Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 13
Technical Reference Note
Environmental Specifications
EMC Requirements
DA10 series power supply is designed to meet the following EMC immunity specifications:
Table 4. EMC Immunity Specifications:
Document Description
FCC Part 15 Subpart B/ EN55022, Class B Conducted and Radiated EMI Limits
EN61000-3-3 Voltage Fluctuations, δmax ≤ 4%
EN61000-4-2
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques – Electrostatic discharge immunity test. +/-8KV contact
discharge, performance Criteria B
EN61000-4-3
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques, Radiated, radio-frequency, electromagnetic field immunity test,
Criteria A
EN61000-4-4
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques, Electrical Fast Transient/Burst Immunity Test. +/-1KV , I/O and
Artesyn Embedded Technologies
signal ports performance Criteria A.
EN61000-4-5 Electromagnetic Compatibility (EMC) - Testing and measurement
techniques. +/-1KV for DC ports performance criteria A.
EN61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields –
performance criteria A
EN61000-4-11
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques : Voltage Dips and Interruptions: performance Criteria B(For
100% reduction, Criteria C).
High Frequency Pulses / Rings longer than
250ns Common Mode Noise: Less than or equal to 2.0 Vpp.