Performance Features:
IP67 certied sealed front panel components
Withstands temperatures from -40°C to +85°C
Vibration, shock, thermoshock, moisture and salt spray
resistant
The L-Series rocker switch is an innovative product oering
total design exibility, while at the same time setting new
standards for performance and reliability. Its versatile design
features include a neatly proportioned size that ts into an
industry standard mounting hole of 1.734 x .867 (44.0mm
x 22.0mm), countless unique choices for ratings, circuits,
colors, illuminations and laser etched legends. These single or
double pole switches also feature a broad choice of actuator
styles, colors, and lenses with up to twelve terminals oering
an extensive range of switch and lamp circuit options,
including LED or incandescent illumination. Additionally, an
optional plug-in terminal connector enables pre-wiring of
wire your harness.
Typical Applications:
Construction machinery
Agricultural equipment
On-highway transportation equipment
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
2 |L–Series Sealed Rocker Switches
LED LAMPS
Utilize less current and are not
aected by vibration, providing
long lasting illumination.
Available in 3 standard colors.
SEAL PROTECTION
Locks out elements such as
water, dust & debris. Certied
to IP67 for front panel
components.
TERMINALS
Available with 2 industry
standard termination options:
.250 or .187 tabs with up to 12
terminal options.
L-Series Switch
DESIGN FEATURES
ACTUATOR
Available in rocker or
paddle styles. Several
standard color options
also available.
ROLLER PIN
Eliminates need for
lubricants, increasing the
temperature range of the
switch from -40˚ C to +85˚C
[-40˚ F to 185˚ F].
LENS & LEGENDS
Lens available in 2 sizes and 6
standard colors in either translucent
or transparent materials. Numerous
symbols and text available for
imprinting or laser etching.
BASE
Fits into industry
standard mounting
hole of 1.734 x .867 in
[44.0mm x 22.0mm].
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 3
L–Series Sealed Rocker Switches - General Specifications
*Manufacturer reserves the right to change product specification without prior notice.
TEST CUT
HOLE IN
ACTUAL
MATERIAL
MOUNTING HOLE
T2
OUTPUT
(LOAD)
T1
BAT
.100 [2.54]
2.265 [57.53]
3.055 [77.60]
1.734 [44.04]
.867 [22.02]
1.970
PADDLE STYLE ACTUATOR
.250 X .031
[6.35 X .79]
T3
GROUND
.260 [6.60]
.390 [9.91]
Panel Thickness Range
Acceptable Panel Thickness
.030 to .156 (.76mm to 3.96mm)
Recommended:
.030, .062, .093, .125 and .156
1.020 [25.91]
.344 [8.74]
1.300 [33.02]
2.0-1.0
1.0-.80
.50-.35
.80.-.50 (2 REQ'D)
MM
16-14
12
20-22
20-18
AWG
3.012052224
12015870
12015869
12020035
12052222
PACKARD
PART NO.
12
12084590 3.0
WIRE GAGE
Q.C. SELECTION GUIDE
22-18 (2 REQ'D)
COMPANY
SERIES
PACKARD
METRI-PACK
630 SERIES
TIN PLATED
BRASS
1.570 [39.88]
1.060 [26.92]
1.340 [34.04]
2
Electrical
Contact Rating .4VA @ 24VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
20 amps, 4-14VDC
15 amps, 15-28VDC
Dielectric Strength 1250 Volts RMS between pole to
pole
3750 Volts RMS between live
parts and accessible surfaces
Insulation Resistance 50 Megaohms
Initial Contact Resistance 10 milliohms max. @ 4 VDC
Life 100,000 cycles maintained,
50,000 cycles momentary at rated
voltage and current
Contacts 90/10 silver-nickel, silver tin-oxide,
gold
Terminals Brass or copper/silver plate
3/16” (4.76mm) & 1/4” (6.3mm)
Quick Connect terminations
standard.
Mechanical
Endurance 250,000 cycles minimum
Physical
Lighted Incandescent - rated 10,000
hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for
voltages to 24 VDC)
Seals Rocker, base & bracket are
sealed.
Base Nylon 66 GF rated to 85°C with a
ammabilityratingof94V0.
