E3X-DA-S Digital Fiber Sensors 1
Digital Fiber Sensors
E3X-DA-S
The next-generation platform
for a wide range of sensing
The indust ry's first Pow er Tuning func tion in a digital
amplifier.
Large, easy-to-read displa ys that are clear even from
a distance. Seven convenient display formats.
Stable long-term performance achieved with
OMR ON's APC function .
A wide arr ay of adv anced funct ions f or ev en more ap-
plications.
The same ease-of-use as the E3X-DA-N Amplifiers.
Environmentally friendly design.
Improved Mobile Console.
Ordering Information
Amplifier Units
Amplifier Units with Cables
Amplifier Units with Connectors
Amplifier Unit Connectors (Order Separately)
Item Appearance Functions Model
NPN output PNP output
Standard models --- E3X-DA11-S E3X-DA41-S
Mark-detecting
models Green LED --- E3X-DAG11-S E3X-DAG41-S
Blue LED --- E3X-DAB11-S E3X-DAB41-S
Advanced
models Twin-output
models Area output, self-diagnosis,
differential operation E3X-DA11TW-S E3X-DA41TW-S
Exter nal-input
models Remote setting, counter, dif-
ferential operation E3X-DA11RM-S E3X-DA41RM-S
Item Appearance Functions Model
NPN output PNP output
Standard models --- E3X-DA6-S E3X-DA8-S
Mark-detecting
models Green LED --- E3X-DAG6-S E3X-DAG8-S
Blue LED --- E3X-DAB6-S E3X-DAB8-S
Advanced
models Twin-output
models Area output, self-diagnosis,
differential operation E3X-DA6TW-S E3X-DA8TW-S
Exter nal-input
models Remote setting, counter, dif-
ferential operation E3X-DA6RM-S E3X-DA8RM-S
Item Appearance Cable length No. of conductors Model
Master Connector 2 m 3 E3X-CN11
4 E3X-CN21
Slave Connector 1 E3X-CN12
2 E3X-CN22
2E3X-DA-S Digital Fiber Sen so rs
Combining Amplifier Units and Connectors
Amplifier Units and Connectors are sold separately. Refer to the following tab les when placing an order .
Whe n Usin g 5 A m plifier Uni t s
Mobile Console (O rder Separately)
Note:Use the E3X-MC11-S Mobile Console for the E3X-DA-S-series Amplifier Units. Other Mobile Consoles cannot be used.
Accessories (Order Separately)
Mounting Bracket
End Plate
Amplifier Unit Applicable Connector (Order Separately)
Model NP N output PNP ou tput Master Connector Slave Connector
Standard models E3X-DA6-S E3X-DA8-S E3X-CN11 (3-wire) E3X-CN12 (1-wire)
Mark-detecting
models E3X-DAG6-S E3X-DAG8-S +
E3X-DAB6-S E3X-DAB8-S
Advanced models E3X-DA6TW-S E3X-DA8TW-S E3X-CN21 (4-wire) E3X-CN22 (2-wire)
E3X-DA6RM-S E3X-DA8RM-S
Amplifier Units (5 Units) +1 Master Connector + 4 Slave Connectors
Appearance Model Remarks
E3X-MC11-S
(model number of set) Mobile Console with Head, Ca-
ble, and AC adapter provided as
accessories
E3X-MC11-C1-S Mobile Console
E3X-MC11-H1 Head
E39-Z12-1 Cable (1.5 m)
Appearance Model Quantity
E39-L143 1
Appearance Model Quantity
PFP-M 1
E3X-DA-S Digital Fiber Sensors 3
Specifications
Ratings/Characteristics
Amplifier Units
Amplifier Units with Cables
Type St andard m od-
els Mark-detecti ng mod els Adv a nce d, twin-
output models Advanced, external-
input mode ls
Model NPN output E3X-DA11-S E3X-DAG11-S E3X-DAB11-S E3X-DA11TW-S E3X-DA11RM-S
Item PNP output E3X-DA41-S E3X-DAG41-S E3X-DAB41-S E3X-DA41TW-S E3X-DA41RM-S
Light source (wavelength) Red LED
(650 nm) Green LED
(525 nm) Blue LED
(470 nm) Red LED (650 nm)
Supply voltage 12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption 960 mW max.
(current consumption:
40 mA max. at power supply voltage of 24 VDC)
1,080 mW max.
(current consumption: 45 mA max. at power
supply voltage of 24 VDC)
Control output Load power supply voltage: 26.4 VDC; NPN/PNP open collector ;
load current: 50 mA max.; residual voltage: 1 V max.
Circuit protection Reverse polarity for power supply connection, output short-circuit
Response
time Super-
high-
speed
mode
NPN 48 ms for operation and
50 ms for reset 80 ms for operation
and reset respective-
ly
48 ms for operation
and 50 ms for reset*1
PNP 53 ms for operati on and
55 ms for reset 53 ms for operation
and 55 ms for reset*1
Standard mode 1 ms for operation and reset respectively
High-resolution mode 4 ms for operation and reset respectively
Sensitivity setting Teaching or manual method
Functions Power tuning Light emission pow er and reception gain, digital control method
Diff erential detection --- Switchable between single edge and double
edge detection mode
Single edge: Can be set to 250 ms, 500 ms, 1
ms, 10 ms, or 100 ms.
Double edge: Can be set to 500 ms, 1 ms, 2
ms, 20 ms, or 200 ms.
Timer function Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10- ms increm ents,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Automatic power control
(APC) High-speed control method for emission current
Zero-reset Displa y can be reset to zero when required (negative values can be displayed).
Initial reset Settings can be returned to defaults as required.
Mutual interference
prevention Pos sible fo r up to 10 Units*2, *3
Counter --- Switchable between
up counter and down
counter.
Set count: 0 to
9,999,999
I/O settings --- Output setting (Se-
lect from channel 2
output, area output,
or self-diagnosis.)
External input setting
(Select from teaching,
power tuning, zero re-
set, light OFF, or
counter reset.)
Display Operation indicator (orange), Power Tu ning indicator (or-
ange) Operation indicator
for channel 1 (or-
ange), Operation in-
dicator for channel 2
(orange)
Operation indicator
(orange), Power Tun-
ing indicator (orange)
Digital display Select from the followi ng: Incident lev el + threshold, incident lev el percentage +
threshold, incident light peak le vel + no incident light bottom lev el, minimum in-
cident light peak le vel + maximum no incident light bottom lev el, long bar display,
incident level + peak hold, incident level + channel
Select from same dis-
plays as given at the
left or a counter dis-
play.
Display orientation Switching between normal/rever sed display is possible.
4E3X-DA-S Digital Fiber Sensors
*1: When counter is enabled: 80 ms for operation and reset respectively.
*2: Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual
interference prevention and the Mobile Console will not function.
