1
MURB1020CTPbF
MURB1020CT-1PbF
Bulletin PD-21081 08/05
trr = 25ns
IF(AV) = 10Amp
VR = 200V
Ultrafast Recovery Time
Low Forward Voltage Drop
Low Leakage Current
175°C Operating Junction Temperature
Lead-Free ("PbF" suffix)
Features
Description/ Applications
International Rectifier's MUR.. series are the state of the art Ultra fast recovery rectifiers specifically designed with
optimized performance of forward voltage drop and ultra fast recovery time.
The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness
and reliability characteristics.
These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as
free-wheeling diode in low voltage inverters and chopper motor drives.
Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.
Absolute Maximum Ratings
Ultrafast Rectifier
VRRM Peak Repetitive Peak Reverse Voltage 200 V
IF(AV) Average Rectified Forward Current Per Leg 5 A
Total Device, (Rated VR ), TC = 149°C Total Device 10
IFSM Non Repetitive Peak Surge Current Per Leg 50
IFM Peak Repetitive Forward Current Per Leg 10
(Rated VR , Square wave, 20 KHz), TC = 149°C
TJ, TSTG Operating Junction and Storage Temperatures - 65 to 175 °C
Parameters Max Units
www.irf.com
MURB1020CTPbF
Case Styles
MURB1020CT-1PbF
TO-262
D2PAK
2
BASE
COMMON
CATHODE
123
ANODE
COMMON
CATHODE
A
NODE
12
2
BASE
COMMON
CATHODE
123
ANODE
COMMON
CATHODE
A
NODE
12
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
2www.irf.com
VBR, VrBreakdown Voltage, 200 - - V IR = 100µA
Blocking Voltage
VFForward Voltage - 0.87 0.99 V IF = 5A, TJ = 125°C
- 1.02 1.20 V IF = 10A, TJ = 125°C
- 1.12 1.25 V IF = 10A, TJ = 25°C
IRReverse Leakage Current - - 10 µA VR = VR Rated
- - 250 µA TJ = 150°C, VR = VR Rated
CTJunction Capacitance - 8 - pF VR = 200V
LSSeries Inductance - 8.0 - nH .
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters Min Typ Max Units Test Conditions
Measured lead to lead 5mm from package body
trr Reverse Recovery Time - - 35 ns IF = 1.0A, diF/dt = 50A/µs, VR = 30V
--25 I
F = 0.5A, IR = 1.0A, IREC = 0.25A
-24- T
J = 25°C
35 TJ = 125°C
IRRM Peak Recovery Current - 3.3 - A TJ = 25°C
- 5.0 - TJ = 125°C
Qrr Reverse Recovery Charge - 33 - nC TJ = 25°C
-76- T
J = 125°C
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
IF = 5A
VR = 160V
diF /dt = 200A/µs
Parameters Min Typ Max Units Test Conditions
Parameters Min Typ Max Units
TJMax. Junction Temperature Range - 65 - 175 °C
TStg Max. Storage Temperature Range - 65 - 175
RthJC Thermal Resistance, Junction to Case Per Leg - - 5 °C/W
RthJA Thermal Resistance, Junction to Ambient Per Leg - - 50
RthCS Thermal Resistance, Case to Heatsink - 0.5 -
Wt Weight - 2.0 - g
- 0.07 - (oz)
Mounting Torque 6.0 - 12 Kg-cm
5.0 - 10 lbf.in
Marking Device MURB1020CT Case style D2Pak
MURB1020CT-1 Case style TO-262
Thermal - Mechanical Characteristics
c Mounting Surface, Flat, Smooth and Greased
c
Bulletin PD-21081 08/05
3
MURB1020CTPbF, MURB1020CT-1PbF
www.irf.com
Fig. 2 - Typical Values Of Reverse Current
Vs. Reverse Voltage
Fig. 1 - Typical Forward Voltage Drop Characteristics
Reverse Voltage - VR (V)
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
Forward Voltage Drop - VFM (V)
Instantaneous Forward Current - I F
(A)
Reverse Current - I R
(µA)
Reverse Voltage - VR (V)
Junction Capacitance - C T (pF)
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
t1, Rectangular Pulse Duration (Seconds)
Thermal Impedance Z thJC (°C/W)
0.0001
0.001
0.01
0.1
1
10
100
0 40 80 120 160 200
125˚C
100˚C
25˚C
T = 175˚C
150˚C
J
1
10
100
1 10 100 1000
T = 25˚C
J
0.1
1
10
100
0.2 0.4 0.6 0.8 1 1.2 1.4 1.
