EVERLIGHT ELECTRONICS CO.,LTD. Technical Data Sheet Infrared Remote-control Receiver Module IRM-H1xx/TR2 SERIES Features High shielding against electric field disturbance. Low voltage and low power consumption. Very small sizes. External dimensions 7.40(L)*5.50(W)*2.55(H) mm. High immunity against ambient light. Photodiode with integrated circuit. TTL and CMOS compatibility. High sensitivity. Top-received SMD. Suitable burst length 10 pulses/burst. RoHS refer to IRM-Vxxx,Hxxx series SGS report Pb free. Descriptions The device is a miniature SMD type infrared remote control system receiver that has been developed and designed by utilizing the most updated IC technology. The PIN diode and preamplifier are assembled on PCB, the epoxy package is designed as an IR filter. The demodulated output signal can directly be decoded by a microprocessor. Applications 1. Optical switch 2. Light detecting portion of remote control AV instruments such as Audio, TV, VCR, CD, MD, etc. Home appliances such as Air-conditioner, Fan , etc. The other equipments with wireless remote control. CATV set top boxes Multi-media Equipment Device Selection Guide PART MATERIAL COLOR Chip Silicon --- Package Epoxy Black Metal case SPCC Silver white Everlight Electronics Co., Ltd. Device No DMO-138-376 http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 1 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES Package Dimensions Notes 1.All dimensions are in millimeters. 2.Tolerances unless dimensions 0.2mm. Soldering patterns View Back The following soldering patterns are recommended for reflow-soldering : Everlight Electronics Co., Ltd. Device No DMO-138-376 http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 2 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES Available Types For Different Carrier Frequencies Type Carrier Frequencies (Typ) IRM-H136/TR2 36 kHz IRM-H138/TR2 38 kHz IRM-H140/TR2 40 kHz Absolute Maximum Ratings (Ta=25 ) Parameter Symbol Rating Unit Supply Voltage Vcc 6 V Operating Temperature Topr -25 ~ +85 Storage Temperature Tstg -25 ~ +85 Notice Recommended Operating Condition Supply Voltage Rating: Vcc 2.7V to 5.5V Electro-Optical Characteristics (Ta=25 , Vcc = 3V) Parameter Symbol MIN. TYP. MAX. Unit Condition Supply Current Icc --- --- 3 mA No signal input Peak Wavelength p --- 940 --- nm --- L0 8 --- --- m --- L45 5 --- --- Half Angle(Horizontal) h --- 45 --- deg At the ray axis *1 Half Angle(Vertical) v --- 45 --- deg High Level Pulse Width TH 400 --- 800 s Low Level Pulse Width TL 400 --- 800 s High Level Output Voltage VH 2.7 --- --- V Low Level Output Voltage VL --- 0.2 0.5 V Reception Distance At the ray axis *2 Notes: *1The ray receiving surface at a vertex and relation to the ray axis in the range of = 0 and =45. *2A range from 30cm to the arrival distance. Average value of 50 pulses. Everlight Electronics Co., Ltd. Device No DMO-138-376 http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 3 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES The Notice of Application: Transmission remote control signal consist of four parts: Encode Part, IR Transmitter Source, IRM device, Decode Part 1. When IRM-H1xx code select frequency, it need to well understand the center system of encode part. 2. Strong or weak light of IR Transmitter can affect distance of transmission. 3. Minimum Burst Length Tburst (number of pulses per burst) : 10 cycles 4. It needs to ensure the translation range of decode part if it is applied to the pulse-width range. If the above items hardly assure of its application, it'll cause NG(no good) message from the edge of signal. Test Method The specified electro-optical characteristics is satisfied under the following Conditions at the controllable distance. Measurement place A place that is nothing of extreme light reflected in the room. External light Project the light of ordinary white fluorescent lamps which are not high Frequency lamps and must be less then 10 Lux at the module surface. (Ee10Lux) Standard transmitter A transmitter whose output is so adjusted as to Vo=400mVp-p and the output Wave form shown in Fig.-1.According to the measurement method shown in Fig.-2 the standard transmitter is specified. However , the infrared photodiode to be used for the transmitter should be p=940nm,=50nm. Also, photodiode is used of PD438B(Vr=5V). (Standard light / Light source temperature 2856K). Measuring system According to the measuring system shown in Fig.-3 Fig.-1 Transmitter Wave Form D.U.T output Pulse Carrier frequency is adjusted to center frequency of each product. OUTPUT PULSE OF DEVICE IR TANSMITTER OUTPUT WAVE FORM Duty=0.5 Everlight Electronics Co., Ltd. Device No DMO-138-376 http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 4 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES Fig.-2 Measuring Method Fig.-3 Measuring System 20cm 10k +5.0 0.1V L: Transmission Distance 10uF Standard Transmitter Standard Transmitter Vout k 0 10 Vcc OUT D.U.T Vout GND : Angle Of Horizontal & Vertical Direction Oscilloscope Block Diagram Vs IN OUT Input Oscillator CGA & filter C Demodulator AGC/ATC & digital control Carrier frequency f0 Modulated IR signal min 10 pulses GND Application Circuit RC Filter should be connected closely between Vcc pin and GND pin. Everlight Electronics Co., Ltd. Device No DMO-138-376 http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 5 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES Typical Electro-Optical Characteristics Curves Fig.-4 Relative Spectral Sensitivity vs. Wavelength Fig.-5 Relative Transmission Distance vs. Direction Fig.-6 Output Pulse Length vs. Arrival Distance Fig.-7 Arrival Distance vs. Supply Voltage 10 8 6 4 2 Everlight Electronics Co., Ltd. Device No DMO-138-376 http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 6 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES Typical Electro-Optical Characteristics Curves Fig.