*3: Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
Amplifier Units with Connectors
(Specifications different to those for Amplifier Units with cables)
Amplifier Unit Connectors
Mobile Console
Ambient illumination
(receiver side) Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Ambient temperature Operating: Groups of 1 to 2 Amplifiers: -25°C to 55°C
Groups of 3 to 10 Amplifiers: -25°C to 50°C
Groups of 11 to 16 Amplifiers: -25°C to 45°C
(with no icing or condensation)
Storage: -30°C to 70°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 MW min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance (destruction) 500 m/s2, for 3 times each in X, Y and Z directions
Enclosure rating IEC 60529 IP50 (with Protective Cover attached)
Connection method Prewired
cable
Weight (packed state) Approx. 100 g
Materials Case Polybutylene terephthalate (PBT)
Cover Polycarbon ate (PC)
Accessories Instruction sheet
Type Standard mod-
els Mark-detecting models Advance d, twin -
output models Advan ced, external-
input mo de ls
Model NPN output E3X-DA11-S E3X-DAG11-S E3X-DAB11-S E3X-DA11TW-S E3X-DA11RM-S
Item PNP output E3X-DA41-S E3X-DAG41-S E3X-DAB41-S E3X-DA41TW-S E3X-DA41RM-S
Type Standard mod-
els Mark-detecting models Advance d, twin -
output models Advan ced, external-
input mo de ls
Model NPN output E3X-DA6-S E3X-DAG6-S E3X-DAB6-S E3X-DA6TW-S E3X-DA6RM-S
Item PNP output E3X-DA8-S E3X-DAG8-S E3X-DAB8-S E3X-DA8TW-S E3X-DA8RM-S
Connection method Standard connector
Weight (packed state) Approx. 55 g
Item E3X-CN11/21/22 E3X-CN12
Rated current 2.5 A
Rated voltage 50 V
Contact resistance 20 mW max. (20 mVDC max., 100 mA max.)
(The figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance
of the cable.)
No. of insertions
(destruction) 50 times
(The figure for the number of insertions is for connection to the Amplifier Unit and the adjacent Connector.)
Materials Housing Polybutylene terephthalate (PBT)
Contacts Phosphor bronze/gold-plated nickel
Weight (packed state) Approx. 55 g Approx. 25 g
Item E3X-MC11-S
Supply voltage Charged with AC adapter
Connection method Connected via adapter
Weight (packed state) Approx. 580 g (Console only: 120 g)
Refer to Operation Manual provided with the Mobile Console for de-
tails.
E3X-DA-S Digital Fiber Sensors 5
Ordering Information: Fiber Units
Through-beam Fiber Units
Note 1. Indicates models that allow free cutting. Models without this mark do not allow free cutting.
2. The size of standard sensing object is t he same as the fiber core diameter (lens diameter f or models with lens).
3. The values f or the minimum sensing object are representative v al ues that indicate values obtained in standard mode with the sensing dis-
tance and sensitivity set to optimum values.
Long-distance Fiber Units
*1: The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
*2: The optical fiber for the E32-T17L is 10 m long on each side, so the value is 20,000 mm
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble be n d-
ing radius
M4 E3X-DA@-S 1.4-mm dia.
(0.01-mm dia.) E32-T11L 25 mm
E3X-DAG@-S
E3X-DAB@-S
3-mm dia. E3X-D A@-S E32-T12L
M3 E3X-DA@-S 0.9-mm dia.
(0.005-mm dia.) E32-T21L 10 mm
2-mm dia.; small di-
ameter
E3X-DA@-S E32-T22L
M14; with lens; ide-
al for explosion-
proof applications
E3X-DA@-S 10-mm dia. E32-T17L 25 mm
: High-resolution mode : Super-high-speed mode: Standard mode
M4 screw
350 (840)
1,700 (4,000)*1
1,330 (3,200)
75
120
150
3-mm dia. 350
1,700
1,330
M3 screw
540
440
100
2-mm dia.
540
440
100
M14 screw
20,000*2
20,000*2
4,000*2
Conventional Fiber Flexible Fiber
Conventional fiber uses just one core and
one cladding section. Bending the fiber
may break it or reduce the light intensity.
Flexible fiber contains multiple independent cores
all surrounded by cladding. The fiber can be bent
without breaking or reducing the light intensity.
Core
Cladding
Flexible fiber models are indicated by an
"R" at the end of the model number.
Flexible fiber contains multiple cores.
These cores are all surrounded by cladding,
giving a minimum bending radius of 1 mm.
The fiber can be bent at right angles without
affecting the light intensity. Handle it just like
any other cable.
A Wide Range of Flexible Fibers for Easy Installation without Loss of Light Intensity
6E3X-DA-S Digital Fiber Sensors
General-purpose Fiber Units
*The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Fiber Units with Thin Heads
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble bend-
ing radius
M4 E3X-DA@-S 1.0-mm dia.
(0.005-mm dia.) E32-TC200 25 mm
E3X-DAG@-S
E3X-DAB@-S
M4 E3X-DA@-S E32-T11R 1 mm
M4
Fiber sheath mate-
rial: fluororesin
E3X-DA@-S E32-T11U 4 mm
3-mm dia. E3X-DA@-S E32-T12R 1 mm
M3
Possible to mount
the E39-F5 Reflec-
tive Side-view Con-
version Attachment
E3X-DA@-S E32-TC200A 25 mm
M3; for detecting
minute sensing ob-
jects
E3X-DA@-S 0.5-mm dia.
(0.005-mm dia.) E32-TC200E 10 mm
E3X-DAG@-S
E3X-DAB@-S
M3 E3X-DA@-S E32-T21R 1 mm
M4 screw
760 (4,000)*
200 (1,500)
1,000 (4,000)*
75 (550)
100 (700)
45 (350)
M4 screw 140 (970) 530 (3,700)
700 (4,000)*
M4 screw 180 (930)
900 (4,000)*
680 (3,600)
3-mm dia. 140 530 700
M3 screw 180 680900
M3 screw
50 220
270
12
20
25
M3 screw 130
160
30
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble bend-
ing radius
2-mm dia.; for de-
tecting minute
sensing objects
E3X-DA@-S 0.5-mm dia.
(0.005-mm dia.) E32-T22 10 mm
2-mm dia.; for de-
tecting minute
sensing objects
E3X-DA@-S E32-T22R 1 mm
1.2-mm dia.; with
sleeve
E3X-DA@-S 1.0-mm dia.
(0.005-mm dia.) E32-TC200B
E32-TC200B4 25 mm
E3X-DAG@-S
E3X-DAB@-S
0.9-mm dia.; with
sleeve
E3X-DA@-S 0.5-mm dia.
(0.005-mm dia.) E32-TC200F
E32-TC200F4 10 mm
2-mm dia. 50 220
270
2-mm dia. 130
160
30
1.2-mm dia.
M4 screw
90 mm (40 mm) ( ): E32-
TC200B4 200 760
1,000
75
100
45
M3 screw 0.9-mm dia.
90 mm (40 mm) ( ): E32-
TC200F4
50 220
270
E3X-DA-S Digital Fiber Sensors 7
Flexible Fiber Units (Resists Breaking) (R4)
*The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Side-view Fiber Units
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble be n d-
ing radius
Ideal for mou nting
on moving sections
(R4)
E3X-DA@-S 1.0-mm dia.
(0.005-mm dia.) E32-T11 4 mm
E3X-DA@-S 0.5-mm dia.
(0.005-mm dia.) E32-T21
E3X-DA@-S E32-T22B
M4 screw 180 (930)
900 (4,000)*
680 (3,600)
M3 screw 45 200
240
1.5-mm dia. 45 200
240
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble be nd -
ing radius
Long distance;
space-saving
E3X-DA@-S 1.0-mm dia.
(0.005-mm dia.) E32-T14L 25 mm
E3X-DAG@-S
E3X-DAB@-S
Space-saving E3X-DA@-S E32-T14LR 1 mm
Suitable for detect-
ing minute sensing
objects; small di-
ameter
E3X-DA@-S 0.5-mm dia.
(0.005-mm dia.) E32-T24 10 mm
Suitable for detect-
ing minute sensing
objects; small di-
ameter
E3X-DA@-S E32-T24R 1 mm
Screw-mounting
type
E3X-DA@-S 4-mm dia.
(0.1-mm dia.) E32-T14 25 mm
E3X-DAG@-S
E3X-DAB@-S
3-mm dia. 120 460 600
25
40
50
3-mm dia.
50 210
270
1-mm dia.
130
160
30
1-mm dia. 60
50
10
4,500
3,400
900
160 260
320
8E3X-DA-S Digital Fiber Sen so rs
Chemical-resistant Fiber Units
*Tef lon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble bend-
ing radius
Teflon-c overed*;
round head that re-
sists water drops
E3X-DA@-S 4-mm dia.
(0.1-mm dia.) E32-T11F 4 mm
Teflon-c overed*;
withstands chemi-
cals and harsh en-
vironments
(operating ambient
temperature:
-30°C to 70°C)
E3X-DA@-S 4-mm dia.
(0.1-mm dia.) E32-T12F 40 mm
Teflon-c overed*;
withstands chemi-
cals and harsh en-
vironments; side-
view (operating am-
bient temperature:
-30°C to 70°C)
E3X-DA@-S 3-mm dia.
(0.1-mm dia.) E32-T14F
Teflon*; withstands
chemicals and
harsh environ-
ments
(operating ambient
temperature:
-40°C to 200°C)
E3X-DA@-S 1.0-mm dia.
(0.005-mm dia.) E32-T81F-S 10 mm
7.2-mm dia.
2,500
2,000
520
5-mm dia.
4,000
3,000
800
5-mm dia. 500
400
100
6-mm dia.
920
700
190
E3X-DA-S Digital Fiber Sensors 9
Heat-resistant Fiber Units
*1: For continuous operation, use the products within a temperature range of -40°C to 130°C.
*2: Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
*3: Indicates the heat-resistant temperature at the fiber tip.
*4: The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Fiber Unit with Slot Sensor
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble be nd -
ing radius
Resists 150 °C*1; fi-
ber sheath materi-
al: fluororesin
(operating ambient
temperature:
-40°C to 150°C)
E3X-DA@-S 1.5-mm dia.
(0.1-mm dia.) E32-T51 35 mm
Resists 200°C; fle x-
ible (R10); fibe r
sheath material:
Teflon*2
(operating ambient
temperature:
-40°C to 200°C)
E3X-DA@-S 1.0-mm dia.
(0.005-mm dia.) E32-T81R-S 10 mm
Resists 350 °C*3,
with spiral tube;
high mechanical
strength; fiber
sheath material:
stainless steel
(operating ambient
temperature:
-60°C to 350°C)
E3X-DA@-S E32-T61-S 25 mm
Sid e-view; resists
150°C*1; suitable
for detecting minute
sensing objects; fi-
ber sheath materi-
al: fluororesin
(operating ambient
temperature:
–40°C to 150°C)
E3X-DA@-S E32-T54 35 mm
Resists 200 °C*3; L-
shaped; fiber
sheath material:
stainless steel
E3X-DA@-S 1.7-mm dia.
(0.1-mm dia.) E32-T84S-S 25 mm
M4 screw
1,000
760
200
M4 screw
360 (2,650)
280 (2,100)
70 (520)
M4 screw
600 (4,000)*4
450 (3,400)
120 (900)
2-mm dia. 300
230
60
3-mm dia. 1,750
1,300
350
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble be n d-
ing radius
Suitable for film
sheet detection; no
optical axis adjust-
ment required;
easy to mount
E3X-DA@-S 4-mm dia.
(0.1-mm dia.) E32-G14 25 mm
E3X-DAG@-S
E3X-DAB@-S
10
10
10
10
10
10
10 E3X-DA-S Digital Fiber Sen so rs
Fiber Units with a Narrow Vision Field
Area-sensing Fiber Units
*1: These figures are for a sensing distance of 300 mm. (Figures for the diameter of sensing objects are in the still state.)
*2: These figures are ones for which detection is possible in each sensing area at a digital incident level of 1,000.
(Figures for the diameter of sensing objects are in the still state.)
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble be nd -
ing radius
Suitable for detect-
ing waf ers
E3X-DA@-S 1.7-mm dia.
(0.1-mm dia.) E32-T22S 25 mm
Side-view; suitable
f or detecting wafers
E3X-DA@-S 2-mm dia.
(0.1-mm dia.) E32-T24S 10 mm
3-mm dia.
2,500
1,900
500
3.5 × 3-mm dia. 1,750
1,300
350
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)
(Parentheses: With E39-F1 Lens
Unit)
Standard object
(min. sensing
object)
(Parentheses:
Opaque object)
Model Permissi-
ble bend-
ing radius
Multi-point detec-
tion (4-head) E3X-DA@-S 2-mm dia.
(0.1-mm dia.) E32-M21 25 mm
Detects in a 30-mm
area
E3X-DA@-S (0.3-mm dia.)*1 E32-T16W 10 mm
E3X-DA@-S E32-T16WR 1 mm
Side-view; suitable
for applications with
limited spatial
depth
E3X-DA@-S (0.2-mm dia.)*1 E32-T16J 10 mm
E3X-DA@-S E32-T16JR 1 mm
Suitable for detect-
ing ov er a 10-mm
area; long distance
E3X-DA@-S (0.6-mm dia.)*2 E32-T16 25 mm
Stable f or detecting
minute sensing ob-
jects in a wide area
E3X-DA@-S (0.2-mm dia.)*1 E32-T16P 10 mm
E3X-DA@-S E32-T16PR 1 mm
M3 screw
750
610
140
30 mm
2,300
1,800
450
30 mm
1,700
1,300
340
11 mm
1,300
1,000
260
11 mm
980
750
190
10 mm
3,700
2,800
740
11 mm
1,500
1,100
300
11 mm
1,100
840
220
E3X-DA-S Digital Fiber Sensors 11
Fiber Units with Reflective Sensors
Note 1. Indicates models that allow free cutting. Models without this mark do not allow free cutting.
2. The values f or the minimum sensing object are representative v al ues that indicate values obtained in standard mode with the sensing dis-
tance and sensitivity set to optimum values.
3. When set to the maximum sensitivity setting, internal light reflection ma y cause the sensor to detect incident light. In such case, use adjust
the threshold either manually or using teaching.
Long-distance Fiber Units
*Values are sensed for white paper (standard sensing object).
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)* Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble be n d-
ing radius
M6 E3X-DA@-S 500´500
(0.005-mm dia.) E32-D11L 25 mm
E3X-DAG@-S
E3X-DAB@-S 100´100
(0.1-mm dia.)
3-mm dia.; small di-
ameter
E3X-DA@-S 300´300
(0.005-mm dia.) E32-D12
M4 E3X-DA@-S 200´200
(0.005-mm dia.) E32-D21L 10 mm
3-mm dia.; small di-
ameter
E3X-DA@-S E32-D22L
Square head, su-
per-long distance
E3X-DA@-S 300´300 E32-D16 4 mm
M6 screw
650
400
110
44
35
22
3-mm dia.
400
230
70
M4 screw
210
130
35
3-mm dia.
210
130
35
17.5 mm
40 to 700
40 to 1,000
40 to 240
12 E3X-DA-S Digital Fiber Sen so rs
General-purpose Fiber Units
*Values are sensed for white paper (standard sensing object).
Fiber Units with Thin Heads
*Values are sensed for white paper (standard sensing object).
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)* Standard object
(min. sensing
object : Gold
wire)
Model Permissi-
ble bend-
ing radius
M6 E3X-DA@-S 400´400
(0.005-mm dia.) E32-DC200 25 mm
E3X-DAG@-S
E3X-DAB@-S 100´100
(0.1-mm dia.)
M6 E3X-DA@-S 300´300
(0.005-mm dia.) E32-D11R 1 mm
M6
Fiber sheath mate-
rial: fluororesin
E3X-DA@-S E32-D11U 4 mm
3-mm dia. E3X-DA@-S E32-D12R 1 mm
M3; small diameter E3X-DA@-S 100´100
(0.005-mm dia.) E32-DC200E 10 mm
E3X-DAG@-S
E3X-DAB@-S 25´25
(0.2-mm dia.)
M3; small diameter E3X-DA@-S 50´50
(0.005-mm dia.) E32-D21R 1 mm
3-mm dia.; small di-
ameter
E3X-DA@-S E32-D22R
M6 Screw
500
300
90
32
25
16
M6 screw
300
170
50
M6 scre
w
300
170
50
3-mm dia.
300
170
50
M3 screw
130
80
22
8
6
4
M3 screw
50
30
8
3-mm dia.
50
30
8
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)* Standard object
(min. sensing
object : Gold
wire)
Model Permissi-
ble bend-
ing radius
2.5-mm dia.; with
sleeve
E3X-DA@-S 400´400
(0.005-mm dia.) E32-DC200B
E32-DC200B4 25 mm
E3X-DAG@-S
E3X-DAB@-S 100´100
(0.1-mm dia.)
1.2-mm dia.; with
sleeve
E3X-DA@-S 100´100
(0.005-mm dia.) E32-DC200F
E32-DC200F4 10 mm
0.8-mm dia.; for de-
tecting minute
sensing objects
E3X-DA@-S 25´25
(0.005-mm dia.) E32-D33 4 mm
0.5-mm dia.; for de-
tecting very minute
sensing objects
E3X-DA@-S E32-D331
2.5-mm dia.
M6 screw
90 mm (40 mm)
( ): E32-
DC200B4
500
300
90
32
25
16
1.2-mm dia.
M3 screw
90 mm (40 mm)
( ): E32-
DC200F4 130
80
22
3-mm
dia. 0.8-mm
dia.
25
16
4
2-mm
dia. 0.5-mm
dia.
5
3
0.8
E3X-DA-S Digital Fiber Sensors 13
Flexible Fiber Units (Resists Breaking) (R4)
*Values are sensed for white paper (standard sensing object).
Coaxial Fiber Units
*Values are sensed for white paper (standard sensing object).
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)* Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble bend-
ing radius
Ideal for
mounting
on moving
sections
(R4)
E3X-DA@-S 300´300
(0.005-mm dia.) E 32-D11 4 mm
E3X-DA@-S 50´50
(0.005-mm dia.) E32-D21
E3X-DA@-S 100´100
(0.005-mm dia.) E32-D21B
E3X-DA@-S 50´50
(0.005-mm dia.) E32-D22B
M6 screw
300
170
50
M3 screw
50
30
8
M4 screw
110
70
20
1.5-mm dia.
50
30
8
Features Appe arance Applicable
Am plifie r U nit Sensing distance (mm)* Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble be n d-
ing radius
M6 coaxial; high-
precision positioning
E3X-DA@-S 500´500
(0.005-mm dia.) E32-CC200 25 mm
E3X-DAG@-S
E3X-DAB@-S 100´100
(0.1-mm dia.)
3-mm dia.; small di-
ameter; coaxial;
high-precision posi-
tioning
E3X-DA@-S 300´300
(0.005-mm dia.) E32-D32L
M3 coaxial; high-
precision positioning
E3X-DA@-S 100´100
(0.005-mm dia.) E32-C31
M3 coaxial; high-
precision positioning E3X-DA@-S 50´50
(0.005-mm dia.) E32-C41
2-mm dia. coaxial;
high-precision posi-
tioning
E3X-DA@-S E32-C42
2-mm dia. coaxial;
high-precision posi-
tioning
E3X-DA@-S 100´100
(0.005-mm dia.) E32-D32
M6 screw
500
300
90
32
25
16
3-mm dia.
250
150
45
M3 screw
120
75
22
Spot diameter
0.5-mm dia.
4.0-mm dia. max.
M3 screw
50
35
8
Spot diameter
0.1-mm dia.
0.2-mm dia.
4.0-mm dia. max.
2-mm dia.
50
35
8
Spot diameter
Adjustable in the range
0.1 to 0.6-mm dia.
2-mm dia.
120
75
22
Spot diameter
Adjustable in the range
0.5 to 1-mm dia.
14 E3X-DA-S Digital Fiber Sen so rs
Side-view Fiber Units
*Values are sensed for white paper (standard sensing object).
Chemical-resistant Fiber Units
*1: Values are sensed for white paper (standard sensing object).
*2: Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)* Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble bend-
ing radius
6-mm dia.; long dis-
tance
E3X-DA@-S 200´200
(0.005-mm dia.) E32-D14L 25 mm
6-mm dia. E3X-DA @-S 100´100
(0.005-mm dia.) E32-D14LR 1 mm
2-mm dia.; small di-
ameter; space-sav-
ing
E3X-DA@-S 50´50
(0.005-mm dia.) E32-D24 10 mm
E3X-DA@-S E32-D24R 1 mm
6-mm dia. 200
110
36
6-mm dia. 80
45
14
2-mm dia. 50
30
8
2-mm dia. 26
15
4
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)*1 Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble be nd -
ing radius
Teflon-covered*2;
withstands chemi-
cals and harsh envi-
ronments (operating
ambient tempera-
ture:
-30°C to 70°C
E3X-DA@-S 200´200
(0.005-mm dia.) E32-D12F 40 mm
6-mm dia.
160
95
30
E3X-DA-S Digital Fiber Sensors 15
Heat-resistant Fiber Units
*1: Values are sensed for white paper (standard sensing object ).
*2: For continuous operation, use the products within a temperature range of -40°C to 130°C.
*3: Indicates the heat-resistant temperature at the fiber tip.
Area-sensing Fiber Units
*Values are sensed for white paper (standard sensing object).
Retroreflective Fiber Units
*Values are sensed for white paper (standard sensing object).
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)*1 Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble be n d-
ing radius
Resists 150 °C*2; fi-
ber sheath materi-
al: fluororesin
(operating ambient
temperature:
-40°C to 150°C)
E3X-DA@-S 200´200
(0.005-mm dia.) E32-D51 35 mm
Resists 200 °C*3; fi-
ber sheath materi-
al: fluororesin
(operating ambient
temperature:
-40°C to 200°C)
E3X-DA@-S E32-D81R-S 10 mm
Resists 350 °C*3; fi-
ber sheath materi-
al: stainless steel
(operating ambient
temperature:
-60°C to 350°C)
E3X-DA@-S E32-D61-S 25 mm
Resists 400 °C*3; fi-
ber sheath materi-
al: stainless steel
(operating ambient
temperature:
-40°C to 400°C)
E3X-DA@-S 100´100
(0.005-mm dia.) E32-D73-S
M6 screw
400
230
72
M6 screw
150
90
27
M6 screw
150
90
27
M4 screw 1.25-mm
dia.
100
60
18
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)* Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble be n d-
ing radius
Side-view; detec-
tion over wide ar-
eas
E3X-DA@-S 300´300
(0.005-mm dia.) E32-D36P1 25 mm
250
150
45
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)* Standard object
(min. sensing ob-
ject: Gold wire)
Model Permissi-
ble be n d-
ing radius
Transparent object
detection
E3X-DA@-S 35-mm dia.
(0.1-mm dia.) E32-R21
+
E39-R3
(Attachment)
10 mm
Transparent object
detection (operat-
ing ambient tem-
perature: -25°C to
55°C); degree of
protection:
IEC60529 IP66
E3X-DA@-S 35-mm dia.
(0.2-mm dia.) E32-R16
+
E39-R1
(Attachment)
25 mm
M6 screw Reflector
E39-R3
10 to 250
10 to 250
10 to 250
Reflector
E39-R1
150 to 1,500
150 to 1,500
150 to 1,500
16 E3X-DA-S Digital Fiber Sen so rs
Limited-reflective Fiber Units
*Values are sensed for white paper (standard sensing object).
Features Appearance Applicable
Amplifier Unit Sensing distance (mm)* Standard object
(min. sensing ob-
ject: Gold wire)
Model Permissi-
ble be nd -
ing radius
Suitable for posi-
tioning liquid crystal
glass
E3X-DA@-S 100´100
Soda glass with re-
flection f actor of 7%
E32-L16 25 mm
Suitable for posi-
tioning liquid crystal
glass
E3X-DA@-S E32-L56E1
E32-L56E2 35 mm
Suitable for posi-
tioning liquid crystal
glass (Resists
300°C)
E3X-DA@-S E32-L66 25 mm
Liquid crystal glass,
mo untin g detec-
tion, small
E3X-DA@-S 25´25
(0.005-mm dia.) E32-L24S 10 mm
Detects waf ers and
small diff erences in
height; (operating
ambient tempera-
ture: -40°C to
105°C); degree of
protection:
IEC60529 IP50
E3X-DA@-S E32-L24L 10 mm
E3X-DA@-S E32-L25L
Detects waf ers and
small diff erences in
height; degree of
protection:
IEC60529 IP50
E3X-DA@-S E32-L25 25 mm
E3X-DA@-S E32-L25A
0 to 15
0 to 15
0 to 15
4 to 12
4 to 12
4 to 12
5 to 18
5 to 18
5 to 18
0 to 4
0 to 4
0 to 4
4±2
4±2
4±2
7.2±1.8
7.2±1.8
7.2±1.8
3.3
3.3
3.3
3.3
3.3
3.3
E3X-DA-S Digital Fiber Sensors 17
Fluid-level Detection Fiber Units
Mapping Sensors (Through-beam)
Features Appearance Applicable
Amplifier Unit Sensing distance (mm) Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble bend-
ing radius
Fluid contact type:
unbendable section
L 150 mm, 350 mm
(two types); (oper-
ating ambient tem-
perature: -40°C to
200°C)
E3X-DA@-S --- Pure water at
25°CE32-D82F1
E32-D82F2 40 mm
Tube-mounting
type ; L ight ON
when fluid is
present; minimal in-
fluence from bub-
bles and water
drops
E3X-DA@-S Applicable tube: Transparent tube
Tube diameter: 3.2, 6.4, or 9.5 mm
(Tube must be FEP or material with
equiv alent tr ansparency; recom-
mended wall thickness : 1 mm)
E32-A01 4 mm
Tube-mounting
type; light ON when
fluid is present;
minimal influence
from bubbles and
water drops
E3X-DA@-S Applicable tube: Transparent tube
Tube diameter: 6 to 13 mm
(Tube must be FEP or material with
equiv alent tr ansparency; recom-
mended wall thickness : 1 mm)
E32-A02
Tube-mounting
type; dense mount-
ing to detect lev el
diff erences of 4 mm
E3X-DA@-S Applicable tube: Transparent tube
Tube diameter: 8 to 10 mm
(Tube must be FEP or material with
equiv alent tr ansparency; recom-
mended wall thickness : 1 mm)
E32-L25T 10 mm
Tube-mounting
type; unlimited tube
diameter; minimal
influence from bub-
bles and water
drops
E3X-DA@-S Applicable tube: Transparent tube
Tube diameter: No restriction
(Tube must be FEP or material with
equiv alent tr ansparency)
E32-D36F 4 mm
L
Features Appearance Applicable
Amplifier Unit Sensing distance (mm) Standard object
(min. sensing
object: Gold
wire)
Model Permissi-
ble bend-
ing radius
Super-narrow vi-
sion field; side-
view; opening an-
gle: 1.5°; simple
adjustment
E3X-DA@-S 2-mm dia.
(0.1-mm dia.) E32-A03 1 mm
Super-narrow vi-
sion field; small;
side-view; opening
angle: 3°; simple
adjustment
E3X-DA@-S 1.2-mm dia.
(0.1-mm dia.) E32-A04 10 mm
3-mm dia. 1,150
890
250
2-mm dia. 460
340
100
18 E3X-DA-S Digital Fiber Sen so rs
Output Circuits
NPN Output
Note 1. The O N/OFF regions when areas settings are used with the E3X-DA@TW-S are as follows:
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
2. Time Charts for Timer Settings (T: Set Time)
Model M ode se-
lector Timing chart Mode
selector Output circuit
E3X-DA11-S
E3X-DA6-S
E3X-DAG11-S
E3X-DAG6-S
E3X-DAB11-S
E3X-DAB6-S
LIGHT
ON
(L/ON)
Light ON
DARK ON
(D/ON) Dark ON
E3X-DA11TW-S
E3X-DA6TW-S LIGHT
ON
(L/ON)
Light ON
DARK ON
(D/ON) Dark ON
E3X-DA11RM-S
E3X-DA6RM-S LIGHT
ON
(L/ON)
Light ON
DARK ON
(D/ON) Dark ON
ON delay OFF delay One-shot
Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between brown
and black)
Display Operation indicator
(orange)
Power
tuning
indicator
(orange) Photo-
electric
Sensor
main
circuit
Brown
Black Load
Control output
Blue
12 to
24 VDC
Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between brown
and black)
Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between brown
and black)
CH1/
CH2
Display Operation indicator
(orange) ch 2
Photo-
electric
Sensor
main
circuit
Brown
Black Load
Control
output 1
Blue
12 to
24 VDC
Operation indicator
(orange)
ch 1
Load
Control
output 2
Orange
Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between brown
and black)
CH1/
CH2
Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between brown
and black)
Display
Photo-
electric
Sensor
main
circuit
Brown
Black Load
Control output
Blue
12 to
24 VDC
External
input
Orange
Operation indicator
(orange)
Power
tuning
indicator
(orange)
Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between brown
and black)
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
E3X-DA-S Digital Fiber Sensors 19
PNP Output
Note 1. The ON/O F F regions when areas settings are used with the E3X-DA @TW-S are as follows:
LIGHT ON: ON when the incident level is between t he thresholds for channels 1 and 2.
DA RK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
2. Time Charts for Timer Settings (T: Set Time)
Model Mode se-
lector Timing chart State of
output
transistor
Output circuit
E3X-DA41-S
E3X-DA8-S
E3X-DAG41-S
E3X-DAG8-S
E3X-DAB41-S
E3X-DAB8-S
LIGHT
ON
(L/ON)
Light ON
DARK ON
(D/ON) Dark ON
E3X-DA41TW-S
E3X-DA8TW-S LIGHT
ON
(L/ON)
Light ON
DARK ON
(D/ON) Dark ON
E3X-DA41RM-S
E3X-DA8RM-S LIGHT
ON
(L/ON)
Light ON
DARK ON
(D/ON) Dark ON
ON delay OFF delay One-shot
Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between blue
and black)
Display
Photo-
electric
Sensor
main
circuit
Brown
Black
Load
Control
output
Blue
12 to
24 VDC
Operation indicator
(orange)
Power
tuning
indicator
(orange)
Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between blue
and black)
CH1/
CH2 Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between blue
and black) Photo-
electric
Sensor
main
circuit
Brown
Black
Load
Control
output 1
Blue
12 to
24 VDC
Load
Control
output 2
Orange
Display Operation indicator
(orange) ch 2
Operation indicator
(orange)
ch 1
CH1/
CH2 Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between blue
and black)
Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between blue
and black)
Display
Photo-
electric
Sensor
main
circuit
Brown
Black
Load
Control output
Blue
12 to
24 VDC
External
input
Orange
Operation indicator
(orange)
Power
tuning
indicator
(orange)
Incident light
No incident light
Operation
indicator (orange) ON
OFF
Output
transistor ON
OFF
Load (relay) Operate
Release (Between blue
and black)
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
Incident light
No incident light
T
20 E3X-DA-S Digital Fiber Sen so rs
Nomenclature
Amplifier Units
Adjustment Methods
1. Setting the Operation Mode
The operation mode is set with the Mode Selector.
*E3X-DA@T W -S: The operation mode is set in SET mode. Ref er to
5. Setting Functions in SET Mode on page 22.
*E3X-DA@TW-S: Set the Channel Selector to the desired channel
before making any adjust ments or settings. This is true for all ad-
justments and settings.
2. Adjusting the Power (RUN Mode)
The current incident light level can be adjusted to near the power
tuning target value (default: 2,000).
*Confir m that the MODE key setting is PTUN (power tuning). The
default setting is PTUN. Refer to 5. Setting Functions in SET Mode
on page 22
* Setting Errors
An error has occurred if one of the following displays appears after
the progress bar is displayed.
Note:Press the DOWN key right after pressing the MODE key.
3. Setting Thresholds Manually
(RUN Mode)
A threshold can be set manually. A threshold value can also be fine-
tuned using manual setting after teaching.
*Even if the display method for display switching is changed, the
threshold will appear on the sub-display when the key is pressed.
UP
DOWN
MODE
Lock Button
Locks the fiber.
Operation Keys
Function setting operations
Operation Mode Selector
Mode Selector
Use to select SET or RUN mode.
Operation Indicator (orange)
ON when output is ON.
OFF when output is OFF.
UP
DOWN
MODE
Lock Button
Locks the fiber.
Operation indicator
for channel 1 (orange)
ON when output is ON.
OFF when output is OFF. Mode Selector
Use to select SET or RUN mode.
Channel Selector
Power Tuning
Indicator
ON: Power
tuning is set.
Sub-Display (Green)
Threshold, function
settings, etc.
Main Display (Red)
Incident level,
function, etc.
E3X-DA@-S
E3X-DA@RM-S E3X-DA@TW-S
Use to switch between Light
ON and Dark ON modes. Use to switch between
channels 1 and 2.
Operation indicator
for channel 2 (orange)
ON when output is ON.
OFF when output is OFF.
Operation Keys
Function setting operations
Sub-Display (Green)
Threshold, function
settings, etc.
Main Display (Red)
Incident level,
function, etc.
Operation mode Operation
Light ON L·ON
Dark ON D·ON
L
(Factory-set)
D
3 s
MODE
RUN
Release the key after
the progress bar
is displayed.
The Power Tuning indicator
will light when the adjustment
has been completed.
Light level Threshold (default)
PTUN Progress bar
Display changes after
specific time.
Power tuning
target value
Light level Threshold
Set the Mode Se-
lector to RUN.
(Factory-set to RUN)
Display Error Action
Over E rror
The incident light
level is too low for
the power tuning
target value.
The power will not be
tuned. The power can
be increased up to ap-
proximately 5 times
the inci dent l ight va lue .
Bottom Error
The incident light
level is too high
for the power tun-
ing target value.
The power will be
turned to the minimum
level. The power can
be dec rea sed do wn to
approxim ately 1/25th
the inci dent l ight va lue .
DOWN MODE
3 s
The Power Tuning indicator
will go out when the default
settin
g
has been restored.
"OFF" will flash twice.
To restore the default
power settings:
PTUN OFF
Light level Threshold
Press together (see note).
PTUN OVER
Flashes twice
PTUN BOTM
Flashes twice
UP DOWN
Light level
Increases threshold. Decreases threshold.
Threshold (default)
RUN
Set the Mode Se-
lector to RUN.
(Factory-set to RUN)
E3X-DA-S Digital Fiber Sensors 21
4. Teaching the Threshold Value
(SET Mode)
*There are four methods that can be used f or teaching, as described
below. Use the method most suitable for the application.
*An error has occurred if OVER, LO, or NEAR is display ed on the
sub-display. Repeat the operation from the be ginning.
4-1. Setting the Threshold at Maximum
Sensitivity
The threshold can be set at the maximum sensitivity. This method is
ideal when using a Through-beam Fiber Unit to detect workpieces
so that detection is not influenced to any great degree by dust and
other environmental factors.
4-2. Te achin g a Th rough-beam Fibe r Uni t
without a Wo rkp ie ce
A value about 6% less than the incident light level can be set as the
threshold value. This method is ideal when detecting very small dif-
ferences in light level, such as when detecting very fine workpieces
or transparent workpieces like transparent fi bers.
4-3. T eaching a Reflective Fiber Unit without
a Workpiece
A value about 6% greater than the incident light le vel can be set as
the threshold value. This method is ideal when us ing a Reflective
Fiber Unit to detect workpieces so that detection is not influenced to
any great degree by dust and other environmental factors.
4-4. Teaching With and Without a Workp ie ce
Teaching can be performed twice, once with and once without a
workpiece, and the value between the two measured value can be
set as the threshold.
UP DOWN
SET
The threshold value that
was set will flash twice.
Light level Threshold
FULL Threshold
The previous display will
return when the setting
has been com
p
leted.
Light level Threshold
Set the Mode Selector
to SET.
Either for 3 s
UP DOWN
RUN
"- - - -" will be displayed.
With no workpiece:
The previous display will
return when the setting
has been completed.
The set threshold
value will flash twice.
Threshold
TECH ----
Light level Threshold
THRU Threshold
Either for 1 s
To RUN
Light level
SET
Set the Mode Selector
to SET.
UP DOWN
UP DOWN
SET
"- - - -" will be displayed.
With no workpiece:
The previous display will
return when the setting
has been com
p
leted.
The set threshold
value will flash twice.
Light level Threshold
TECH ----
Light level Threshold
RFCH Threshold
Set the Mode Selector
to SET.
Either for 1 s
Either for 3 s
UP DOWN
UP DOWN
Workpiece
SET
"- - - -" will be displayed.
With a workpiece:
The previous display will
return when the setting
has been completed.
The set threshold
value will flash twice.
Light level Threshold
TECH ----
Light level Threshold
RFCH Threshold
Set the Mode Selector
to SET.
With no workpiece:.
Either for 1 s
Either for 1 s
22 E3X-DA-S Digital Fiber Sen so rs
5. Setting Functions in SET Mode
*The default settings are shown in the transition boxes between functions.
For the E3X-DA@-S
UP
D
O
W
N
M
O
D
E
M
O
D
E
UP
D
O
W
N
M
O
D
E
UP
D
O
W
N
M
O
D
E
UP
D
O
W
N
M
O
D
E
M
O
D
E
UP
D
O
W
N
M
O
D
E
A
E
S
et the Mode
S
elector
to
S
ET
.
D
e
tectio
n
Tim
er
Tim
e
Displa
y
switc
h
(To chan
g
e the display method
)
S
tandard mod
e
Super-hi
g
h-speed mod
e
Hi
g
h-resolution mod
e
OFF-dela
y
time
r
Tim
e
r
d
i
sab
l
ed
ON-dela
y
time
r
O
ne-shot time
r
S
witch to desire
d
f
u
n
c
ti
o
n.
Chan
g
es the settin
g.
Tim
e
r
d
i
sab
l
ed.
2
0
to 2
00
m
s
2
00
ms to 1
s
5
-ms increment
s
1 to 2
0
m
s
1-m
s
in
c
r
e
m
e
nt
s
1
00
-ms increment
s
1 to
5
s
1-
s
in
c
r
e
m
e
nt
s
Settin
g
ran
g
e: 0 to 5,000 m
s
Li
g
ht Level and Threshold Displa
y
*
1
MODE key
y
(To chan
g
e the function of the MODE key durin
g
operation
)
Power tunin
g
tar
g
et valu
e
Ex
ecu
t
es
a
z
e
r
o
r
ese
t
.
Executes power tunin
g.
