2
Push-Pull connectors
Introduction
This catalog presents the push-pull connectors ranges for industrial applications.
These products are particularly suitable for high reliability and high quality applications where a simple yet fast method to
connect/disconnect is required. Also suitable for high endurance and ease of operation in very limited spaces. The aesthetics
of the product allows for perfect integration on front panel equipments.
SOURIAU offers 3 main series of metallic circular connectors :
JBX series : basic push-pull series for signal transmission
JKX series : environmental version of the JBX series sealed to IP68
JAX series : complementary range including coaxial contact layouts.
Contents
Where and why push-pull................................................................................................3
Selection guide.................................................................................................................4
JBX series
• Main features - Part number system.................................................................................5
• Shell types and dimensions..........................................................................................6-8
• Keying..............................................................................................................................9
• Contact layouts.........................................................................................................10-12
• Options...........................................................................................................................13
• Technical characteristics................................................................................................14
• Wiring and assembly instructions..............................................................................15-19
JAX series
• Main features - Part number system...............................................................................20
• Shell types and dimensions............................................................................................21
• Contact layouts..............................................................................................................22
• Suffix for cable outside diameter - Options...................................................................23
• Technical characteristics................................................................................................24
• JAX camac series.....................................................................................................25-26
• Wiring and assembly instructions.............................................................................27-30
JKX series
• Main features - Part number system...............................................................................31
• Shell types and dimensions............................................................................................32
• Keying - contact layouts.................................................................................................33
• Options...........................................................................................................................34
• Technical characteristics................................................................................................35
• Wiring and assembly instructions..............................................................................36-39
JBX series-sealed version size 2
• Main features - Part number system...............................................................................40
• Shell types and dimensions............................................................................................41
• Keying - contact layouts.................................................................................................42
• Technical informations....................................................................................................43
Accessories - Piece parts.........................................................................................44-46
Toolings......................................................................................................................47-48
More about our know-how.............................................................................................49
Requirement form...........................................................................................................50
Conversion table.............................................................................................................51
All dimensions are in mm
Medical
Professional audio-video
Instrumentation
Extremely fast
and easy to use
A thousand matings/
unmatings.
Quality aesthetics for
more value added
on the equipment
Space saving
GPS
3
Push-Pull connectors
Telecommunications
Where and Why
push-pull ?
4
Selection Guide
Push-Pull
Unsealed Sealed
Coaxial Multipin Multipin
Keyed
2 to 10 contacts
Keyed
until 19 contacts
Not keyed
1 to 14
contacts
Keyed
2 to 30
contacts
Keyed
2 to 30
contacts
The locking of the plug into the receptacle
is achieved by a simple axial push on the
outer shell.
Connection cannot be broken by pulling
the cable or any other parts of the plug
than the outer shell.
To unmate the plug from the receptacle,
just pull axially the outer shell.
Push-pull locking system
Brass Brass Brass Brass
Tefzel for coaxial contact
Nylatron for multipin
layout
Fortron
Peek for layout with
contacts of 0.5 mm of Ø
Fortron
Peek for layout with
contacts of 0.5 mm of Ø
Fortron
Peek for layout with
contacts of 0.5 mm of Ø
Shielded
(65 dB up to 100 MHz) Shielded
(55 dB up to 100 MHz) Shielded
(55 dB up to 100 MHz) Shielded
(55 dB up to 100 MHz)
> 1000 cycles > 1000 cycles > 1000 cycles > 1000 cycles
up to 30 A up to 30 A up to 15 A up to 30 A
- 40°C ; + 125°C
(- 40°F ; + 257°F) - 50°C ; + 125°C
(- 58°F ; + 257°F) - 50°C ; + 125°C
(- 58°F ; + 257°F) - 40°C ; + 80°C
(- 40°F ; + 176°F)
IP 40 IP 40 IP 68 when mated IP 67
JAX Camac connectors
(coaxial, size 00) (optional
sealed version : consult us)
Shell material
Insulator material
Shielding
Endurance
Current rating
Temperature
range
Protection index
Specific version
Solder Crimp or
PCB contacts Solder,
crimp or PCB contacts
JAX series JBX series JKX series Sealed JBX size 2
UL approved
5
JBX Series
S D SCM05G1FD
JBX M
Basic series
Shell type FD-FC-ER-EA-SR-PC-ED-EP-EZ
Shell size 00 - 0 - 1 - 2 - 3
Keying G - J - A - B & customs are available
Contact layout 02 ---------- 30
Contact type M: pin F: socket
Contact termination C: crimp ; S: solder ; P* : straight PCB tails ; Q* : 90° PCB tails ;
W: 0.7 mm clipped solder
Material & surface plating S: Outer shell in brass alloy with chrome over nickel
N: Outer shell in brass alloy with black plating
D: Obligatory suffix
S: Insulator in PPS
P: insulator in PEEK
Options M: Connector with backnut for protective boot - Protective boot to order separately page 13
R : Red dot (possible for FD, FC, PC, SR, ER, ED, EZ only)
Mechanically keyed : ensures correct polarisation
and alignment.
• Contact layouts from 2 to 30 contacts.
• Wire gauges range from 30 AWG to 12 AWG.
• High contact density in a small space.
• Contact termination in either crimp, solder or PCB
contacts.
Key features
Part number system
User advantages
Blister packaging
6-collet cluster
Allows a wide range of cable diameter
applications for a single connector.
Reduces inventory variations
Removable contacts
Available crimp versions allow easier
wiring and maintenance.
JBX Series
* For receptacles with female contacts only
6
JBX Series
Shell types
ER : fixed receptacle,front panel mounting, fixed
front flange
EA : fixed receptacle, back or front panel mounting,
double nuts fixing (appropriate with 90° contacts
for PCB)
FN : straight plug with cable clamping & lanyard
FD : straight plug with cable clamping
FC : 90° elbow ºplug with cable clamping
EP : fixed receptacle, back panel mounting, fixed rear
panel flange (appropriate with 90° contacts for
PCB)
ED : fixed receptacle, protruding shell, fixed front flange
SR : fixed receptacle with cable clamping, front panel
mounting, fixed front flange
SA : fixed receptacle with cable clamping, front or back
panel mounting
PC : cable mounted receptacle
EZ : straight receptacle for PCB
7
JBX Series
Dimensions*
FD : Straight plug
Size
A
B
Ø
C
00
31
23
7
0
39
29
10
1
45
34
12
2
52
40
15
3
62
47
18
FC : 90° elbow plug
Size
A
B
C
ØD
0
30.5
20.5
29.5
10
1
36.5
25.5
33.5
12
2
42.5
30.5
36.5
15
3
50.5
35.5
45
18
ER : Fixed receptacle,
front panel mounting*
*Lock washer not available *Lock washer not available
*Lock washer not available
Size
A
B
C
ØD
00
14
6
0.8
8
0
19
8
1.2
10
1
21
10
1.5
14
2
24
10
1.8
18
3*
28
12
2.0
22
EA : Double nut receptacle*
Size
A
B
C
ØD
0
19
6.7
2.5
12
1
21
8.3
3.2
16
2
24
8
3.8
20
3*
28
9.5
4.5
24
SR : Cable clamp receptacle*
Size
A
B
C
ØD
0
38
8
1.2
10
1
43
10
1.5
14
2
50
10
1.8
18
3
59
12
2
22
PC : Cable mounted receptacle
Size
A
ØB
0
38
10
1
43
13
2
50
16
3
59
19.5
EP : Fixed receptacle,
back panel mounting
Size
A
B
C
Ø
D
0
19
4.5
2.5
12
1
21
6
3.2
16
2
24
6.5
3.8
20
ED : Protruding receptacle
Size
A
B
C
Ø
D
0
19
3
1.2
10
1
21
4.5
1.5
14
2
24
6.3
1.8
18
EZ : Receptacle for PCB
Size
Ø
A
B
C
D
Ø
E
0
10
19
4
7.62 sq.
1.1
1
12
21
4
7.62 sq.
1.1
JBX Series
*All dimensions in mm.
8
JBX Series
Dimensions
• Special custom shells
FN : Straight plug,
shell 0 with a lanyard
FM : 90° elbow plug,
shell 0 with a lanyard
FF : Straight plug,
with no latching, size 1
SA : fixed receptacle with cable clamping,
front or back panel mounting
9
JBX Series
JB
Key G A
sizes 0 - 1 sizes 2 - 3 sizes 0 - 1
Keying angle 45° 37.5° 30° 60°
Plug
Receptacle
JBX Series are mechanically keyed to ensure correct alignment of the inserts before the contacts mate.
«G» : standard keying
«J» : standard reverse gender keying ; plugs with socket contacts, receptacles with pin contacts.
*G& Jare standard keying, but all keying configurations can use standard or reverse gender.
Keying
• Keying angles
• Keyed shells availability
Shell size Key ER EA ED EP EZ SR PC FD FC FM FN SA
G ●● ●●●●
J●●
0A●●
B●●
G ●● ●●
1J●●
A●●
G●●●●
2J●●
A●●
3G●● ●●
Available for JBX series, customs can be ordered contact Project Management.
