UCC284–5, UCC284–12, UCC284–ADJ, UCC384–5, UCC384–12, UCC384–ADJ
LOW-DROPOUT 0.5-A NEGATIVE LINEAR REGULATOR
SLUS234D – JANUARY 2000 – REVISED FEBRUARY 2002
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics TA = 0°C to 70°C for the UCC384 and –40°C to 85°C for the UCC284,
VIN = VOUT – 1.5 V, IOUT = 0 mA, COUT = 4.7 µF, and CT = 0.015 µF. For UCC384–ADJ, VOUT is set
to –3.3V (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
UCC384–5 Fixed –5-V 0.5-A Regulation Section
p
TA = 25°C–5.075 –5–4.925 V
Output voltage Over all conditions –5.100 –4.850 V
Line regulation VIN = –5.2 V to –15 V 1.5 10 mV
Load regulation IOUT = 0 mA to 0.5 A 0.1 0.25 %
Output noise voltage TA = 25°C, BW = 10 Hz to 10 kHz 200 µVRMS
p
IOUT 0.5 A, VOUT = –4.8 V 0.20 0.50 V
Dropout voltage, VOUT – VIN IOUT 50 mA, VOUT = –4.8 V 20 50 mV
UCC384–5 Fixed –5-V 0.5-A Power Supply Section
Input voltage range –15 –5.2 V
Quiescent current charge pump on VIN = –4.85 V, See Note 1 280 350 µA
Quiescent current VIN = –15 V 200 250 µA
Quiescent current in shutdown
VIN = –13 V, SD/CT = 0 V
TA = 0°C to 85°C, See Note 2 15 45 µA
Quiescent current in shutdown VIN = –13 V, SD/CT = 0 V
TA = –40°C to 0°C, See Note 2 100 µA
Shutdown threshold At shutdown pin (SD/CT) –1.0 –0.7 –0.4 V
Shutdown input current SD/CT = 0 V 5 10 25 µA
Output leakage in shutdown VIN = –15 V, VOUT = 0 V,
See Note 3 1 50 µA
Overtemperature shutdown 140 °C
Overtemperature hysteresis 20 °C
UCC384–5 Fixed –5-V 0.5-A Current Limit Section
Peak current limit VOUT = 0 V 0.7 1.1 1.5 A
Overcurrent threshold 0.55 0.7 0.9 A
Current limit duty cycle VOUT = 0 V 2.5 4 %
Overcurrent time out, tON VOUT = 0 V 300 500 700 µs
UCC384–12 Fixed 12-V 0.5-A Regulation Section
p
TA = 25°C–12.18 –12 –11.82 V
Output voltage Over all conditions –12.24 –11.64 V
Line regulation VIN = –12.5 V to –15 V 5 15 mV
Load regulation IOUT= 0 mA to 0.5 A 0.1 0.3 %
Output noise voltage TA = 25°C BW = 10 Hz to 10 kHz 200 µVRMS
p
IOUT 0.5 A, VOUT = –11.6 V 0.15 0.5 V
Dropout voltage, VOUT – VIN IOUT 50 mA, VOUT = –11.6 V 15 50 mV
UCC384–12 Fixed –12 V-0.5-A Power Supply Section
Input voltage range –15 –12.5 V
Quiescent current VIN = –15 V 220 350 µA
Quiescent current in shutdown
VIN = –13 V, SD/CT = 0 V
TA = 0°C to 85°C, See Note 2 15 45 µA
Quiescent current in shutdown VIN = –13 V, SD/CT = 0 V
TA = –40°C to 0°C, See Note 2 100 µA
NOTES: 1. The internal charge pump is enabled only for dropout condition with low VIN. Only in this condition is the charge pump required to
provide additional output FET fate drive to maintain dropout specifications. For conditions where the charge pump is not required,
it is disabled, which lowers overall device power consumption.
2. Ensured by design. Not production tested.
3. In the application during shutdown mode, output leakage current adds to quiescent current.