Actuator Basic actuator structure molded
of thermoplastic polycarbonate
with a hard Nylon 66
thermoplastic surface overlay.
Lock Acetal
Lens Polycarbonate rated at 100°C
Function 2 & 3 Position Rocker Style
Bracket Nylon Zytel
Connector Nylon 66 rated at 85°C. Polarized.
Actuator Travel (Angular Displacement)
2 position 26°
3 positions 13° from center
Environmental
Environmental IP67 for above panel components
of the actual switch, representing
an index of protection as applied
to electrical equipment in
accordance with IEC 529, BS
5490, DIN 400 50 & NFC 20 010.
Corrosion Mixed Flowing Gas MFG Class III
per ASTM B-827 & B-845, Method
H, with 3 years exposure.
Operating Temperature -40°C to + 85°C
Vibration 1 Per Mil-Std 202F, Method 204D
Test Condition A 0.06 DA or
10G’s 10-500 Hz. Tested with VCH
connector. Test criteria - No
loss of circuit during test and pre
and post test contact resistance.
Vibration 2 Resonance search
24-50 Hz 0.40 DA
50-2000 ±10 G’s peak
Results Horizontal Axis 3-5 G’s
max.
Random
24 Hz 0.06 PSD-Gsq/Hz
60 Hz 0.50
100 Hz 0.50
200 Hz 0.025
2000 Hz 0.025
No loss of circuit during test; <10µ
chatter.
Shock Per Mil-Std 202F, Method 213B,
Test Condition K @ 30G’s. Tested
with VCH connector. Test criteria
- No loss of circuit during test,
pre, and post test contact
resistance.
Salt Spray Per Mil-Std 202F, Method 101D,
Test Condition A, 48 Hrs.
Thermal Shock Per Mil-Std 202F, Method 107F,
Test Condition A, -55°C to 85°C.
Test criteria - pre and post test
contact resistance.
Moisture Resistance Per Mil-Std 202F, Method 106F,
Test Criteria - pre and post test
contact resistance.
Mounting Specifications
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
4 |L-Series Sealed Rocker Switches – Ordering Scheme
2 CIRCUIT2
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lamp
7
Lamp
8
Bracket
9
Actuator
10
Lens Style
& Color
11
Lens Style
& Color
12
Legend
14
Actuator
Lens Legend
13
Legend
Orientation
4
Termination
L11 3 C 3 A
Terminal Orientation
Position:
SP DP
11 21
12 22
13 23
14 24
15 25
16 26
17 27
18 28
CIRCUITS WITH JUMPER TERMINALS
30*
31
PROGRESSIVE CIRCUITS
51
52
53
54
55
56
57
58*
61
62
63
64
65
66
67
68
69*
70
71
72
73
80
HAZARD WARNING CIRCUITS
A2
A3
* Available with ratings 1, 4, & E only.
45 48E H N 1 A 1
1 SERIES
L
3 RATING2
1 .4VA @ 28VDC Resistive
4 10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings
B 15A 24V
C 20A 18V
D 20A 12V
E 15A 12V
G 20A 6V
H 20A 3V
4 TERMINATION2,3
1 .250 (6.4mm) TAB (QC)
3 .187 (4.7mm) TAB (QC)
( )
- momentary
SP - single pole - uses terminals 1, 2 & 4.
DP - double pole uses terminals 5, 6 & 8.
Terminals 9, 10 & 11 for lamp circuit only.