JBX Series
00 G●●
10
JBX Series
Contact layouts
• Multi contact inserts
Male AWG Max. Testing Working
Shell insulator Contact SCP*Q*Ø Solder Crimp current voltage voltage
size viewed from layout solder crimp straight 90° Contact wire wire rating (Vdc /
wiring side PCB tails PCB tails Max. Max. (A)* (Vrms)* Vrms)*
04 S 0.5 30 - 2 1000 500/350
02 S C P Q 0.9 24 20 10 1400 660/460
03 S C P Q 0.9 24 20 8 1300 600/420
04 S C P Q 0.7 26 22 7 1400 660/460
05 S C P Q 0.7 26 22 6.5 800 400/260
06 S P 0.5 28 - 2.5 680 320/220
07 S P 0.5 28 - 2.5 680 320/220
02 S C P 1.3 20 18 15 1600 760/530
03 S C P Q 1.3 20 18 12 1300 600/420
04 S C P Q 0.9 24 20 10 1900 900/630
05 S C P Q 0.9 24 20 9 1400 660/460
06 S C P Q 0.7 26 22 7 1400 660/460
07 S C P Q 0.7 26 22 7 1400 660/460
08 S C P Q 0.7 26 22 5 1200 600/420
10 S 0.5 28 - 2.5 600 300/200
Inserts with fixed contacts (non removable contacts).
* For receptacles with female contacts only.
Contact types available
00
0
1
11
JBX Series
Contact layouts
• Multi contact inserts
Male AWG Max. Testing Working
Shell insulator Contact SCP*Q*Ø Solder Crimp current voltage voltage
size viewed from layout solder crimp straight 90° Contact wire wire rating (Vdc /
wiring side PCB tails PCB tails Max. Max. (A)* (Vrms)* Vrms)*
02 S C 2 16 12 30 2100 1000/700
03 S C 1.6 18 14 17 1700 830/560
04 S C P Q 1.3 20 18 15 2400 1000/800
05 S C P Q 1.3 20 18 14 1900 900/630
06 S C P Q 1.3 20 18 12 1900 900/630
07 S C P Q 1.3 20 18 11 1500 730/500
08 S C P Q 0.9 24 20 10 1700 830/560
10 S C P Q 0.9 24 20 8 1700 830/560
12 S C P Q 0.7 26 22 7 1700 830/560
16 S C P Q 0.7 26 22 6 1500 730/500
18 S C P 0.7 26 22 5.5 1400 660/460
19 S C P 0.7 26 22 5 1400 660/460
03 S C 2 16 12 25 3600 1600/1200
04 S C 2 16 12 25 2500 1100/830
Inserts with fixed contacts (non removable contacts).
* For receptacles with female contacts.
Contact types available
2
3
JBX Series
12
JBX Series
• Voltage Test Procedure
- The testing voltage corresponds to the maximum voltage the connector is able to withstand in normal climatic conditions.
The value is about 75% of the electrical breakdown voltage. The testing voltage level can be reached several times in
connectors life, but never applied for a continuous duration.
- The working voltage corresponds to the maximum voltage the connector is able to withstand continuously during its life
time, in real environmental conditions, even with high temperature. The value is around 1/3 of the testing voltage.
• Maximum current rating
- This indicated maximum current rating corresponds to the maximum current that can be continuously applied to the connector
mated pair, in normal climatic conditions.
Remark : If the current is applied on only one contact of the layout, then an increased current value can be achieved over a long
duration.
Inserts with fixed contacts (non removable contacts).
* For receptacles with female contacts.
Note : Contacts are numbered counter clock wise in the plug and clock wise in the receptacle.
Contact layouts
• Multi contact inserts
Male AWG Max. Testing Working
Shell insulator Contact SCP*Q*Ø Solder Crimp current voltage voltage
size viewed from layout solder crimp straight 90° Contact wire wire rating (Vdc /
wiring side side PCB tails PCB tails Max. Max. (A)* (Vrms)* Vrms)*
07 S C 1.6 18 14 15 2200 1000/730
10 S C 1.3 20 18 12 1400 660/460
14 S C P 0.9 24 20 9 1700 830/560
18 S C P 0.9 24 20 7 1400 660/460
22 S C P 0.7 26 22 5.5 1200 560/400
30 S C P 0.7 26 26 3.5 800 400/260
Contact types available
3
13
JBX Series
Options
• Protective boot
• Receptacle caps : an effective protection against dust
With each JBX connector, one protective boot can accept multiple cable diameters thus the
end-user can use various cable diameters without the need of multiple part numbers.
Parts that require a protective boot
need to be ordered with an M suffix,
see page 5. Protective boots are
ordered separately.
Material :
ELASTOLLAN (PUR)
Working temperature :
- 40°C ; + 80°C
- 40°F ; + 176°F
Dimensions
Part Shell
number size ØAL ØCâble
min Max.
JBX 00 MPN 00 1.5 15 1 3.5
JBX 0 MP* 0 2.2 20 1.5 5.5
JBX 1 MP* 1 2.6 25 2 7.5
JBX 2 MP* 2 4 30 3.5 9.7
JBX 3 MP* 3 5 35 4.9 12
Color code Colors
A blue
B white
G grey
J yellow
M brown
N black
R red
V green
O orange
* Color code / In size 00, available only in black
Part number Ø
JBX BR0 12 mm
JBX BR1 14 mm
JBX BR2 17 mm
JBX BR3 20 mm
JBX Series
14
JBX Series
• Mechanical and climatics
Component Material Standard Surface treatment (µm)
ISO ASTM Cr Ni Au
Outer shell and collet nut Brass CuZn40Pb3 C38500/C3600 0.1 - 0.6 5 - 8 -
Latching sleeve & metal collet Brass CuZn40Pb3 C38500/C3600 - 5 - 8 -
Shielding ring Brass CuZn40Pb3 C38500/C3600 - 3 - 7 -
Nut Brass CuZn40Pb3 C38500/C3600 5 - 8 -
Half bushes Brass CuZn40Pb3 C38500/C3600 - 5 - 8 -
Socket contact (1) Copper Nickel- CuNi1Pb1P CDA C 19150 - 3 - 5 0.5
Pin contact (1) Brass CuZn35Pb2 C35300/C3600 - 3 - 5 0.5
Clip Beryllium copper CuBe1,9 C17200 - - -
Component Material Color Working Temperature
Insert PPS + 40%GF black - 65°C + 200°C - 85°F + 392°F
or PEEK + 15%GF brown - 50°C + 250°C - 58°F + 482°F
Plastic collet PA 6/6 + MoS2 black - 55°C + 125°C - 67°F + 257°F
Characteristics Values Standard Method
Endurance > 1000 cycles (except for 0.7 mm crimp contacts for which MIL-STD 2016.1
endurance is limited to 500 cycles) 1344A
Shock 50 g, duration 6 ms ; contact Ø 0.7 mm and 0.9 mm MIL-STD 2004.1
100 g, duration 6 ms ; contact Ø 1.3 mm - 1.6 mm and 2 mm 1344A
Vibrations 10 to 2000 Hz γ= 15 g, contact Ø 0.7 mm and 0.9 mm MIL-STD 2005.1
γ= 20 g, contact Ø1.3 mm - 1.6 mm and 2 mm 1344A
Protection index IP 40 CEI 529
- 55°C + 125°C
with plastic collets - 67°F + 257°F --
Operating temperature
with optional metal collets - 55°C + 200°C
- 67°F + 392°F - -
Gas H2S : 100 ppb ± 20 ppb IEC test Ke
SO2: 500 ppb ± 100 ppb 68-2-60 method 1
Radiation stability 108Rad - -
(1) Gold thickness as per MIL-G-45204C type 1, class 00.
}
}
Technical characteristics
• Material and treatment
169916
JBX Series
Wiring and assembly instructions
• Panel cutout
Size
Ø A
B
00
7.1
6.4
0
9.1
8.3
1
12.1
10.6
2
15.1
13.6
3
18.1
16.6
• Removable contacts
Crimp contacts
Solder contacts
Contact Usable cables Max. Contact Endurance
Core section (mm
2
)current resistance (number
ØCØF AWG rating (A) (m) of cycles)
min Max.
0.7 0.85 0.129 0.326 22-24-26 7 5 500 Max.
0.9 1.1 0.205 0.518 20-22-24 10 3.5 > 1000
1.3 1.4 0.326 0.823 18-20-22 15 3 > 1000
1.6 1.9 0.823 2.081 14-16-18 17 2.5 > 1000
2.0 2.4 1.309 3.309 12-14-16 30 2.5 > 1000
Contact Usable cables Max. Contact Endurance
Core section (mm
2
)current resistance (number
ØCØF AWG rating (A) (m) of cycles)
min Max.
0.9 0.8
-
0.21 24 10 3.5 > 1000
1.3 1.1
-
0.60 20 15 3 > 1000
1.6 1.5
-
0.93 18 17 2.5 > 1000
2 1.9
-
1.34 16 30 2.5 > 1000
0.7 1.0
-
0.3 22.0 7.0 5.0 500 Max.
The conductor bucket on the solder contacts is designed with an angle to form a cup into which the solder can flow easily.
• Fixed contacts
Solder contacts
Contact Usable cables Max. Contact Endurance
Shell
Core section
current resistance (number
Ø
C
Ø
F size
(mm2) Max.
AWG rating (A) (m) of cycles)
0.5 0.4 00 0.06 30 5 10 > 1000
0.5 0 - 1 0.096 28
0.7 0.63 0 - 1 - 2 - 3 0.15 26 7 5 > 1000
Contacts for PCB
Contacts for PCB Contact length dimensions “L”
PCB tail length size 0 dimension “L” 5.5 mm
0.7 mm female PCB tail length size 0 dimension “L” 3.5 mm
0.7 mm female PCB tail length size 1 dimension “L” 4.0 mm
0.7 mm female PCB tail length size 2 dimension “L” 6.0 mm
0.7 mm female PCB tail length size 3 dimension “L” 6.0 mm
0.9 mm female PCB tail length size 0 dimension “L” 3.5 mm
0.9 mm female PCB tail length size 1 dimension “L” 4.0 mm
0.9 mm female PCB tail length size 2 dimension “L” 6.0 mm
4.3 mm female PCB tail length size 1 dimension “L” 4.0 mm, dimension “F” 0.7 mm
1.3 mm female PCB tail length size 2 dimension “L” 6.0 mm, dimension “F” 0.7 mm
1.3 mm female PCB tail length size 3 dimension “L” 6.0 mm, dimension “F” 0.7 mm
JBX Series
15
16
JBX Series
Wiring and assembly instructions
• Cable stripping for connectors with crimp contacts
• Cable stripping for connectors with solder contacts
Stripping for FD, SR, PC Stripping for FC
LCTLCT
Shell size Ø contacts Ø I
0
1
2
3
Stripping for FD, SR, PC
LSTLST
0
.
