CXA20 Series Single and dual output DC-DC CONVERTERS * * * * * * * * 20 W DC-DC Converters 1 4:1 input voltage range No minimum load on singles 6 A on 3.3 V output (@ 48 Vin) at 50 C in still air Wide operating temperature with overtemperature protection 10% output voltage trim Remote On/Off control Overvoltage protection Available RoHS complaint The CXA20 is a new 20 W addition to the CXA family of open-frame, isolated, dc-dc converters. The five model series features a 4:1 input voltage range of 18 Vdc to 75 Vdc, making it suitable for a wide variety of communications and distributed power applications. With its 2.0 x 1.6 inch industry standard footprint, the CXA20 provides an easy upgrade option for new and existing Artesyn customers seeking a high-performance, cost-effective power supply. The CXA20 is available in output voltages of 3.3 V, 5 V, 12 V, 5 V and 12 V. The 3.3 V version delivering up to 6 A is fully rated to 20 W. Typical efficiency for the CXA20 is 83%. The CXA20 offers remote ON/OFF as well as overvoltage, overtemperature and short circuit protection features. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25 C unless otherwise stated OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Voltage accuracy 1.0% Line regulation (LL to HL) Singles/dual positives Dual negatives 0.1% 0.1% Load regulation (not incl. cross reg.) Full load to minimum load S3V3 Singles/dual positives Dual negatives 0.2% 0.1% 0.1% Minimum load Singles Duals (for imbalanced loads) Ripple and noise 20 MHz bandwidth S3V3, S05, D05 S12, D12 All models None 10% 75 mV pk-pk max. 100 mV pk-pk max. 20 mV rms max. Temperature coefficient 0.02%/C Overvoltage protection See Application Note 107 Short circuit protection Short <20 m Hiccup Continuous automatic recovery Transient response 25% load step Load cross regulation (See Note 1) 10% load to full load, either output 2.0% max. dev., 300 s recovery to within total error band 7.0% INPUT SPECIFICATIONS Input voltage range 48 Vin nominal Input fuse HRC recommended Max. input rise and fall time 48 V ETS300-132 UVLO turn ON voltage UVLO turn OFF voltage (See Note 4) (See Note 4) Remote ON/OFF Logic compatibility ON OFF 18-75 Vdc 2.0 A ETS 300 386-1 table 5 Conducted emissions Radiated emissions Immunity: ESD air ESD contact EFT DC power EFT signal Radiated field enclosure Surges indoor signal Conducted (dc power) Conducted (signal) Input transients CMOS/TTL/Open Collector Open circuit or >2 Vdc <1.2 Vdc EN61000-4-2 8 kV (NP), 15 kV (RP) EN61000-4-2 6 kV (NP), 8 kV (RP) EN61000-4-4 2 kV (NP), 4 kV (LFS) EN61000-4-4 1 kV (NP), 2 kV (LFS) EN61000-4-3 10 V/m (NP) EN61000-4-5 500 V (RP) EN61000-4-6 10 V (NP) EN61000-4-6 10 V (NP) ETS 300 132-2, ETR 283 GENERAL SPECIFICATIONS Efficiency Overtemp. shutdown Isolation voltage Switching frequency Approvals and standards (See Notes 6,7,8) Material flammability Weight MTBF (Representative model 48S05J @ 48 Vin) See table 120 C Input/output test voltage 1500 Vdc Fixed 400 kHz EN60950 UL1950 File No. E136005 UL94V-0 26 g (0.92 oz) MIL-HDBK-217F 3,485,000 hours Parts stress method Ground Benign @ 25 C ENVIRONMENTAL SPECIFICATIONS Thermal performance 5 V/ms 92% 86% EN55022, ext. cap. (Note 5) Level A EN55022, external filter, Level B VDE0878, 48V models EN55022-B See App. Note 107 ETS 300 019-2-3 Air temperature Relative