 21 17.8 2.2 1.2 0.8 16.2 8.2 JBX 3 RI* 3 25 21.8 2.2 1.2 0.8 20.2 10.1 * Washer colors as protective boots. In size 00, available only in black. Material : PA 6/6 Working temperature : - 40C ; + 125C - 40F ; + 257F Receptacle Using 2 washers for receptacle / panel insulating Be careful : usable for the JAX and JBX series but not for sealed connectors (JKX and sealed JBX size 2). * Grounding washer Dimensions Part number Shell size OA OB L N JAX RA 00 251 00 10 7.2 0.3 21.5 JAX RA 0 251 0 13 9.1 0.3 24 JAX RA 1 251 1 16 12.2 0.3 24 JAX RA 2 251 2 21 15.1 0.8 35 JAX RA 3 251 3 25 18.1 0.8 37 OA L N OB Material : - Brass - Nickel plated (3 m) Be careful : usable for the JAX and JBX series but not for sealed connectors (JKX and sealed JBX size 2). 44 Push-Pull connectors Accessories JAX-JBX * Locking washer Dimensions Part number Shell size OA OB C D JAX RE 0 0 9.2 12.5 0.6 1 JAX RE 1 1 12.2 16 0.6 1 JBX RE 2 2 16 19.8 0.6 1 Piece parts JBX-JKX * Crimp contacts (if ordered separately) Shell size O contact 0 0.9 0.7 1.3 0.9 0.7 2 1.6 1.3 0.9 0.7 2 1.6 1.3 0.9 0.7 1 2 3 * Solder contacts (if ordered separately) Shell size O contact 0 0.9 1.3 0.9 2 1.6 1.3 0.9 2 1.6 1.3 0.9 1 2 3 Part Number Crimp pin Crimp socket JBX 0 CT MC 09 JBX 0 CT FC 09 JBX 0 CT MC 07 JBX 0 CT FC 07 JBX 1 CT MC 13 JBX 1 CT FC 13 JBX 1 CT MC 09 JBX 1 CT FC 09 JBX 1 CT MC 07 JBX 1 CT FC 07 JBX 2 CT MC 20 JBX 2 CT FC 20 JBX 2 CT MC 16 JBX 2 CT FC 16 JBX 2 CT MC 13 JBX 2 CT FC 13 JBX 2 CT MC 09 JBX 2 CT FC 09 JBX 2 CT MC 07 JBX 2 CT FC 07 JBX 3 CT MC 20 JBX 3 CT FC 20 JBX 3 CT MC 16 JBX 3 CT FC 16 JBX 3 CT MC 13 JBX 3 CT FC 13 JBX 3 CT MC 09 JBX 3 CT FC 09 JBX 3 CT MC 07 JBX 3 CT FC 07 Part Number Solder pin Solder socket JBX 0 CT MS 09 JBX 0 CT FS 09 JBX 1 CT MS 13 JBX 1 CT FS 13 JBX 1 CT MS 09 JBX 1 CT FS 09 JBX 2 CT MS 20 JBX 2 CT FS 20 JBX 2 CT MS 16 JBX 2 CT FS 16 JBX 2 CT MS 13 JBX 2 CT FS 13 JBX 2 CT MS 09 JBX 2 CT FS 09 JBX 3 CT MS 20 JBX 3 CT FS 20 JBX 3 CT MS 16 JBX 3 CT FS 16 JBX 3 CT MS 13 JBX 3 CT FS 13 JBX 3 CT MS 09 JBX 3 CT FS 09 Solder contacts of 0.5 mm and 0.7 mm diameter not available separately (always fixed into the insulator). 45 Push-Pull connectors Piece parts JBX-JKX * Inserts for removable solder and crimp contacts Shell size 0 1 2 3 Insert 02 03 04 05 02 03 04 05 06 07 08 02 03 04 05 06 07 08 10 12 16 18 19 03 04 07 10 14 18 22 30 (if ordered separately) Insert Part Number Pin contacts Socket contacts JBX 0 BI 02 MS JBX 0 BI 02 FS JBX 0 BI 03 MS JBX 0 BI 03 FS JBX 0 BI 04 MS JBX 0 BI 04 FS JBX 0 BI 05 MS JBX 0 BI 05 FS JBX 1 BI 02 MS JBX 1 BI 02 FS JBX 1 BI 03 MS JBX 1 BI 03 FS JBX 1 BI 04 MS JBX 1 BI 04 FS JBX 1 BI 05 MS JBX 1 BI 05 FS JBX 1 BI 06 MS JBX 1 BI 06 FS JBX 1 BI 07 MS JBX 1 BI 07 FS JBX 1 BI 08 MS JBX 1 BI 08 FS JBX 2 BI 02 MS JBX 2 BI 02 FS JBX 2 BI 03 MS JBX 2 BI 03 FS JBX 2 BI 04 MS JBX 2 BI 04 FS JBX 2 BI 05 MS JBX 2 BI 05 FS JBX 2 BI 06 MS JBX 2 BI 06 FS JBX 2 BI 07 MS JBX 2 BI 07 FS JBX 2 BI 08 MS JBX 2 BI 08 FS JBX 2 BI 10 MS JBX 2 BI 10 FS JBX 2 BI 12 MS JBX 2 BI 12 FS JBX 2 BI 16 MS JBX 2 BI 16 FS JBX 2 BI 18 MS JBX 2 BI 18 FS JBX 2 BI 19 MS JBX 2 BI 19 FS JBX 3 BI 03 MS JBX 3 BI 03 FS JBX 3 BI 04 MS JBX 3 BI 04 FS JBX 3 BI 07 MS JBX 3 BI 07 FS JBX 3 BI 10 MS JBX 3 BI 10 FS JBX 3 