5924/ / /
0
.
5112 7162 7
0
.
7123 7163 7
0
.
9123 7163 7
0
.
5122 8192 8
0
.
7133 8193 8
0
.
9133 8193 8
1
.
3 13 3.5 8 19 3.5 8
0
.
7163 9253 9
0
.
9163 9253 9
1
.
3 16 3.5 9 25 3.5 9
1
.
6184 9254 9
2184 9254 9
0
.
7 20 3 10 30 3 10
0
.
9 20 3 10 30 3 10
1
.
3 20 3.5 10 30 3.5 10
1
.
6 22 4 10 30 4 10
2 22 4 10 30 4 10
Stripping for FC
00
0
1
2
3
4
5.5 4
5.5
0.7 15 7 19 7
1.35
> 1.35 4
5.5 4
5.5
0.9 15 7 19 7
1.6
> 1.6 4
5.5 4
5.5
0.7 16 8 22 8
1.35
> 1.35 4
5.5 4
5.5
0.9 16 8 22 8
1.6
> 1.6 4
5.5 4
5.5
1.3 16 8 22 8
2.1
> 2.1 4
5.5 4
5.5
0.7 19 9 28 9
1.35
> 1.35 4
5.5 4
5.5
0.9 19 9 28 9
1.6
> 1.6 4
5.5 4
5.5
1.3 19 9 28 9
2.1
> 2.1 5.5
75.5
7
1.6 21 9 28 9
2.6
> 2.6 5.5
75.5
7
2.0 21 9 28 9
3.2
> 3.2 4
74
7
0.725103510
1.35
> 1.35 4
74
7
0.925103510
1.6
> 1.6 4
74
7
1.325103510
2.1
> 2.1 5.5
8.5 5.5
8.5
1.627103510
2.6
> 2.6 5.5
8.5 5.5
8.5
2.027103510
3.2
> 3.2
ØI : diameter over insulation
Shell size Ø Contacts
17
JBX Series
• Connector preparation 1 - Select the proper collet. (see page 19)
2 - Slide the protective boot the backnut and
the collet over the cable.
Strip end of cable
(see pg. 17).
3 - If a shielded cable is used fold the braid back
over the collet.
• Contacts wiring : crimp contacts
• Contacts wiring : solder contacts
1 - Select the proper crimping tool and
locator. (see page 48)
2 - Adjust the crimping tool based on wire
size “AWG”. (See wire size and crimp
tool settings on the back of the locator)
3 - Crimp the contacts then insert the
contact into the insulator until the clip is
fully seated and cannot be removed.
• Connector assembly
Fixed solder contacts 0.5 mm and 0.7 mm Removable solder contacts from 0.9 mm to 2 mm
1 - Insert wire into solder cup and solder. 1 - Insert wire into solder cup and solder.
2 - Insert contact into the insulator until the clip is fully seated and cannot be removed.
Wiring and assembly
instructions :
STRAIGHT PLUG
1 - Position 2 half bushings on either side of the insulator.
2 - Confirm that the key on the insulator appears through the
window in the one half bushing.
3 - Align the key slot on the collet with the keys on the half
bushings.
4 - Insure the cable shield is still folded back and under the collet.
5 - Insert the insulator subassembly ➀ ➃ & into the
connector housing .
6 - Make sure the window on the half bushing is aligned with the key way on the connector housing .
7 - Apply thread lock to back nut .
8 - Attach the back nut to the connector housing
9 - Use the correct size wrench, see page 19.
10 - Place the wrenches on the flats A and B. Tighten the back nut per the torque spec on page 19.
11 - Install the protective boot if applicable.
JBX Series
Flats B
Window Flats A
18
JBX Series
Wiring and assembly
instructions :
90° ELBOW PLUG
• Connector preparation
1 - Select the proper collet (see page 19).
2 -
Slide the protective boot , the backnut ,
th e collet and the elbow
outlet over the cable.
Strip end of cable (see pg. 17).
3 - If a shielded cable is used, fold the braid back over the collet .
4 - Align the keys in the elbow outlet with the key slot in the collet.
5 - Apply thread lock to the backnut .
6 - Install the back nut and tighten until it bottoms.
• Contacts wiring : crimp contacts
• Contacts wiring : solder contacts
1 - Select the proper crimping tool and locator. (see page 48)
2 - Adjust the crimping tool based on wire size “AWG”. (See wire size and
crimp tool settings on the back of the locator)
3 - Crimp the contacts then insert the contact into the insulator until the
clip is fully seated and cannot be removed.
• Connector assembly : 90 degree plug 1 - Position the ring
over the insulator.
2 - Align the key on the insulator with the key way
on the spacer and insert the insulator into the
spacer.
3 - Insert the insulator sub-assembly into the connector
housing insuring the flats on the elbow outlet
are facing the retaining nut .
4 - Apply thread lock to retaining nut .
5 - Tighten the retaining nut to the recommended
torque on page 19.
Fixed solder contacts 0.5 mm and 0.7 mm Removable solder contacts from 0.9 mm to 2 mm
1 - Insert wire into solder cup and solder. 1 - Insert wire into solder cup and solder.
2 - Insert contact into the insulator until the clip is fully seated and cannot be removed.
Braid
Milled flats A
19
JBX Series
Torque values are the maximum allowable for each connector size.
Torque values will vary due to the type and size of the cable used
*Apply thread lock to back nut prior to assembly.
Note : All the tooling numbers refer to the drawings pages 7 and
8.
• Shielding
Tested according to MIL-STD 1344 A, method 3007
Shell size Electrical continuity
(m)
00 4.5
04
13
22.5
32.5
G
mV
A
4 or 6 collets per shell size are supplied to allow the use of a wide range of cable diameters for each connector. The cable
diameters given on this chart are the minimum and maximum diameters of cable jacket.
*Cable jacket must be inserted at least halfway through the collet.
Metal collets are available as an option in size 0, 1, 2, & 3.
Cable diameter
Shell size 0 Shell size 1 Shell size 2 Shell size 3
11.1 - 1.9 1.5 - 2.5 2.0 - 2.5 3.5 - 4.7 4.9 - 6
2 2 - 2.8 2.6 - 3.5 2.6 - 3.5 4.8 - 5.7 6.1 - 7.2
3 2.9 - 3.5 3.6 - 4.5 3.6 - 4.5 5.8 - 6.7 7.3 - 8.4
4 - 4.6 - 5.5 4.6 - 5.5 6.8 - 7.7 8.5 - 9.6
5 - - 5.6 - 6.6 7.8 - 8.7 9.7 - 10.8
6 - - 6.7 - 7.5 8.8 - 9.7 10.9 - 12.0
Collet
number Shell size 00
1
2
3
5
6
4
Wiring and assembly instructions
• Collet selection according to cable diameters
• Coupling torques
JBX Series
Tools
7 x 0.5 9 x 0.6 12 x 1 15 x 1 18 x 1
Advised torques* in Nm
(jaw dimensions)
Size 00 0 1 2 3 00 0 1 2 3
7 11 14 17 21 0.5 0.7 1.3 1.7 2
6 8 10 13 15 0.7 0.8 1 1.5 2
6 9 11 14 16 0.7 0.8 1 1.5 2
-
10 12 15 17 - 0.4 to 0.5 0.5 to 0.7
-
10 13 17 20 0.5 0.7 1.3 1.7 2
-
91315
------
Discreet application
based on cable
diameter.
Metal collet available
for all sizes
20
JAX Series
BD080M32
F
JAX
Basic series
Shell type F - RA - PC
Shell size 00 - 0 - 1 - 2 - 3
Contact layout - multi contacts : see designation table page 22
- coaxial : see designation table page 22
Suffix for cable outside diameter, see table page 23
B: obligatory suffix
Hermaphroditic insert : prevents
mismatings.
Multipin connectors : contact
layouts from 1 to 14.
Wire gauges range from 26 AWG
to 16 AWG.
High contact density in a small
space.
Coaxial contacts : 50 and 75
impedance.
Part number system
Key features
User advantages
Large range of blind mate coaxial
connectors
21
JAX Series
Shell types
Dimensions
Straight plug - ref. F
Round flange - ref. RA
In line plug - ref. PC
Size
A
Ø B
Ø C
Ø c
D
00
25
6.5
3.2
2.2
17
0
34
9
4.2
2.2
24
1
43
12
6.2
2.2
32
2
51
15
8.2
4.2
39
3
61
18
11.2
4.2
46
Size
A
Ø B
Ø C
D
E
Ø F
G
K
Ø M
L
00
11
8
M7 x 0.5
1
6.5
7.1
3.5
9
6
6.4
0
13.3
10
M9 x 0.6
1.2
7
9.2
3.5
11
8
8.3
1
15
14
M12 x 1
1.5
8
12.2
3
14
10
10.6
2
16.5
18
M15 x 1
1.8
8
15.2
5
17
13
13.6
3
20.5
22
M18 x 1
2
11
18.2
4.5
21
16
16.6
Size
A
B
C
c
00
24
6.5
3.2
2.2
0
33
9
4.2
2.2
1
40
12
6.2
2.2
2
49
15
8.2
4.2
3
59
18
11.2
4.2
RA : fixed receptacle,
front panel mounting, nut fixing
PC : free receptacle, F : straight plug
with cable clamping
JAX Series
JAX Series
Designation to use in the part-number system, page 20
Contact layouts
• Multi contacts inserts
• Coaxial inserts
1UM (plug)
UF
(receptacle) 1.3 8 900
2
3
4
M2
M3
M4
0.9
0.7
0.7
10
7
7
1500
1050
1050
2
3
4
6
M2
M3
M4
M6
1.3
0.9
0.9
0.7
15
10
10
7
1200
1200
1200
1200
4
10
14
M4
M10
M14
2
1.3
0.9
18
9
7
1500
1050
1050
2
3
4
6
8
10
M2
M3
M4
M6
M8
M10
1.6
1.6
1.3
1.3
0.9
0.9
20
15
15
12
9
7
1800
1500
1500
1500
750
750
00
0
1
2
3
Designation to use in the part-number system, page 20.