Maximum power
M
S
ettin
g
ran
g
e: 100 to 3,900 (increments of 100
)
UP
D
O
W
N
UP
D
O
W
N
M
O
D
E
B
Display orientation
py
(To reverse the orientation of the displa
y
.
)
Up/down reversed displa
y
Normal displa
y
% li
g
ht leve
l
D
e
t
ec
ti
o
n
s
t
a
t
us
L-P
E
D-B
T
L
-
BT
D
-
PE
The incident li
g
ht level and the threshold value
.
The incident li
g
ht level as a percenta
g
e of th
e
thr
es
hol
d
v
a
l
ue
a
n
d
th
e
thr
es
hol
d
v
a
l
ue.
The incident li
g
ht peak level and no incident li
g
ht
bo
tt
o
m l
e
v
e
l.
(
Refreshed when out
p
ut turns ON or OFF.
)
The min. incident li
g
ht peak level and max. incident
li
g
ht bottom level, showin
g
min. width of li
g
ht level
chan
g
e. (Refreshed when output turns ON or OFF.
)
Analo
g
bar display. The current detection status i
s
displayed as an analo
g
bar. The bar will len
g
the
n
from the ri
g
ht as ON status is reached.
(
ON: Red; OFF: Green
)
The current incident li
g
ht level and the pea
k
incident li
g
ht level.
The incident li
g
ht level and the channel.
(
For the E3X-D
A
@
RM-S Onl
y)
Th
e
c
o
u
nt
e
r v
a
l
ue.
Li
g
ht leve
l
Fix
ed
int
e
rv
al
*
1
The displa
y
will be switched as shown below
.
R
e
f
e
r t
o
2. Adjusting the Power (RUN Mode)
on page 19.
)
Teac hing: Refer to 4. Teaching the Threshold Value (SET Mode) on page 21.
E3X-DA-S Digital Fiber Sensors 23
For the E3X-DA@TW-S For the E3X-DA@RM-S
UP
DO
W
N
M
O
D
E
M
O
D
E
UP
DO
W
N
M
O
D
E
UP
D
O
W
N
M
O
D
E
UP
DO
W
N
M
O
D
E
UP
D
O
W
N
M
O
D
E
A
B
E
S
et the Mode
S
elector
to
S
ET
.
Standard mod
e
Super-hi
g
h-speed mod
e
Operation mode
Ope a o ode
D
e
t
ec
ti
on
Differential ed
ge
Diff
e
r
e
nti
a
l tim
e
(To chan
g
e response speed, detection accuracy/method
)
Double ed
ge
dge
Single ed
500
µ
s
2
50
µ
µ
s
1 m
s
500
µ
µ
s
2 m
s
1 m
s
2
0
m
s
s
10 ms
2
00
m
s
100 ms
100 m
S
witch to desire
d
f
u
n
c
tion
.
Chan
g
es the settin
g.
Differential o
p
eratio
n
N
o
t
d
iff
e
r
e
nti
al
o
p
eratio
n
Dark
ON
Li
g
ht O
N
Li
g
ht Level and
Threshold Displa
y
S
ee For the E
3
X-D
A
@
-
S
on
previous pa
g
e.
Twin outputs
(To chan
g
e the output for channel 2
)
Out
p
ut for each channel
.
th
e
two thr
es
hol
ds.
Self-dia
g
nosis outpu
t
This settin
g
is disabled if differential
o
p
eration is set for the detection function.
(Alarm outputs are alwa
y
s used for
differential o
p
eration.
)
(
Refer to
1
. Settin
g
the Operation Mod
e
, pa
g
e 20.
)
Teaching: Refer to 4. Teaching the
Threshold Value (SET Mode) on page 21.
UP DOWN
MODE
MODE
UP DOWN
MODE
UP DOWN
MODE
UP DOWN
MODE
UP DOWN
MODE
UP DOWN
MODE
UP DOWN
MODE
A
B
Setting range: 1 to 9,999,999
SET
Set the Mode Selector
to SET.
Switch to desired
function.
Light Level and
Threshold Display
Counter
Count
(To set the counter function.)
External
input memory (Refer to instructions provided with the product.)
External
input
(To change function controlled
by external input.)
Counter enabled
Counter
disabled
500 µs250 µs1 ms500 µs2 ms1 ms 20 ms10 ms 200 ms100 ms
Thru-beam, no-workpiece
teaching
Reflective, no-workpiece
teaching
With/Without-workpiece
teaching
Automatic teaching
Power tuning
Light OFF
Counter reset
THRU
RFCT
2PNT
AUTO
PTUN
LOFF
CRST
Counter disabled.
Count incremented when
output turns ON.
Count decremented when
output turns ON.
OFF
CUP
CDO
Write results to EEPROM.
Don't write results.
ON
OFF
Standard mode
Super-high-speed mode
High-resolution mode
Differential operation
Detection
Differential edge
(To change response speed, detection accuracy/method)
Double edge
Single edge
Changes the setting.
Differential operation
Not
differential
operation
Differential time
Double
edge
Single
edge
See
For the E3X-DA
@
-S
on
previous page.
Zero reset
0RST
Teaching: Refer to 4. Teaching the Thresh-
old Value (SET Mode) on page 21.
24 E3X-DA-S Digital Fiber Sen so rs
6. Convenient Functions
6-1. Zeroing the Digital Disp lay
The incident light lev el on the digital displa y can be set to 0.
*Change the function to 0RST (zero reset) with the MODE k e y. The
default setting is PTUN. Refer to 5. Setting Functions in SET Mode
on page 22.
6-2. Locking the Keys
All key operations can be disabled.
Note:Press the DOWN key right after pressing the MODE key.
6-3. Initializing Settings
All settings can be returned to their original default settings.
3 s
MODE
3 s
MODE
DOWN MODE
RUN
To reset to 0 again:
To return to original value
for incident light level:
Set the Mode Selector
to RUN
Fastory setting
3 s
Press to
g
ether (see note).
MODE
MODE
UP
UP
RUN
"OFF" will flash twice and
key operations will be
enabled.
To release the lock:
"ON" will flash twice and
key operations will be
disabled.
LOC ON
LOC OFF
Set the Mode Selector
to RUN.
Factory setting
* If a key is pressed while key operations are locked, "LOC" will flash
twice on the display to indicate that
key operations have been disabled.
3 s
Press together (see note).
3 s
Press together (see note).
MODEMODE
UP DOWN
SET
Settin
g
s initialized. O
p
eration canceled.
INIT NO?
Set the Mode Selector
to SET.
INIT YES?
UP DOWN
3 s
Press together (see note).
E3X-DA-S Digital Fiber Sensors 25
Safety Precautions
Note:In addition to the following precautions, please read and ob-
serve the common precautions for the instructions included
with the product.
Precautions for Correct Use
Amplifier Unit
Installation
Operation after Turning Power ON
The Amplifier Unit is ready to operate within 200 ms after the power
supply is turned ON. If the Sensor and load are connected to power
supplies separately, be sure to turn ON the power supply to the Sen-
sor f irst.
Mounting
Connecting and Disconnecting Connect ors
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit until it
cli cks int o place.
2. Attach the protector seals (provided as accessories) to the sides
of master and slave connect ors that are not connected.
Note:Attach the seals to the sides with grooves
Removing Connectors
1. Slide the slave Amplifier Unit(s) for which the Connector is to be
removed away from the rest of the gr oup.
2. After the Amplifier Unit(s) has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remov e
Connectors without separating them from other Amplifier Units
first.)
Joining and Removing Amplifier Units
Joining Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN trac k.
2. Slide the Amplifier Units together, line up the clips , and press the
Amplifier Units together until they click into place.
