JJM
ORDERING INFORMATION
TYPES
Standard packing; Carton (tube): 50 pcs.; Case: 1,000 pcs.
RATING
1. Coil data
Note: Other pick-up voltage types are also available. Please contact us for details.
COMPACT SIZE
AUTOMOTIVE RELAY
JJ-M RELAYS
Contact arrangement Coil voltage Part No.
1 Form A 12 V DC JJM1a-12V
1 Form C 12 V DC JJM1-12V
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Usable voltage range
12V DC Max. 7.2 V DC
(Initial)
Min. 1.0 V DC
(Initial) 53.3 mA 225640 mW 10 to 16V DC
FEATURES
• Compact (half-size).
The base area is approximately half the
size of conventional (JS-M) relays. The
controller unit can be made more
compact.
Base area has been reduced by one half
• Perfect for automobile electrical
systems.
Over 2 × 105 openings possible with a 14
V DC motor load, an inrush current of 25
A, and steady state current of 5 A.
(N.O. side)
• Standard terminal pitch employed
The terminal array used is identical to
that used in small automotive relays.
• Plastic sealed type.
Plastically sealed for automatic cleaning.
• Line-up of 1 Form A and 1 Form C.
TYPICAL APPLICATIONS
• Power windows
• Auto door lock
• Electrically powered sun roof
• Electrically powered mirror
• Cornerring lamp, etc.
JSM JJM
16
22
12
15.5
.630
.866
.472
.610
Contact arrangement
1:
1a:
1 Form C
1 Form A
JJM
Coil voltage (DC)
12 V
ASCTB234E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
RoHS compliant
JJM
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Please refer to “Usage ambient
condition” in CAUTIONS FOR USE OF AUTOMOTIVE RELAYS.
Please inquire if you will be using the relay in a high temperature atmosphere (110°C 230°F).
*3. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 1 Form A 1 Form C
Contact resistance (Initial) Typ 5m (By voltage drop 6V DC 1A)
Contact material Ag alloy (Cadmium free)
Rating
Nominal switching capacity
(resistive load) 20 A 14V DC N.O.: 20 A 14V DC
N.C.: 10 A 14V DC
Max. carrying current (12V DC)*3N.O.: 35 A (at 20°C 68°F for 2 minutes), 25 A (at 20°C 68°F for 1 hour),
30 A (at 85°C 185°F for 2 minutes), 20 A (at 85°C 185°F for 1 hour)
Nominal operating power 640 mW
Min. switching capacity
(resistive load)*11 A 12V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 100 M (at 500V DC, Measurement at same location as “Break down voltage” section)
Breakdown
voltage (Initial)
Between open
contacts 500 Vrms for 1 min. (Detection current: 10mA)
Between contacts
and coil 500 Vrms for 1 min. (Detection current: 10mA)
Operate time (at nominal voltage) Max. 10ms (at 20°C 68°F, excluding contact bounce time) (Initial)
Release time (at nominal voltage) Max. 10ms (at 20°C 68°F, excluding contact bounce time) (Initial)
Mechanical
characteristics
Shock
resistance
Functional Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Destructive Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
Vibration
resistance
Functional 10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10µs)
Destructive 10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G},
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Expected life
Mechanical Min. 107 (at 120 cpm)
Electrical
<Resistive load>
Min. 105 (at nominal switching capacity)
(operating frequency: 1s ON, 9s OFF)
<Motor load>
Min. 2 × 105 (at Inrush 25A, Steady 5A 14 V DC)
Min. 5 × 104 (at 20A 14 V DC motor lock)
(operating frequency: 0.5s ON, 9.5s OFF)
<Resistive load>
N.O.: Min. 105 (at nominal switching capacity)
N.C.: Min. 105 (at nominal switching capacity)
(operating frequency: 1s ON, 9s OFF)
<Motor load>
N.O.: Min. 2 × 105 (at Inrush 25A, Steady 5A 14 V DC),
Min. 5 × 104 (at 20A 14 V DC motor lock)
N.C.: Min. 2 × 105 (at 20A 14 V DC brake currect)
(operating frequency: 0.5s ON, 9.5s OFF)
Conditions
Conditions for operation, transport and
storage*2
Ambient temperature: –40°C to +85°C –40°F to +185°F,
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 6 cpm (at nominal switching capacity)
Mass Approx. 5g .176 oz
1. Coil temperature rise
Sample: JJM1-12V, 6pcs
Point measured: Inside the coil
Contact current: Non current through
contact, 5A, 10A, 15A, 20A
Resistance method, ambient temperature 85°C 185°F
2. Max. switching capability
(Resistive load, initial)
3. Ambient temperature and operating voltage
range
0
20
40
60
80
100
120
12 14 16
Temperature rise, °C
Coil applied voltage, V
20A
15A
10A
5A
Non current
through
contact
0
10
50
40
30
20
60
020304010 50
(N.O. side: room temperature)
Switching current, A
Switching voltage, VDC
0
5
10
15
35
30
25
20
40
40 20 20 40 60 1000 120
8085
Coil applied voltage, VDC
Ambient temperature, °C
Pick-up voltage
(cold start)
ASCTB234E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
JJM
4. Distribution of pick-up and drop-out voltage
Sample: JJM1-12V, 100pcs
5. Distribution of operate time
Sample: JJM1-12V, 100pcs
6. Distribution of release time
Sample: JJM1-12V, 100pcs
* Without diode
0
30
20
10
40
50
60
70
Voltage, V
7.5
Pick-up voltage
Drop-out voltage
1.5
1.00.50 2.0 2.5 3.0 3.5 4.5 5.0
4.0 5.5 6.0 6.5 7.0
Quantity, n
0
30
20
10
40
50
60
70
Time, ms
3.02.01.5 2.5 3.5 4.5 5.04.0
Quantity, n
0
30
20
10
40
50
60
70
1.50.50 1.0 2.0 3.0 3.52.5
Time, ms
Quantity, n
7-(1). Electrical life test (at resistive load)
Sample: JJM1-12V
Quantity: n = 6 (NC = 3, NO = 3)
Load: Resisitive load (NC side: 10A 14 V DC, NO side:
20 A 14 V DC); Operating frequency: ON 1s, OFF 9s
Ambient temperature: Room temperature
0510
0
1
2
3
4
5
6
7
Max.