Contact
impedance
()
Desi-
gnation Ø Contact
Max
current
rating
(A)
Testing
voltage
(Vrms)
50 C50 0.7 5 1800
50
50S
C50
C50S
1.3
0.9
10
6
2300
2300
50
75
C50
C75
1.6
1.3
12
10
2300
2900
50
75
C50
C75
2
1.6
15
12
2900
3900
50
75
C50
C75
3
2
26
15
5700
6300
00
0
1
2
3
Shell
size Plug insulator viewed from wiring side Contact
layout Desi-
gnation Ø Contact
Max
current
rating
(A)
Testing
voltage
(Vrms)
Working
voltage
(Vdc / Vrms)
1 x Ø 1.3
2 x Ø 0.9 3 x Ø 0.7 4 x Ø 0.7
2 x Ø 1.3 3 x Ø 0.9 4 x Ø 0.9 6 x Ø 0.7
2 x Ø 1.6 3 x Ø 1.6
4 x Ø 2 10 x Ø 1.3 14 x Ø 0.9
4 x Ø 1.3 6 x Ø 1.3
8 x Ø 0.9 10 x Ø 0.9
pin contact
pin contact
pin contact
pin contact
pin contact
Insulator Working
voltage
(Vdc / Vrms)
Shell
size
800 / 600
1100 / 780
1100 / 780
1100 / 780
1400 / 980
1400 / 980
1800 / 1300
2800 / 1900
3000 / 2100
400 / 300
700 / 500
500 / 350
500 / 350
600 / 400
600 / 400
600 / 400
600 / 400
800 / 600
700 / 500
600 / 400
600 / 400
600 / 400
600 / 400
700 / 500
500 / 350
500 / 350
22
23
JAX Series
Suffix for cable outside diameter
Shell size Accomodation of cable diameter Obligatory suffix
00 From 1.5 mm to 2.2 mm
From 2 mm to 3.2 mm
D020
D030
0From 2 mm to 3.2 mm
From 3 mm to 4.2 mm
D030
D040
1
From 2 mm to 3.2 mm
From 3 mm to 4.2 mm
From 4 mm to 5.2 mm
From 5 mm to 6.2 mm
D030
D040
D050
D060
2
From 4 mm to 5.2 mm
From 5 mm to 6.2 mm
From 6 mm to 7.2 mm
From 7 mm to 8.2 mm
D050
D060
D070
D080
3
From 4 mm to 5.2 mm
From 5 mm to 6.2 mm
From 6 mm to 7.2 mm
From 7 mm to 8.2 mm
From 8 mm to 9.2 mm
From 9 mm to 10.2 mm
From 10 mm to 11.2 mm
D050
D060
D070
D080
D090
D100
D110
Designation to use in the part number system, page 20
Options
• Caps
Part number A B C D
JAX RA 120 12 11 20 70
JAX RA 220 15 11 21 70
JAX RA 320 18 14 26 70
Material: Nickel-chromium brass. Neoprene seal.
JAX Series
24
JAX Series
• Material and treatment
• Mechanical and climatics
Component Material Standard Surface treatment (µm)
ISO ASTM Cr Ni Au
Outer shell and collet nut Brass CuZn40Pb3 C38500 0.1 - 0.6 5 - 8 -
Latching sleeve Brass CuZn40Pb3 C38500 - 5 - 8 -
Shielding ring Brass CuZn40Pb3 C38500 - 3 - 7 -
Nut Brass CuZn40Pb3 C38500 5 - 8 -
Half bushes Brass CuZn40Pb3 C38500 - 5 - 8 -
Socket contact (1) Cupro-nickel CuNi1Pb1P - - 3 - 5 0.5
Pin contact (1) Brass CuZn35Pb2 C35300 - 3 - 5 0.5
Component Material Color Temperature withstanding
TEFZEL
(coaxial connector) White - 70°C ; + 150°C - 94°F ; + 302°F
Nylatron GS
(multipin connector) Grey - 40°C ; + 125°C - 40°F ; + 257°F
Characteristics Values Standard
Endurance 1000 cycles
Protection index IP 40 CEI 529
Operating temperature - 40°C ; + 125°C / - 40°F ; + 257°F
(1) Gold thickness as per MIL-G-45204C type 1, class 00.
Insert
Technical characteristics
25
JAX Camac Series
NIM-CAMAC* configuration (4 GHz - 50 )
Technical data
These 2 pages describe the JAX Camac series, size 00. These connectors are often used on jumpers for delay lines in Nuclear
Physics due to their size and simple handling in congested areas. For Nuclear Physics, our connectors meet the standard
NIM-CAMAC*. Moreover, JAX coaxial connectors are suitable for many other industrial and scientific applications such as
medical, microwave communications, pocket transmitters, input/output on electronic modules.
Dimensions and part-numbers
P/N : JAX F 00 C50 RG 174 US
Straight plug for RG174U cable
Weight : 3.5 g
P/N : JAX RA 00 C50S
Fixed front flange receptacle, solder contacts
Weight : 2.5 g
Ø2.1 min
P/N : JAX 00 MDPN
Protective boot
P/N : JAX RA 0018
RF screening cap
Weight : 0.2 g
Temperature = - 40°C ; + 80°C
Weight : 1.5 g
* NIM-CAMAC : Nuclear Instrumentation Module / Computer Automated Measurement and Control
9 on flats
L
Ø 8
Specific characteristics Values
Endurance 5000 cycles
Operating temperature - 70°C ; + 200°C
- 94°F ; + 392°F
Plating on metal shell Ni = 3 - 7 µm
Insert PTFE
Cable Ø =
min = 1
max = 3.8
JAX Series
26
JAX Camac Series
Delay lines
• Cable Nr 96-CEI-50-2-1 (RG 174U)
fitted with NIM-CAMAC connectors at both ends
P/N
JAX L 00 C50 C11 R005
JAX L 00 C50 C11 R010
JAX L 00 C50 C11 R020
JAX L 00 C50 C11 R030
JAX L 00 C50 C11 R040
JAX L 00 C50 C11 R050
JAX L 00 C50 C11 R060
JAX L 00 C50 C11 R080
JAX L 00 C50 C11 R100
JAX L 00 C50 C11 R160
Delay (ns)
0.5
1
2
3
4
5
6
8
10
16
Tolerance (%)
5
5
2.5
1.7
1.3
1
1
1
1
0.6
L *
100
200
400
600
800
1000
1200
1600
2000
3200
L : Length which defines delay in ns of cable jumpers
• Crimping tool
P/N : JX2W1010A9
* Average length, for information only
27
JAX Series
• Panel cutout
Size
A
B
00
7.1
6.4
0
9.1
8.3
1
12.1
10.6
2
15.1
13.6
3
18.1
16.6
Ø Contact
0.7
0.9
1.3
1.6
2.0
Usable cables (AWG)
26
24
20
18
16
Ø F
0.6
0.8
1.1
1.5
1.9
Size
0
1
2
3
A
9
12
17
19
B
4
4
4
4
C *
7
8
9
10
• Contacts
• Cable stripping for connectors with multi contacts (solder contacts)
• Cable stripping for connectors with coaxial contacts / single contacts
Wiring and assembly instructions
*
If shielded cable
Size
00
0
1
2
3
A
15
15.5
18.5
25
23
B
4
4.5
6.5
7
7.5
C
15
6
6
7
10
JAX Series
28
JAX Series
Wiring and assembly instructions :
MULTIPIN PLUGS SIZES 0, 1, 2, 3
1 - Slide the backnut and the collet onto the
cable.
2 - Terminate the bucket contacts using
solder method.
3 - For shielded cable : pull back the collet
up to external sheath extremity.
4 - Comb out the screen and fold back over
the collet end.
5 - Position two half bushes on the insert,
taking care of a proper positioning of the
key.
6 - Slide in the insert assembly into the
plug (or the free receptacle) shell.
Note : the collet key may be properly set
into shells key ways.
7 - Install the backnut and screw it.
• Connector preparation and contacts wiring
• Connector assembly
• Cable stripping : see page 27
JAX Series
Wiring and assembly instructions :
SINGLE PIN PLUGS
Wiring and assembly instructions :
COAXIAL PLUGS
• Connector assembly
1 - Slide the backnut and the collet onto the
cable.
2 - Position the intermediate cone in
abutment on external sheath extremity
3 - Brush back the screen around the cone
4 - Pull back the collet onto the cone
5 - Position the rear insulator sub-assembly
on the cone
8 - Slide in the insert assembly into the
plug (or free receptacle shells)
9 - Install the nut and screw it
6 - Solder inner core thru the pin window
7 - Set in place the front insulator, taking
care of the key/keyway positioning
between the two half insert sub-assembly
Note :
- Take care to align cone key inside the sub-assembly rear key way.
- The stripped core end may be visible inside pin contact front window.
Remark : For size 00, no cone existing : sub-assembly directly onto collet.
• Cable stripping :
see page 27
• Connector assembly
Monolythic insert is directly soldered onto the inner core.
