10Gbps 300m Duplex LC XFP Transceiver
PXP96-8503M
Primus IT Limited
Page 4
Notes:
1. The optical power is launched into 50/125µm MMF.
2. Measured with a PRBS 231-1 test pattern @10.3125Gbps.
3. Unfiltered, 20-80%. Measured with a PRBS 231-1 test pattern @10.3125Gbps.
4. Measured with a PRBS 231-1 test pattern @10.3125Gbps, ER=5.5dB, BER <10-12.
Timing Characteristics
Digital Diagnostic Monitor Characteristics (DDM)
The following digital diagnostic characteristics are defined over the Recommended Operating Environment unless
otherwise specified. It is compliant to SFF8077i with internal calibration mode. For external calibration mode
please contact our sales stuff.
Temperature Monitor Absolute Error
Laser Power Monitor Absolute Error
RX Power Monitor Absolute Error
Supply Voltage Monitor Absolute Error
Bias Current Monitor Absolute Error
Digital Diagnostic Memory Map (Compliant with SFF-8077i)
The transceivers provide serial ID memory contents and diagnostic information about the present operating
conditions by the 2-wire serial interface (SCL, SDA).
The diagnostic information with internal calibration or external calibration all are implemented, including received
power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and
temperature monitoring.
The digital diagnostic memory map specific data field defines as following (For further information, please refer to
SFF-8077i).