PG-100N FEATURES Zero point adjustment button Excellent stability igh precision semiconductor chip combined with temperature H compensation circuit guarantee excellent stability. Pressure port Easy, one-handed operation Easy-to-read large LCD display Long battery life Lasts more than 1000hrs with two AAA dry batteries. Automatic power off function One-touch zero-point calibration Analog output available Pressure unit selectable type also available (PG-100N--W) Hold button Unit of display OUTLINE DIMENSIONS W55mm x H110 x D16.9mm MODEL NUMBER DESIGNATION *** Traceability system chart BlankNot attached TTraceability system chart Series name Rated pressure range 101 10 ~ 10 kPa 102 100 ~ 100 kPa 103 100 ~ 1000 kPa Inspection report / Calibration Certificate BlankNot attached X1 Inspection report X2 Inspection report and Calibration certificate Pressure reference RGauge(Compound) Unit of display BlankkPa MMPa HmmHg WSelectable pressure units ... kPa, MPa, psi, bar, mmHg, inHg, mmAq LIST OF MODEL NUMBERS For non-corrosive gas Pressure reference Rated pressure range (kPa) Unit of display : kPa Gauge PG-100N-101R- PG-100N-102R- PG-100N-103R- PG-100N-103R-M Unit of display : MPa Model number Unit of display : mmHg PG-100N-101R-H PG-100N-102R-H Selectable pressure units PG-100N-101R-W PG-100N-102R-W Specifications are subject to change without notice. PG-100N-103R-W PG-100N STANDARD SPECIFICATIONS kPa version Unless otherwise specified, the specs are defined at an ambient temperature of 25 5 C. Item PG-100N Gauge Pressure reference General specifications Model number 101R 102R 103R Rated pressure range kPa 10 ~ 10 100 ~ 100 100 ~ 1000 Maximum pressure kPa 20 200 1500 Break-down pressure kPa 50 500 2000 Operating temp. range C 0 ~ 50 Compensated temp. range C 0 ~ 50 Operating humidity % RH Storage temp. 15 ~ 85 No condensation C 20 ~ 70 Atmospheric pressure, humidity 65 %RH maximum Pressure medium Non-corrosive gases Pressure port Net weight M 5 female g Approx. 100 Display Power AAA dry battery DC 1.5 V x 2 Battery life 1000 h minimum No. of digits 3 1/2 Display element LCD Rated display range kPa 10.00 ~ 10.00 100.0 ~ 100.0 Display cycle 100 ~ 1000 . 100 ~ 1.000MPa Approx. 4 times/s 0.5 %F.S. 2 digits (at 25 C 5 C) Integrated accuracy 1.5 %F.S. 2 digits (at 25 C 25 C) 1.0 %F.S. 2 digits (at 25 C 25 C) Resolution 1 digit Analog output Power supply (External supply) Output voltage 5 0.5 V DC 5 mA maximum 0 ~ 1.000 V mV Proportionate to display value Output accuracy / Resolution 10 mV / 1mV Output resistance Approx. 10 k Response Approx. 10 ms Additional function Auto power off, Display hold, Battery replacement display (LOBAT), Zero point adjustment Accessories 2 fittings (half union for 6mm OD tube, barb fitting for 4mm OD tube), 2 AAA batteries, strap Option (Sold seperately) Specifications are subject to change without notice. PG-100N soft carrying case PG-100N STANDARD SPECIFICATIONS Non SI unit version Unless otherwise specified, the specs are defined at an ambient temperature of 25 5 C. PG-100N Item Gauge Pressure reference Model number (mmHg display : compound) Rated pressure range General specifications Maximum pressure Break-down pressure kPa (mmHg) kPa (mmHg) kPa (mmHg) 101R-H 102R-H 10 ~ 10 (75.0 ~ 75.0) 20 (150) 50 (375) 100 ~ 100 (750 ~ 750) 200 (1500) 500 (3750) Operating temp. range C 0 ~ 50 Compensated temp. range C 0 ~ 50 Operating humidity % RH Storage temp. 35 ~ 85No condensation C 20 ~ 70Atmospheric pressure, humidity 65 %RH maximum Pressure medium Non-corrosive gases Pressure port Net weight M 5 female g Approx. 100 AAA dry battery DC 1.5 V x 2 Battery life 1000 h minimum Display Power No. of digits 3 1/2 Display element LCD 75.0 ~ 75.0 Rated display range (mmHg display) Display cycle 750 ~ 750 Approx. 4 times/s 0.5 %F.S. 2 digits (at 25 C 5 C) Integrated accuracy 1.5 %F.S. 2 digits (at 25 C 25 C) 1 digit Resolution 5 0.5 V DC 5 mA maximum Analog output Power supply (External supply) Output voltage 1.0 %F.S. 2 digits (at 25 C 25 C) mV 0 ~ 1.000 V Proportionate to display value Output accuracy / Pesolution 10 mV / 1 mV Output resistance Approx. 10 k Response Approx. 10 ms Additional function Auto power off, Display hold, Battery replacement display (LOBAT), Zero point adjustment Accessories 2 fittings (half union for 6mm OD tube, barb fitting for 4mm OD tube), 2 AAA batteries, strap Option (Sold seperately) Specifications are subject to change without notice. PG-100N soft carrying case PG-100N ENVIRONMENTAL CHARACTERISTICS Test conditions (At 25 5 C) Test item Permissible change Amplitude 1.5 mm P-P, 10 ~ 55 Hz, Vibration 3 directions for 2 hours each (packed) Shock 98.1 m/s2, 3 directions for 3 times each (packed) Indicating accuracy: 1 %F.S. maximum Pressure cycling 0 ~ Rated pressure, 10 6 cycles Moisture resistance 40 C, 90 ~ 95 %RH, 240 hrs. OUTLINE DIMENSIONS Unless otherwise specified, tolerance : 0.5 (Unit: mm) 16.9 Pressure port M5 female 55 Pressure medium Strap HANDY MANOMETER Display AIR TYPE O. SET LOBAT HOLD b a r p s i i n , mm H g A q POWER Mk Pa SET HOLD UP ZERO 110 MODE Zero adjust button Power button Hold button COPAL ELECTRONICS Specifications are subject to change without notice. Nameplate