3
1 & 2, 5 & 6
OFF
OFF
(OFF)
ON
(ON)
ON
(ON)
(ON)
(1,2&8), (4,5&6)
2, 4 & 8
1 & 2
OFF
1 & 2
OFF
(1 & 2)
(OFF)
(OFF)
1 & 2
1 & 2, 5 & 6
OFF, OFF
1 & 2, 5 & 6
OFF, OFF
(1 & 2), (5 & 6)
(OFF, OFF)
(OFF, OFF)
OFF, OFF
OFF, OFF
(1 & 2), (5 & 7)
1 & 2, 5 & 7
1 & 2, 5 & 7
OFF, OFF
OFF, 5 & 6
OFF, 1 & 2
OFF, 1 & 2
2
Connected Terminals
NONE
NONE
NONE
NONE
NONE
OFF
OFF
OFF
OFF, OFF
2, 3 & 7
2 & 3
2 & 3
2 & 3
2 & 3
2 & 3
2 & 3
2 & 3
2 & 3
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 4, OFF
2 & 4, OFF
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, OFF
2 & 4, OFF
NONE
NONE
1
2 & 4, 6 & 8
ON
(ON)
ON
ON
ON
ON
ON
(ON)
(2,4&5), (1,6&8)
1, 2 & 5
3 & 4
3 & 4
(3 & 4)
(3 & 4)
(3 & 4)
(3 & 4)
3 & 4
2 & 4
3 & 4, 7 & 8
3 & 4, 7 & 8
(3&4), (7&8)
(3&4), (7&8)
(3&4), (7&8)
(3&4), (7&8)
3 & 4, 7 & 8
2 & 4, 7 & 8
2 & 4, 1, 7 & 8
(2&4), (7&8)
(2&4), (7&8)
2 & 4, 7 & 8
(2&4), (7&8)
2 & 4, 6 & 8
6,7&8,3&4
6,7&8,2&4
13 LEGEND ORIENTATION
0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1 - vertical, lamp 1 on top
2 Orientation 2 - horizontal, lamp 1 on right
3 Orientation 3 - vertical, lamp 1 on bottom
4 Orientation 4 - vertical, lamp 1 on left
Orientation
1
Orientation
2
Orientation
3
Orientation
4
3AA-146
46 46
3AA-246
AA
AA
5 ILLUMINATION
Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end
of switch. Positive (+) and negative (-) symbols apply to LED lamps only.
S
A
B
C
D
E
F4
G
H
J
1
2
Lamp wired to Terminals
10+ 9-
12+ 11-
10+ 9-
12+ 9-
4+ 9-
10+ 9-
4+ 9-
10+ 9-
8+ 9-
4+ 9-
10+ 9-
10+ 9-
4+ 9-
1+ 9-
6+ 10- 12-
6+ 10- 12-
Illumination Type
Independent
Independent
Independent
Independent
Dependent
Independent
Dependent
Independent
Dependent
Dependent
Independent
Both Independent
(in series)
Dependent
Dependent
Hazard
Hazard
Lamps
NONE
# 1
# 2
# 1
& # 2
# 1
# 1
& # 2
# 1
& # 2
# 1
& # 2
# 1
& # 2
# 1
& # 2
# 2
# 1
8 BRACKET COLOR1
Standard Bracket
Rockerguard at Lamp 1
Rockerguard at Lamp 2
Black
1
A
E
White
2
B
F
Gray
3
C
G
Red
4
D
H
9 ACTUATOR STYLE AND COLOR1
Rocker
Paddle
Black
A
J
White
B
N
Gray
C
K
Red
D
M
Laser Etched
3
4
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
Selection 6: above terminals 10 & 9; Selection 7: above terminals 12 & 11
No lamp
Incandescent
LED*
2VDC
6VDC
12VDC
24VDC
* Consult factory for “daylight bright”, blue/green and white LED options.
Typical current draw for LED is 20ma.
0
4 3V
Red
A
B
C
D
6 12V
Green
F
G
H
J
7 18V 8 24V
5 6V
Amber
L
M
N
P
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 Circuits 30, 31, 58, 69 are not available with rating codes 4, C, D, G or H.
3 Termination 3 only available with rating codes 1, B, and E.
4 Not available with circuits 11-18, 51-57 and 69.
12 LASER ETCHED, LENS OR BODY LEGEND
00 No legend this location / no actuator
For legend options & codes, visit us at carlingtech.com
14 ACTUATOR LENS LEGEND
00 No legend this location / no actuator
For legend options & codes, visit us at carlingtech.com
10 & 11 LENS STYLE AND COLOR
Lens color for LEDs must be clear, white, or match color of LED.
