23/06/2014 www.crouzet.com ETM / ETM2 / ETM22 motor thermal protection ETM22 Part number 84874035 *Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection *Version ETM2 / ETM22 : Fault latching function Pushbutton for local reset Remote reset via external contact Pushbutton test facility 2 LEDs to indicate relay and power supply status Part numbers 84 874 035 Type Output Supply voltage ETM22 2 changeovers 24 V AC/DC Specifications Supply voltage Un Operating range Nominal power Maximal power Immunity from micro power cuts Delay on pick-up Insulation coordination Max. resistance of cold probes Trip threshold Reset threshold Short-circuit detection Measurement voltage as per IEC/EN 60034-11 Repetition accuracy with constant parameters Temperature drift Voltage-dependent drift 230, 120 and 24 VAC 50 / 60 Hz Galvanic isolation by transformer 24 VDC no galvanic isolation 0.85 to 1.10 Un 3 VA 5 VA 10 ms 500 ms Category III, degree of pollution 2 conforming to IEC/EN 60664-1 / VDE 0110 : 4 KV/2 1500 3100 10 % 1650 10 % 0 - 10 2,5 V 0.5 % 0.05 % / oC -2 % Output Breaking capacity Max. breaking current Max. breaking voltage Min. breaking current Maximum rate Mechanical life (operations) AgNi 90/10 2000 VA / 80 W 8 A AC 440 V AC 100 mA 360 operations / hour at full load Electrical life AC12 : 2000 VA - 105 operations AC15 : Cos = 0,3 - 6000 operations DC13 : L/R = 300 ms - 6000 operations Reset time Response time Display on ETM2/ETM22 - power supply Display on ETM2/ETM22 - Relay Class of protection (IEC EN/60529) - Term. block Protection class (IEC EN/60529) - Casing Housing material Weight (g) Terminal capacity 500 ms 500 ms green LED yellow LED IP 20 IP 50 Self-extinguishing 145 Temperature limit operation (IEC 68.1.14) (C) Temperature limits stored (IEC 68.1.1/2) (C) Relative humidity (no condensation) 5 x 106 2 x 1.5 mm2 with ferrule 2 x 2.5 mm2 without ferrule -20 +60 C -30 +70 C 95 % (+2 % ; -3 %) Principles Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 www.crouzet.com Operating principle Control relay is used in combination with PTC thermistor probes (not supplied) for thermal protection of machines (motors, alternators, transformers, etc). The probes are placed at critical points on the equipment to be protected (normally inserted into the stator windings of motors). The resistance of the PTC probe has a positive temperature coefficient. As soon as the nominal trip temperature of the probe is exceeded, the resistance of the probe increases rapidly. Protection relay detects this and opens the power supply circuit of the protected equipment (eg motor) and the yellow fault indicator LED lights up (version ETM2/ETM22). Test button The ETM2/ETM22 has a TEST button which can be used to simulate a thermal overload in order to test the service condition of the relay. Tripping The relay drops out as soon as the protected equipment is subjected to a thermal overload, short-circuit or break in the probe measuring circuit. Early warning of tripping If the equipment being protected has another PTC proble with a lower nominal trip temperature, a second ETM/ETM2/ETM22 relay can be used to give early warning of tripping and thus prevent breaks in operation. Control relay ETM/ETM2/ETM22 is automatically reset as soon as the temperature drops below the trip threshod (the yellow fault indicator LED goes out). No Legend Unit power-up Resistance between terminals T1 and T2 Output relay Principles The relay is reset either using the RESET pushbutton on the front face or by opening the external contact S2 (remote reset), or by cutting the auxiliary power supply (terminals A1 - A2). If the auxiliary power is cut for a period of time greater than the reset time (500 ms), the relay is reactivated if the proble detects a normal temperature when the power supply voltage is restored. No Legend Unit power-up Latching contact Resistance between terminals T1 and T2 Output relay Principles Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 www.crouzet.com The relay is reset either using the RESET pushbutton on the front face or by opening the external contact S2 (remote reset), or by cutting the auxiliary power supply (terminals A1 - A2). If the auxiliary power is cut for a period of time greater than the reset time (500 ms), the relay is reactivated if the proble detects a normal temperature when the power supply voltage is restored. No Legend Resistance R () Nominal temprerature Tripping (C) Dimensions (mm) ETM / ETM2 / ETM22 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 Connections ETM22 Legend A1 - A2 : supply voltage 11 - 12 -14 : low treshold output relay (R1) 21 - 22 -24 : high treshold output relay (R2) T1 -T2 : external PTC probe Y1 - Y2 : remote reset contact Connections ETM Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 23/06/2014 Legend *** TRADUCTION MANQUANTE *** *** TRADUCTION MANQUANTE *** *** TRADUCTION MANQUANTE *** *** TRADUCTION MANQUANTE *** *** TRADUCTION MANQUANTE *** Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 84874035