• Cable stripping : see page 27
JAX Series
30
JAX Camac Series
Wiring and assembly instructions :
Crimp contact (NIM-CAMAC configuration)
• Wiring preparation
1 - Slide the protective boot and the
crimping ferrule onto the cable
• Coaxial cable stripping
1 - Strip the coaxial cable according to the
lengths given on the drawing
• Contact crimping
1 - Take the crimping tool P/N :
JX2 W 1010 A9
2 - Crimp the contact
• Connector assembly
1 - Position the crimp contact then engage
the insert cavity until it bottoms
2 - Fold the screen over the connector
outlet
3 - Position the ferrule on the screen then
crimp it
4 - Slide the protective boot and then
position on the connector outershell
Crimping
Crimping
31
JKX Series
• Sealed IP 68 (mated connectors)
Mechanically keyed : ensures correct polarization
and alignment.
• Contact arrangements : from 2 to 10 contacts.
• Wire gauge range from 28 AWG to 14 AWG.
• High contact density in a small space.
Contact termination in either crimp, solder or
PCB contacts.
Part number system
MS D SC
M05G1
FD
JKX
Basic series
Shell configuration FD - ER - EP - PC
Size 0 - 1
Keying G
Contact layouts 02 ---------- 10 (see page 33)
Contact type M: pin F: socket (in relation with keying)
Contact termination C: crimp ; S: solder ; P* : straight PCB tails ; Q* : 90° PCB tails ; W: 0.7 mm clipped
solder
Material & surface plating S: Outer shell in brass alloy with glossy chrome over nickel
N: Outer shell in brass alloy with black plating (consult us)
D: Obligatory suffix
S: Insulator in PPS
P: Insulator in Peek (for Ø 0.5 mm contacts only)
Obligatory suffix for layouts including contacts of Ø 0.5 mm
Options M: Connector with backnut for protective boot (protective boot to order separately page 34)
G: Connector adapted to accomodate larger cables (Ø 4.5 to 6 in size 0 and Ø 6 to 8 in size 1)
R: Red dot (possible for FD, PC, ER only)
* For receptacles with female contacts only.
Key features
User advantages
Temporary immersion IP 68
6-collet cluster
Allows a wide range of cable diameter
applications for a single connector.
Reduces inventory variations.
Removable contacts
Crimp versions allow easier wiring and
maintenance.
JKX Series
32
JKX Series
Shell type
Available JKX shells
• Dimensions
FD : Straight plug with cable clamping
Size
0
1
A
47
57
Ø B
12
15
Ø M
1.5 to 4.5
2 to 6
ER : Fixed receptacle, front panel mounting
Size
0
1
A
19.5
24.5
B
4.5
8.5
C
4
4.5
Ø D
18
20
EP : Fixed receptacle, back panel mounting
Size
0
1
A
19.5
24.5
B
4.5
6
C
3.2
4
Ø D
18
20
PC : Cable mounted receptacle
• Option G : to accomodate bigger cables Size
0
1
A
51
60
ØB
12
15
Ø M
4.6 to 6
6 to 8
Size
0
1
A
_
60
Ø B
_
16
Ø C
_
2 to 6
JKX Series
Keying
Contacts
• Multi contacts inserts
G keying is available in standard version (0°
keying angle, plugs with pin contacts,
receptacles with female contacts) for the 4
shell types. Reverse gender available in all
layouts.
Shell size Key ER EP PC FD
0G●●_
1G●●●●
Concerning the availability of other alternatives, please consult our commercial office.
Male AWG Max. Testing Working
Shell insulator Contact S C P* Q* ØSolder Crimp current voltage voltage
size viewed from layout solder crimp straight 90° Contact wire wire rating (Vdc /
wiring side PCB tails PCB tails Max. Max. (A) (Vrms) Vrms)
02 S C P Q 0.9 24 20 10 1400 660/460
03 S C P Q 0.9 24 20 8 1300 600/420
04 S C P Q 0.7 26 22 7 1400 660/460
05 S C P Q 0.7 26 22 6.5 800 400/260
06 S P 0.5 28 - 2.5 680 320/220
07 S P 0.5 28 - 2.5 680 320/220
02 S C P 1.3 20 18 15 1600 760/530
03 S C P Q 1.3 20 18 12 1300 600/420
04 S C P Q 0.9 24 20 10 1900 900/630
05 S C P Q 0.9 24 20 9 1400 660/460
06 S C P Q 0.7 26 22 7 1400 660/460
07 S C P Q 0.7 26 22 7 1400 660/460
08 S C P Q 0.7 26 22 5 1200 600/420
10 S P 0.5 28 - 2.5 600 300/200
Inserts with fixed contacts (non removable contacts) * For receptacles with female contacts only
Available Contact types
0
1
JKX Series
34
JKX Series
Options
• Protective boot
Protective boot can accept multiple cable diameters
• Caps : an efficient protection until 2 bars
With each JKX connector, one protective boot can accept diverse cable diameters thus the end-user can manage various cable
diameters without bothering with multiple part numbers.
Material :
ELASTOLLAN (PUR)
Working temperature :
- 40°C ; + 80°C
- 40°F ; + 176°F
Dimensions
Part Shell Shell size
number size Option Ø AL Ø Câble
Gmin Max.
JBX 0 MP* 0 - 2.2 20 1.5 5.5
JBX 1 MP* 1 0 2.6 25 2 7.5
JBX 2 MP* - 1 4 30 3.5 9.7
Color code Colors
A blue
B white
G grey
J yellow
M brown
N black
R red
V green
O orange
* Color code
Part number Ø
JKX BR0 15
JKX BR1 17
35
JKX Series
Technical characteristics
• Material and treatment
• Mechanical and climatics
Component Material Standard Surface treatment (µm)
ISO ASTM Cr Ni Au
Outer shell and collet nut Brass CuZn40Pb3 C38500/C360 0.1 - 0.6 5 - 8 -
Latching sleeve & metal collet Brass CuZn40Pb3 C38500/C360 - 5 - 8 -
Shielding ring Brass CuZn40Pb3 C38500/C360 - 3 - 7 -
Nut Brass CuZn40Pb3 C38500/C360 5 - 8 -
Tapered washer and half bushes Brass CuZn40Pb3 C38500/C360 - 5 - 8 -
Socket contact (1) Copper-nickel CuNi1Pb1P CDA C 19150 - 3 - 5 0.5
Pin contact (1) Brass CuZn35Pb2 C35300/C360 - 3 - 5 0.5
Clip Beryllium copper CuBe1,9 C17200/C360 - - -
Component Material Color Temperature withstanding
Insert PPS + 40%GF black - 65°C + 200°C - 85°F + 392°F
or PEEK + 15%GF brown - 50°C + 250°C - 58°F + 482°F
Plastic collet PA 6/6 + MoS2 black - 55°C + 125°C - 67°F + 257°F
Cable seal Silicon rubber red - 50°C + 250°C - 58°F + 482°F
Characteristics Values Standard Method
Endurance > 1000 cycles (except for 0.7 mm crimp contacts for which MIL-STD 2016.1
endurance is limited to 500 cycles) 1344A
Shock 50 g, duration 6 ms ; contact Ø0.7 mm and 0.9 mm MIL-STD 2004.1
100 g, duration 6 ms ; contact Ø1.3 mm - 1.6 mm and 2 mm 1344A
Vibrations 10 to 2000 Hz γ= 15 g, contact Ø0.7 mm and 0.9 mm MIL-STD 2005.1
γ= 20 g, contact Ø1.3 mm - 1.6 mm and 2 mm 1344A
Protection index IP 68 (watertight - 48 hours under 1 m of water) CEI 529
- 55°C + 125°C
with plastic collets - 67°F + 257°F --
Operating temperature
with optional metal collets - 55°C + 200°C
- 67°F + 392°F - -
(1) Gold thickness as per MIL-G-45204C type 1, class 00.
}
}
JKX Series
JKX Series
Wiring and assembly instructions
• Panel cutout
• Removable contacts
Crimp contacts
Solder contacts
Contact Usable cables Max. Contact Endurance
Core section (mm
2
)current resistance (number
Ø CØ F AWG rating (A) (m) of cycles)
min Max.
0.7 0.85 0.129 0.326
22 - 24 - 26
7 5 500 Max.
0.9 1.1 0.205 0.518
20 - 22 - 24
10 3.5 > 1000
1.3 1.4 0.326 0.823
18 - 20 - 22
15 3 > 1000
Contact Usable cables Max. Contact Endurance
Core section (mm
2
)current resistance (number
Ø CØ F AWG rating (A) (m) of cycles)
min Max.
0.9 0.8
-
0.21 24 10 3.5 > 1000
1.3 1.1
-
0.60 20 15 3 > 1000
The conductor bucket on the solder contacts is designed with an angle to form a cup into which the solder can flow easily.
• Fixed contacts
Solder contacts
Contact Usable cables Max. Contact Endurance
Shell
Core section
current resistance (number
Ø
C
Ø
F size
(mm2) Max.
AWG rating (A) (m
) of cycles)
0.5 0.5 0 - 1 0.096 28 5 10 > 1000
0.7 0.63 0 - 1 0.15 26 7 5 > 1000
Contacts for PCB
Size 0 1
Ø A 14.1 16.1
B12.6 14.6
Contacts for PCB Contact length dimensions “L”
PCB tail length size 0 dimension “L” 5.5 mm
0.7 mm female PCB tail length size 0 dimension “L” 3.5 mm
0.7 mm female PCB tail length size 1 dimension “L” 4.0 mm
0.9 mm female PCB tail length size 0 dimension “L” 3.5 mm
0.9 mm female PCB tail length size 1 dimension “L” 4.0 mm
1.3 mm female PCB tail length size 1 dimension “L” 4.0 mm, dimension “F” 0.7 mm
B
A
+0.2
–0
ø+0.3
+0.1
0.7 1.0
-
0.3 22 7 5 500 Max.