0 - No Actuator Z - No Lens
Clear
1
-
3
-
5
White
-
7
-
9
A
Amber
B
C
D
E
-
Green
G
H
J
K
-
Red
M
N
P
R
-
Blue
T Large Transparent
U Large Translucent
V Bar Transparent
W Bar Translucent
- Laser Etched background color
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 5
2 CIRCUIT5
Terminal Orientation
Position:
SP DP
11 21
14 24
16 26
17 27
18 28
CIRCUITS WITH JUMPER TERMINALS
302
312
PROGRESSIVE CIRCUITS
51
52
53
54
55
56
57
58
61
62
63
64
65
66
67
68
69
70
71
72
73
80
( )
- momentary
SP - single pole - uses terminals 1, 2 & 4.
DP - double pole uses terminals 5, 6 & 8.
Terminals 9, 10 & 11 for lamp circuit only.
3 (Lock location)
1 & 2, 5 & 6
OFF
ON
ON
(ON)
(ON)
(1,2&8), (4,5&6)
2, 4 & 8
1 & 2
OFF
1 & 2
OFF
(1 & 2)
(OFF)
(OFF)
1 & 2
1 & 2, 5 & 6
OFF, OFF
1 & 2, 5 & 6
OFF, OFF
(1 & 2), (5 & 6)
(OFF, OFF)
(OFF, OFF)
OFF, OFF
OFF, OFF
(1 & 2), (5 & 7)
1 & 2, 5 & 7
1 & 2, 5 & 7
OFF, OFF
OFF, 5 & 6
2
Connected Terminals
NONE
NONE
OFF
OFF
OFF
OFF, OFF
2, 3 & 7
2 & 3
2 & 3
2 & 3
2 & 3
2 & 3
2 & 3
2 & 3
2 & 3
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 4, OFF
2 & 4, OFF
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, OFF
2 & 4, OFF
1
2 & 4, 6 & 8
ON
ON
ON
ON
(ON)
(2,4&5), (1,6&8)
1, 2 & 5
3 & 4
3 & 4
(3 & 4)
(3 & 4)
(3 & 4)
(3 & 4)
3 & 4
2 & 4
3 & 4, 7 & 8
3 & 4, 7 & 8
(3&4), (7&8)
(3&4), (7&8)
(3&4), (7&8)
(3&4), (7&8)
3 & 4, 7 & 8
2 & 4, 7 & 8
2 & 4, 1, 7 & 8
(2&4), (7&8)
(2&4), (7&8)
2 & 4, 7 & 8
(2&4), (7&8)
2 & 4, 6 & 8
L-Series Sealed Locking Rocker Switches – Ordering Scheme
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lock
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Lock
12
Legend
13
Legend
Orientation
4
Termination
L11 1 S P M 00D W C J H 0
1 SERIES
L
3 RATING5
1 .4VA @ 28VDC Resistive
4 10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings
B 15A 24V
C 20A 18V
D 20A 12V
E 15A 12V
G 20A 6V
H 20A 3V
4 TERMINATION4
1 .250 (6.4mm) TAB (QC)
3 .187 (4.7mm) TAB (QC)
13 LEGEND ORIENTATION
0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1 - vertical, lamp 1 on top
2 Orientation 2 - horizontal, lamp 1 on right
3 Orientation 3 - vertical, lamp 1 on bottom
4 Orientation 4 - vertical, lamp 1 on left
ORIENTATION 1
LOCK
ORIENTATION OF
ACTUATOR/LENS IN PANEL
P
LOCK
LOCK
PP
LOCK
P
ORIENTATION 3
ORIENTATION 2
ORIENTATION 4
PZAY2-2
LOCK
PZAY2-1
LOCK
P
P
9 ACTUATOR STYLE AND COLOR1
Locking Rocker
Black
P
Red
R
7 LAMP
Above terminals 12 & 11
No lamp
Incandescent
LED*
2VDC
6VDC
12VDC
24VDC
* Consult factory for “daylight bright”, blue/green and white LED options.
Typical current draw for LED is 20ma.
0
4 3V
Red
A
B
C
D
6 12V
Green
F
G
H
J
7 18V 8 24V5 6V
Amber
L
M
N
P
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 Additional lamp circuits available. Consult factory.
3 Available only with 3 position circuits.
4 Termination 3 only available with ratings 1, B and E.
5 Circuits 30, 31, 58 and 69, are not available with rating codes 4, C, D, G or H.
12 LASER ETCHED, LENS OR BODY LEGEND
00 No legend this location / no actuator
For legend options & codes, visit us at carlingtech.com
6 LOCK
W Lock above terminals 10 & 9.
8 BRACKET COLOR1
J Black
10 LENS STYLE AND COLOR
Lens color for LEDs must be clear, white, or match color of LED.
0 - No Actuator Z - No Lens
Clear
1
-
3
-
White
-
7
-
9
Amber
B
C
D
E
Green
G
H
J
K
Red
M
N
P
R
Blue
T Large Transparent
U Large Translucent
V Bar Transparent
W Bar Translucent
11 LOCK FUNCTION AND COLOR
Locking Position
Up
A
B
C
D
E
Down
H
J
K
L
M
Up & Down
R
S
T
V
W
Center3
1
2
3
4
5
Lock Color
Match Actuator
Black
White
Red
Safety Orange
5 ILLUMINATION2
Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end
of switch. Positive (+) and negative (-) symbols apply to LED lamps only.
S
B
Lamp wired to Terminals
12+ 11-
Illumination Type
Independent
Lamps
NONE
# 2
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
6 |L-Series Sealed Rocker Switches – Dimensional Specifications in. [mm]
1.325 [33.66]
.920 [23.37]
.855 [21.72]
1.970 [50.04]
1.970 [50.04]
.855 [21.72]
.790 [20.07]
1.970 [50.04]
1.710 [43.43]
.500 [12.70]
L-SERIES
SHOWN WITH LASER ETCHED
ACTUATOR
1.450 [36.83]
.400 [10.16]
L-SERIES
CONNECTOR
.400 [10.16]
L-SERIES
SHOWN WITH LARGE LENS
AND PADDLE ACTUATOR
1.020 [25.91]
.435 [10.16]
L-SERIES
SHOWN WITH BAR LENS, LOCK
AND CONNECTOR
L-SERIES
HOLE PLUG
1.020 [25.91]
2.380 [60.45]
.453 [11.51]
L-SERIES
SHOWN WITH ROCKER GUARD
1.020 [25.91]
.300 [7.62]
12 4 3 21 10
12 4 3 21 10
LH1 REMOVABLE HOLE PLUG
WITH NON-SERRATED WINGS
LH2 HOLE PLUG WITH
SERRATED WINGS
LC1-01 BLACK .250 TAB CONNECTOR (PACKARD 630 SERIES)
LC2-01 BLACK .187 TAB CONNECTOR (PACKARD 480 SERIES)
LC3-01 BLACK .250 TAB CONNECTOR (AMP ONLY)
Dimensional Specifications: in. [mm]
Connector Hole Plug
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 7
L-Series Sealed Rocker Switches – Dimensional Specifications in. [mm]
+.008
-.000
+.008
-.000
+.008
-.000
+.008
-.000
1.700 [43.18]
TEST
CUT
HOLE IN
ACTUAL
MATERIAL
2.020 [51.31]
1.187 [30.15]
TEST
CUT
HOLE IN
ACTUAL
MATERIAL
.984 [25.00]
LMM MOUNTING PANEL
MIDDLE
1.030 [26.16]
LMS
MOUNTING PANEL
1.340 [34.04]
2.300 [58.42]
1.900 [48.26]
2.300 [58.42]
2.300 [58.42]
6.490 [164.85]
.670 [17.02]
2.300 [58.42]
1.990 [50.55]
R .093 MAX TYP
1.900 [48.26]
2.300 [58.42]
1.030 [26.16]
3.400 [86.36]
LME MOUNTING PANEL
END
R .093 MAX TYP
1.030 [26.16]
LMS
MOUNTING PANEL
HOLE
MOUNTING PANEL
OPENING
(2) UNITS
LM6 MOUNTING PANEL
PANEL OPENING SIZE: 1.90 X 6.15 [48.3mm X 156.2mm]
LM4 MOUNTING PANEL
PANEL OPENING SIZE: 1.90 X 4.09 [48.3mm X 103.9mm]
1.030 [26.16]
4.430 [112.52]
2.300 [58.42]
MOUNTING PANEL
FOR ADDITIONAL UNITS, ADD 1.03 [26.2] PER UNIT.