humidity Operating ambient -40 C to +60 C, temperature (See Note 9) Non-operating -55 C to +125 C Classes T3.1, 3.2, 3.3, 3.5 Low: IEC 68-2-1 -40 C High: IEC 68-2-2 +60 C Change: IEC 68-2-14 -40 C to +60 C IEC 68-2-56 10% to 100% RH IEC 68-2-30 Condensation File Name: cxa20.pdf Rev (02): 09 Dec 2005 CXA20 Series Single and dual output DC-DC CONVERTERS 20 W DC-DC Converters 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm INPUT VOLTAGE OUTPUT VOLTAGE OVERVOLTAGE PROTECTION (2,3) OUTPUT CURRENT (MAX.) TYPICAL EFFICIENCY MODEL NUMBER (10,11) 18-75 Vdc 3.3 V 3.7 V 6A 80% CXA20-48S3V3J 18-75 Vdc 5V 6.67 V 4A 83% CXA20-48S05J 18-75 Vdc 12 V 14.25 V 1.66 A 83% CXA20-48S12J 18-75 Vdc 5 V 6.67 V 2 A ea. 84% CXA20-48D05J 18-75 Vdc 12 V 14.25 V 0.83 A ea. 84% CXA20-48D12J Notes PIN CONNECTIONS 1 2 3 4 5 6 7 8 Negative output voltage deviation when either load is changed. For TVS/Zener specifications please see Application Note 107. On dual output models, OVP protection is on positive outputs only. With respect to minimum input voltage. With one external 4 F capacitor across the input. Unit provides basic insulation up to the 75 Vdc maximum input voltage. Maximum continuous output power not to exceed 20 Watts. User must provide 2 A HRC (recommended) in line fuse in order to comply with safety approvals. 9 Download Application Note 107 and the full data sheet from our website. 10 The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 11 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. MAX. TEMPERATURES FOR FULL RATED OUTPUT CURRENT MODEL FULL Vin RANGE Vin <60 Vdc 48S3V3J 50 C 50 C 48S05J 55 C 60 C 48S12J 50 C 55 C 48D05J 55 C 60 C 48D12J 50 C 60 C PIN NUMBER SINGLE OUTPUT DUAL OUTPUT 1 + Input + Input 2 - Input - Input 3 No Pin No Pin 4 Remote On/Off Remote On/Off 5 No Pin + Output 6 + Output Common 7 - Output - Output 8 Trim Trim EXTERNAL OUTPUT TRIMMING All models can be externally trimmed by 10% using either method shown below. See Application Note 107 for details. + Output TRIM DOWN - Output TRIM UP Trim Rated Output Current 100 CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible. 80 75% 60 40 20 0 -40C -20C 0 20 40 60 80 100 Ambient Temperature International Safety Standard Approvals Derating Curve Output Current vs Temperature S3V3J Natural Convection (<0.1 m/s airflow) UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950 File No. E174104 VDE Certificate No.112836. File No. 10401-3336-0154 CB Report and Certificate to IEC60950, Licence No. 121914 File Name: cxa20.pdf Rev (02): 09 Dec 2005 CXA20 Series Single and dual output DC-DC CONVERTERS 20 W DC-DC Converters 3 For the most current data and application support visit www.artesyn.com/powergroup/products.htm 0.02 0.004 (0.50 0.1) 0.413 (10.50) MAX. OPEN FRAME HEIGHT STAND-OFFS 4 PLACES O0.040 0.002 (O1.02 0.05) 0.14 0.02 (3.60 0.5) 2.00 0.02 (50.80 0.5) 1.80 (45.72) 5 0.70 (17.78) 1.60 0.02 (40.64 0.5) 0.10 (2.54) 0.20 (5.08) 1 0.60 (15.24) 0.50 (12.70) 6 2 BOTTOM VIEW 7 0.30 (7.62) 0.70 (17.78) 8 4 ALL DIMENSIONS IN INCHES (mm) General tolerance 0.010 (0.25) unless otherwise specified Datasheet (c) Artesyn Technologies(R) 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. Please consult our website for the following items: Application Note Longform Data Sheet www.artesyn.com File Name: cxa20.pdf Rev (02): 09 Dec 2005