www.recom-power.com REV.: 3/2019 ECO-1
Features
Unregulated
Converters
3 Watt in a SIP4 package
1kVDC/1s, 2kVDC/1s or 3kVDC/1s isolation
Efficiency up to 90%
-40°C to +100°C operating temperature range
IEC/EN/UL60950 certified
CB Report
Industry standard pinout
RI3
Description
The RI3 series has been specifically designed for applications where board space is at a premium since
these 3 Watt converters have the same foot print as the RI series 2 Watt converters. With efficiencies
up to 90%, the full output power is available over the operating temperature range -40°C to +85°C and
the converters can be used in ambient temperatures of up to 100°C with derating. The wide selection
of input voltage and output voltage options plus an I/O-Isolation of 1kVDC, 2kVDC or 3kVDC makes
these converters suitable for many industrial applications.
DC/DC Converter
3 Watt
SIP4
Single Output
UL60950-1 certified
CAN/CSA-C22.2 No 60950-1 certified
EN60950-1 certified
IEC60950-1 certified
EN55032 compliant
CB report
E224736
Selection Guide
Part Input Output Output Efficiency max. Capacitive
Number Voltage Voltage Current typ. @ full load Load (1)
[VDC] [VDC] [mA] [%] [µF]
RI3-0505S 5 5 600 83 2200
RI3-0509S 5 9 333 86 1200
RI3-0512S 5 12 250 87 1000
RI3-0515S 5 15 200 88 820
RI3-1205S 12 5 600 85 2000
RI3-1209S 12 9 333 88 1200
RI3-1212S 12 12 250 89 1000
RI3-1215S 12 15 200 89 820
RI3-1505S 15 5 600 85 2000
RI3-1509S 15 9 333 88 1200
RI3-1512S 15 12 250 88 1000
RI3-1515S 15 15 200 88 820
RI3-2405S 24 5 600 86 2000
RI3-2409S 24 9 333 89 1200
RI3-2412S 24 12 250 90 1000
RI3-2415S 24 15 200 90 820
Model Numbering
Isolation (2)
Single
Input Voltage
Output Voltage
RI3-__ __ _/_
Notes:
Note2: add suffix “/H2” for 2kVDC/1second or “/H3” for 3kVDC/1second isolation
without suffix standard 1kVDC/1second isolation
Notes:
Note1: Max. capacitive load is tested at nominal input and constant resistive load
Ordering Examples:
RI3-1212S = 12VDC Input Voltage, 12VDC Output Voltage, Single Output, 1kVDC/1s isolation
RI3-2405S/H2 = 24VDC Input Voltage, 5VDC Output Voltage, Single Output, 2kVDC/1s isolation
RI3-0505S/H3 = 5VDC Input Voltage, 5VDC Output Voltage, Single Output, 3kVDC/1s isolation
www.recom-power.com REV.: 3/2019 ECO-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RI3
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range nom. Vin=
5VDC
12VDC
15VDC
24VDC
4.5VDC
10.8VDC
13.5VDC
21.6VDC
5VDC
12VDC
15VDC
24VDC
5.5VDC
13.2VDC
16.5VDC
26.4VDC
Internal Operating Frequency 20kHz 40kHz
Minimum Load 0%
Output Ripple and Noise (3) 20MHz BW 50mVp-p 100mVp-p
Efficiency vs. Load
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
1205
1209
1212
1215
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
2405
2409
2412
2415
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0505
0509
0512
0515
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
1505
1509
1512
1515
Notes:
Note3: Measurements are made with a 100nF MLCC across output (low ESR)
RI3-15xxS
RI3-05xxS
RI3-24xxS
RI3-12xxS
www.recom-power.com REV.: 3/2019 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RI3
Series
REGULATIONS
Parameter Condition Values
Output Accuracy 5Vout
all other
±3.0% min. / ±4.0% typ.
±2.0% min. / ±3.0% typ.
Line Regulation low line to high line ±1.2% of 1.0% Vin typ.