6
T = 175˚C
T = 125˚C
T = 25˚C
J
J
J
0.01
0.1
1
10
0.00001 0.0001 0.001 0.01 0.1 1
Single Pulse
(Thermal Resistance)
D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01
2
t
1
t
P
DM
Notes:
1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
4www.irf.com
(2) Formula used: TC = TJ - (Pd + PdREV) x RthJC
;
Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1
= rated VR
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current
Fig. 6 - Forward Power Loss Characteristics
Average Power Loss ( Watts )
trr ( ns )
Qrr ( nC )
Average Forward Current - IF(AV) (A)
Allowable Case Temperature (°C)
Average Forward Current - IF(AV)
(A)
Fig. 8 - Typical Stored Charge vs. di F /dt
Fig. 7 - Typical Reverse Recovery vs. di F /dt
di
F /dt (A/µs )
di F
/dt (A/µs )
0
1
2
3
4
5
6
7
012345678
DC
RMS Limit
D = 0.01
D = 0.02
D = 0.05
D = 0.1
D = 0.2
D = 0.5
10
20
30
40
50
100 1000
I
F
= 10 A
I
F
= 5 A
V = 160V
T = 125˚C
T = 25˚C
R
J
J
0
20
40
60
80
100
120
140
160
100 1000
I
F
= 10 A
I
F
= 5 A
V = 160V
T = 125˚C
T = 25˚C
R
J
J
130
140
150
160
170
180
02468
DC
Square wave (D = 0.50)
Rated Vr applied
see note (2)
Bulletin PD-21081 08/05
5
MURB1020CTPbF, MURB1020CT-1PbF
www.irf.com
Fig. 10 - Reverse Recovery Waveform and Definitions
IRFP250
D.U.T.
L = 70µH
V = 200V
R
0.01
G
D
S
dif/dt
ADJUST
t
a
t
b
t
rr
Q
rr
I
F
I
RRM
I
RRM
0.5
di(rec)M/dt
0.75 I
RRM
5
4
3
2
0
1
di /dt
f
Fig. 9- Reverse Recovery Parameter Test Circuit
Reverse Recovery Circuit
di F /dt
di F /dt
4. Qrr - Area under curve defined by t rr
and IRRM
5. di (rec) M / dt - Peak rate of change of
current during t b portion of t rr
1. diF/dt - Rate of change of current through zero
crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured from zero
crossing point of negative going IF to point where
a line passing through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
Q rr = t rr x I RRM
2
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
6www.irf.com
Conform to JEDEC outline D2Pak (SMD-220)
Dimensions in millimeters and (inches)
Outlines Table
Modified JEDEC outline TO-262
Dimensions in millimeters and (inches)
NC
2
BASE
COMMON
CATHODE
123
ANODE
COMMON
CATHODE
A
NODE
12
2
BASE
COMMON
CATHODE
123
ANODE
COMMON
CATHODE
A
NODE
12
Bulletin PD-21081 08/05
7
MURB1020CTPbF, MURB1020CT-1PbF
www.irf.com
MURB1020CT
THIS IS A MURB1020CT
ASSEMBLED ON WW 02, 2000
LOT CODE 8024 LOGO
LOT CODE
ASSEMBLY
RECTIFIER
INTERNATIONAL
P = LEAD-FREE
WEEK 02
YEAR 0 = 2000
DATE CODE
PART NUMBER
Part Marking Information
D2PAK
TO-262
MURB1020CT-1
THIS IS A MURB1020CT-1
ASSEMBLED ON WW 02, 2000
LOT CODE 8024 LOGO
LOT CODE
ASSEMBLY
RECTIFIER
INTERNATIONAL
P = LEAD-FREE
WEEK 02
YEAR 0 = 2000
DATE CODE
PART NUMBER
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
8www.irf.com
TRR
FEED DIRECTION
TRL
FEED DIRECTION
10 .90 (0.429)
10 .70 (0.421) 16 .10 (0.634)
15 .90 (0.626)
1.75 (0 .069)
1.25 (0 .049)
1.85 (0.073)
1.65 (0.065)
4.10 (0.161)
3.90 (0.153)
1.60 (0.063)
1.50 (0.059)
DIA.
1.60 (0.063)
1.50 (0.059)
DIA.
11.60 (0.4 57)
11.40 (0.4 49)
15.42 (0.609)
15.22 (0.601)
4.72 (0.186)
4.52 (0.178)
24 .30 (0.95 7)
23 .90 (0.94 1)
0.368 (0.0145)
0.342 (0.0135)
360 (14.173)
DIA. MAX.
26 .40 (1.039)
24 .40 (0.961)
13.50 (0.532)
12.80 (0.504) DIA.
60 (2 .362)
DIA. MIN.
SMD-220 Tape & Reel
When ordering, indic ate the part
number, part orientation, and the
quantity. Quantities are in multiples
of 800 p ieces p er reel fo r bo th
TRL and TRR.
Dimensions in millimeters and (inches)
Tape & Reel Information
Bulletin PD-21081 08/05
9
MURB1020CTPbF, MURB1020CT-1PbF
www.irf.com
Device Code
15
24
3
1- Ultrafast MUR Series
2-B = D
2Pak/ TO-262
3- Current Rating (10 = 10A)
4- Voltage Rating (20 = 200V)
5- CT = Center Tap (Dual) TO-220 /D2PAK/ TO-262
6- -1 = TO-262
7-y none = Tube (50 pieces)
6y TRL = Tape & Reel (Left Oriented, for D2PAk package)
y TRR = Tape & Reel (Right Oriented, for D2PAk package)
8-y none = Standard Production
y PbF = Lead-Free
MUR B 10 20 CT -1 TRL PbF
6
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 08/05
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level and Lead-Free.
Qualification Standards can be found on IR's Web site.
Ordering Information Table
78