36
37
JKX Series
1.35
> 1.35
1.6
> 1.6
1.35
> 1.35
1.6
> 1.6
2.1
> 2.1
Wiring and assembly instructions
• Cable stripping for connectors with crimp contacts
• Cable stripping for connectors with solder contacts
Stripping for FD / PC
LCT
0.7 15 7
0.9 15 7
0.7 17 8
10.9 17 8
1.3 17 8
Shell size Ø Contacts Ø I
Shell size Ø Contacts
0
1
0
4
5.5
4
5.5
4
5.5
4
5.5
4
5.5
Stripping for FD / PC
LST
0.5 11 2 7
0.7 12 3 7
0.9 12 3 7
0.5 13 2 8
0.7 14 3 8
0.9 14 3 8
1.3 14 3.5 8
ØI : diameter over insulation
:O’ring for sealing between receptacle and plug shell
:O’ring for sealing between receptacle and panel
:O’ring for sealing between plug body and backshell
:seals to accomodate variety of cable diameters
Fixed receptacle Straight plug
• Watertightness design (mated connectors)
JKX Series
38
JKX Series
• Connector preparation
1 - Select the proper collet and the cable
seal (see page 39).
2 - Slide protective boot , the backnut , the
collet , the cable seal , the outershell
and the taper seat onto the cable.
Strip end
of cable (see pg. 16)
• Contacts wiring : crimp contacts
1 - Select the proper crimping tool (see page 48)
2 - Adjust the crimping tool based on the wire
size “AWG”. (See wire size and crimp tool
settings on the back of this locator.)
3 - Crimp the contacts then insert the contact
into the insulator until the clip is fully seated
and cannot be removed.
• Contacts wiring : solder contacts
Fixed solder contacts 0.5 mm and 0.7 mm Removable solder contacts from 0.9 mm to 1.3 mm
1 - Insert wire into solder cup and solder 1 - Insert wire into solder cup and solder
2 - Insert the contact into the insulator until the clip is fully seated and cannot be removed.
• Connector assembly
1 - In case of shielded cable, comb out the shield
and fold back over the tapper seat
.
2 - Position 2 half bushes
, making sure that the
insert key appears through the windows of one
bush.
3 - Position the taper seat
on the half bushes
.
4 - Position all the sub-assembly in connector
housing
, making sure to keep the sub-
assembly well aligned.
5 - Screw the outershell
following the torque
values on page 39. Install the cable seal
and
the collet
into the outershell
then screw
the backnut
till bottoming. Use 2 wrenches
well positionned on the flats A and B. Place a
wrench to grip flats B, use the other wrench to
tighten the backnut at the flats A following the
torque values on page 39.
6 - Install the protective boot
if applicable.
Wiring and assembly
instructions :
STRAIGHT PLUG
• Cable stripping : see page 37
39
JKX Series
• Collets selection according to cable diameters
3 or 5 collets per shell size allow a wide range of cable diameters for a single connector. Cable out diameters are for information
only, since values will change with each cable construction.
Cable diameter
Shell size 0 Size 0, option G Shell size 1 Size 1, option G
1 1.5 - 2.5 - 2- 2.5 -
22.6 - 3.5 - 2.6 - 3.5 -
33.6 - 4.5 - 3.6 - 4.5 6.1 - 6.7
4-4.6 - 5.5 4.6 - 5.5 6.8 - 7.7
5- 5.6 - 65.6 - 67.8 - 8
Collet number 4 in shell size 0 and collet number 6 in shell size 1 are not used.
Discreet application based on cable diameter
• Cable seal selections according to cable size
Collet number
Cable diameter
Shell size 0 Size 0, option G Shell size 1 Size 1, option G
21.5 - 2.9
3.5 3 - 4.5
2.5 2 - 3.4 -
44.6 - 4.9 3.5 - 4.9 -
5.5 5 - 6 5 - 6 6.1 - 6.4
76.5 - 8
Cable gland
Ø A
2
4
3
5
6
1
Advised torque* in Nm
00
(option G) 11
(option G)
1.6 / 1.8 /
1.5 2.5
0.8 1
22
0.8 1
Size
mm
14 x 1 16 x 1
00
(option G) 11
(option G)
17
813
10 11 12 14
19
10
Size
Tools
(jaw dimensions)
Wiring and assembly instructions
• Coupling torques Tool dimensions
Torque values are the maximum allowable for each connector size.
Torque values will vary due to the type and size of the cable used
*Apply thread lock to back nut prior to assembly.
Tool numbers can be found on page 32
• Shielding
Tested according to MIL-STD 1344 A, method 3007
Shell size
04
13
G
A
mV
Ø A
Electrical
continuity (m)
JKX Series
40
JBX Series
sealed version size 2
Key features
Sealed IP 67 (mated connectors)(FE, EC, SE, & PC)
Watertight receptacles IP68 (HC & HH)
• Mechanically keyed : ensure correct polarisation and
alignment.
• Contact arrangements : from 2 to 19 contacts.
• Wire gauge range from 26 AWG to 12 AWG.
• High contact density in a small space.
Contact termination in either crimp, solder or PCB
contacts.
Part number system
RS D SC
M12G2
FE
JBX
Basic series
Shell type FE-HH-HC-EC-PE-SE
Shell size 2
Keying G
Contact layouts 02 ---------- 19
Contact type M: pin F: socket (in relation with keying)
Contact termination C: crimp ; S: solder ; P* : straight PCB tails ; Q* : 90° PCB tails
Material & surface plating S: Outer shell in brass alloy with chrome over nickel
N: Outer shell in brass alloy with black plating (consult us)
D: Obligatory suffix
S: Obligatory suffix
Option R: FE, PE, HH, & HC N/A for EC & SE
* For receptacles with female contacts only.
User advantages
Wet environment IP67
6-collet cluster
Allows a wide range of cable diameter
applications for a single connector.
Reduces inventory variations.
Removable contacts
(EC, FE, SE & PE)
Crimp versions allow easier wiring and
maintenance.
41
JBX Series
sealed version size 2
Shell type
• Available sealed JBX, Size 2
• Dimensions
FE : Straight plug supplied with protective
boot, sealed mated IP67. EC : Double nut receptacle. Sealed mated
IP67 not sealed unmated. HC : Fixed receptacle, back panel
mount. Sealed unmated IP68, not
available in crimp, 4-position minimum.
SE : Cable clamp receptacle, sealed
mated IP67, supplied with protective
boot.
PE : Cable mounted supplied with
protective boot sealed mated IP67.
JBX Series
EC : Double nut receptacle
FE : Straight plug with cable clamping
PE : Cable mounted receptacle
SE : Fixed receptacle with cable clamping
HC : Fixed receptacle, back panel mounting
42
JBX Series
sealed version size 2
Keying
Only G keying is available in standard version (0° keying angle, plugs with pin contacts, receptacles with female contacts) for
the different types of shells.
Contact layouts
• Multi contact inserts
Male AWG Max. Testing Working
Shell insulator Contact S C P* Q* ØSolder Crimp current voltage voltage
size viewed from layout solder crimp straight 90° Contact wire wire rating (Vdc /
wiring side PCB tails PCB tails Max. Max. (A)* (Vrms)* Vrms)*
02 S C 2 16 12 30 2100 1000/700
03 S C 1.6 18 14 17 1700 830/560
04 S C P Q 1.3 20 18 15 2400 1000/800
05 S C P Q 1.3 20 18 14 1900 900/630
06 S C P Q 1.3 20 18 12 1900 900/630
07 S C P Q 1.3 20 18 11 1500 730/500
08 S C P Q 0.9 24 20 10 1700 830/560
10 S C P Q 0.9 24 20 8 1700 830/560
12 S C P Q 0.7 26 22 7 1700 830/560
16 S C P Q 0.7 26 22 6 1500 730/500
18 S C P 0.7 26 22 5.5 1400 660/460
19 S C P 0.7 26 22 5 1400 660/460
Inserts with fixed contacts (non removable contacts).
* For EC and HC receptacles with female contacts only.
HH & HC fixed contacts only.
Available Contact types
2
JBX Series
sealed version size 2
Technical characteristics
The technical characteristics are the same as for the standard JBX series except the following ones:
• Material - Specific additionnal elements
Component Material Color Working temperature
Seals Nitrile
O’ring seal = black
- 30°C ; + 250°C - 58°F ; + 482°F
Protective boot Elastollan (PUR) Black - 40°C ; + 80°C - 40°F ; + 176°F
Characteristics Values
Protection index IP 67 (Splashproof - 1/2 hour under 1 m of water)
Operating temperature - 40°C ; + 80°C - 40°F ; + 176°F
• Mechanical and climatics - Specific additional elements
Options • Cap: Part-number = JBX BR2 022 : an efficient
protection against water
Wiring and assembly instructions
• Panel cutout
The panel cutout is the same as for the JBX size 2 shells except for the HC.
• Operation to add during the plug assembly:
Deposit of watertight thread glue between the backnut (on the drawing p17) and the connection shell (on the drawing p17).
Advised glue = Loctite 542.
Sealed JBX
• Sealed Panel cutout
43
44
Push-Pull connectors
Accessories JAX - JBX
• Insulating washer
Part Shell
number size ØA B L M N T E
JBX 00 RIN 00 10 8.8 1.8 1 0.8 8 4.4
JBX 0 RI* 0 12 10.8 1.8 1 0.8 9.9 6.4
JBX 1 RI* 1 16 13.8 1.8 1 0.8 12.2 8.4
JBX 2 RI* 2 21 17.8 2.2 1.2 0.8 16.2 8.2
JBX 3 RI* 3 25 21.8 2.2 1.2 0.8 20.2 10.1
* Washer colors as protective boots.