Separating Amplifier Units
Slide Amplifier Units away from each other, and remove from the
DIN track one at a time. (Do not attempt to remove Amplifier Units
from the DIN track without separating them first.)
Note 1. The specifications for ambient temperature will vary accord-
ing to the number of Amplifier Units used together. For de-
tails, refer to Ratings/Characteristics.
2. Always turn OFF the power supply before joining or separat-
ing Amplifier Units.
Mounting the End Plate (PFP-M)
An End Plate should be used if there is a possibility of the Amplifier
Unit moving, e.g., due to vibr ation. If a Mobil e Console is going to be
mounted, connect the End Plate in the direction shown in the follow-
ing diagram.
Mounting the Mobile Console Head
Leave a gap of at least 20 mm between the neares t Amplifier Unit
and the Mobile Console head.
Insert
Seal Seal
Press down
Remove
Lever
Click into place
End Plate
20 mm
26 E3X-DA-S Digital Fiber Sen so rs
Fiber Connection
The E3X Amplifier Unit has a lock button for easy connection of the
Fiber Unit. Connect or disconnect the fibers using the following pro-
cedures:
1. Connection
Open the protective cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock
button.
Fibers with E39-F9 Attachme nt
Fibers That Cannot Be Free-Cut (with Sleeves)
2. Disconnecting Fibers
Remove the protective cover and raise the lock button to pull out the
fibers.
Note 1. To maintain the fiber properties, confirm that the lock is re-
leased before removing the fibers.
2. Be sure to lock or unlock the lock button wit hin an ambient
temperature range between -10°C and 40°C.
Adjustments
Mutual Inte rfer en ce Prot ec ti on Func tion
There may be some instability in the digital display values due to
light from other sensors. If this occurs, decrease the sensitivity (i.e. ,
decrease the power or increase the threshold) to perform stable
detection.
EEPROM Writing Error
If the data is not written to the EEPROM correctly due to a power fail-
ure or static-electric noise, initialize the settings with the keys on the
Amplifier Unit. ERR/EEP will flash on the display when a writing error
has occurred.
Optical Communicat ion s
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of
the Amplifier Units during operation.
Other Precautions
Protective Cover
Always keep the protective cover in place when using the Amplifier
Unit.
Mobile Console
Use the E3X-MC11-S Mobile Con sole for the E3X-DA-S-series
Amplifier Units. Other Mobile Consoles, such as the E3X-MC11,
cannot be used.
Lock button
Fiber
Fiber insertion
mark
Locked Unlocked
Insertion position
Protective cover
9 mm
Fiber Unit 9 mm
13 mm
9 mm
13 mm
Locked Unlocked
Protective cover
E3X-DA-S Digital Fiber Sensors 27
Dimensions
Amplifier Units
Amplifier Units with Cables
Main display Sub-display Vinyl-insulated round cable
Standard length: 2 m*
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
3.4
10
Two, 2.4 dia.
4.5
5.65
3.9×3
=11.7
12.15
15.1
32.8
3.25
29.8
3.9×3=11.7
4.3 70
32
12.5
9.9
16
3.4 4.4
34.8
28.1
1628.1
16
18.7 44.3
Two, M3
E3X-DA11-S
E3X-DA41-S
E3X-DAG11-S
E3X-DAG41-S
E3X-DAB11-S
E3X-DAB41-S
E3X-DA11RM-S
E3X-DA41RM-S
E3X-DA11TW-S
E3X-DA41TW-S
Operation indicator
With Mounting Bracket Attached
The Mounting Bracket can also be used on
this side.
Hole for optical communications
Mounting Bracket (E39-L143)
SUS304 stainless steel
Two, 3.2 dia. holes
Mounting Holes
*Cable Specifications
A 4-dia., 4-conductor (conductor cross-sectional
area: 0.2 mm2; insulation diameter: 1.1 mm)
E3X-DA11-S/DA41-S/DAG11-S/
DAG41-S/DAB11-S/DAB41-S
E3X-DA11TW-S/DA41TW-S/
DA11RM-S/DA41RM-S
A 4-dia., 3-conductor (conductor cross-sectional
area: 0.2 mm2; insulation diameter: 1.1 mm)
28 E3X-DA-S Digital Fiber Sensors
Amplifier Units with Connectors
Amplifier Unit Connectors
Master Connectors
3.4
3.9×3
=11.75
12.15
15.1
32.8
3.25
29.8
3.9×3=11.7
4.3 70 8.1
32
12.95
9.9
16
34.8
28.1
18.7 44.3
3.4 4.4
16
Two, M3
10
Two, 2.4 dia.
4.5
5.65
Connector
Dia. A*2
1628.1
E3X-DA6-S
E3X-DA8-S
E3X-DAG6-S
E3X-DAG8-S
E3X-DAB6-S
E3X-DAB8-S
E3X-DA6RM-S
E3X-DA8RM-S
E3X-DA6TW-S
E3X-DA8TW-S
With Mounting Bracket Attached
Hole for optical communications
Mounting Bracket (E39-L143)
SUS304 stainless steel
Two, 3.2 dia. holes
Mounting Holes
*1 The Mounting Bracket can also
be used on this side.
*2 Cable Diameters
Main display Sub-display
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
Operation indicator
A*1 E3X-CN11 (3 conductors)
E3X-CN21 (4 conductors)
E3X-CN22 (2 conductors)
4.0-mm dia.
E3X-CN12 (1 conductor)2.6-mm dia.
14.4
2.6
6
2.9
10
0.8 8.4
6.8
10.7
30±2
4 dia.
10±2
4
15.1
6
*
*E3X-CN11: A 4-dia., 3-conductor, vinyl-insulated round cable (conductor cross-
sectional area: 0.2 mm
2
; insulation diameter: 1.1 mm) is used.
E3X-CN21: A 4-dia., 4-conductor, vinyl-insulated round cable (conductor cross-
sectional area: 0.2 mm
2
; insulation diameter: 1.1 mm) is used.
2000
E3X-CN11
E3X-CN21
+50
0
50+5
0
E3X-DA-S Digital Fiber Sensors 29
Slave Connectors s
Mobile Console
14.4
2.6
3
6
2.9
10
0.8 8.4
6.8
10.7 2,000
50
30±
2
E3X-CN12: 2.6 dia.
E3X-CN22: 4 dia.
10±
2
4
15.1
6
*
+5
0
+50
0
E3X-CN12
E3X-CN22
*E3X-CN12: A 2.6-dia., single-conductor, vinyl-insulated round cable (conductor cross-
sectional area: 0.2 mm2; insulation diameter: 1.1 mm) is used.
E3X-CN22: A 4-dia., 2-conductor, vinyl-insulated round cable (conductor cross-
sectional area: 0.2 mm2; insulation diameter: 1.1 mm) is used.
136
50
52.8
22 Optical communications connection indicator
Sensor
operation
indicator Main display
Sub-display
RIGHT key
ESC/PWR
key
Operation keys
ENT
key
LEFT
key
UP key
DOWN
key
20
28.8
13.2
31.2
9.9
27.7 17.3
1.2 5.1 12.3
36.7
51.3 5.6
24.3
30.3
31.8 16.3
13.1
(38.2)
10
AC adapter jack
Communications jack
Menu indicators
Channel indicator
M5 ball plunger
Battery
indicators
Channel
buttons
Optical communi-
cations position
Communications jack
E3X-MC11-S Mobile Console Mobile Console Head
30 E3X-DA-S Digital Fiber Sen so rs
E3X-DA-S Digital Fiber Sensors 31
32
In the interest of product impr o v eme nt, specifications are sub jec t to c hange witho ut notic e.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. E336-E1-01
OMRON Corporation
Industrial Automation Company
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107 Printed in Japan
0103-2M (0103) (O)