BI 14 MS JBX 3 BI 14 FS JBX 3 BI 18 MS JBX 3 BI 18 FS JBX 3 BI 22 MS JBX 3 BI 22 FS JBX 3 BI 30 MS JBX 3 BI 30 FS 46 Insert for pin contacts Insert for socket contacts Push-Pull connectors * Inserts with fixed solder contacts Shell size Insert 00 04 04 05 06 07 07 08 10 12 16 18 19 22 30 0 1 2 3 (if ordered separately) Insert Part Number Pin contacts Socket contacts JBX 00 BI 04 MPS JBX 0 BI 04 MSS JBX 0 BI 05 MSS JBX 0 BI 06 MPS JBX 0 BI 07 MPS JBX 1 BI 07 MSS JBX 1 BI 08 MSS JBX 1 BI 10 MPS JBX 2 BI 12 MSS JBX 2 BI 16 MSS JBX 2 BI 18 MSS JBX 2 BI 19 MSS JBX 3 BI 22 MSS JBX 3 BI 30 MSS JBX 00 BI 04 FPS JBX 0 BI 04 FSS JBX 0 BI 05 FSS JBX 0 BI 06 FPS JBX 0 BI 07 FPS JBX 1 BI 07 FSS JBX 1 BI 08 FSS JBX 1 BI 10 FPS JBX 2 BI 12 FSS JBX 2 BI 16 FSS JBX 2 BI 18 FSS JBX 2 BI 19 FSS JBX 3 BI 22 FSS JBX 3 BI 30 FSS Insert for pin contacts Insert for socket contacts Toolings JBX - JKX * Manual extraction tools Contacts automatically extracted The extraction tool is similar for both male and female contacts. Shell size O Contacts 0.7 0.9 0.7 0.9 0 1 2 3 The contact is automatically extracted without the need of pulling onto the cable. 47 SOURIAU Part number ASTRO Part number JBX OUT DC 07 ATJP 2045 JBX OUT DC 09 ATJP 2057 JBX OUT DC 07 ATJP2045 JBX OUT DC 09 ATJP 2057 1.3 0.7 0.9 1.3 1.6 2.0 0.7 JBX OUT DC 13 JBX OUT DC 07 JBX OUT DC 09 JBX OUT DC 13 JBX OUT DC 16 JBX OUT DC 20 JBX OUT DC 07 ATJP 2077 ATJP 2045 ATJP 2057 ATJP 2077 ATJP 2095 ATJP 2115 ATJP 2045 0.9 1.3 1.6 2.0 JBX OUT DC 09 JBX OUT DC 13 JBX OUT DC 16 JBX OUT DC 20 ATJP 2057 ATJP 2077 ATJP 2095 ATJP 2115 Push-Pull connectors Toolings JBX - JKX * Crimping tool Specifications MIL-C-22520 / 7.01 MIL P/N - SOURIAU P/N Supplier P/N MIL-22520/7-01 Daniels : MH860 Buchanan : 616 336 MIL P/N - SOURIAU P/N Supplier P/N MIL-22520/1-01 Daniels : AF8 Buchanan : 615 708 Contacts 0.7 mm - 0.9 mm and 1.3 mm Specifications MIL-C-22520 / 1.01 Contacts 1.6 mm and 2 mm * Locator for pin and socket 0.7 - 0.9 mm and 1.3 mm contacts Shell size 0 1 2 3 O contacts AWG 0.7 0.9 0.7 0.9 1.3 0.7 0.9 1.3 0.7 0.9 1.3 22 - 24 - 26 20 - 22 - 24 22 - 24 - 26 20 - 22 - 24 18 - 20 - 22 22 - 24 - 26 20 - 22 - 24 18 - 20 - 22 22 - 24 - 26 20 - 22 - 24 18 - 20 - 22 Male contact SOURIAU P/N DANIELS P/N JBX 0 OUT LP07 86 - 223 JBX 0 OUT LP09 86 - 225 JBX 1 OUT LP07 86 - 196 JBX 1 OUT LP09 86 - 198 JBX 1 OUT LP13 86 - 200 JBX 2 OUT LP07 86 - 202 JBX 2 OUT LP09 86 - 204 JBX 2 OUT LP13 86 - 206 JBX 3 OUT LP07 86 - 217 JBX 3 OUT LP09 86 - 218 JBX 3 OUT LP13 86 - 219 ASTRO P/N / / 642 - 001 642 - 002 642 - 003 642 - 007 642 - 008 642 - 009 642 - 014 642 - 015 642 - 016 Female contact SOURIAU P/N DANIELS P/N JBX 0 OUT LS07 86 - 224 JBX 0 OUT LS09 86 - 226 JBX 1 OUT LS07 86 - 197 JBX 1 OUT LS09 86 - 199 JBX 1 OUT LS13 86 - 201 JBX 2 OUT LS07 86 - 203 JBX 2 OUT LS09 86 - 205 JBX 2 OUT LS13 86 - 207 JBX 3 OUT LS07 86 - 214 JBX 3 OUT LS09 86 - 215 JBX 3 OUT LS13 86 - 216 ASTRO P/N / / 642 - 004 642 - 005 642 - 006 642 - 010 642 - 011 642 - 012 642 - 017 642 - 018 642 - 019 * Turret with locator for pin and socket 1.6 mm and 2 mm contacts Shell size 2 3 O contacts AWG 1.6 2 1.6 2 14 - 16 - 18 12 - 14 - 16 14 - 16 - 18 12 - 14 - 16 48 Male and female contacts SOURIAU P/N DANIELS P/N ASTRO