Max.
Min.
Min.
X
X
No. of operations, × 104
Pick-up and drop-out voltage, V
Pick-up voltage
Drop-out voltage
Contact welding: 0 time
Miscontact: 0 time
7-(2). Electrical life test (Motor free)
Sample: JJM1-12V, 6pcs.
Load: Inrush 25A, Steady 5A, Brake current 18A 14V
DC, Power window motor load (Free condition).
Operating frequency: ON 0.5s, OFF 9.5s
Ambient temperature: Room temperature
Circuit :
Change of pick-up and drop-out voltage Change of contact resistance
Tested sample
M
8
7
6
5
4
3
2
1
0510
0
Max.
Min.
X
Max.
Min.
X
Pick-up and drop-out voltage, V
No. of operations, × 104
Pick-up voltage
Drop-out voltage
Contact welding: 0 time
Miscontact: 0 time N.O. side
0
No. of operations, × 104
Max.
Min.
X(N.C.)
30
20
10
50
40
0
Contact resistance, m
2010
Max.
Min.
X(N.O.)
N.C. side
7-(3). Electrical life test (Motor lock)
Sample: JJM1-12V, 6pcs.
Load: 20A, 14VDC,
Power window motor actual load (lock condition).
Operating frequency: ON 1s, OFF 5s
Ambient temperature: Room temperature
Circuit :
Change of pick-up and drop-out voltage Change of contact resistance
Tested sample
M
0 2.5 5
7
3
4
5
6
1
2
0
Max.
Min.
X
Max.
Min.
X
Pick-up and drop-out voltage, V
No. of operations, × 104
Pick-up voltage
Drop-out voltage
Contact welding: 0 time
Miscontact: 0 time
0
No. of operations, × 104
Max.
Min.
X(N.C.)
10
20
30
40
50
0
Contact resistance, m
52.5
Max.
X(N.O.)
N.O. side
N.C. side
ASCTB234E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
JJM
DIMENSIONS (mm inch)
For Cautions for Use, see Relay Technical Information.
7-(4). Electrical life test (Lamp load)
Sample: JJM1-12V, 6pcs.
Load: 27W+21W, steady min. 4A, Lamp actual load
Operating frequency: ON 2s, OFF 13s
Ambient temperature: Room temperature
Circuit :
Change of pick-up and drop-out voltage Change of contact resistance
0
No. of operations, × 104
Max.
Max.
Min.
Min.
X
X
2
1
4
6
8
9
7
5
3
10
0
Pick-up and drop-out voltage, V
510
Pick-up voltage
Drop-out voltage
N.O. side
N.C. side
0
Max.
Min.
X(N.C)
10
30
20
40
50
0510
Max.
Min.
X(N.O.)
No. of operations, × 104
Contact resistance, m
Load current waveform
Inrush current: 42A, Steady current: 4.4A
10ms
10A
External dimensions
2.5
13.9
2-0.3 2-0.4
10.2
0.3
1.2
10.0
4-1.0
1.6±0.3
0.4
A
3.5
15.5 12
.547
.016
.138
.610 .472
.098
2-.012 2-.016
.402
.012
.047.394
4-.039
.063±.012
*Dimensions (thickness and width) of terminal is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
Note: Marked terminal is only for 1 Form C type
Schematic (Bottom view)
1a
1c
PC board pattern (Bottom view)
1a
1c
Tolerance: ±0.1 ±.004
COM
COIL
NO
COM
COIL
NO
NC
1.5 dia.
3-1.4 dia.
10.0
2.5 10.2
.059 dia.
3-.055 dia.
.394
.098 .402
1.5 dia.
4-1.4 dia.
10.0
2.5 10.2
.059 dia.
4-.055 dia.
.394
.098 .402
Dimension: General tolerance
Max. 1mm .039 inch:±0.1 ±.004
1 to 3mm .039 to .118 inch:±0.2 ±.008
Min. 3mm .118 inch:±0.3 ±.012
CAD Data
ASCTB234E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e