FOR MORE THAN 2 L-SERIES SWITCHES, ADD MIDDLE
SECTION. AVAILABLE IN PANEL THICKNESSES LISTED
BELOW. CONSULT FACTORY
DIMENSIONS: LME 2.02 [51.3mm] PLUS NUMBER OF
CENTER BEZELS (LMM) X 1.034 [26.26mm]
MOUNTING PANEL THICKNESS
.062 [1.57]
.093 [2.36]
.125 [3.17]
.156 [3.96]
LM3 MOUNTING PANEL
PANEL OPENING SIZE: 1.90 X 3.06 [48.3mm X 77.7mm]
.670 [17.02]
Dimensional Specifications: in. [mm]
CIRCUIT
CODE
11
SCHEMATIC CIRCUIT
CODE SCHEMATIC
2
4
6
5
2
4
6
5
2
4
2
4
2
4
2
4
1
2
4
1
2
4
1
2
4
1
2
4
1
2
4
6
8
12
13
14
15
16
17
18
21
22
23
24
25
26
27
28
30
31
51
52
53
54
55
56
57
58
61
CIRCUIT
CODE SCHEMATIC
2
4
6
58
1
2
4
6
58
1
2
4
6
58
1
2
4
6
58
1
2
458
1
6
2
458
1
6
2
458
17
3
2
4
13
4
2
3
1
8
6
7
5
4
2
3
4
2
3
4
2
3
1
4
2
3
4
2
3
1
4
2
3
4
2
3
1
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
8 |L-Series Switch – Circuit Diagrams
INTERNAL
CONNECTION
INTERNAL
CONNECTION
4
7
2
70
1 5
4
7
4
2
6
6
69
67
7
4
2
42
42
3
6
5
3
68
66
42
3
64
2
2
65
6
63
1
3
4
4 6
SCHEMATIC
5
8
3
6
3
3
6
7
2
3
1
6
A3
6
2
1
8
8
62
CIRCUIT
CODE
1 2
1 4
8
8
A2
4 5
8
7
3
8
7
2
4
1
7
81
2
82
8
4 5
80
2
6
73
8
7
4
8
6
8
51
8
4
1
5
4
7
82
7
7
7
72
7 8
1 5
71
SCHEMATIC
2
8
8
7
CIRCUIT
CODE
4 8
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 9
L-Series Switch – Circuit Diagrams
B
+12
+12
A
ILLUMIN.
CODE
-9
+10
+4
+10
-9
1
-9
1
E
2
2
1
-9
2
1
-11
2
D
F
+10
-9
-9
+10
+8
G
1
+4
2
SCHEMATIC
+10
C
1
2
+4
ILLUMIN.
CODE SCHEMATIC
1
J
1
1
1
H
+10
-9
2
K
INTERNAL
CONNECTION
-12
2
+10
INTERNAL
CONNECTION
+10
(+)10
+4
2
-12
-9 +1
1
3 POSITION
SYMBOL
TERMINAL LOCATION
LAMP LOCATION
MAINTAINED CIRCUIT
MOMENTARY CIRCUIT
INTERNAL CONNECTION
(JUMPER TERMINAL)
2 POSITION CONNECTION
LEGEND
2 POSITION
P3
P3
P1
P1
P2
DEFINITION
(–)9
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
10 |L-Series Series - Lamp Circuit Diagrams
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 11
* Intentionally left blank
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
Email: sales@carlingtech.com
Northern Region Sales Oce: nrsm@carlingtech.com
Southeast Region Sales Oce: sersm@carlingtech.com
Midwest Region Sales Oce: mrsm@carlingtech.com
West Region Sales Oce: wrsm@carlingtech.com
Latin America Sales Oce: larsm@carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacic Ltd.,
Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
Email: sales@carlingtech.com.hk
Shenzhen, China: shenzhen@carlingtech.com
Shanghai, China: shanghai@carlingtech.com
Pune, India: india@carlingtech.com
Kaohsiung, Taiwan: taiwan@carlingtech.com
Yokohama, Japan: japan@carlingtech.com
Europe | Middle East | Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
Email: ltd.sales@carlingtech.com
Germany: gmbh@carlingtech.com
France: sas@carlingtech.com
www.carlingtech.com REV_03_2015