P/N JBX 2 OUT LT16 TH 564 650 - 030 JBX 2 OUT LT20 TH 565 650 - 031 JBX 3 OUT LT16 TH 566 650 - 038 JBX 3 OUT LT20 TH 567 650 - 035 More about our know-how Examples of custom designs derivated from standard connectors lines * Watertight receptacles * JBX series: Custom watertight receptacles designed to customer requirements * Black finish plating * JBX and JKX series, black chrome plating Applications: Military radiocommunication 49 Push-Pull connectors Request form please fill in and fax to SOURIAU - Customer service (see the address page for your local contact) Name : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel number : . . . . . . . . . . . . . . . . Fax number : . . . . . . . . . . . Title : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-mail : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Company : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Address : ................................................................................... Applications : Medical Audio Video Instrumentation Nuclear physics GPS Transportation Metrology Other ............................................................. Detailed description of end product, unit or application ....................................................................................... Connector description : Series : . . . . . . . . . . . . . . . . . . . . . . . . . Shell configuration : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shell size : . . . . . . . . . . . . . . . . . . . . . Protective boot : . . . . . . . . . . . . . . . . . . . . . Color : . . . . . . . . . . . . . . . Number of contacts : . . . . . . . . . . . . . . Type of contacts : Solder . . . . . . . . . . Crimp . . . . . Printed circuit . . . . . . . . . . 90 printed circuit Conductor AWG : . . . . . . . . . . . . . . . . . Coax type : . . . . . . . . . . . . . . . . . . . . . . . . Other : . . . . . . . . . . . . . . Electrical : Working voltage (AC/DC) :. . . . . . . . . . . Current rating : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Impedance (Ohms) : . . . . . . . . . . . . . . . SWR : . . . . . . . . . . . . . . . . . . . . . . . Frequency . . . . . . . . . . . . . . . . . Contact resistance : . . . . . . . . . . . . . . . . Shielding : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fibre optics : Multimode . . . . . . . . . . . . . . . . . . . . . . . Monomode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environment : Temperature : . . . . . . . . . . . . . . . . . . . . Protection index (IP -- ) : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Outside environment : Clear . . . . . . . . . . . . . . . Splash proof . . . . . . . . . . . . . . . . . . . Sterilization . . . . . . . . . . . . . . . . Dirt . . . . . . . . . . . . . . . . Fluids . . . . . . . . . . . . . . . . . . . . . . . . Radiation . . . . . . . . . . . . . . . . . . Chemicals . . . . . . . . . . . Waterproof . . . . . . . . . . . . . . . . . . . . Gases . . . . . . . . . . . . . . . . . . . . Salt waterspray . . . . . . . Projections : Prototype quantity : . . . . . . . . . . . . . . . . . . . . . . . . . . . . Delivery date : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preseries quantity : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Delivery date : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Production quantity : . . . . . . . . . . . . . . . . . . . . . . . . . . . . Delivery date : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Production per year : . . . . . . . . . . . . . . . . . . . . . . . . . . . Number of years : . . . . . . . . . . . . . . . . . . . . . . . . . . . . Target pricing per connector : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Push-Pull connectors Conversion Table * Millimeters / Inches * C/F (mm) (inches) (mm) (inches) (mm) (inches) (C) (F) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4.0 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5.0 5.2 5.4 5.6 5.8 6.0 6.2 6.4 6.6 6.8 7.0 7.2 7.4 7.6 7.8 8.0 0.00394 0.00788 0.01182 0.01576 0.01970 0.02364 0.02758 0.03152 0.03546 0.03940 0.04334 0.04728 0.05122 0.05516 0.05910 0.06304 0.06698 0.07092 0.07486 0.07880 0.08274 0.08668 0.09062 0.09456 0.09850 0.10244 0.10638 0.11032 0.11426 0.11820 0.12214 0.12608 0.13002 0.13396 0.13790 0.14184 0.14578 0.14972 0.15366 0.15760 0.16154 0.16548 0.16942 0.17336 0.17730 0.18124 0.18518 0.18912 0.19306 0.19700 0.20488 0.21276 0.22064 0.22852 0.23640 0.24428 0.25216 0.26004 0.26792 0.27580 0.28368 0.29156 0.29944 0.30732 0.31520 8.2 8.4 8.6 8.8 9.0 9.2 9.4 9.6 9.8 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 14.5 15.0 15.5 16.0 16.5 17.0 17.5 18.0 18.5 19.0 19.5 20.0 20.5 21.0 21.5 22.0 22.5 23.0 23.5 24.0 24.5 25.0 25.5 26.0 26.5 27.0 27.5 28.0 28.5 29.0 29.5 30.0 30.5 31.0 31.5 32.0 32.5 33.0 33.5 34.0 34.5 35.0 35.5 36.0 36.5 37.0 37.5 0.32308 0.33096 0.33884 0.34672 0.35460 0.36248 0.37036 0.37824 0.38612 0.39400 0.41370 0.43340 0.45310 0.47280 0.49250 0.51220 0.53190 0.55160 0.57130 0.59100 0.61070 0.63040 0.65010 0.66980 0.68950 0.70920 0.72890 0.74860 0.76830 0.78800 0.80770 0.82740 0.84710 0.86680 0.88650 0.90620 0.92590 0.94560 0.96530 0.98500 1.00470 1.02440 1.04410 1.06380 1.08350 1.10320 1.12290 1.14260 1.16230 1.18200 1.20170 1.22140 1.24110 1.26080 1.28050 1.30020 1.31990 1.33960 1.35930 1.37900 1.39870 1.41840 1.43810 1.45780 1.47750 38.0 38.5 39.0 39.5 40.0 40.5 41.0 41.5 42.0 42.5 43.0 43.5 44.0 44.5 45.0 45.5 46.0 46.5 47.0 47.5 48.0 48.5 49.0 49.5 50.0 51.0 52.0 53.0 54.0 55.0 56.0 57.0 58.0 59.0 60.0 61.0 62.0 63.0 64.0 65.0 66.0 67.0 68.0 69.0 70.0 71.0 72.0 73.0 74.0 75.0 80.0 85.0 90.0 100.0 200.0 400.0 600.0 800.0 1000.0 1200.0 1600.0 2000.0 3200.0 1.49720 1.51690 1.53660 1.55630 1.57600 1.59570 1.61540 1.63510 1.65480 1.67450 1.69420 1.71390 1.73360 1.75330 1.77300 1.79270 1.81240 1.83210 1.85180 1.87150 1.89120 1.91090 1.93060 1.95030 1.97000 2.00940 2.04880 2.08820 2.12760 2.16700 2.20640 2.24580 2.28520 2.32460 2.36400 2.40340 2.44280 2.48220 2.52160 2.56100 2.60040 2.63980 2.67920 2.71860 2.75800 2.79740 2.83680 2.87620 2.91560 2.95500 3.15200 3.34900 3.54600 3.94000 7.88000 15.76000 23.64000 31.52000 39.40000 47.28000 63.04000 78.80000 126.08000 - 70 - 65 - 55 - 50 - 40 0 37 80 125 150 170 200 250 - 94 - 85 - 67 - 58 - 40 32 98.6 176 257 302 338 392 482 * Pressure conversion bar 10 5 2 1 0.5 0.1 psi 145.0 72.5 29.0 14.5 7.2 1.4 mmHg (torr) 7600 3800 1520 760 380 76 mbar 100 50 10 1.32 psi 1.4 0.72 0.14 0.019 torr (mmHg) 76 38 7.6 1