Load Regulation (4) 10% to 100% load 5Vout
all other
±8.0% typ. / ±10.0% max.
±6.0% typ. / ±10.0% max.
RI3-xx05S
RI3-xx12S
RI3-xx09S
RI3-xx15S
PROTECTIONS
Parameter Condition Value
Isolation Voltage tested for 1 second
standard without suffix
with suffix “/H2”
with suffix “/H3”
1kVDC
2kVDC
3kVDC
Isolation Capacitance 37pF typ. / 130pF max.
Isolation Resistance 10G min.
30
20
10
0
25
15
5
-5
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0509
1209
1509
2409
30
20
10
0
25
15
5
-5
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0515
1215
1515
2415
30
20
10
0
25
15
5
-5
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0505
1205
1505
2405
30
20
10
0
25
15
5
-5
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0512
1212
1512
2412
Deviation vs. Load
Notes:
Note4: Operation below 10% load will not harm the converter, but specifications may not be met
www.recom-power.com REV.: 3/2019 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RI3
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range without derating @ natural convection 0.1m/s (see graph) -40°C to +85°C
Maximum Case Temperature +115°C
Operating Humidity non-condensing 5% - 95% RH max.
Vibration MIL-STD-202G
MTBF according to MIL-HDBK-217F, G.B. +25°C
+85°C
4395 x 103 hours
1740 x 10³ hours
Derating Graph
(@ Chamber and natural convection 0.1m/s)
-40 -20 0 20 40 7060-30 -10 10 30 50 80
85
90 110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment - General Requirements for Safety
(CB Scheme) E224736-A31-CB-1 IEC60950-1:2005, 2nd Edition + AM2:2013
EN60950-1, 2nd Edition, 2013
Information Technology Equipment - General Requirements for Safety E224736-A32-UL UL60950-1, 2nd Edition, 2014
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014
EAC RU-AT.49.09571 TP TC 004/2011
RoHS 2+ RoHS-2011/65/EU + AM-2015/863
EMC Compliance Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment -
Emission requirements
with external filter
(see filter suggestion below)
EN55032, Class B
EN55032, Class A
continued on next page
L1
C
1
C
2
-Vout
+Vout
-Vin
+Vin
C4
C3
+Vout
+Vin
-Vout
-Vin
EMC Filter Suggestion according to EN55032
www.recom-power.com REV.: 3/2019 ECO-5
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RI3
Series
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter Type Value
Material case
potting
non-conductive plastic, (UL94 V-0)
silicone, (UL94 V-0)
Dimension (LxWxH) 11.5 x 7.6 x 10.2mm
Weight 2.2g typ.
Dimension Drawing (mm)
Recommended Footprint
Standard H2 Version
Recommended Footprint
Standard H3 Version
0.85Ø
1.80
1.00
Top View
0.51
1.27 10.2
0.75+0.10/-0.05
7.6
Marking
1.00 Ø +0.15/-0
11.5
7.622.00
2.54
2.54
Top View
0.85Ø +0.15/-0
2.54
2.54
4.10
0.25
±0.05
Bottom View
1 2 3 4 1 2 3 4 1 2 3 4
embossed logo
solder pad for /H3 models
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 520.0 x 16.5 x 9.0mm
Packaging Quantity tube 42pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity non-condensing 95% RH max.
Pinning information
Pin # Single
1 -Vin
2 +Vin
3 -Vout
4 +Vout
Tolerance:
xx.x= ±0.5mm
xx.xx= ±0.25mm
Component List Class A Component List Class B
MODEL C1 L1 C3 (safety) C4 (safety)
RI3-0505S 10µF
100V MLCC
5.6µH choke
RLS-567 470pF 330pFRI3-2405S
RI3-2415S
MODEL C1 L1 C2
RI3-0505S
N/A N/A
22µF, 16V MLCC
RI3-2405S
10µF, 100V MLCC
RI3-2412S
Notes:
Note5: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice