OOAA112255 SSeerriieess
Frame Diecast Aluminum Operating Temperature
Ball Bearing
-20C ~ +80C
Sleeve Bearing
-10C ~ +50C
Life Expectancy
Ball Bearing
60,000 hours (L10 at 40C)
Sleeve Bearing
30,000 hours (L10 at 40C)
Dual Voltage
Connection via 4x leads.
Fans can be configured for
115V or 230V operation.
Weight
37 grams
Impeller PBT, UL94V-O plastic
Connection 2x Lead Wires 22 AWG or
terminals
Motor
Shaded pole, impedance
and thermally protected
Tachometer available
(5VTTL), input 5 ~24V
Bearing System Dual ball or Sleeve
Insulation Resistance >100M ohm between lead-
wire and frame (500VDC)
Dielectric Strength 1 min at 1500 VAC, 50/60Hz
RoHS Compliant
10557 Metric Drive
Dallas, Texas 75243
214-340-0265
OrionFans.com
Information and data is subject to
change without prior notification.
* Indicate “TB” (Terminal Ball Bearing), “WB” (12” Wire Leads, Ball Bearing), “TS” (Terminal, Sleeve Bearing), “WS” (12” Wire Leads, Sleeve Bearing)
** Indicate “B” (Ball Bearing) or “S” (Sleeve Bearing)
Frame Style - m0
AC Fan - 115V, 230V, Dual Voltage
120 x 25mm (4.7” x 1.0”)
Model Number Speed (RPM) Airflow (CFM) Noise (dB) Volts AC Voltage
Range Watts Max. Static
Pressure (“H2O)
OA125AP-11-1* (m0) 2900 81 33 115 80~130 13 .23
OA125AP-11-2* (m0) 2300 60 27 115 80~130 10 .18
OA125AP-11-3* (m0) 1600 42 22 115 80~130 6 .12
OA125AP-22-1* (m0) 2900 81 32 230 160~260 13 .23
OA125AP-22-2* (m0) 2300 60 27 230 160~260 10 .18
OA125AP-22-3* (m0) 1600 42 22 230 160~260 6 .12
OA125AP-11/22-1W** (m0) 2900 81 32 115/230 80~260 13 .23
OA125AP-11/22-2W** (m0) 2300 60 27 115/230 80~260 10 .18
OA125AP-11/22-3W** (m0) 1600 42 22 115/230 80~260 6 .12