Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
LE (ALE)
ASCTB194E 201202-T
2. Specifications
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Characteristics Item Specifications
Contact Contact material AgSnO2 type
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Rating
Nominal switching capacity (resistive load) 16A 277V AC
Max. switching power (resistive load) 4,432VA
Max. switching voltage 277V AC
Max. switching current 16A
Nominal operating power 400mW (Standard type), 200mW (High sensitive type)
Min. switching capacity (reference value)*1100mA, 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial) Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Temperature rise (coil) Max. 55°C 131°F, Max. 45°C 113°F (200mW type) (By resistive method, nominal coil voltage
applied to the coil; contact carrying current: 16A, at 20°C 68°F)
Surge breakdown voltage*2
(Between contact and coil) (Initial) 10,000 V
Operate time (at nominal voltage) (at 20°C 68°F) Max. 20 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F) Max. 20 ms, Max. 25 ms (200mW type) (excluding contact bounce time) (With diode)
Mechanical
characteristics
Shock resistance Functional 200 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life Mechanical (at 180 times/min.) Min. 2×106
Electrical (at 20 times/min.) Min. 105 (at resistive load)
Conditions Conditions for operation, transport and storage*3Ambient temperature: –40°C to +85°C –40°F to +185°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 17 g .60 oz, Approx. 15 g .53 oz (PCB type)
1-1. Coil temperature rise (400mW type)
Sample: ALE14B12, 6 pcs.
Point measured: coil inside
Ambient temperature: 25°C 77°F, 85°C 185°F
1-2. Coil temperature rise (200mW type)
Sample: ALE74B12, 6 pcs.
Point measured: coil inside
Ambient temperature: 23.7°C 74.66°F, 85°C 185°F
2. Life curve
800
0
10
20
30
40
Temperature rise, °C
Coil applied voltage, %V
50
60
100 145
12A
12A
16A
0A
16A
0A
85°C
25°C
800
0
5
10
15
20
Temperature rise, °C
Coil applied voltage, %V
25
30
100 145
16A
0A
16A
0A
85°C
23.7°C
100
10
120 468101214 16
250V AC resistive load
Contact current, A
Life, ×104