SPECIFICATION CONTROL DRAWING TITLE 55PC0212 Date WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED, MEDIUM WEIGHT, GENERAL PURPOSE, 600 VOLT 8-6-13 Revision D This specification sheet forms a part of the latest issue of Raychem Specification 55PC. INSULATION - RADIATION - CROSSLINKED, MODIFIED ETFE CONDUCTOR - SILVER-COATED COPPER CONSTRUCTION DETAILS PART NUMBER 1/ WIRE SIZE (AWG) CONDUCTOR STRANDING (number x AWG) 55PC0212-26-* 26 55PC0212-24-* 24 55PC0212-22-* 55PC0212-20-* CONDUCTOR DIAMETER (in.) FINISHED WIRE MAXIMUM RESISTANCE AT 20C (ohms/1000 ft.) LOWER SPEC LIMIT TARGET VALUE UPPER SPEC LIMIT 19 x 38 .0175 .0183 .0191 19 x 36 .0225 .0233 .0241 22 19 x 34 .0285 .0293 .0301 20 19 x 32 .0365 .0375 .0385 9.19 55PC0212-18-* 18 19 x 30 .0452 .0464 .0476 55PC0212-16-* 16 19 x 29 .0514 .0527 .0538 55PC0212-14-* 14 19 x 27 .0644 .0659 55PC0212-12-* 12 37 x 28 .0825 .0845 DIAMETER (in.) WEIGHT (lbs/1000 ft.) LOWER SPEC LIMIT TARGET VALUE UPPER SPEC LIMIT TARGET VALUE UPPER SPEC LIMIT 38.4 .0328 .0345 .0362 1.38 1.52 24.3 .0378 .0395 .0412 1.98 2.13 15.1 .0438 .0455 .0472 2.90 3.06 .0523 .0540 .0557 4.38 4.57 5.79 .0616 .0635 .0654 6.59 6.90 4.52 .0690 .0710 .0730 8.37 8.70 .0674 2.88 .0838 .0860 .0882 12.88 13.33 .0865 1.90 .1020 .1047 .1074 19.73 20.30 1.19 55PC0212-10-* 10 37 x 26 .1050 .1070 .1090 .1252 .1290 .1328 31.12 32.13 55PC0212-8-* 8 133 x 29 .158 .163 .169 .658 .188 .196 .203 56.8 59.9 55PC0212-6-* 6 133 x 27 .198 .205 .212 .418 .233 .242 .251 89.7 94.7 55PC0212-4-* 4 133 x 25 .250 .260 .268 .264 .300 .311 .322 146. 154. 55PC0212-2-* 2 665 x 30 .320 .330 .340 .170 .370 .383 .397 227. 240. 55PC0212-1-* 1 817 x 30 .360 .370 .380 .139 .410 .424 .438 278. 291. 55PC0212-0-* 0 1045 x 30 .395 .415 .425 .108 .449 .466 .483 343. 366. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. Page 1 of 2 DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Raychem Wire & Cable 501 Oakside Avenue Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 (c) 2013 Tyco Electronics Corporation,. All rights reserved. Page SPECIFICATION CONTROL DRAWING Revision 2 of 2 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 200C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level COLOR: White preferred CROSSLINK VERIFICATION: 300 3C for 1 hour IDENTIFICATION AND COLOR STRIPING DURABILITY: 125 cycles (250 strokes) (minimum), 500 g weight INSULATION ELONGATION AND TENSILE STRENGTH: Total Insulation, Elongation, 50% (minimum) Tensile Strength, 5000 lbf/in (minimum) INSULATION FLAWS: Spark Test, 3.0 kV (rms) Impulse Dielectric Test, 8.0 kV (peak) INSULATION THICKNESS: .008 in. (nominal) total insulation SHRINKAGE: 230 3C for 1 hour, 0.125 inch (maximum) in 12 inches VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms) PART NUMBER: The "*" in the part numbers on page 1 shall be replaced by a color code designator. 1/ Example: AWG 22, white: 55PC0212-22-9 AWG 22, white with a black stripe: 55PC0212-22-90 1/ See footer section on page 1 D SCD 55PC0212