In size 00, available only in black.
Material : PA 6/6
Working temperature : - 40°C ; + 125°C
- 40°F ; + 257°F
Using 2 washers for receptacle / panel insulating
2 washers
Nut
Receptacle
• Grounding washer
Material : - Brass
- Nickel plated (3 µm)
Part Shell Dimensions
number size ØAØBL N
JAX RA 00 251 00 10 7.2 0.3 21.5
JAX RA 0 251 0 13 9.1 0.3 24
JAX RA 1 251 1 16 12.2 0.3 24
JAX RA 2 251 2 21 15.1 0.8 35
JAX RA 3 251 3 25 18.1 0.8 37
Ø A
Ø B L
N
Be careful : usable for the JAX and JBX series but not for sealed connectors (JKX and sealed JBX size 2).
Be careful : usable for the JAX and JBX series but not for sealed connectors (JKX and sealed JBX size 2).
45
Push-Pull connectors
Piece parts JBX-JKX
• Crimp contacts (if ordered separately)
Accessories JAX-JBX
• Locking washer
Part Number
Shell size Øcontact Crimp pin Crimp socket
0
1
2
3
0.9 JBX 0 CT MC 09 JBX 0 CT FC 09
0.7 JBX 0 CT MC 07 JBX 0 CT FC 07
1.3 JBX 1 CT MC 13 JBX 1 CT FC 13
0.9 JBX 1 CT MC 09 JBX 1 CT FC 09
0.7 JBX 1 CT MC 07 JBX 1 CT FC 07
2 JBX 2 CT MC 20 JBX 2 CT FC 20
1.6 JBX 2 CT MC 16 JBX 2 CT FC 16
1.3 JBX 2 CT MC 13 JBX 2 CT FC 13
0.9 JBX 2 CT MC 09 JBX 2 CT FC 09
0.7 JBX 2 CT MC 07 JBX 2 CT FC 07
2 JBX 3 CT MC 20 JBX 3 CT FC 20
1.6 JBX 3 CT MC 16 JBX 3 CT FC 16
1.3 JBX 3 CT MC 13 JBX 3 CT FC 13
0.9 JBX 3 CT MC 09 JBX 3 CT FC 09
0.7 JBX 3 CT MC 07 JBX 3 CT FC 07
• Solder contacts (if ordered separately)
Part Number
Shell size Øcontact Solder pin Solder socket
0
1
2
3
0.9 JBX 0 CT MS 09 JBX 0 CT FS 09
1.3 JBX 1 CT MS 13 JBX 1 CT FS 13
0.9 JBX 1 CT MS 09 JBX 1 CT FS 09
2 JBX 2 CT MS 20 JBX 2 CT FS 20
1.6 JBX 2 CT MS 16 JBX 2 CT FS 16
1.3 JBX 2 CT MS 13 JBX 2 CT FS 13
0.9 JBX 2 CT MS 09 JBX 2 CT FS 09
2 JBX 3 CT MS 20 JBX 3 CT FS 20
1.6 JBX 3 CT MS 16 JBX 3 CT FS 16
1.3 JBX 3 CT MS 13 JBX 3 CT FS 13
0.9 JBX 3 CT MS 09 JBX 3 CT FS 09
Solder contacts of 0.5 mm and 0.7 mm diameter not available separately
(always fixed into the insulator).
Part Shell Dimensions
number size ØAØBC D
JAX RE 0 0 9.2 12.5 0.6 1
JAX RE 1 1 12.2 16 0.6 1
JBX RE 2 2 16 19.8 0.6 1
46
Push-Pull connectors
Piece parts JBX-JKX
• Inserts for removable solder and crimp contacts (if ordered separately)
Insert Part Number
Shell size Insert Pin contacts Socket contacts
0
1
2
3
02 JBX 0 BI 02 MS JBX 0 BI 02 FS
03 JBX 0 BI 03 MS JBX 0 BI 03 FS
04 JBX 0 BI 04 MS JBX 0 BI 04 FS
05 JBX 0 BI 05 MS JBX 0 BI 05 FS
02 JBX 1 BI 02 MS JBX 1 BI 02 FS
03 JBX 1 BI 03 MS JBX 1 BI 03 FS
04 JBX 1 BI 04 MS JBX 1 BI 04 FS
05 JBX 1 BI 05 MS JBX 1 BI 05 FS
06 JBX 1 BI 06 MS JBX 1 BI 06 FS
07 JBX 1 BI 07 MS JBX 1 BI 07 FS
08 JBX 1 BI 08 MS JBX 1 BI 08 FS
02 JBX 2 BI 02 MS JBX 2 BI 02 FS
03 JBX 2 BI 03 MS JBX 2 BI 03 FS
04 JBX 2 BI 04 MS JBX 2 BI 04 FS
05 JBX 2 BI 05 MS JBX 2 BI 05 FS
06 JBX 2 BI 06 MS JBX 2 BI 06 FS
07 JBX 2 BI 07 MS JBX 2 BI 07 FS
08 JBX 2 BI 08 MS JBX 2 BI 08 FS
10 JBX 2 BI 10 MS JBX 2 BI 10 FS
12 JBX 2 BI 12 MS JBX 2 BI 12 FS
16 JBX 2 BI 16 MS JBX 2 BI 16 FS
18 JBX 2 BI 18 MS JBX 2 BI 18 FS
19 JBX 2 BI 19 MS JBX 2 BI 19 FS
03 JBX 3 BI 03 MS JBX 3 BI 03 FS
04 JBX 3 BI 04 MS JBX 3 BI 04 FS
07 JBX 3 BI 07 MS JBX 3 BI 07 FS
10 JBX 3 BI 10 MS JBX 3 BI 10 FS
14 JBX 3 BI 14 MS JBX 3 BI 14 FS
18 JBX 3 BI 18 MS JBX 3 BI 18 FS
22 JBX 3 BI 22 MS JBX 3 BI 22 FS
30 JBX 3 BI 30 MS JBX 3 BI 30 FS
Insert for pin contacts
Insert for socket contacts
47
Push-Pull connectors
• Inserts with fixed solder contacts (if ordered separately)
Insert Part Number
Shell size Insert Pin contacts Socket contacts
00
0
1
2
3
04 JBX 00 BI 04 MPS JBX 00 BI 04 FPS
04 JBX 0 BI 04 MSS JBX 0 BI 04 FSS
05 JBX 0 BI 05 MSS JBX 0 BI 05 FSS
06 JBX 0 BI 06 MPS JBX 0 BI 06 FPS
07 JBX 0 BI 07 MPS JBX 0 BI 07 FPS
07 JBX 1 BI 07 MSS JBX 1 BI 07 FSS
08 JBX 1 BI 08 MSS JBX 1 BI 08 FSS
10 JBX 1 BI 10 MPS JBX 1 BI 10 FPS
12 JBX 2 BI 12 MSS JBX 2 BI 12 FSS
16 JBX 2 BI 16 MSS JBX 2 BI 16 FSS
18 JBX 2 BI 18 MSS JBX 2 BI 18 FSS
19 JBX 2 BI 19 MSS JBX 2 BI 19 FSS
22 JBX 3 BI 22 MSS JBX 3 BI 22 FSS
30 JBX 3 BI 30 MSS JBX 3 BI 30 FSS
Insert for pin contacts
Insert for socket contacts
Toolings JBX - JKX
• Manual extraction tools
Contacts automatically extracted
The extraction tool is similar for both male and female contacts.
Shell size Ø Contacts
SOURIAU Part number
ASTRO Part number
0.7 JBX OUT DC 07 ATJP 2045
0.9 JBX OUT DC 09 AT
JP
2057
0.7 JBX OUT DC 07 AT
JP
2045
0.9 JBX OUT DC 09 AT
JP
2057
1.3 JBX OUT DC 13 AT
JP
2077
0.7 JBX OUT DC 07 AT
JP
2045
0.9 JBX OUT DC 09 AT
JP
2057
1.3 JBX OUT DC 13 AT
JP
2077
1.6 JBX OUT DC 16 AT
JP
2095
2.0 JBX OUT DC 20 AT
JP
2115
0.7 JBX OUT DC 07 AT
JP
2045
0.9 JBX OUT DC 09 AT
JP
2057
1.3 JBX OUT DC 13 AT
JP
2077
1.6 JBX OUT DC 16 AT
JP
2095
2.0 JBX OUT DC 20 AT
JP
2115
0
1
2
3
The contact is automatically extracted without the need of pulling onto the cable.
