Features
·Universal AC input / full range
·Built-in active PFC function
·Short circuit, over load, over voltage, over
temperature protected
·Built-in cooling fan speed control
·Built-in constant current limiting circuit
·Low profile: 33mm thickness
·Built-in fan speed control
·Remote on/off control (Optional)
·LED indicator for power on
·100% full load burn-in test
·Fixed switching frequency at PFC:67KHz
PWM:134KHz
·3 year warranty
•
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258
VSP-200-12 Single Output with PFC Function
DC output voltage 12V
Output V. tolerance ±2%
Output rated current 16.7A
Output current range 0-16.7A
Ripple & noise 100mV
Line regulation ±0.5%
Load regulation ±0.5%
DC output power 200.4W
Efficiency 79%
DC voltage adj. +10, -5%
Input voltage range 85~264VAC 47~63Hz 120~370VDC
AC current 2.8A/115V 1.4A/230V 3.3V: 2A/115V 1.0A/230V
Inrush current cold start 40A/230V
Leakage current <2mA/240VAC
Overload protection 105%~150%
type: constant current limiting, auto recovery
Over voltage protection 105%~135% type: shutdown reset: re-power on
Over temp. protection 95ºC±5ºC (TSW1) type: shutdown reset: auto recovery
Remote control (option) CN1: 3 ~15VDC Power on, <1VDC Power off
Temperature coefficient ±0.05% / °C (0~50°C)
Set up, rise, hold up time 600ms, 60ms, 20ms
Vibration 10~500Hz, 2G 10min./1cycle (1 hour each axes)
Power factor PF>0.93/230VAC, PF>0.98/115VAC
Withstand voltage I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms min.
Working temp., humidity -10°C~+60% (refer to output derating curve), 20%-90% RH
Storage temp., humidity -20ºC~+85ºC, 10%~95% RH
Dimensions 7.83x3.90x1.97 inches (199x99x50 mm)
Weight 1.76 lbs (0.8 Kg)
Safety standards UL1950, TUV EN60950, S-Mark approved
EMC standards CISPR22 (EN55022) CLASS B, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-3-2,-3
Notes: 1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise cus-
tomers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for cus-
tomer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s pub-
lished specifications. Nothing will be covered outside of standard product warranty.
•
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258
VSP-200-12 Single Output with PFC Function
Block Diagram
Output Derating Static Characteristics
Dimensions (mm)