-8 Arrival Distance vs. Ambient Temperature Fig.-9 Relative Transmission Distance vs. Center Carrier Frequency Relative Transmission Distance (%) IRM-H136/TR2 8 6 4 Center Carrier Frequency (kHz) Fig.-9 Relative Transmission Distance vs. Center Carrier Frequency IRM-H140/TR2 Relative Transmission Distance (%) Relative Transmission Distance (%) IRM-H138/TR2 Center Carrier Frequency (kHz) Everlight Electronics Co., Ltd. Device No DMO-138-376 Center Carrier Frequency (kHz) http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 7 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES Reliability Test Item And Condition The reliability of products shall be satisfied with items listed below. Confidence level90% LTPD10% Reflow Terms: JEDEC Level 4 Specification Drying; Temp.:125 24hrs Moisture 30 / 60% RH 96hrs Reflow Temp.: 2605 10sec, 3 times Note: 1. Not sooner than 15 minutes and not longer than 4 hours after removal from the temperature/humidity chamber. 2. The time between reflow shall be 5 minutes minimum and 60 minutes maximum. Test Items Failure Judgement Criteria Test Conditions 1 cycle-25 Temperature cycle +85 (30min)(5min)(30min) 300 cycle test Temp+85 High temperature test Vcc5V 1000hrs Low temperature Temp-40 storage 1000hrs High temperature High humidity Ta85RH85% L0 Lx0.8 L45 Lx0.8 n=76,c=0 L: Lower specification limit n=76,c=0 *Icc : Operate Current (mA) Variation20%: n=76,c=0 n=76,c=0 1000hrs Everlight Electronics Co., Ltd. Device No Samples(n) Defective(c) DMO-138-376 http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 8 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES Recommended method of storage Due to the SMD IRM is moisture sensitive device, it must pay attention to moisture protection during storage and operation procedure. Dry box storage is recommended as soon as the aluminum bag has been opened prevent moisture absorption. The following conditions should be observed, if dry boxes are not available: 1. Shelf life in sealed bag: 24 months at 10 to 30 and 60% relative humidity (RH). 2. After this bag is opened, devices that will be subjected to infrared reflow, vapor-phase reflow, or equivalent processing(peak package body temp.260), must be: (a) mounted within 48 hours at factory conditions of < 30/60% RH. (b) stored per J-STD-033. 3. Devices require baking, before mounting, if humidity Indicator Card reads > 30% when read at 235. 4. If baking is required, refer to IPC/JEDEC J-STD-033 for bake procedure. 192 hours at 40+5/-0 and 5%RH (dry air / nitrogen) or 96 hours at 60+5 and < 5%RH for all device containers or 24 hours at 125+5 not suitable for reel or tubes. Recommended Solder Profile Notice: (1) Reflow soldering should not be done more than two times. (2) When soldering, do not put stress on the IRM-V038/TR1 Series devices during heating. (3) After soldering, do not warp the circuit board. Everlight Electronics Co., Ltd. Device No DMO-138-376 http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 9 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES Soldering Iron Each terminal is to go to the tip of soldering iron temperature less than 280 for 3 seconds within once in less than the soldering iron capacity 25W. Leave two seconds and more intervals, and do soldering of each terminal. Be careful because the damage of the product is often started at the time of the hand solder. Repairing Repair should not be done after the LEDs have been soldered. When repairing is unavoidable, a double-head soldering iron should be used (as below figure). It should be confirmed beforehand whether the characteristics of the LEDs will or will not be damaged by repairing. ESD Precaution Proper storage and handing procedures should be followed to prevent ESD damage to the devices especially when they are removed from the Anti-static bag. Electro-Static Sensitive Devices warning labels are on the packing. Everlight Electronics Co., Ltd. Device No DMO-138-376 http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 10 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES Carrier Tape Dimensions: Loaded quantity 1500 PCS per reel Progressive Direction Cover Trap Packing process Bar Code Label Everlight Electronics Co., Ltd. Device No DMO-138-376 http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 11 of 12 Prepared by Cindy Lin EVERLIGHT ELECTRONICS CO.,LTD. IRM-H1xx/TR2 SERIES Packing Quantity Specification 1. 1500 PCS/1 Reel 2. 5Reel /1Carton Label Form Specification CPN: Customer's Production Number P/N : Production Number QTY: Packing Quantity CAT: None RoHS HUE: None REF: Reference LOT No: Lot Number MADE IN TAIWAN: Production Place Notes 1. Above specification may be changed without notice. EVERLIGHT will reserve authority on material change for above specification. 2. When using this product, please observe the absolute maximum ratings and the instructions for using outlined in these specification sheets. EVERLIGHT assumes no responsibility for any damage resulting from use of the product which does not comply with the absolute maximum ratings and the instructions included in these specification sheets. 3. These specification sheets include materials protected under copyright of EVERLIGHT corporation. Please don't reproduce or cause anyone to reproduce them without EVERLIGHT's consent. EVERLIGHT ELECTRONICS CO., LTD. Office: No 25, Lane 76, Sec 3, Chung Yang Rd, Tucheng, Taipei 236, Taiwan, R.O.C Everlight Electronics Co., Ltd. Device No DMO-138-376 Tel: 886-2-2267-2000, 2267-9936 Fax: 886-2267-6244, 2267-6189, 2267-6306 http:\\www.everlight.com http:\\www.everlight.com Prepared date 7-11-2007 Rev 2 Page: 12 of 12 Prepared by Cindy Lin