48
Push-Pull connectors
Toolings JBX - JKX
• Turret with locator for pin and socket 1.6 mm and 2 mm contacts
• Crimping tool
Male contact Female contact
SOURIAU P/N DANIELS P/N ASTRO P/N SOURIAU P/N DANIELS P/N ASTRO P/N
0.7 22 - 24 - 26 JBX 0 OUT LP07 86 - 223 / JBX 0 OUT LS07 86 - 224 /
0.9 20 - 22 - 24 JBX 0 OUT LP09 86 - 225 / JBX 0 OUT LS09 86 - 226 /
0.7 22 - 24 - 26 JBX 1 OUT LP07 86 - 196 642 - 001 JBX 1 OUT LS07 86 - 197 642 - 004
0.9 20 - 22 - 24 JBX 1 OUT LP09 86 - 198 642 - 002 JBX 1 OUT LS09 86 - 199 642 - 005
1.3 18 - 20 - 22 JBX 1 OUT LP13 86 - 200 642 - 003 JBX 1 OUT LS13 86 - 201 642 - 006
0.7 22 - 24 - 26 JBX 2 OUT LP07 86 - 202 642 - 007 JBX 2 OUT LS07 86 - 203 642 - 010
0.9 20 - 22 - 24 JBX 2 OUT LP09 86 - 204 642 - 008 JBX 2 OUT LS09 86 - 205 642 - 011
1.3 18 - 20 - 22 JBX 2 OUT LP13 86 - 206 642 - 009 JBX 2 OUT LS13 86 - 207 642 - 012
0.7 22 - 24 - 26 JBX 3 OUT LP07 86 - 217 642 - 014 JBX 3 OUT LS07 86 - 214 642 - 017
0.9 20 - 22 - 24 JBX 3 OUT LP09 86 - 218 642 - 015 JBX 3 OUT LS09 86 - 215 642 - 018
1.3 18 - 20 - 22 JBX 3 OUT LP13 86 - 219 642 - 016 JBX 3 OUT LS13 86 - 216 642 - 019
Shell size Ø contacts AWG
0
1
Male and female contacts
SOURIAU P/N DANIELS P/N ASTRO P/N
1.6 14 - 16 - 18 JBX 2 OUT LT16 TH 564 650 - 030
2 12 - 14 - 16 JBX 2 OUT LT20 TH 565 650 - 031
1.6 14 - 16 - 18 JBX 3 OUT LT16 TH 566 650 - 038
2 12 - 14 - 16 JBX 3 OUT LT20 TH 567 650 - 035
Shell size Ø contacts AWG
2
3
2
3
Specifications MIL-C-22520 / 7.01
Specifications MIL-C-22520 / 1.01
MIL P/N - SOURIAU P/N Supplier P/N
Contacts 0.7 mm - 0.9 mm MIL-22520/7-01 Daniels : MH860
and 1.3 mm Buchanan : 616 336
MIL P/N - SOURIAU P/N Supplier P/N
Contacts 1.6 mm MIL-22520/1-01 Daniels : AF8
and 2 mm Buchanan : 615 708
• Locator for pin and socket 0.7 - 0.9 mm and 1.3 mm contacts
49
More about our know-how
Examples of custom designs derivated from standard connectors lines
• Watertight receptacles
• Black finish plating
• JBX series:
Custom watertight receptacles designed to customer requirements
• JBX and JKX series, black chrome plating
Applications: Military radiocommunication
Push-Pull connectors
Request form please fill in and fax to SOURIAU - Customer service
(see the address page for your local contact)
Name : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel number : . . . . . . . . . . . . . . . . Fax number : . . . . . . . . . . .
Title : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-mail : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Company : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Address : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Applications :
Medical Audio Video Instrumentation Nuclear physics
GPS Transportation Metrology Other .............................................................
Detailed description of end product, unit or application ……………………………………………………………………………
Connector description :
Series :. . . . . . . . . . . . . . . . . . . . . . . . . Shell configuration : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shell size : . . . . . . . . . . . . . . . . . . . . . Protective boot : . . . . . . . . . . . . . . . . . . . . . Color : . . . . . . . . . . . . . . .
Number of contacts : . . . . . . . . . . . . . .
Type of contacts : Solder. . . . . . . . . . Crimp . . . . . Printed circuit . . . . . . . . . . 90° printed circuit
Conductor AWG : . . . . . . . . . . . . . . . . . Coax type : . . . . . . . . . . . . . . . . . . . . . . . . Other : . . . . . . . . . . . . . .
Electrical :
Working voltage (AC/DC) : . . . . . . . . . . . Current rating : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Impedance (Ohms) : . . . . . . . . . . . . . . . SWR : . . . . . . . . . . . . . . . . . . . . . . .Frequency . . . . . . . . . . . . . . . . .
Contact resistance : . . . . . . . . . . . . . . . . Shielding : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fibre optics : Multimode . . . . . . . . . . . . . . . . . . . . . . . Monomode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Environment :
Temperature : . . . . . . . . . . . . . . . . . . . . Protection index (IP -- ) : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outside environment :
Clear . . . . . . . . . . . . . . . Splash proof . . . . . . . . . . . . . . . . . . .Sterilization . . . . . . . . . . . . . . . .
Dirt . . . . . . . . . . . . . . . . Fluids . . . . . . . . . . . . . . . . . . . . . . . .Radiation . . . . . . . . . . . . . . . . . .
Chemicals . . . . . . . . . . . Waterproof . . . . . . . . . . . . . . . . . . . .Gases . . . . . . . . . . . . . . . . . . . .
Salt waterspray . . . . . . .
Projections :
Prototype quantity : . . . . . . . . . . . . . . . . . . . . . . . . . . . . Delivery date : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preseries quantity : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Delivery date : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Production quantity : . . . . . . . . . . . . . . . . . . . . . . . . . . . . Delivery date : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Production per year : . . . . . . . . . . . . . . . . . . . . . . . . . . . Number of years : . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Target pricing per connector : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Push-Pull connectors
Conversion Table
• Millimeters / Inches • °C/°F
(mm) (inches)
0.1 0.00394
0.2 0.00788
0.3 0.01182
0.4 0.01576
0.5 0.01970
0.6 0.02364
0.7 0.02758
0.8 0.03152
0.9 0.03546
1.0 0.03940
1.1 0.04334
1.2 0.04728
1.3 0.05122
1.4 0.05516
1.5 0.05910
1.6 0.06304
1.7 0.06698
1.8 0.07092
1.9 0.07486
2.0 0.07880
2.1 0.08274
2.2 0.08668
2.3 0.09062
2.4 0.09456
2.5 0.09850
2.6 0.10244
2.7 0.10638
2.8 0.11032
2.9 0.11426
3.0 0.11820
3.1 0.12214
3.2 0.12608
3.3 0.13002
3.4 0.13396
3.5 0.13790
3.6 0.14184
3.7 0.14578
3.8 0.14972
3.9 0.15366
4.0 0.15760
4.1 0.16154
4.2 0.16548
4.3 0.16942
4.4 0.17336
4.5 0.17730
4.6 0.18124
4.7 0.18518
4.8 0.18912
4.9 0.19306
5.0 0.19700
5.2 0.20488
5.4 0.21276
5.6 0.22064
5.8 0.22852
6.0 0.23640
6.2 0.24428
6.4 0.25216
6.6 0.26004
6.8 0.26792
7.0 0.27580
7.2 0.28368
7.4 0.29156
7.6 0.29944
7.8 0.30732
8.0 0.31520
(mm) (inches)
8.2 0.32308
8.4 0.33096
8.6 0.33884
8.8 0.34672
9.0 0.35460
9.2 0.36248
9.4 0.37036
9.6 0.37824
9.8 0.38612
10.0 0.39400
10.5 0.41370
11.0 0.43340
11.5 0.45310
12.0 0.47280
12.5 0.49250
13.0 0.51220
13.5 0.53190
14.0 0.55160
14.5 0.57130
15.0 0.59100
15.5 0.61070
16.0 0.63040
16.5 0.65010
17.0 0.66980
17.5 0.68950
18.0 0.70920
18.5 0.72890
19.0 0.74860
19.5 0.76830
20.0 0.78800
20.5 0.80770
21.0 0.82740
21.5 0.84710
22.0 0.86680
22.5 0.88650
23.0 0.90620
23.5 0.92590
24.0 0.94560
24.5 0.96530
25.0 0.98500
25.5 1.00470
26.0 1.02440
26.5 1.04410
27.0 1.06380
27.5 1.08350
28.0 1.10320
28.5 1.12290
29.0 1.14260
29.5 1.16230
30.0 1.18200
30.5 1.20170
31.0 1.22140
31.5 1.24110
32.0 1.26080
32.5 1.28050
33.0 1.30020
33.5 1.31990
34.0 1.33960
34.5 1.35930
35.0 1.37900
35.5 1.39870
36.0 1.41840
36.5 1.43810
37.0 1.45780
37.5 1.47750
(mm) (inches)
38.0 1.49720
38.5 1.51690
39.0 1.53660
39.5 1.55630
40.0 1.57600
40.5 1.59570
41.0 1.61540
41.5 1.63510
42.0 1.65480
42.5 1.67450
43.0 1.69420
43.5 1.71390
44.0 1.73360
44.5 1.75330
45.0 1.77300
45.5 1.79270
46.0 1.81240
46.5 1.83210
47.0 1.85180
47.5 1.87150
48.0 1.89120
48.5 1.91090
49.0 1.93060
49.5 1.95030
50.0 1.97000
51.0 2.00940
52.0 2.04880
53.0 2.08820
54.0 2.12760
55.0 2.16700
56.0 2.20640
57.0 2.24580
58.0 2.28520
59.0 2.32460
60.0 2.36400
61.0 2.40340
62.0 2.44280
63.0 2.48220
64.0 2.52160
65.0 2.56100
66.0 2.60040
67.0 2.63980
68.0 2.67920
69.0 2.71860
70.0 2.75800
71.0 2.79740
72.0 2.83680
73.0 2.87620
74.0 2.91560
75.0 2.95500
80.0 3.15200
85.0 3.34900
90.0 3.54600
100.0 3.94000
200.0 7.88000
400.0 15.76000
600.0 23.64000
800.0 31.52000
1000.0 39.40000
1200.0 47.28000
1600.0 63.04000
2000.0 78.80000
3200.0 126.08000
(°C) (°F)
- 70 - 94
- 65 - 85
- 55 - 67
- 50 - 58
- 40 - 40
032
37 98.6
80 176
125 257
150 302
170 338
200 392
250 482
• Pressure conversion
bar psi mmHg (torr)
10 145.0 7600
5 72.5 3800
2 29.0 1520
1 14.5 760
0.5 7.2 380
0.1 1.4 76
mbar psi torr (mmHg)
100 1.4 76
50 0.72 38
10 0.14 7.6
1.32 0.019 1